Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JMIR Mhealth Uhealth ; 7(6): e13327, 2019 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-31199336

RESUMEN

BACKGROUND: Cardiorespiratory fitness (CRF), an important index of physical fitness, is the ability to inhale and provide oxygen to the exercising muscle. However, despite its importance, the current gold standard for measuring CRF is impractical, requiring maximal exercise from the participants. OBJECTIVE: This study aimed to develop a convenient and practical estimation model for CRF using data collected from daily life with a wristwatch-type device. METHODS: A total of 191 subjects, aged 20 to 65 years, participated in this study. Maximal oxygen uptake (VO2 max), a standard measure of CRF, was measured with a maximal exercise test. Heart rate (HR) and physical activity data were collected using a commercial wristwatch-type fitness tracker (Fitbit; Fitbit Charge; Fitbit) for 3 consecutive days. Maximal activity energy expenditure (aEEmax) and slope between HR and physical activity were calculated using a linear regression. A VO2 max estimation model was built using multiple linear regression with data on age, sex, height, percent body fat, aEEmax, and the slope. The result was validated with 2 different cross-validation methods. RESULTS: aEEmax showed a moderate correlation with VO2 max (r=0.50). The correlation coefficient for the multiple linear regression model was 0.81, and the SE of estimate (SEE) was 3.518 mL/kg/min. The regression model was cross-validated through the predicted residual error sum of square (PRESS). The PRESS correlation coefficient was 0.79, and the PRESS SEE was 3.667 mL/kg/min. The model was further validated by dividing it into different subgroups and calculating the constant error (CE) where a low CE showed that the model does not significantly overestimate or underestimate VO2 max. CONCLUSIONS: This study proposes a CRF estimation method using data collected by a wristwatch-type fitness tracker without any specific protocol for a wide range of the population.


Asunto(s)
Monitores de Ejercicio/normas , Consumo de Oxígeno/fisiología , Oxígeno/análisis , Adulto , Anciano , Índice de Masa Corporal , Estudios Transversales , Prueba de Esfuerzo/métodos , Prueba de Esfuerzo/estadística & datos numéricos , Femenino , Monitores de Ejercicio/estadística & datos numéricos , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Terapia por Inhalación de Oxígeno/normas , Terapia por Inhalación de Oxígeno/estadística & datos numéricos , Reproducibilidad de los Resultados , República de Corea
2.
Sensors (Basel) ; 19(9)2019 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-31035399

RESUMEN

Suffering from continuous stress can lead to serious psychological and even physical disorders. Objective stress assessment methods using noninvasive physiological responses such as heart rate variability (HRV) and electroencephalograms (EEG) have therefore been proposed for effective stress management. In this study, a novel wearable device that can measure electrocardiograms (ECG) and EEG simultaneously was designed to enable continuous stress monitoring in daily life. The developed system is easily worn by hanging from both ears, is lightweight (i.e., 42.5 g), and exhibits an excellent noise performance of 0.12 µVrms. Significant time and frequency features of HRV and EEG were found in two different stressors, namely the Stroop color word and mental arithmetic tests, using 14 young subjects. Stressor situations were classified using various HRV and EEG feature selections and a support vector machine technique. The five-fold cross-validation results obtained when using both EEG and HRV features showed the best performance with an accuracy of 87.5%, which demonstrated the requirement for simultaneous HRV and EEG measurements.


Asunto(s)
Electrocardiografía/métodos , Electroencefalografía/métodos , Estrés Psicológico , Dispositivos Electrónicos Vestibles , Adulto , Área Bajo la Curva , Electrocardiografía/instrumentación , Electroencefalografía/instrumentación , Frecuencia Cardíaca , Humanos , Masculino , Curva ROC , Máquina de Vectores de Soporte
3.
Sci Rep ; 9(1): 5009, 2019 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-30899066

RESUMEN

We propose a wirelessly controlled implantable system for on-demand and pulsatile insulin delivery with a more convenient and safer strategy than currently available strategies. The system is a combined entity of a magnetically driven pump (i.e., an MDP), external control device (i.e., an ECD) and mobile app. The MDP for implantation consists of a plunger, barrel and drug reservoir, where an accurate amount of insulin can be infused in a pulsatile manner only at the time when a magnetic force is applied to actuate the plunger in the barrel. The ECD at the outside body can modulate the MDP actuation with an electromagnet and its control circuit, and this modulation can be wirelessly controlled by the mobile app. As a safety feature, the mobile app is programmed to pre-set the restrictions for the insulin dose and administration schedule to avoid overdose. The system is shown to infuse insulin in a highly reproducible manner, but it does not allow for insulin infusion when the pre-set restrictions are violated. When tested with diabetic rats, the profiles of insulin plasma concentration and blood glucose level are similar to those of animals treated with a subcutaneous injection of the same dose of insulin.


Asunto(s)
Diabetes Mellitus Experimental/tratamiento farmacológico , Bombas de Infusión Implantables , Sistemas de Infusión de Insulina , Insulina/farmacología , Animales , Glucemia/efectos de los fármacos , Diabetes Mellitus Experimental/patología , Humanos , Inyecciones Subcutáneas , Insulina/metabolismo , Imanes , Ratas
4.
J Korean Med Sci ; 33(21): e154, 2018 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-29780294

RESUMEN

BACKGROUND: One of the key issues in electroencephalogram (EEG) monitoring is accurate signal acquisition with less cumbersome electrodes. In this study, the L2 phase electro-deposited nanoporous platinum (L2-ePt) electrode is introduced, which is a new type of electrode that utilizes a stable nanoporous platinum surface to reduce the skin-electrode impedance. METHODS: L2-ePt electrodes were fabricated using electro-deposition technique. Then, the effect of the nanoporous surface on the surface roughness and the electrode impedance were observed from the L2-ePt electrodes and the flat platinum (FlatPt) electrode. The skin-electrode impedances of the L2-ePt electrodes, a gold cup electrode, and the FlatPt electrode were evaluated when placed on the hairy occipital area of the head in ten subjects. For the validation of using the L2-ePt electrode, a correlational analysis of the alpha rhythms was performed in the same subjects for simultaneous EEG recordings using the L2-ePt and clinically-used EEG electrodes. RESULTS: The results indicated that the L2-ePt electrode with a roughness factor of 200 had the lowest mean impedance performance. Moreover, the proposed L2-ePt electrode showed a significantly lower mean skin-electrode impedance than the FlatPt electrode. Finally, the EEG signal quality recorded by the L2-ePt electrode (r = 0.94) was comparable to that of the clinically-used gold cup electrode. CONCLUSION: Based on these results, the proposed L2-ePt electrode is suitable for use in various high-quality EEG applications.


Asunto(s)
Electroencefalografía/métodos , Nanoporos , Platino (Metal)/química , Electrodos Implantados , Electroencefalografía/instrumentación , Modelos Biológicos , Propiedades de Superficie
5.
J Korean Med Sci ; 32(12): 1947-1952, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29115075

RESUMEN

Despite the importance of cardiorespiratory fitness, no practical method exists to estimate maximal oxygen consumption (VO2max) without a specific exercise protocol. We developed an estimation model of VO2max, using maximal activity energy expenditure (aEEmax) as a new feature to represent the level of physical activity. Electrocardiogram (ECG) and acceleration data were recorded for 4 days in 24 healthy young men, and reference VO2max levels were measured using the maximal exercise test. aEE was calculated using the measured acceleration data and body weight, while heart rate (HR) was extracted from the ECG signal. aEEmax was obtained using linear regression, with aEE and HR as input parameters. The VO2max was estimated from the aEEmax using multiple linear regression modeling in the training group (n = 16) and was verified in the test group (n = 8). High correlations between the estimated VO2max and the measured VO2max were identified in both groups, with a 15-hour recording being sufficient to produce a highly accurate VO2max estimate. Additional recording time did not significantly improve the accuracy of the estimation. Our VO2max estimation method provides a robust alternative to traditional approaches while only requiring minimal data acquisition time in daily life.


Asunto(s)
Capacidad Cardiovascular/fisiología , Adulto , Peso Corporal , Electrocardiografía , Metabolismo Energético , Prueba de Esfuerzo , Frecuencia Cardíaca , Humanos , Modelos Lineales , Masculino , Consumo de Oxígeno , Adulto Joven
6.
Hear Res ; 348: 120-128, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28286100

RESUMEN

The present study aimed to investigate whether gap-prepulse inhibition (GPI) deficit in patients with tinnitus occurred in the N1-P2 complex of the cortical auditory evoked potential. Auditory late responses to the intense sound of the GPI paradigm were obtained from 16 patients with tinnitus and 18 age- and hearing loss-matched controls without tinnitus. The inhibition degrees of the N1-P2 complex were assessed at 100-, 50-, and 20-ms gap durations with tinnitus-pitch-matched and non-matched frequency background noises. At the 20-ms gap condition with the tinnitus-pitch-matched frequency background noise, only the tinnitus group showed an inhibition deficit of the N1-P2 complex. The inhibition deficits were absent in both groups with longer gap durations. These findings suggested that the effect of tinnitus emerged depending on the cue onset timing and duration of the gap-prepulse. Since inhibition deficits were observed in both groups at the same 20-ms gap condition, but with the tinnitus-pitch-non-matched frequency background noise, the present study did not offer proof of concept for tinnitus filling in the gap. Additional studies on the intrinsic effects of different background frequencies on the gap processing are required in the future.


Asunto(s)
Estimulación Acústica , Corteza Auditiva/fisiología , Potenciales Evocados Auditivos/fisiología , Inhibición Prepulso , Acúfeno/fisiopatología , Acústica , Adulto , Anciano , Percepción Auditiva , Umbral Auditivo/fisiología , Parpadeo , Estudios de Casos y Controles , Electrodos , Electromiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ruido , Tiempo de Reacción , Reflejo de Sobresalto/fisiología
7.
Psychophysiology ; 52(11): 1511-9, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26272085

RESUMEN

The gap-startle paradigm has been used as a behavioral method for tinnitus screening in animal studies. This study aimed to investigate gap prepulse inhibition (GPI) of the auditory late response (ALR) as the objective response of the gap-intense sound paradigm in humans. ALRs were recorded in response to gap-intense and no-gap-intense sound stimuli in 27 healthy subjects. The amplitudes of the baseline-to-peak (N1, P2, and N2) and the peak-to-peak (N1P2 and P2N2) were compared between two averaged ALRs. The variations in the inhibition ratios of N1P2 and P2N2 during the experiment were analyzed by increasing stimuli repetitions. The effect of stimulus parameter adjustments on GPI ratios was evaluated. No-gap-intense sound stimuli elicited greater peak amplitudes than gap-intense sound stimuli, and significant differences were found across all peaks. The overall mean inhibition ratios were significantly lower than 1.0, where the value 1.0 indicates that there were no differences between gap-intense and no-gap-intense sound responses. The initial decline in GPI ratios was shown in N1P2 and P2N2 complexes, and this reduction was nearly complete after 100 stimulus repetitions. Significant effects of gap length and interstimulus interval on GPI ratios were observed. We found significant inhibition of ALR peak amplitudes in performing the gap-intense sound paradigm in healthy subjects. The N1P2 complex represented GPI well in terms of suppression degree and test-retest reliability. Our findings offer practical information for the comparative study of healthy subjects and tinnitus patients using the gap-intense sound paradigm with the ALR.


Asunto(s)
Corteza Auditiva/fisiología , Potenciales Evocados Auditivos/fisiología , Inhibición Prepulso/fisiología , Reflejo de Sobresalto/fisiología , Estimulación Acústica , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Adulto Joven
8.
Artículo en Inglés | MEDLINE | ID: mdl-25570560

RESUMEN

This paper presents the development of a single platform that records auditory evoked potential synchronized to specific acoustic stimuli of the gap prepulse inhibition method for objective tinnitus diagnosis research. The developed system enables to program various parameters of the generated acoustic stimuli. Moreover, only by simple filter modification, the developed system provides high flexibility to record not only short latency auditory brainstem response but also late latency auditory cortical response. The adaptive weighted averaging algorithm to minimize the time required for the experiment is also introduced. The results show that the proposed algorithm can reduce the number of the averaging repetitions to 70% compared with conventional ensemble averaging method.


Asunto(s)
Estimulación Acústica/métodos , Técnicas de Diagnóstico Otológico/instrumentación , Potenciales Evocados Auditivos/fisiología , Procesamiento de Señales Asistido por Computador/instrumentación , Acúfeno/diagnóstico , Algoritmos , Investigación Biomédica , Diseño de Equipo , Humanos , Tiempo de Reacción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...