Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Med Educ ; 6: 93-100, 2015 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-26223033

RESUMEN

OBJECTIVE: This study aimed to explore the value of individualized feedback on performance, flow and self-efficacy during simulated laparoscopy. Furthermore, we wished to explore attitudes towards feedback and simulator training among medical students. METHODS: Sixteen medical students were included in the study and randomized to laparoscopic simulator training with or without feedback. A teacher provided individualized feedback continuously throughout the procedures to the target group. Validated questionnaires and scales were used to evaluate self-efficacy and flow. The Mann-Whitney U test was used to evaluate differences between groups regarding laparoscopic performance (instrument path length), self-efficacy and flow. Qualitative data was collected by group interviews and interpreted using inductive thematic analyses. RESULTS: Sixteen students completed the simulator training and questionnaires. Instrument path length was shorter in the feedback group (median 3.9 m; IQR: 3.3-4.9) as compared to the control group (median 5.9 m; IQR: 5.0-8.1), p<0.05. Self-efficacy improved in both groups. Eleven students participated in the focus interviews. Participants in the control group expressed that they had fun, whereas participants in the feedback group were more concentrated on the task and also more anxious. Both groups had high ambitions to succeed and also expressed the importance of getting feedback. The authenticity of the training scenario was important for the learning process. CONCLUSIONS: This study highlights the importance of individualized feedback during simulated laparoscopy training. The next step is to further optimize feedback and to transfer standardized and individualized feedback from the simulated setting to the operating room.


Asunto(s)
Actitud , Retroalimentación , Laparoscopía/educación , Entrenamiento Simulado , Estudiantes de Medicina/psicología , Adulto , Femenino , Humanos , Masculino , Adulto Joven
2.
Acta Obstet Gynecol Scand ; 92(10): 1194-201, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24461067

RESUMEN

OBJECTIVE: To investigate how simulator training and non-technical factors affect laparoscopic performance among residents in obstetrics and gynecology. DESIGN: In this prospective study, trainees were randomized into three groups. The first group was allocated to proficiency-based training in the LapSimGyn(®) virtual reality simulator. The second group received additional structured mentorship during subsequent laparoscopies. The third group served as control group. At baseline an operation was performed and visuospatial ability, flow and self-efficacy were assessed. All groups subsequently performed three tubal occlusions. Self-efficacy and flow were assessed before and/or after each operation. SETTING: Simulator training was conducted at the Center for Advanced Medical Simulation and Training, Karolinska University Hospital. Sterilizations were performed at each trainee's home clinic. POPULATION: Twenty-eight trainees/residents from 21 hospitals in Sweden were included. METHODS/MAIN OUTCOME MEASURES: Visuospatial ability was tested by the Mental Rotation Test-A. Flow and self-efficacy were assessed by validated scales and questionnaires. Laparoscopic performance was measured as the duration of surgery. Visuospatial ability, self-efficacy and flow were correlated to the laparoscopic performance using Spearman's correlations. Differences between groups were analyzed by the Mann-Whitney U-test. RESULTS: No differences across groups were detected at baseline. Self-efficacy scores before and flow scores after the third operation were significantly higher in the trained groups. Duration of surgery was significantly shorter in the trained groups. Flow and self-efficacy correlate positively with laparoscopic performance. CONCLUSIONS: Simulator training and non-technical factors appear to improve the laparoscopic performance among trainees/residents in obstetrics and gynecology.


Asunto(s)
Competencia Clínica , Simulación por Computador , Ginecología/educación , Laparoscopía/educación , Obstetricia/educación , Interfaz Usuario-Computador , Adulto , Femenino , Humanos , Masculino , Mentores , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Desempeño Psicomotor , Autoeficacia , Suecia
3.
Eur J Obstet Gynecol Reprod Biol ; 157(1): 73-7, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21450391

RESUMEN

OBJECTIVE: To analyze the relationship between visuospatial ability and simulated laparoscopy performed by consultants in obstetrics and gynecology (OBGYN). STUDY DESIGN: This was a prospective cohort study carried out at two community hospitals in Sweden. Thirteen consultants in obstetrics and gynecology were included. They had previously independently performed 10-100 advanced laparoscopies. Participants were tested for visuospatial ability by the Mental Rotations Test version A (MRT-A). After a familiarization session and standardized instruction, all participants subsequently conducted three consecutive virtual tubal occlusions followed by three virtual salpingectomies. Performance in the simulator was measured by Total Time, Score and Ovarian Diathermy Damage. Linear regression was used to analyze the relationship between visuospatial ability and simulated laparoscopic performance. The learning curves in the simulator were assessed in order to interpret the relationship with the visuospatial ability. RESULTS: Visuospatial ability correlated with Total Time (r=-0.62; p=0.03) and Score (r=0.57; p=0.05) in the medium level of the virtual tubal occlusion. In the technically more advanced virtual salpingectomy the visuospatial ability correlated with Total Time (r=-0.64; p=0.02), Ovarian Diathermy Damage (r=-0.65; p=0.02) and with overall Score (r=0.64; p=0.02). CONCLUSIONS: Visuospatial ability appears to be related to the performance of gynecological laparoscopic procedures in a simulator. Testing visuospatial ability might be helpful when designing individual training programs.


Asunto(s)
Aptitud , Simulación por Computador , Procedimientos Quirúrgicos Ginecológicos/educación , Procedimientos Quirúrgicos Ginecológicos/métodos , Examen Ginecologíco/métodos , Laparoscopía/educación , Análisis y Desempeño de Tareas , Adulto , Estudios de Cohortes , Consultores , Femenino , Procedimientos Quirúrgicos Ginecológicos/efectos adversos , Examen Ginecologíco/efectos adversos , Humanos , Laparoscopía/efectos adversos , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Competencia Profesional , Estudios Prospectivos , Salpingectomía/efectos adversos , Salpingectomía/educación , Salpingectomía/métodos , Esterilización Tubaria/efectos adversos , Esterilización Tubaria/educación , Esterilización Tubaria/métodos , Suecia , Interfaz Usuario-Computador
4.
Acta Obstet Gynecol Scand ; 85(2): 195-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16532914

RESUMEN

BACKGROUND: The objective was to study fetal growth parameters in in vitro fertilization (IVF) pregnancies and to investigate the relationship between fetal growth and maternal blood pressure. METHODS: We examined 64 women, pregnant after in vitro fertilization, with repeated ultrasound examinations measuring biparietal diameter, femur length, abdominal diameter and fetal weight at 24, 30, and 36 weeks of gestation. We calculated deviations in percent from expected values in regards to biparietal diameter, femur length, abdominal diameter, and fetal weight. Blood pressure was measured every second week. RESULTS: Biparietal diameter in the study group was significantly smaller at 24 (-3.3%, 95%CI -4.4 to -2.2) and 30 (-1.4%; 95%CI -2.5% to -0.3) weeks. Femur length differed significantly on all three occasions, at 24 (-6.3%; 95%CI -7.7 to -5.1), 30 (-6.6%; 95%CI -8.0 to -5.3), and 36 (-3.9%; 95%CI; -5.0 to -2.8) weeks. Abdominal diameter demonstrated a significant deviation at 24 weeks (-1.6%; 95%CI -2.8 to -0.4). Fetal weight did not reach significant deviations at any gestational age. There was no correlation between deviation of the individual growth parameters or estimated fetal weight and elevated blood pressure. CONCLUSION: The growth pattern of in vitro fertilization pregnancies does not seem to differ from spontaneously conceived pregnancies to any appreciable extent. In the present material, no relationship between fetal growth and maternal blood pressure could be observed. We could not show that an impaired fetal growth predates the development of hypertension.


Asunto(s)
Fertilización In Vitro , Retardo del Crecimiento Fetal/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Femenino , Humanos , Hipertensión/etiología , Embarazo , Resultado del Embarazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA