Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am J Ophthalmol Case Rep ; 34: 102066, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38741579

RESUMEN

Purpose: This case report details the diagnostic process for a patient with an initial diagnosis of scleritis who was unresponsive to typical treatment modalities, culminating in the identification of a cavernous sinus dural arteriovenous fistula (CS-DAVF). The case highlights the role of anterior segment optical coherence tomography angiography (OCTA) in the diagnosis of this vascular anomaly and in monitoring the response to treatment. Observations: A 45-year-old man with persistently elevated intraocular pressure (IOP) and ocular congestion in the left eye was unresponsive to treatment for scleritis. The persistent ocular symptoms and new-onset tinnitus prompted further investigation. Anterior segment OCTA revealed vascular anomalies, and magnetic resonance imaging confirmed a CS-DAVF. The patient underwent endovascular treatment for the CS-DAVF. This intervention led to a significant reduction in IOP in the left eye and the resolution of ocular congestion. Conclusions and importance: This case highlights the diagnostic complexities of ophthalmic symptoms that mimic those of other conditions. Furthermore, it demonstrates the essential role of anterior segment OCTA in the accurate diagnosis and effective management of CS-DAVF and highlights the need for comprehensive diagnostic approaches in ophthalmology.

2.
Br J Ophthalmol ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38485215

RESUMEN

BACKGROUND: Artificial intelligence (AI) in medical imaging diagnostics has huge potential, but human judgement is still indispensable. We propose an AI-aided teaching method that leverages generative AI to train students on many images while preserving patient privacy. METHODS: A web-based course was designed using 600 synthetic ultra-widefield (UWF) retinal images to teach students to detect disease in these images. The images were generated by stable diffusion, a large generative foundation model, which we fine-tuned with 6285 real UWF images from six categories: five retinal diseases (age-related macular degeneration, glaucoma, diabetic retinopathy, retinal detachment and retinal vein occlusion) and normal. 161 trainee orthoptists took the course. They were evaluated with two tests: one consisting of UWF images and another of standard field (SF) images, which the students had not encountered in the course. Both tests contained 120 real patient images, 20 per category. The students took both tests once before and after training, with a cool-off period in between. RESULTS: On average, students completed the course in 53 min, significantly improving their diagnostic accuracy. For UWF images, student accuracy increased from 43.6% to 74.1% (p<0.0001 by paired t-test), nearly matching the previously published state-of-the-art AI model's accuracy of 73.3%. For SF images, student accuracy rose from 42.7% to 68.7% (p<0.0001), surpassing the state-of-the-art AI model's 40%. CONCLUSION: Synthetic images can be used effectively in medical education. We also found that humans are more robust to novel situations than AI models, thus showcasing human judgement's essential role in medical diagnosis.

4.
Case Rep Ophthalmol ; 15(1): 129-135, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38322312

RESUMEN

Introduction: This case report aims to shed light on a rare presentation of familial exudative vitreoretinopathy (FEVR) co-existing with a large full-thickness macular hole (FTMH) in a 16-year-old male and discuss its successful surgical management, thereby adding to the limited existing knowledge on this topic. Case Presentation: Over an 8-month period, the patient had experienced progressively worsening visual blurring and distortion in his left eye. Following a comprehensive examination, diagnosis confirmed FEVR and an accompanying large FTMH. It was hypothesized that this unusual manifestation resulted from the tractional forces exerted by a thick posterior vitreous membrane and a thin epiretinal membrane - a distinctive attribute of FEVR. The patient underwent surgical intervention, which included pars plana vitrectomy (PPV), internal limiting membrane (ILM) peeling, gas tamponade, and the inverted ILM flap technique. Postoperative outcomes were favorable, with the FTMH successfully closed and substantial improvement observed in the patient's visual acuity at the 3-month follow-up visit. Conclusion: This case report highlights a rare association of FEVR with FTMH, thereby broadening our understanding of potential complications in patients with FEVR. The successful surgical intervention reinforces the utility of the PPV and the inverted ILM flap technique in managing such complications. It underscores the need for clinicians to maintain vigilance for such atypical manifestations in FEVR patients.

5.
Sci Rep ; 13(1): 22884, 2023 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-38129456

RESUMEN

This study aimed to analyze the trends and factors influencing the number of ophthalmic surgeries in Japan using the open data from the National Database of Health Insurance Claims and Specific Health Checkups of Japan published by the Ministry of Health, Labour and Welfare. We calculated the number of cataract, glaucoma, and vitreoretinal surgeries, categorized by sex, age, and surgical type, for the fiscal years (FY) 2014 to 2020. The number of cataract surgeries remained stable at approximately 1.45 million cases from FY 2014 to 2018, increased to nearly 1.6 million cases in FY 2019, and decreased to 1.45 million cases in FY 2020. Among glaucoma surgeries, surgical treatments were increased 1.8 times over 7 years, from 33,000 to 60,000 cases. Laser treatment remained steady at around 55,000 cases from FY 2014 to 2017 and then increased to approximately 60,000 cases. The number of vitreoretinal surgeries was increased 1.2 times from FY 2014 to 2019, from 120,000 to 140,000, and decreased to 130,000 by FY 2020. Trends in ophthalmic surgeries over the past 7 years may be influenced by population aging, minimally invasive surgery, and the coronavirus disease pandemic. These findings have implications on surgical decision-making and resource allocation.


Asunto(s)
Extracción de Catarata , Catarata , Glaucoma , Humanos , Anciano , Japón/epidemiología , Seguro de Salud
6.
Am J Ophthalmol Case Rep ; 32: 101914, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37654426

RESUMEN

Purpose: This case report aims to describe the detailed time course of eccentric macular hole (MH) formation following pars plana vitrectomy (PPV) for epiretinal membrane (ERM) treatment, using optical coherence tomography (OCT) images. Observations: A 60-year-old male patient presented to our hospital with complaints of blurred vision and distortion in his left eye. He was diagnosed with an ERM in the affected eye and subsequently underwent PPV with internal limiting membrane peeling. The patient's initial postoperative course was unremarkable; however, one month later, macular edema worsened, as evidenced by OCT findings. Initially, the edema was observed in both nasal and temporal to the fovea. However, four months postoperatively, the retina fluid in the area nasal to the fovea resolved, and the resolution was delayed in the area temporal to the fovea. At 18 months postoperatively, an eccentric macular hole was detected in the temporal to the fovea. The patient remained asymptomatic, and at the two-year follow-up, the eccentric macular hole demonstrated no signs of enlargement. Conclusions and Importance: This case demonstrates the progression of an unusual asymptomatic parafoveal full-thickness retinal hole after PPV for ERM treatment. Since the development of this condition may occur over a more extended postoperative period than previously reported, long-term patient monitoring is essential following ERM or MH surgery.

7.
Artículo en Inglés | MEDLINE | ID: mdl-37769245

RESUMEN

PURPOSE: To describe a rare case of Epstein-Barr virus (EBV)-positive primary vitreoretinal lymphoma (PVRL) in an immunosuppressed patient. METHODS: Observational case report. RESULTS: A 64-year-old man under immunosuppressive therapy for rheumatic arthritis was referred for 2-month of blurred vision and decreased visual acuity in the right eye. Only mutton-fat keratic precipitates and mild vitreous opacity were found in the right eye without (sub-)retinal or sub-retinal pigment epithelial lesions. Vitreous biopsy and systemic workup suggested the diagnosis of PVRL of diffuse large B cell lymphoma (DLBCL) subform. Neoplastic cells stained positive for EBV antigens, EBV-encoded small RNA and Epstein-Barr nuclear antigen 2, consistent with EBV-positive DLBCL. Intravitreal methotrexate was effective in improving ocular symptoms. CONCLUSION: Our case provided evidence on the association of EBV infection with PVRL.

8.
Sci Rep ; 12(1): 19394, 2022 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-36371596

RESUMEN

We compared the visual performance of a diffractive bifocal intraocular lens (IOL) with + 4.0 D near addition (ZMB00 [Johnson & Johnson Surgical Vision]) and a rotationally asymmetric refractive IOL with + 1.5 D near addition (LS-313 MF15 [Teleon Surgical BV]) 10 weeks after cataract patients' last surgery for bilateral ZMB00 or LS-313 MF15 implantation between 2011 and 2020, with the lenses of each eye implanted within 3 months of each other. The ZMB00 and LS-313 MF15 groups comprised 1326 eyes of 663 patients (age: 67.0 ± 7.8 years; females/males, 518/145) and 448 eyes of 224 patients (73.6 ± 7.0 years; females/males, 125/99), respectively. A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter, ensured statistical validity. Compared to LS-313 MF15, ZMB00 achieved significantly superior uncorrected near visual acuity, reduced higher-order aberrations (ocular/internal, scaled to a 4-mm pupil; Wavefront_4_post_Ocular_Total Higher-Order Aberration/Third/Fourth/Trefoil/Coma/Tetrafoil/Spherical, Wavefront_4_post_Internal_Astigmatism/Total Higher-Order Aberration/Third/Trefoil/Coma/Tetrafoil/Spherical), and superior distance and near spectacle independence (p < 0.00068, Wald test). Contrast sensitivity, measured without (visual angle of the test target: 6.3°/4.0°/2.5°/1.6°/1.0°/0.7°) or with glare (4.0°/2.5°/1.6°/1.0°/0.7°), was significantly better in the LS-313 MF15 than the ZMB00 group (p < 0.00068, Wald test).


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Astigmatismo/cirugía , Implantación de Lentes Intraoculares , Anteojos , Coma , Refracción Ocular , Trastornos de la Visión/cirugía , Diseño de Prótesis
9.
Spine J ; 21(10): 1652-1658, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33722728

RESUMEN

BACKGROUND CONTEXT: Accurate diagnosis of osteoporotic vertebral fracture (OVF) is important for improving treatment outcomes; however, the gold standard has not been established yet. A deep-learning approach based on convolutional neural network (CNN) has attracted attention in the medical imaging field. PURPOSE: To construct a CNN to detect fresh OVF on magnetic resonance (MR) images. STUDY DESIGN/SETTING: Retrospective analysis of MR images PATIENT SAMPLE: This retrospective study included 814 patients with fresh OVF. For CNN training and validation, 1624 slices of T1-weighted MR image were obtained and used. OUTCOME MEASURE: We plotted the receiver operating characteristic (ROC) curve and calculated the area under the curve (AUC) in order to evaluate the performance of the CNN. Consequently, the sensitivity, specificity, and accuracy of the diagnosis by CNN and that of the two spine surgeons were compared. METHODS: We constructed an optimal model using ensemble method by combining nine types of CNNs to detect fresh OVFs. Furthermore, two spine surgeons independently evaluated 100 vertebrae, which were randomly extracted from test data. RESULTS: The ensemble method using VGG16, VGG19, DenseNet201, and ResNet50 was the combination with the highest AUC of ROC curves. The AUC was 0.949. The evaluation metrics of the diagnosis (CNN/surgeon 1/surgeon 2) for 100 vertebrae were as follows: sensitivity: 88.1%/88.1%/100%; specificity: 87.9%/86.2%/65.5%; accuracy: 88.0%/87.0%/80.0%. CONCLUSIONS: In detecting fresh OVF using MR images, the performance of the CNN was comparable to that of two spine surgeons.


Asunto(s)
Inteligencia Artificial , Fracturas Osteoporóticas , Humanos , Imagen por Resonancia Magnética , Fracturas Osteoporóticas/diagnóstico por imagen , Estudios Retrospectivos , Columna Vertebral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...