Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiography (Lond) ; 30(1): 282-287, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38041916

RESUMEN

INTRODUCTION: The utilization of radiation shielding material positioned between the both breasts are crucial for the reduction of glandular dose and the safeguarding of the contralateral breast during mammographic procedures. This study proposes an alternative substance for shielding the contralateral breast from radiation exposure during mammography screening. METHODS: In this study, we present an analysis of the shielding effectiveness of transparent glass that has been doped with Tantalum (V) oxide encoded as BTZT6. The evaluation of this shielding material was conducted using the MCNPX code, specifically for the ipsilateral and contralateral breasts. The design of the left and right breast phantoms involved the creation of three-layer heterogeneous breast phantoms, consisting of varying proportions of glandular tissue (25%, 50%, and 75%). The design of BTZT6 and lead-acrylic shielding screens is implemented using the MCNPX code. The comparative analysis of dose outcomes is conducted to assess the protective efficacy of BTZT6 and lead-acrylic shielding screens. RESULTS: The utilization of BTZT6 shielding material resulted in a reduction in both breast dose and skin dose exposure when compared to the lead-acrylic shield. CONCLUSION: Based on the findings acquired, the utilization of BTZT6 shielding material screens during mammography procedures involving X-rays with energy levels ranging from 26 to 30 keV is associated with a decrease in radiation dose. IMPLICATIONS FOR PRACTICE: It can be inferred that the utilization of BTZT6 demonstrates potential efficacy in mitigating excessive radiation exposure to the breasts and facilitating the quantification of glandular doses in mammography procedures.


Asunto(s)
Tantalio , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Mamografía/métodos , Mama/diagnóstico por imagen
2.
Radiat Prot Dosimetry ; 192(1): 61-68, 2020 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-33300563

RESUMEN

In this study, cosmic radiation doses were calculated for domestic and international flights departing from Istanbul and furthermore for domestic flights departing from Ankara using a software program called CARI-7A and also a mathematical method approach. Main parameters for calculating cosmic radiation are vertical cut-off rigidity, flight duration, latitude-longitude and altitude of the flight. Our calculation results agree with the measurements for domestic and international flights departing from Istanbul and Ankara.


Asunto(s)
Radiación Cósmica , Exposición Profesional , Exposición a la Radiación , Protección Radiológica , Aeronaves , Altitud , Exposición Profesional/análisis , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...