Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 51(1): 200-4, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14705062

RESUMEN

Parallel imaging applied to first-pass, contrast-enhanced cardiac MR can yield greater spatial coverage for a fixed temporal resolution. The method combines rate R=2 acceleration using TSENSE with shot-to-shot interleaving of two slices. The square root R SNR loss is largely compensated for by a longer effective repetition time (TR) and increased flip angle associated with slice interleaving. In this manner, increased spatial coverage is achieved while comparable or better image quality is maintained. Single-heartbeat temporal resolution was accomplished with spatial coverage of eight slices at heart rates up to 71 bpm, six slices up to 95 bpm, and four slices up to 143 bpm. Experiments in normal subjects (N=6) were performed to assess signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values.


Asunto(s)
Imagen Eco-Planar/métodos , Corazón/fisiología , Artefactos , Medios de Contraste/administración & dosificación , Circulación Coronaria , Gadolinio DTPA/administración & dosificación , Humanos , Procesamiento de Imagen Asistido por Computador , Inyecciones
2.
J Magn Reson Imaging ; 14(6): 698-704, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11747026

RESUMEN

Inflammation contributes to atherosclerosis, but assessment in humans is largely restricted to measurement of markers in blood. We determined whether MRI properties of large arteries were associated with markers of inflammation in serum. Double inversion recovery, fast spin-echo images of the common carotid arteries and infrarenal aorta were obtained at 1.5 T both before and after gadolinium-DTPA (0.1 mmol/kg) in 52 subjects > or =40 years of age, 17 of whom had no risk factors for atherosclerosis and thus served as controls. Twenty-two study participants had increases in wall thickness (14), T2-weighted signal intensity (11), and/or contrast enhancement values (7) that were >2 standard deviations (SDs) from control group mean values. Ten subjects in this group had evidence of focal plaques in the carotids (5) and/or aorta (6). Compared with the remaining 30 subjects, these 22 had significantly higher levels of interleukin-6 (3.53 +/- 2.46 vs. 1.97 +/- 1.37 pg/mL, P = 0.004), C-reactive protein (0.56 +/- 0.98 vs. 0.30 +/- 0.52 mg/dL, P = 0.019), vascular cell adhesion molecule-1 (572 +/- 153 vs. 471 +/- 130 ng/mL, P = 0.012), and intercellular adhesion molecule-1 (244 +/- 80 vs. 202 +/- 45 ng/mL, P = 0.015), and nonsignificant differences in levels of E-selectin (46.1 +/- 18.9 vs. 42.3 +/- 11.3 ng/mL, P = 0.369). Thus, MRI characteristics of the aorta and carotid arteries were associated with elevated serum markers of inflammation, frequently in the absence of definite atheroma. MRI of large arteries may provide a new approach to investigate the contribution of inflammation to atherogenesis.


Asunto(s)
Aorta Abdominal/patología , Arterias Carótidas/patología , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/patología , Imagen por Resonancia Magnética , Adulto , Anciano , Biomarcadores/sangre , Proteína C-Reactiva/metabolismo , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Humanos , Inflamación/sangre , Inflamación/patología , Molécula 1 de Adhesión Intercelular/sangre , Interleucina-6/sangre , Masculino , Persona de Mediana Edad , Molécula 1 de Adhesión Celular Vascular/sangre
3.
Am J Cardiol ; 84(12): 1434-9, 1999 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-10606118

RESUMEN

Left ventricular (LV) volumes are important prognostic indexes in patients with heart disease. Although several methods can evaluate LV volumes, most have important intrinsic limitations. Real-time 3-dimensional echocardiography (RT3D echo) is a novel technique capable of instantaneous acquisition of volumetric images. The purpose of this study was to validate LV volume calculations with RT3D echo and to determine their usefulness in cardiac patients. To this end, 4 normal subjects and 21 cardiac patients underwent magnetic resonance imaging (MRI) and RT3D echo on the same day. A strong correlation was found between LV volumes calculated with MRI and with RT3D echo (r = 0.91; y = 20.1 + 0.71x; SEE 28 ml). LV volumes obtained with MRI were greater than those obtained with RT3D echo (126 +/- 83 vs 110 +/- 65 ml; p = 0.002), probably due to the fact that heart rate during MRI acquisition was lower than that during RT3D echo examination (62 +/- 11 vs 79 +/- 16 beats/min; p = 0.0001). Analysis of intra- and interobserver variability showed strong indexes of agreement in the measurement of LV volumes with RT3D echo. Thus, LV volume measurements with RT3D echo are accurate and reproducible. This technique expands the use of ultrasound for the noninvasive evaluation of cardiac patients and provides a new tool for the investigational study of cardiovascular disease.


Asunto(s)
Volumen Cardíaco/fisiología , Sistemas de Computación , Ecocardiografía , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Adulto , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/fisiopatología , Femenino , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/fisiopatología , Humanos , Hipertrofia Ventricular Izquierda/fisiopatología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Estudios Prospectivos , Valores de Referencia , Función Ventricular Izquierda/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA