Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Oxf Med Case Reports ; 2021(8): omab059, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34408883

RESUMEN

ATTR-CA is an under-reported cause of congestive heart failure (CHF) and cardiac arrhythmias. Heightened clinical suspicion along with a multimodal investigative approach is often required in diagnosing this potentially fatal condition. Tafamidis and inotersen have shown promising results in terms of progression-free survival by ameliorating CHF symptoms and peripheral neuropathies in clinical trials. In this case series of five patients, we present three wild-type cardiac amyloidosis (ATTRwt-CA), one familial cardiac amyloidosis (ATTRm-CA) and one primary cardiac (AL-CA). The diagnostic modality was different for each patient. ATTRwt-CA, ATTRm-CA and AL-CA patients received tafamidis, inotersen and chemotherapy with bone marrow stem-cell transplantation, respectively.

2.
JACC Cardiovasc Interv ; 5(8): 837-44, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22917455

RESUMEN

OBJECTIVES: The goal of this study was to assess the frequency and predictors of vascular closure device (VCD) deployment failure, and its association with vascular complications of 3 commonly used VCDs. BACKGROUND: VCDs are commonly used following percutaneous coronary intervention on the basis of studies demonstrating reduced time to ambulation, increased patient comfort, and possible reduction in vascular complications as compared with manual compression. However, limited data are available on the frequency and predictors of VCD failure, and the association of deployment failure with vascular complications. METHODS: From a de-identified dataset provided by Massachusetts Department of Health, 23,813 consecutive interventional coronary procedures that used either a collagen plug-based (n = 18,533), a nitinol clip-based (n = 2,284), or a suture-based (n = 2,996) VCD between June 2005 and December 2007 were identified. The authors defined VCD failure as unsuccessful deployment or failure to achieve immediate access site hemostasis. RESULTS: Among 23,813 procedures, the VCD failed in 781 (3.3%) procedures (2.1% of collagen plug-based, 6.1% of suture-based, 9.5% of nitinol clip-based VCDs). Patients with VCD failure had an excess risk of "any" (7.7% vs. 2.8%; p < 0.001), major (3.3% vs. 0.8%; p < 0.001), or minor (5.8% vs. 2.1%; p < 0.001) vascular complications compared with successful VCD deployment. In a propensity score-adjusted analysis, when compared with collagen plug-based VCD (reference odds ratio [OR] = 1.0), nitinol clip-based VCD had 2-fold increased risk (OR: 2.0, 95% confidence interval [CI]: 1.8 to 2.3, p < 0.001) and suture-based VCD had 1.25-fold increased risk (OR: 1.25, 95% CI: 1.2 to 1.3, p < 0.001) for VCD failure. VCD failure was a significant predictor of subsequent vascular complications for both collagen plug-based VCD and nitinol clip-based VCD, but not for suture-based VCD. CONCLUSIONS: VCD failure rates vary depending upon the type of VCD used and are associated with significantly higher vascular complications as compared with deployment successes.


Asunto(s)
Falla de Equipo/estadística & datos numéricos , Intervención Coronaria Percutánea , Procedimientos Quirúrgicos Vasculares/instrumentación , Técnicas de Cierre de Heridas/instrumentación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...