Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Europace ; 23(10): 1548-1558, 2021 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-33895833

RESUMEN

AIMS: Weight management seems to be beneficial for obese atrial fibrillation (AF) patients; however, randomized data are sparse. Thus, this study aimed to investigate the influence of weight reduction on AF ablation outcomes. METHODS AND RESULTS: SORT-AF is an investigator-sponsored, prospective, randomized, multicentre, and clinical trial. Patients with symptomatic AF (paroxysmal or persistent) and body mass index (BMI) 30-40 kg/m2 underwent AF ablation and were randomized to either weight-reduction (group 1) or usual care (group 2), after sleep-apnoea-screening and loop recorder (ILR) implantation. The primary endpoint was defined as AF burden between 3 and 12 months after AF ablation. Overall, 133 patients (60 ± 10 years, 57% persistent AF) were randomized to group 1 (n = 67) and group 2 (n = 66), respectively. Complications after AF-ablation were rare (one stroke and no tamponade). The intervention led to a significant reduction of BMI (34.9 ± 2.6-33.4 ± 3.6) in group 1 compared to a stable BMI in group 2 (P < 0.001). Atrial fibrillation burden after ablation decreased significantly (P < 0.001), with no significant difference regarding the primary endpoint between the groups (P = 0.815, odds ratio: 1.143, confidence interval: 0.369-3.613). Further analyses showed a significant correlation between BMI and AF recurrence for patients with persistent AF compared with paroxysmal AF patients (P = 0.032). CONCLUSION: The SORT-AF study shows that AF ablation is safe and successful in obese patients using continuous monitoring via ILR. Although the primary endpoint of AF burden after ablation did not differ between the two groups, the effects of weight loss and improvement of exercise activity were beneficial for obese patients with persistent AF demonstrating the relevance of life-style management as an important adjunct to AF ablation in this setting. TRIAL REGISTRATION NUMBER: NCT02064114.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento
2.
Arch Med Sci ; 16(5): 1022-1030, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32863990

RESUMEN

INTRODUCTION: Respiratory sinus arrhythmia (RSA) describes heart rate (HR) changes in synchrony with respiration. It is relevant for exercise capacity and mechanistically linked with the cardiac autonomic nervous system. After pulmonary vein isolation (PVI), the current therapy of choice for patients with paroxysmal atrial fibrillation (AF), the cardiac vagal tone is often diminished. We hypothesized that RSA is modulated by PVI in patients with paroxysmal AF. MATERIAL AND METHODS: Respiratory sinus arrhythmia, measured by using a deep breathing test and heart rate variability parameters, was studied in 10 patients (64 ±3 years) with paroxysmal AF presenting in stable sinus rhythm for their first catheter-based PVI. Additionally, heart rate dynamics before and after PVI were studied during sympathetic/parasympathetic coactivation by using a cold-face test. All tests were performed within 24 h before and 48 h after PVI. RESULTS: After PVI RSA (E/I difference: 7.9 ±1.0 vs. 3.5 ±0.6 bpm, p = 0.006; E/I ratio: 1.14 ±0.02 vs. 1.05 ±0.01, p = 0.003), heart rate variability (SDNN: 31 ±3 vs. 14 ±3 ms, p = 0.006; RMSSD: 17 ±2 vs. 8 ±2 ms, p = 0.002) and the HR response to sympathetic/parasympathetic coactivation (10.2 ±0.7% vs. 5.7 ±1.1%, p = 0.014) were diminished. The PVI-related changes in RSA correlated with the heart rate change during sympathetic/parasympathetic coactivation before vs. after PVI (E/I difference: r = 0.849, p = 0.002; E/I ratio: r = 0.786, p = 0.007). One patient with vagal driven arrhythmia experienced AF recurrence during follow-up (mean: 6.5 ±0.6 months). CONCLUSIONS: Respiratory sinus arrhythmia is reduced after PVI in patients with paroxysmal AF. Our findings suggest that this is related to a decrease in cardiac vagal tone. Whether and how this affects the clinical outcome including exercise capacity need to be determined.

3.
Cardiovasc Diagn Ther ; 9(Suppl 2): S247-S263, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31737533

RESUMEN

BACKGROUND: Ultra-high density mapping (HDM) is a promising tool in the treatment of patients with complex arrhythmias. In adults with congenital heart disease (CHD), rhythm disorders are among the most common complications but catheter ablation can be challenging due to heterogenous anatomy and complex arrhythmogenic substrates. Here, we describe our initial experience using HDM in conjunction with novel automated annotation algorithms in patients with moderate to great CHD complexity. METHODS: We studied a series of consecutive adult patients with moderate to great CHD complexity and an indication for catheter ablation due to symptomatic arrhythmia. HDM was conducted using the Rhythmia™ mapping system and a 64-electrode mini-basket catheter for identification of anatomy, voltage, activation pattern and critical areas of arrhythmia for ablation guidance. To investigate novel advanced mapping strategies, postprocedural signal processing using the Lumipoint™ software was applied. RESULTS: In 19 patients (53±3 years; 53% male), 21 consecutive ablation procedures were conducted. Procedures included ablation of atrial fibrillation (n=7; 33%), atrial tachycardia (n=11; 52%), atrioventricular accessory pathway (n=1; 5%), the atrioventricular node (n=1; 5%) and ventricular arrhythmias (n=4; 19%). A total of 23 supraventricular and 8 ventricular arrhythmias were studied with the generation of 56 complete high density maps (atrial n=43; ventricular n=11, coronary sinus n=2) and an average of 12,043±1,679 mapping points. Multiple arrhythmias were observed in n=7 procedures (33% of procedures; range of arrhythmias detected 2-4). A total range of 1-4 critical areas were defined per procedure and treated within a radiofrequency application time of 16 (interquartile range 12-45) minutes. Postprocedural signal processing using Lumipoint™ allowed rapid annotation of fractionated signals within specific windows of interest. This supported identification of a practical critical isthmus in 20 out of 27 completed atrial and ventricular tachycardia activation maps. CONCLUSIONS: Our findings suggest that HDM in conjunction with novel automated annotation algorithms provides detailed insights into arrhythmia mechanisms and might facilitate tailored catheter ablation in patients with moderate to great CHD complexity.

4.
Europace ; 20(1): 43-49, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-27742775

RESUMEN

Introduction: Comparative data of early recurrence rates of atrial fibrillation (ERAF) following second-generation cryoballoon (CB-G2) and radiofrequency current (RFC) ablation for pulmonary vein isolation (PVI) in paroxysmal AF (PAF) are rare. We randomized PAF patients into either PVI with CB-G2 (group 1) or PVI with a combined RFC-approach applying contact force (CF) with the endpoint of unexcitability (group 2) to investigate ERAF. Methods and results: In group 1 (n = 30), CB-G2-PVI was performed. After CF-PVI in group 2 (n = 30), bipolar pacing on the ablation line and additional ablation until unexcitability was conducted. Follow-up included 48 h of in-hospital monitoring followed by 5-day Holter ECGs 1, 2, 3, 6, 12 months postablation to evaluate ERAF. Acute PVI was reached in 100% of group 2 and in 99% of group 1. Shorter procedure durations (98.0 ± 21.9 vs. 114.3 ± 18.7 min, P < 0.05) but extended fluoroscopy times (15.4 ± 3.9 vs. 10.0 ± 4.3 min, P < 0.05) were found in the CB-G2 group. Ten non-severe complications occurred (6 vs. 4 in group 1 and 2, P = 0.73). In group 2, five patients suffered from ERAF vs. seven patients in group 1 (P = 0.67). The time until the occurrence of ERAF was shorter in group 2 (1 day (q1-q3: 1-4.5)) when compared with group 1 (22 (q1-q3: 6-54) days, P = 0.025). Conclusion: ERAF rates were equal among groups; however, they occurred earlier in the initial phase after RFC ablation when compared with CB-G2. PVI utilizing cryoablation is associated with shorter procedure durations but extended fluoroscopy time while being similarly secure.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Fluoroscopía , Alemania , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Proyectos Piloto , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Radiografía Intervencional , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA