Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med Phys ; 50(9): 5806-5816, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37531199

RESUMEN

BACKGROUND: Novel synchrotron radiotherapy techniques are currently limited to using prefabricated beam-limiting blocks for field definition. For large experiments, a single square tungsten block is often used for every treatment since conformal blocks are both patient and field specific, and require long lead times for fabrication. Future synchrotron radiotherapy treatments would benefit from a dynamic collimator system. PURPOSE: We developed and tested a novel collimator design for use on the Imaging and Medical Beamline (IMBL) at the ANSTO Australian Synchrotron. METHODS: The maximum usable beam size on IMBL is 50-mm wide by 3-mm tall. Given the beam shape, targets must be vertically scanned through the synchrotron beam to cover the target volume. To shape the beam, a novel collimator design was developed, consisting of two semi-circular leaves made from 4-mm thick tungsten sheets, with each leaf capable of both vertical and horizontal movement. A software model was created to optimize motor trajectories and generate deliverable treatment fields. A series of geometric field shapes and clinical target volumes were delivered using the collimator and imaged with a digital imaging detector. Four similarity metrics (volumetric similarity, DICE, and the average and maximum Hausdorff distances) were used to measure differences between the input and planned fields, and the planned and delivered fields. RESULTS: Differences between input and planned fields increased with delivery speed, and were worse for rectangular and square fields compared to circular fields. However, the differences between planned and delivered fields were small, where the maximum average deviation between the fields was 0.25 mm (one pixel). Field repeatability was consistent with no difference (σ = 0 for all metrics) observed in consecutively delivered fields. CONCLUSIONS: We have successfully built and demonstrated a novel collimator for synchrotron radiotherapy applications on IMBL. Several design improvements have been highlighted and will be addressed in future revisions the collimator. However, in its current state, the collimator enables dynamically delivered conformal treatment fields to be utilized on IMBL, and is ready to support the forthcoming canine treatments on IMBL.


Asunto(s)
Radioterapia Conformacional , Sincrotrones , Animales , Perros , Tungsteno , Australia , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Radioterapia Conformacional/métodos
2.
Anal Chem ; 94(11): 4584-4593, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35276040

RESUMEN

Synchrotron-based X-ray fluorescence microscopy (XFM) analysis is a powerful technique that can be used to visualize elemental distributions across a broad range of sample types. Compared to conventional mapping techniques such as laser ablation inductively coupled plasma mass spectrometry or benchtop XFM, synchrotron-based XFM provides faster and more sensitive analyses. However, access to synchrotron XFM beamlines is highly competitive, and as a result, these beamlines are often oversubscribed. Therefore, XFM experiments that require many large samples to be scanned can penalize beamline throughput. Our study was largely driven by the need to scan large gels (170 cm2) using XFM without decreasing beamline throughput. We describe a novel approach for acquiring two sets of XFM data using two fluorescence detectors in tandem; essentially performing two separate experiments simultaneously. We measured the effects of tandem scanning on beam quality by analyzing a range of contrasting samples downstream while simultaneously scanning different gel materials upstream. The upstream gels were thin (<200 µm) diffusive gradients in thin-film (DGT) binding gels. DGTs are passive samplers that are deployed in water, soil, and sediment to measure the concentration and distribution of potentially bioavailable nutrients and contaminants. When deployed on soil, DGTs are typically small (2.5 cm2), so we developed large DGTs (170 cm2), which can be used to provide extensive maps to visualize the diffusion of fertilizers in soil. Of the DGT gel materials tested (bis-acrylamide, polyacrylamide, and polyurethane), polyurethane gels were most suitable for XFM analysis, having favorable handling, drying, and analytical properties. This gel type enabled quantitative (>99%) transmittance with minimal (<3%) flux variation during raster scanning, whereas the other gels had a substantial effect on the beam focus. For the first time, we have (1) used XFM for mapping analytes in large DGTs and (2) developed a tandem probe analysis mode for synchrotron-based XFM, effectively doubling throughput. The novel tandem probe analysis mode described here is of broad applicability across many XFM beamlines as it could be used for future experiments where any uniform, highly transmissive sample could be analyzed upstream in the "background" of downstream samples.


Asunto(s)
Poliuretanos , Sincrotrones , Difusión , Geles , Suelo/química
3.
J Synchrotron Radiat ; 29(Pt 2): 480-487, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35254312

RESUMEN

Over the last decade ptychography has progressed rapidly from a specialist ultramicroscopy technique into a mature method accessible to non-expert users. However, to improve scientific value ptychography data must reconstruct reliably, with high image quality and at no cost to other correlative methods. Presented here is the implementation of high-speed ptychography used at the Australian Synchrotron on the XFM beamline, which includes a free-run data collection mode where dead time is eliminated and the scan time is optimized. It is shown that free-run data collection is viable for fast and high-quality ptychography by demonstrating extremely high data rate acquisition covering areas up to 352 000 µm2 at up to 140 µm2 s-1, with 13× spatial resolution enhancement compared with the beam size. With these improvements, ptychography at velocities up to 250 µm s-1 is approaching speeds compatible with fast-scanning X-ray fluorescence microscopy. The combination of these methods provides morphological context for elemental and chemical information, enabling unique scientific outcomes.


Asunto(s)
Microscopía , Sincrotrones , Australia , Microscopía/métodos
4.
J Synchrotron Radiat ; 27(Pt 5): 1447-1458, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876622

RESUMEN

The X-ray fluorescence microscopy (XFM) beamline is an in-vacuum undulator-based X-ray fluorescence (XRF) microprobe beamline at the 3 GeV Australian Synchrotron. The beamline delivers hard X-rays in the 4-27 keV energy range, permitting K emission to Cd and L and M emission for all other heavier elements. With a practical low-energy detection cut-off of approximately 1.5 keV, low-Z detection is constrained to Si, with Al detectable under favourable circumstances. The beamline has two scanning stations: a Kirkpatrick-Baez mirror microprobe, which produces a focal spot of 2 µm × 2 µm FWHM, and a large-area scanning `milliprobe', which has the beam size defined by slits. Energy-dispersive detector systems include the Maia 384, Vortex-EM and Vortex-ME3 for XRF measurement, and the EIGER2 X 1 Mpixel array detector for scanning X-ray diffraction microscopy measurements. The beamline uses event-mode data acquisition that eliminates detector system time overheads, and motion control overheads are significantly reduced through the application of an efficient raster scanning algorithm. The minimal overheads, in conjunction with short dwell times per pixel, have allowed XFM to establish techniques such as full spectroscopic XANES fluorescence imaging, XRF tomography, fly scanning ptychography and high-definition XRF imaging over large areas. XFM provides diverse analysis capabilities in the fields of medicine, biology, geology, materials science and cultural heritage. This paper discusses the beamline status, scientific showcases and future upgrades.

5.
Opt Express ; 25(19): 23424-23436, 2017 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-29041643

RESUMEN

Scanning X-ray fluorescence tomography was once considered impractical due to prohibitive measurement time requirements but is now common for investigating metal distributions within small systems. A recent look-ahead to the possibilities of 4th-generation synchrotron light sources [J. Synchrotron. Radiat. 21, 1031 (2014)] raised the possibility of a spiral-scanning measurement scheme where motion overheads are almost completely eliminated. Here we demonstrate the spiral scanning measurement and use Fourier ring correlation analysis to interrogate sources of resolution degradation. We develop an extension to the Fourier ring correlation formalism that enables direct determination of resolution from the measured sinogram data, greatly enhancing its power as a diagnostic tool for computed tomography.

6.
J Synchrotron Radiat ; 23(Pt 5): 1151-7, 2016 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-27577770

RESUMEN

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...