Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur Heart J Case Rep ; 8(1): ytae004, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38239312

RESUMEN

Background: Twiddler syndrome (TS) is a complication of cardiac implantable electronic device (CIED) implantation, caused by the deliberate or unconscious manipulation of the device by the patient himself, which results in dislocation of the leads by retraction towards the subcutaneous pocket. Case summary: This report describes two clinical cases that occurred in our centre, for which two different solutions were successfully implemented. In the first case, a complete removal of the stimulation system was performed, and a leadless pacemaker (PM; Medtronic Micra VR) was implanted. In the second case, the patient underwent a revision procedure. The PM was disconnected, and the electrodes were debrided, a submuscular pocket for the PM was created, and at the end of the procedure, the PM was anchored to the pectoralis major. Discussion: Twiddler syndrome is a not so rare and serious complication of CIED implantation, leading to device malfunctioning and higher risk of infection of the pocket due to multiple re-interventions. In these two cases, different surgical solutions were performed, both resulting to be effective to solve the effects of TS.

2.
J Clin Med ; 12(14)2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37510858

RESUMEN

The study was designed to assess patient adherence to wearable cardioverter defibrillator as an indicator of device effectiveness. The patient training is not widely properly standardized. We enrolled 25 patients with a wearable cardioverter defibrillator to prevent sudden cardiac death between June 2020 and August 2022. Among them, 84% were male with a median age of 63.6 years. The indication was an ischemic (44%) and a non-ischemic (56%) disease. The patients were followed-up until the decision to upgrade to an implantable device was taken. We trained the patients according to our suggested protocol. The median wear time was 90 days, and the median daily wear time was 23.5 h, similar throughout sex, age, and indication groups. In total, 24% of the participants underwent cardioverter defibrillator implantation. Between the device-implanted and non-implanted groups, left ventricular ejection fraction and left ventricular indexed end-diastolic volume were significantly different (EF 35.8 ± 12 vs. 46.4 ± 8.5%, p = 0.028, iEDV 108 ± 52 vs. 70.7 ± 21.1 mL/m2, p = 0.024). We did not find any differences in cardiac magnetic resonance data, even though all patients who underwent device implantation had late gadolinium enhancement spots. Our results support standardized patient training to obtain great patient adherence to the instructions to the wearable device and therefore its effectiveness.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA