Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Nucl Med ; 48(11): e537-e538, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37703464

RESUMEN

ABSTRACT: Pulmonary hamartoma is the most common benign tumor of the lung and often discovered incidentally on imaging. We report the case of a 49-year-old woman recently diagnosed with left breast cancer with suspicious left axillary lymph nodes. 18 F-FDG PET/CT showed well-circumscribed, lobulated, low-attenuation soft tissue mass in the right lower lobe lung with mild to no significant metabolic activity. CT-guided biopsy showed the lesion composed of fat, cartilage, and smooth muscle, admixed with fibroconnective tissue. The findings are consistent with pulmonary hamartoma. The presence of fat in a well-circumscribed solitary pulmonary nodule along with low metabolic activity helps in the characterization of the lesion, which can alter patient management.


Asunto(s)
Hamartoma , Neoplasias Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Hamartoma/diagnóstico por imagen , Hamartoma/patología
2.
J Med Syst ; 41(10): 166, 2017 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-28900815

RESUMEN

One of the major issues in time-critical medical applications using wireless technology is the size of the payload packet, which is generally designed to be very small to improve the transmission process. Using small packets to transmit continuous ECG data is still costly. Thus, data compression is commonly used to reduce the huge amount of ECG data transmitted through telecardiology devices. In this paper, a new ECG compression scheme is introduced to ensure that the compressed ECG segments fit into the available limited payload packets, while maintaining a fixed CR to preserve the diagnostic information. The scheme automatically divides the ECG block into segments, while maintaining other compression parameters fixed. This scheme adopts discrete wavelet transform (DWT) method to decompose the ECG data, bit-field preserving (BFP) method to preserve the quality of the DWT coefficients, and a modified running-length encoding (RLE) scheme to encode the coefficients. The proposed dynamic compression scheme showed promising results with a percentage packet reduction (PR) of about 85.39% at low percentage root-mean square difference (PRD) values, less than 1%. ECG records from MIT-BIH Arrhythmia Database were used to test the proposed method. The simulation results showed promising performance that satisfies the needs of portable telecardiology systems, like the limited payload size and low power consumption.


Asunto(s)
Electrocardiografía , Algoritmos , Compresión de Datos , Procesamiento de Señales Asistido por Computador , Análisis de Ondículas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...