Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 262
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-38642290

RESUMEN

Despite guideline-based recommendation of the interchangeable use of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) to guide revascularization decision-making, iFR/FFR could demonstrate different physiological or clinical outcomes in some specific patient or lesion subsets. Therefore, we sought to investigate the impact of difference between iFR and FFR-guided revascularization decision-making on clinical outcomes in patients with left main disease (LMD). In this international multicenter registry of LMD with physiological interrogation, we identified 275 patients in whom physiological assessment was performed with both iFR/FFR. Major adverse cardiovascular event (MACE) was defined as a composite of death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The receiver-operating characteristic analysis was performed for both iFR/FFR to predict MACE in respective patients in whom revascularization was deferred and performed. In 153 patients of revascularization deferral, MACE occurred in 17.0% patients. The optimal cut-off values of iFR and FFR to predict MACE were 0.88 (specificity:0.74; sensitivity:0.65) and 0.76 (specificity:0.81; sensitivity:0.46), respectively. The area under the curve (AUC) was significantly higher for iFR than FFR (0.74; 95%CI 0.62-0.85 vs. 0.62; 95%CI 0.48-0.75; p = 0.012). In 122 patients of coronary revascularization, MACE occurred in 13.1% patients. The optimal cut-off values of iFR and FFR were 0.92 (specificity:0.93; sensitivity:0.25) and 0.81 (specificity:0.047; sensitivity:1.00), respectively. The AUCs were not significantly different between iFR and FFR (0.57; 95%CI 0.40-0.73 vs. 0.46; 95%CI 0.31-0.61; p = 0.43). While neither baseline iFR nor FFR was predictive of MACE in patients in whom revascularization was performed, iFR-guided deferral seemed to be safer than FFR-guided deferral.

4.
Eur Heart J Open ; 4(2): oeae018, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38529170

RESUMEN

Aims: Current evidence on the prognostic value of exercise stress echocardiography (ESE) in asymptomatic patients with low-gradient severe aortic stenosis (AS) is limited. Therefore, this study aimed to elucidate its prognostic implications for patients with low-gradient severe AS and determine the added value of ESE in risk stratification for this population. Methods and results: This retrospective observational study included 122 consecutive asymptomatic patients with either moderate [mean pressure gradient (MPG) < 40 mmHg and aortic valve area (AVA) 1.0-1.5 cm2] or low-gradient severe (MPG < 40 mmHg and AVA < 1.0 cm2) AS and preserved left ventricular ejection fraction (≥50%) who underwent ESE. All patients were followed up for AS-related events. Of 143 patients, 21 who met any exclusion criteria, including early interventions, were excluded, and 122 conservatively managed patients [76.5 (71.0-80.3) years; 48.3% male] were included in this study. During a median follow-up period of 989 (578-1571) days, 64 patients experienced AS-related events. Patients with low-gradient severe AS had significantly lower event-free survival rates than those with moderate AS (log-rank test, P < 0.001). Multivariable Cox regression analysis showed that the mitral E/e' ratio during exercise was independently associated with AS-related events (hazard ratio = 1.075, P < 0.001) in patients with low-gradient severe AS. Conclusion: This study suggests that asymptomatic patients with low-gradient severe AS have worse prognoses than those with moderate AS. Additionally, the mitral E/e' ratio during exercise is a useful parameter for risk stratification in patients with low-gradient severe AS.

5.
Circ J ; 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38311419

RESUMEN

BACKGROUND: High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs.Methods and Results: The amount of adipose tissue adjacent to the device and anteroposterior diameter at the basal heart region were measured preoperatively using chest CT. We examined the correlation between these measurements and shock impedance at the conversion test. We enrolled 43 patients with S-ICDs (mean [±SD] age 54±15 years; body mass index 23±4 kg/m2; PRAETORIAN score 30-270 points; amount of adipose tissue 1,250±716 cm3), who underwent intraoperative conversion tests by inducing ventricular fibrillation, which was terminated with a 65-J shock. A sufficient concordance correlation coefficient was observed between the shock impedance and the amount of adipose tissue (r=0.616, P<0.01) and anteroposterior diameter (r=0.645, P<0.01). In multiple regression analysis, the amount of adipose tissue (ß=0.439, P=0.009) and anteroposterior diameter (ß=0.344, P=0.038) were identified as independent predictive factors of shock impedance. CONCLUSIONS: The preoperative CT-measured amount of adipose tissue and basal heart anteroposterior diameter are independent predictors of shock impedance. These parameters may be more accurate in identifying higher shock impedance in patients with S-ICDs.

6.
JACC Case Rep ; 29(4): 102216, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38379648

RESUMEN

A 70-year-old patient with paroxysmal atrial fibrillation underwent left atrial appendage closure. The patient experienced transient hypotension during device implantation. The procedure was abandoned because of ST-T-wave changes on electrocardiography and elevated coronary flow velocity on transesophageal echocardiography, which indicated that the device caused coronary artery compression.

7.
Circ J ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38220206

RESUMEN

BACKGROUND: This study aimed to clarify the effects of exercise-based cardiac rehabilitation (CR) on patients with heart failure.Methods and Results: Patients were divided into groups according to intervention duration (<6 and ≥6 months). We searched for studies published up to July 2023 in Embase, MEDLINE, PubMed, and the Cochrane Library, without limitations on data, language, or publication status. We included randomized controlled trials comparing the efficacy of CR and usual care on mortality, prehospitalization, peak oxygen uptake (V̇O2), and quality of life. Seventy-two studies involving 8,495 patients were included in this review. It was found that CR reduced the risk of rehospitalization for any cause (risk ratio [RR] 0.80; 95% confidence interval [CI] 0.70-0.92) and for heart failure (RR 0.88; 95% CI 0.78-1.00). Furthermore, CR was found to improve exercise tolerance (measured by peak V̇O2and the 6-min walk test) and quality of life. A subanalysis performed based on intervention duration (<6 and ≥6 months) revealed a similar trend. CONCLUSIONS: Our meta-analysis showed that although CR does not reduce mortality, it is effective in reducing rehospitalization rates and improving exercise tolerance and quality of life, regardless of the intervention duration.

8.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37500393

RESUMEN

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estudios de Factibilidad , Medios de Contraste/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/terapia , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento
9.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37438144

RESUMEN

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Angiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Estimación de Kaplan-Meier , Riñón/diagnóstico por imagen , Resultado del Tratamiento
10.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008428

RESUMEN

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Cateterismo Cardíaco
11.
Echocardiography ; 41(1): e15712, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37937359

RESUMEN

BACKGROUNDS: There are limited data on the clinical relevance of transvalvular flow rate (Qmean ) at rest (Qrest) and at peak stress (Qstress ) during dobutamine stress echocardiography (DSE) in patients with low-gradient severe aortic stenosis (LG-SAS). METHODS: We retrospectively analyzed the clinical data of patients with LG-SAS who underwent DSE. LG-SAS was defined as an aortic valve (AV) area index of < .6 cm2 /m2 and a mean AV pressure gradient (AVPG) of < 40 mm Hg. The primary endpoint included all-cause death and heart failure hospitalization. RESULTS: Of 100 patients (mean age 79.5 ± 7.3 years; men, 45.0%; resting left ventricular ejection fraction [LVEF] 52.1% ± 15.9%; resting stroke volume index 35.8 ± 7.7 mL/m2 ; Qrest 171.8 ± 34.9 mL/s), the primary endpoint occurred in 51 patients during a median follow-up of 2.84 (interquartile range 1.01-5.21) years. When the study patients were divided into three subgroups based on Qrest and Qstress , the multivariate analysis showed that Qrest < 200 mL/s and Qstress ≥200 mL/s (hazard ratio 3.844; 95% confidence interval 1.143-12.930; p = .030), as well as Qrest and Qstress < 200 mL/s (hazard ratio 9.444; 95% confidence interval 2.420-36.850; p = .001), were significantly associated with unfavorable outcomes with Qrest and Qstress ≥200 mL/s as a reference after adjusting for resting LVEF, resting mean AVPG, chronic kidney disease, New York Heart Association functional class III/IV, and AV replacement. CONCLUSIONS: Flow conditions based on the combination of Qrest and Qstress are helpful for risk stratification in LG-SAS patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Función Ventricular Izquierda , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Volumen Sistólico , Pronóstico , Ecocardiografía de Estrés , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Válvula Aórtica/diagnóstico por imagen , Índice de Severidad de la Enfermedad
13.
Am J Cardiol ; 210: 259-265, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37875233

RESUMEN

Aortic stenosis is a prevalent valvular heart disease, especially in the older people. They often coexist with other co-morbidities, and noncardiac surgery carries a higher risk because of the underlying valve condition. Despite the growing concern about the safety and optimal management of noncardiac surgery post-transcatheter aortic valve replacement (TAVR), there is limited evidence on this matter. This study aims to assess the clinical outcomes of noncardiac surgeries after TAVR. This retrospective study included 718 patients who underwent TAVR. Of these, 36 patients underwent noncardiac surgery after TAVR. The primary end point was the incidence of cardiovascular adverse events post-TAVR and the secondary end point was the incidence of structural valve deterioration. Composite end points included disabling stroke, heart failure requiring hospitalization, and cardiac death as defined by Valve Academic Research Consortium 3. Most of these surgeries were orthopedic and classified as intermediate risk. All noncardiac surgeries were performed without perioperative adverse events. There was no observed structural valve deterioration, and the incidence of composite end points did not significantly differ between the surgical and nonsurgical groups during the follow-up period. Noncardiac surgery after TAVR can be performed safely and does not have a negative impact on prognosis. Further studies are warranted to determine the optimal strategy for noncardiac surgery after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Prevalencia , Factores de Riesgo , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
14.
Circ Rep ; 5(12): 442-449, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38073869

RESUMEN

Background: A high score for controlling nutritional status (CONUT) due to poor nutritional status has been associated with adverse outcomes in patients with chronic heart failure. However, because little is known about the effect of CONUT score on mortality rates after transcatheter mitral valve repair, we evaluated nutrition screening tools for prognosis prediction in patients undergoing transcatheter mitral valve repair using the MitraClipTM system. Methods and Results: We retrospectively analyzed 148 patients with severe mitral regurgitation (MR) who underwent MitraClipTM implantation between April 2018 and April 2021. The preprocedural CONUT scores were assessed at the time of hospitalization, the primary outcome was all-cause death, and the analysis was of the mortality and incidence rates of cardiac events 1 year post-operation. Functional MR was of ischemic origin in the majority of patients (69.6%), with a mean left ventricular ejection fraction of 48.9±15.8%. Kaplan-Meier curves indicated that all-cause death was significantly worse in the high-CONUT score group than in the low-CONUT score group. Cox hazard analysis showed a significant association between all-cause death and CONUT score, as well as MitraScore. Conclusions: Preprocedural CONUT score, as well as MitraScore, in patients undergoing transcatheter edge-to-edge mitral valve repair may predict an increased risk of all-cause death. This knowledge should allow the heart team to accurately assess the clinical implications and prognostic benefits of the procedure in individual patients.

15.
Int Heart J ; 64(6): 1157-1161, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-37967987

RESUMEN

A 59-year-old man who had been diagnosed with human immunodeficiency virus-associated cardiomyopathy was referred for catheter ablation of ventricular tachycardia (VT). An electrocardiogram (ECG) waveform revealed that the clinical VT originated from the epicardium. A deceleration zone (DZ) was identified on an isochronal late activation map. Moreover, 2 forms of monomorphic VT were induced by different cycle length burst pacings from near the DZ. The morphologies of the 2 VTs with an identical cycle length were very likely to use a shared common pathway with bi-directional conduction around the slow conduction area in the left ventricle posterolateral small epicardial surface area. After ablation of the DZ, the VT was uninducible.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Taquicardia Ventricular , Masculino , Humanos , Persona de Mediana Edad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Arritmias Cardíacas/cirugía , Frecuencia Cardíaca/fisiología , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Resultado del Tratamiento
16.
Sci Rep ; 13(1): 20602, 2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37996502

RESUMEN

Weather conditions influence the incidence of cardiovascular disease. However, few studies have investigated the association between weather temperature and humidity and cerebrovascular disease hospitalizations in a super-aging society. We included 606,807 consecutive patients with cerebrovascular disease admitted to Japanese acute-care hospitals between 2015 and 2019. The primary outcome was the number of cerebrovascular disease hospitalizations per day. Multilevel mixed-effects linear regression models were used to estimate the association of mean temperature and humidity, 1 day before hospital admission, with cerebrovascular disease hospitalizations, after adjusting for air pollution, hospital, and patient demographics. Lower mean temperatures and humidity < 70% or humidity ≧ 70% are associated with an increased incidence of cerebrovascular disease hospitalization (coefficient, - 1.442 [- 1.473 to - 1.411] per °C, p < 0.001, coefficient, - 0.084 [- 0.112 to - 0.056] per%, p < 0.001, and coefficient, 0.136 [0.103 to 0.168] per %, p < 0.001, respectively). Lower mean temperatures and extremely lower or higher humidity are associated with an increased incidence of cerebrovascular disease hospitalization in a super-aging society.


Asunto(s)
Trastornos Cerebrovasculares , Hospitalización , Humanos , Envejecimiento , Trastornos Cerebrovasculares/epidemiología , Humedad , Temperatura , Tiempo (Meteorología)
17.
Pacing Clin Electrophysiol ; 46(12): 1643-1651, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37904603

RESUMEN

BACKGROUND: Predictors of worsening atrioventricular valve regurgitation and left ventricular (LV) systolic function after implantation of a leadless pacemaker (LPM) remain unclear compared with those of a transvenous pacemaker (TPM). METHODS: We retrospectively analyzed 205 patients who were newly implanted with a permanent pacemaker (119 LPMs and 86 TPMs) and underwent transthoracic echocardiography before and 8 ± 5 months after implantation. We evaluated the worsening of tricuspid and mitral regurgitation (TR and MR), defined as at least one-grade aggravation in severity, and changes in LV ejection fraction (LVEF). RESULTS: Worsening TR occurred more frequently in the LPM group compared to the TPM group (33% vs. 20%, p = .04); however, there was no significant difference between the two groups regarding worsening MR (26% vs. 18%, p = .18) and LVEF change (-2 ± 10% vs. -3 ± 8%, p = .40). In multivariable analysis, independent predictors for worsening TR, MR, and LVEF after implantation were found to be (1) the change from sinus rhythm at baseline to atrioventricular asynchronous right ventricular (RV) pacing (odds ratio [OR]: 5.68, 95% confidence interval [CI]: 1.94-16.70, p < .01); (2) the change from non-pacing ventricular contraction at baseline to RV pacing (OR: 2.42, 95% CI: 1.12-5.24, p = .02); and (3) a higher RV pacing burden (ß: -0.05, 95% CI: -0.08--0.02, p < .01), respectively. CONCLUSION: Worsening TR, MR, and LVEF after pacemaker implantation were not associated with the type of pacing device but loss of atrioventricular synchrony or dependency on RV pacing.


Asunto(s)
Insuficiencia de la Válvula Mitral , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Estimulación Cardíaca Artificial , Estudios Retrospectivos , Función Ventricular Izquierda , Insuficiencia de la Válvula Mitral/terapia
18.
Circ Rep ; 5(9): 358-364, 2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37693232

RESUMEN

Background: Very severe aortic stenosis (AS) has a poor prognosis even in asymptomatic patients, and asymptomatic very severe AS is a Class IIa indication for aortic valve replacement, although the safety and effectiveness of transcatheter aortic valve implantation (TAVI) for very severe AS is not well-established. Methods and Results: This study included 366 patients undergoing TAVI at a single center, with 85 and 281 patients in the very severe AS (peak velocity ≥5 m/s or mean pressure gradient (PG) ≥60 mmHg) and severe AS groups, respectively. Procedural and clinical outcomes at 1-year follow-up were compared between groups. The calcium scores were significantly higher in the very severe AS group (2,864.5 vs. 1,405.8 arbitrary units [AU] (P<0.001). Although the patient-prosthesis mismatch rate was higher in the very severe AS group (38.3% vs. 25.7%; P=0.029), there was no significant difference in the early safety and clinical efficacy between the groups (16.5% vs. 17.1% and 12.0% vs. 18.9%, respectively). Similarly, there was no significant difference in all-cause mortality at 1 year (4.8% vs. 9.8%). Conclusions: Despite a higher incidence of prosthesis-patient mismatch in those with very severe AS, the procedural and clinical outcomes were comparable to those in patients with severe AS. TAVI may be a reasonable treatment option for very severe AS.

19.
Am J Cardiol ; 204: 130-139, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37541149

RESUMEN

Electrocardiogram (ECG) left ventricular hypertrophy (LVH) is associated with the prognosis of patients with aortic stenosis. However, the impact of the presence or absence of ECG-LVH on the clinical outcomes after transcatheter aortic valve implantation (TAVI) is limited. This study aimed to assess the prognostic value of ECG-LVH among patients with aortic stenosis treated by TAVI. A total of 1,667 patients who underwent TAVI were prospectively enrolled into the OCEAN-TAVI (Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation) registry. A total of 1,446 patients (mean age 84 years; 29.9% men) were analyzed. The Sokolow-Lyon index was used to determine the presence of ECG-LVH. LVH was also assessed using transthoracic echocardiography (TTE). We investigated the association between ECG-LVH and all-cause and cardiovascular mortality. This study identified ECG-LVH and TTE-LVH in 743 (51.5%) and 1,242 patients (86.0%), respectively. The Kaplan-Meier analysis revealed that all-cause mortality was significantly higher among patients without ECG-LVH than among those with ECG-LVH (log-rank p <0.001). In the multivariable analysis, the absence of ECG-LVH was independently associated with all-cause mortality (hazard ratio 1.98, 95% confidence interval 1.39 to 2.82, p <0.001), regardless of the presence or absence of TTE-LVH. Furthermore, the presence of TTE-LVH with the absence of ECG-LVH was observed in 575 patients (40%), which was associated with cardiovascular mortality (hazard ratio 2.84, 95% confidence interval 1.56 to 5.17, p <0.001). In conclusion, the absence of ECG-LVH was independently associated with an increased risk of all-cause mortality after TAVI. Risk stratification using both ECG-LVH and TTE-LVH is a useful predictor of adverse clinical outcomes after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Pronóstico , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/epidemiología , Hipertrofia Ventricular Izquierda/etiología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Sistema de Registros , Válvula Aórtica/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...