1.
Br J Ophthalmol ; 90(9): 1094-7, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16687451

RESUMEN

AIM: To study possible causes of an outbreak of severe endophthalmitis after planned extracapsular cataract surgery in Medan, Indonesia. METHODS: In a 3 week period in November 2001, 17 of 43 patients developed signs of endophthalmitis after planned extracapsular cataract surgery. A search for possible causes was undertaken 4 months later. RESULTS: In autoclaved stored distilled water used to dissolve acetylcholine (used in 16 of 17 patients with endophthalmitis) a high amount of endotoxin was detected in a human blood essay, as well as a small number of non-typeable Pseudomonas spp. CONCLUSIONS: These findings suggest that distilled water used as solvent for acetylcholine was responsible for this outbreak of endophthalmitis. As a consequence, we now rely on solvents that are regularly checked for impurities such as an intravenous infusion fluid, rather than on vials with distilled water that is presumed to be sterile and kept for some time.


Asunto(s)
Extracción de Catarata , Brotes de Enfermedades , Contaminación de Medicamentos , Endoftalmitis/etiología , Infecciones Bacterianas del Ojo/etiología , Microbiología del Agua , Acetilcolina , Infección Hospitalaria/epidemiología , Infección Hospitalaria/etiología , Endoftalmitis/epidemiología , Endotoxinas/efectos adversos , Infecciones Bacterianas del Ojo/epidemiología , Humanos , Indonesia/epidemiología , Complicaciones Posoperatorias , Pseudomonas/aislamiento & purificación , Infecciones por Pseudomonas/epidemiología , Infecciones por Pseudomonas/etiología , Soluciones
2.
Eye (Lond) ; 20(12): 1345-51, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16179931

RESUMEN

PURPOSE: To compare the accuracy of the potential acuity meter (PAM) and the illuminated near card (INC) in patients undergoing phacoemulsification. METHODS: During presurgical evaluations, both PAM and INC were tested on each study patient following dilation. Patients then rated the subjective ease of use of each test. Best spectacle-corrected visual acuity (BSCVA) was recorded at 4 and 12 weeks postoperatively. McNemar's chi(2) test for paired associations was used to analyse categorical data; paired t-tests were used for continuous variables. RESULTS: Overall, the INC was more likely than the PAM to predict BSCVA within one Snellen line (P=0.002), but this difference decreased for accuracy within two lines. The PAM predicted BSCVA within one line in 87 (70.7%) eyes, as compared to 102 (82.9%) eyes by the INC. The PAM was accurate within two lines in 109 (88.6%) eyes; the INC was accurate in 115 (93.5%) eyes. The PAM was more likely to underpredict potential acuity (P<0.001), while the INC was more likely to overpredict (P=0.004) or give exact predictions of BSCVA (P<0.001). Accuracy of the INC declined in eyes with macular comorbidity. The PAM and INC were rated as 'easy' tests by 54 (45.4%) and 93 (78.2%) patients, respectively. CONCLUSIONS: Both the PAM and the INC were useful for predicting BSCVA after phacoemulsification, but the PAM was more likely to underestimate potential acuity. The INC was easier for patients to use, and had better accuracy than the PAM in patients without macular comorbidity, but was more likely to overestimate potential acuity.


Asunto(s)
Facoemulsificación , Pruebas de Visión/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Femenino , Humanos , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Sensibilidad y Especificidad , Agudeza Visual