Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 8(1)2017 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-29271936

RESUMEN

Endocrine Disrupting Compounds (EDCs) are chemical substances shown to interfere with endogenous hormones affecting the endocrine, immune and nervous systems of mammals. EDCs are the causative agents of diseases including reproductive disorders and cancers. This highlights the urgency to develop fast and sensitive methods to detect EDCs, which are detrimental even at very low concentrations. In this work, we propose a label-free surface plasmon resonance (SPR) biosensor method to detect specific EDCs (17 ß-estradiol (E2), ethinyl-estradiol, 4-nonylphenol, tamoxifen) through their binding to estrogen receptor alpha (ERα). We show that the use of rationally designed ERα (as bio-recognition element) in combination with conformation-sensitive peptides (as amplification agent, resulting in increased responses) enables the detection of low parts per billion (ppb) levels of E2. As a proof of concept, this bioassay was used to detect E2 in (spiked) real water samples from fish farms, rivers and the sea at low ppb levels after concentration by solid phase extraction. In addition, the present SPR assay that combines a conformation-sensitive peptide with an array of ERα mutants is very promising for the assessment of the risk of potential estrogenic activity for chemical substances.


Asunto(s)
Disruptores Endocrinos/análisis , Ingeniería de Proteínas , Receptores de Estrógenos/metabolismo , Resonancia por Plasmón de Superficie/métodos , Péptidos/química , Receptores de Estrógenos/genética
2.
Langmuir ; 25(11): 6312-8, 2009 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-19317422

RESUMEN

Arrays of circular spots of glucose oxidase have been obtained on functionalized silicon oxide by piezoelectric inkjet printing and the enzymatic activity toward glucose recognition has been monitored. The addition of glycerol to the molecular ink allows to obtain high spot definition and resolution (tens of micrometers wide; one molecule tall), but in spite of its well-known structural stabilizing properties, in dynamic conditions it may lead to increased protein stresses. The jetting voltage and pulse length have been found to be critical factors for both activity retention and pattern definition. High voltages and pulse lengths results in stress effects along with the loss of activity, which, at least in our experimental conditions, has been found to be recovered in time.


Asunto(s)
Glucosa Oxidasa/química , Tinta , Análisis por Matrices de Proteínas , Glicerol/química , Microscopía Electrónica de Rastreo , Relación Estructura-Actividad , Propiedades de Superficie
3.
Sensors (Basel) ; 9(5): 3469-90, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-22412322

RESUMEN

The aim of this paper is to summarize the efforts carried out so far in the fabrication of Si-based biosensors by a team of researchers in Catania, Italy. This work was born as a collaboration between the Catania section of the Microelectronic and Microsystem Institute (IMM) of the CNR, the Surfaces and Interfaces laboratory (SUPERLAB) of the Consorzio Catania Ricerche and two departments at the University of Catania: the Biomedical Science and the Biological Chemistry and Molecular Biology Departments. The first goal of our study was the definition and optimization of an immobilization protocol capable of bonding the biological sensing element on a Si-based surface via covalent chemical bonds. We chose SiO(2) as the anchoring surface due to its biocompatibility and extensive presence in microelectronic devices. The immobilization protocol was tested and optimized, introducing a new step, oxide activation, using techniques compatible with microelectronic processing. The importance of the added step is described by the experimental results. We also tested different biological molecule concentrations in the immobilization solutions and the effects on the immobilized layer. Finally a MOS-like structure was designed and fabricated to test an electrical transduction mechanism. The results obtained so far and the possible evolution of the research field are described in this review paper.

4.
Langmuir ; 24(5): 1965-72, 2008 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-18205419

RESUMEN

A process to immobilize the enzyme glucose oxidase on SiO2 surfaces for the realization of integrated microbiosensors was developed. The sample characterization was performed by monitoring, step by step, oxide activation, silanization, linker molecule (glutaraldehyde) deposition, and enzyme immobilization by means of XPS, AFM, and contact angle measurements. The control of the environment during the procedure, to prevent silane polymerization, and the use of oxide activation to obtain a uniform enzyme layer are issues of crucial importance. The correct protocol application gives a uniform layer of the linker molecule and the maximum sample surface coverage. This result is fundamental for maximizing the enzyme bonding sites on the sample surface and achieving the maximum surface coverage. Thin SiO2 layers thermally grown on a Si substrate were used. The XPS Si 2p signal of the substrate was monitored during immobilization. Such a signal is not completely shielded by the thin oxide layer and it is fully suppressed after the completion of the whole protocol. A power spectral density analysis on the AFM measurements showed the crucial role of both the oxide activation and the intermediate steps (silanization and linker molecule deposition) to obtain uniform immobilized enzyme coverage. Finally, enzymatic activity measurements confirmed the suitability of the optimized protocol.


Asunto(s)
Enzimas Inmovilizadas , Glucosa Oxidasa/química , Dióxido de Silicio/química , Electrones , Microscopía de Fuerza Atómica , Análisis Espectral , Propiedades de Superficie , Rayos X
5.
Sensors (Basel) ; 8(9): 5637-5648, 2008 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-27873833

RESUMEN

Silicon dioxide surfaces, both bulk and porous, were used to anchor the enzyme glucose oxidase. The immobilization protocol was optimized and the samples characterized using X-ray Photoelectron Spectroscopy, Energy Dispersive X-rays coupled to scanning electron microscopy and enzymatic activity measurements. We show that a uniform layer was obtained by activating the oxide before immobilization. X-ray Photoelectron Spectroscopy measurements carried out on bulk oxide showed that the silicon substrate signal was fully screened after the enzyme deposition showing the absence of uncovered surface regions. The enzyme presence was detected monitoring both the C 1s and N 1s signals. Finally, enzymatic activity measurements confirmed that the glucose oxidase activity was preserved after immobilization and maintained after three months of shelf life if the sample was properly stored. The importance of using porous silicon oxide to maximize the surface area was also evidenced.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA