Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Int J Implant Dent ; 10(1): 14, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38507139

RESUMEN

PURPOSE: To comprehensively assess the existing literature regarding the rapidly evolving in vivo application of magnetic resonance imaging (MRI) for potential applications, benefits, and challenges in dental implant surgery. METHODS: Electronic and manual searches were conducted in PubMed MEDLINE, EMBASE, Biosis, and Cochrane databases by two reviewers following the PICOS search strategy. This involved using medical subject headings (MeSH) terms, keywords, and their combinations. RESULTS: Sixteen studies were included in this systematic review. Of the 16, nine studies focused on preoperative planning and follow-up phases, four evaluated image-guided implant surgery, while three examined artifact reduction techniques. The current literature highlights several MRI protocols that have recently investigated and evaluated the in vivo feasibility and accuracy, focusing on its potential to provide surgically relevant quantitative and qualitative parameters in the assessment of osseointegration, peri-implant soft tissues, surrounding anatomical structures, reduction of artifacts caused by dental implants, and geometric accuracy relevant to implant placement. Black Bone and MSVAT-SPACE MRI, acquired within a short time, demonstrate improved hard and soft tissue resolution and offer high sensitivity in detecting pathological changes, making them a valuable alternative in targeted cases where CBCT is insufficient. Given the data heterogeneity, a meta-analysis was not possible. CONCLUSIONS: The results of this systematic review highlight the potential of dental MRI, within its indications and limitations, to provide perioperative surgically relevant parameters for accurate placement of dental implants.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Implantación Dental Endoósea/métodos , Oseointegración , Imagen por Resonancia Magnética
2.
J Clin Pediatr Dent ; 48(2): 19-25, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38548629

RESUMEN

This study aims to investigate the impact of storage conditions for crown fragments (specifically, whether they were stored within a tooth rescue box or in tap water) on their adhesion to fractured teeth when subjected to two different adhesive systems (namely, total etch and self etch). Sixty maxillary premolars were sectioned to obtain tooth fragments. These fragments were stored briefly (2 hours) and reattached in the following groups: Group 1 (fragments stored in tooth rescue box and reattached with etch and rinse (E&R) technique), Group 2 (fragments stored in tap water and reattached with E&R technique), Group 3 (fragments stored in tooth rescue box and reattached with self-etch (SE) technique), and Group 4 (fragments stored in tap water and reattached SE technique). After reattachment, the bonded tooth fragments underwent thermal cycling (500 cycles, 5-55 °C) and bond strength testing using a universal testing machine. Two-way Analysis of Variance (ANOVA) and Tukey's tests were used for bond strength comparison (p ≤ 0.05). A two-parameter Weibull distribution was conducted to evaluate the reliability of the storage medium and adhesion modality on bond strength. The results showed that measured shear bond values (MPa ± Standard deviation (SD); arranged in descending order) for each group were: Group 2 (Tap water/E&R = 6.5 ± 2.1), Group 1 (Rescue box/E&R = 6.0 ± 2.5), Group 4 (Tap water/E&R = 5.1 ± 2.8), and Group 3 (Rescue box/SE = 3.6 ± 3.2). Significant differences were found only between Groups 2 and 3 (p = 0.002). In conclusion, storing crown fragments in a tooth rescue box did not significantly affect the shear bond strength of the restored tooth. However, fragments reattached using the self-etch technique showed comparable shear bond strength but a higher rate of adhesive failures compared to the E&R technique.


Asunto(s)
Recubrimiento Dental Adhesivo , Fracturas de los Dientes , Humanos , Reproducibilidad de los Resultados , Resinas Compuestas/química , Resinas Compuestas/farmacología , Agua/farmacología , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Cementos de Resina/farmacología , Ensayo de Materiales , Resistencia al Corte , Recubrimientos Dentinarios/química , Recubrimientos Dentinarios/farmacología , Dentina
3.
J Mech Behav Biomed Mater ; 151: 106395, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38244420

RESUMEN

OBJECTIVES: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS: The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).


Asunto(s)
Implantes Dentales , Prótesis Dental , Circonio , Soporte de Peso , Tornillos Óseos , Análisis de Varianza , Titanio , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Ensayo de Materiales , Coronas
4.
J Craniomaxillofac Surg ; 52(1): 117-126, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37891089

RESUMEN

This study aimed to compare preoperative data relevant to third molar surgery based on radiographic orthopantomography (OPG) and orthopantomogram-like MR images (MR-OPG), using five different MR protocols. X-ray-based OPG and OPG-like MRI reconstructions from DESS, SPACE-STIR, SPACE-SPAIR, T1-VIBE-Dixon, and UTE sequences were acquired in 11 patients undergoing third molar surgery, using a 15-channel mandibular coil. Qualitative (image quality, susceptibility to artifacts, positional relationship, contact/non-contact of the inferior alveolar nerve (IAN), relationship to maxillary sinus, IAN continuity, root morphology) and quantitative (tooth length, retromolar distance, distance to the IAN, and distance to the mandible margin) parameters of the maxillary and mandibular third molars were assessed regarding inter-reader agreement and quantitative discrepancies by three calibrated readers. Radiation-free MR-OPGs generated within clinically tolerable acquisition times, which exhibited high image quality and low susceptibility to artifacts, showed no significant differences compared with X-ray-based OPGs regarding the assessment of quantitative parameters. UTE MR-OPGs provided radiographic-like images and were best suited for assessing qualitative preoperative data (positional relationship, nerve contact/non-contact, and dental root morphology) relevant to third molar surgery. For continuous and focal nerve imaging, DESS MR-OPG was superior. MR-OPGs could represent a shift towards indication-specific and modality-oriented perioperative imaging in high-risk oral and maxillofacial surgery.


Asunto(s)
Diente Impactado , Traumatismos del Nervio Trigémino , Humanos , Tercer Molar/diagnóstico por imagen , Tercer Molar/cirugía , Rayos X , Radiografía Panorámica/métodos , Imagen por Resonancia Magnética/métodos , Diente Impactado/cirugía , Extracción Dental , Espectroscopía de Resonancia Magnética , Nervio Mandibular , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Mandíbula/inervación , Traumatismos del Nervio Trigémino/diagnóstico por imagen
5.
Clin Oral Investig ; 27(12): 7115-7141, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37910242

RESUMEN

OBJECTIVE: To systematically review studies on various occlusal splint materials and describe their mechanical and chemical properties. METHODS: MEDLINE (PubMed), Scopus, and Web of Science searches were conducted for in vitro studies focusing on occlusal splint materials. Two reviewers performed an assessment of the identified studies and data abstraction independently, and this was complimented by an additional hand search. The articles were limited to those in the English language that were published between January 1st, 2012, and December 1st, 2022. RESULTS: The initial search yielded 405 search results of which 274 were selected for full-text review following abstract evaluation. 250 articles that did not meet the inclusion criteria were excluded, and the remaining 25 articles (with 1 article identified from the reference lists of included articles) providing mechanical and chemical values were used in this review. Poly methyl methacrylate (PMMA) -based occlusal splint materials showed the highest values in terms of hardness, wear resistance, flexural strength, flexural modulus, e-modulus, and fracture toughness. The material group with the highest water sorption and water solubility was 3D printed (PR) splint materials. In addition, the lowest degree of double bond conversion was also observed in this group of materials. CONCLUSIONS: The outcome of this review suggests that mechanically and chemically acceptable properties can be attained with PMMA-based occlusal splint materials using both conventional and digital production methods. PR splint materials should not be considered as the primary choice for long-term treatments due to their low mechanical and chemical properties. CLINICAL RELEVANCE: This review provides clinical recommendations for selecting the appropriate material and fabrication method for occlusal splints while taking the patients' needs and the materials´ mechanical and chemical properties into account.


Asunto(s)
Ferulas Oclusales , Polimetil Metacrilato , Humanos , Resistencia Flexional , Férulas (Fijadores) , Agua
6.
J Mech Behav Biomed Mater ; 148: 106184, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37839334

RESUMEN

PURPOSE: This study investigated the impact of preparation design and material types on fracture strength in maxillary premolars endocrowns after thermodynamic aging. MATERIALS AND METHODS: Eighty two-rooted maxillary premolar crowns underwent endodontic treatment (N = 80, n = 10). The teeth were categorized into ten groups (4-mm deep with no intracanal extension lithium disilicate glass ceramic & multilayer zirconia endocrowns (LE0 & ZE0); 4-mm deep with 4-mm intracanal extension in one canal (LE1 & ZE1); 4-mm deep with 2-mm intracanal extensions in both canals (LE2 & ZE2); flat overlays with no endocore (LO & ZO); glass fiber reinforced post & core and crown (LC & ZC)). After cementation, all specimens were subjected to 1500 thermocycles and 1,200,000 chewing cycles with an axial occlusal load of 49 N. A static loading test was performed at a non-axial 45° loading using a universal testing machine and failure modes (Type I: restoration debonding; Type II: restoration fracture; Type III: restoration/tooth complex fracture above bone level; Type IV: restoration/tooth complex fracture below bone level) were evaluated using a stereoscope. Data were ananalzed using 2-way ANOVA and Tukey's tests (alpha = 0.05). RESULTS: The endocrowns manufactured from multilayered zirconia and pressed lithium disilicate glass ceramic exhibited a fracture load ranging between 1334 ± 332 N and 756 ± 150 N, with ZC presenting the highest and LE2 the lowest values. The differences were not statistically significant (p > 0.05). CONCLUSION: All endocrowns tested in this study performed similar considering the different designs and materials tested. The distribution of fracture modes did not differ significantly depending on the design of the restoration and the type of material used.


Asunto(s)
Resistencia Flexional , Fracturas de los Dientes , Humanos , Ensayo de Materiales , Diseño Asistido por Computadora , Circonio , Cerámica , Porcelana Dental , Análisis del Estrés Dental , Fracaso de la Restauración Dental
7.
Materials (Basel) ; 16(18)2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37763518

RESUMEN

This study aimed to evaluate the effects of surface treatments and resin cement on the adhesion of ceramic and ceramic-like materials to titanium. A total of 40 specimens (5 mm diameter) of each material (lithium disilicate glass ceramic (LDGC-IPS e.maxCAD), lithium silicate glass ceramic (LSGC-VITA Suprinity) and a polymer-infiltrated ceramic network (PICN-Vita Enamic)) were fabricated using CAD/CAM technologies. In total, 120 titanium (Ti) specimens were divided into 12 groups, and half of the titanium specimens were tribochemically coated using CoJet. The titanium and all-ceramic specimens were cemented using either Self-curing adhesive cement (SCAC-Panavia 21) or a Self-curing luting composite (SCLC-Multilink Hybrid Abutment). After 5000 cycles of thermal aging, the shear bond strength (SBS) test was conducted using a universal testing machine. The failure modes of the specimens were analyzed using stereomicroscopy, and additionally, the representative specimens were observed using Scanning Electron Microscopy. ANOVA was used for the statistical analysis (p < 0.05). The post-hoc Duncan test was used to determine significant differences between the groups. The mean SBS values (mean ± STD) ranged from 15 ± 2 MPa to 29 ± 6 MPa. Significantly higher SBS values were acquired when the titanium surface was tribochemically coated (p < 0.05). The SCLC showed higher SBS values compared to the SCAC. While the LDGC showed the highest SBS values, the PICN presented the lowest. The tribochemical coating on the cementation surfaces of the titanium increased the SBS values. The specimens cemented with the SCLC showed higher SBS values than those with the SCAC. Additionally, the SCLC cement revealed a more significant increase in SBS values when used with the LDGC. The material used for restoration has a high impact on SBS than those of the cement and surface conditioning.

8.
Materials (Basel) ; 16(14)2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37512206

RESUMEN

The clinical success of porcelain laminate veneers (PLVs) depends on many clinical and technical factors, from planning to execution, among which adhesive cementation is of significant importance. This procedure carries many risk factors if not optimally executed. The objective of this study was to document the clinical parameters affecting successful cementation procedures with a focus on the adhesive strength, integrity, and esthetics of the PLVs. A literature search was conducted through MEDLINE, complemented by a hand search using predefined keywords. Articles published in English between 1995 and 2023 were selected. According to this review, the success and longevity of PLVs rely in great part on the implementation of a precise cementation technique, starting from field isolation, adequate materials selection for adhesion, proper manipulation of the materials, the seating of the veneers, polymerization, and elimination of the excess cement. Several clinical steps performed before cementation, including treatment planning, preparation, impression, and adequate choice of the restorative material, could affect the quality of cementation. Scientific evidence suggests careful implementation of this process to achieve predictable outcomes with PLVs. The short- and long-term clinical success of adhesively luted PLVs is tributary to a deep understanding of the materials used and the implementation of clinical protocols. It is also contingent upon all the previous steps from case selection, treatment planning, and execution until and after the cementation.

10.
Sci Rep ; 13(1): 6228, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-37069287

RESUMEN

This prospective study aimed to present, compare, and evaluate the suitability of five different magnetic resonance imaging (MRI) protocols (3D double-echo steady-state (DESS), 3D fast spin echo short-tau inversion recovery (SPACE-STIR), 3D fast spin echo spectral attenuated inversion recovery (SPACE-SPAIR), volumetric interpolated breath-hold examination (T1-VIBE-Dixon), and ultrashort echo time (UTE)) and for orthopantomogram (OPG)-like MRI reconstructions using a novel mandibular coil. Three readers assessed MR-OPGs of 21 volunteers regarding technical image quality (4, excellent; 0, severely reduced), susceptibility to artifacts (3, absence; 0, massive), and visualization of anatomical structures in the oral cavity and surrounding skeletal structures (4, fine details visible; 0, no structures visible). Average image quality was good (3.29 ± 0.83) for all MRI protocols, with UTE providing the best image quality (3.52 ± 0.62) and no to minor artifacts (2.56 ± 0.6). Full diagnostic interpretability of the osseous structures is best in VIBE-Dixon and UTE MR-OPGs. DESS provided excellent visualization of the finest details of the nervous tissue (3.95 ± 0.22). Intra-reader and inter-reader agreement between the readers was good to excellent for all protocols (ICCs 0.812-0.957). MR-OPGs provide indication-specific accurate imaging of the oral cavity and could contribute to the early detection of pathologies, staging, and radiological follow-up of oral and maxillofacial diseases.


Asunto(s)
Operatoria Dental , Cirugía Bucal , Humanos , Radiografía Panorámica , Prueba de Estudio Conceptual , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos
11.
Materials (Basel) ; 16(6)2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-36984061

RESUMEN

The long-term success of ceramic laminate veneers (CLVs) is influenced by the marginal and internal fit of the restorations. However, studies comparing the fit of CLVs using different intraoral scanners or the indirect digitization technique are lacking. The purpose of this study was therefore to assess the marginal and internal fit of CAD/CAM-milled CLVs using different intraoral scanners and the indirect digitalization technique. An ivorine typodont maxillary left-central incisor was prepared; the tooth and the neighboring teeth were scanned and used as a template to print ninety 3D partial models. Thereafter, ceramic laminate veneers (CLVs) (N = 90) were milled from IPS-Emax CAD blocks and divided into six equal groups (15 specimens each) according to the type of intraoral scanner (IOS), as follows: Omnicam IOS, SC3600 IOS, Trios 3 IOS, Emerald IOS, I500 IOS. Fifteen further CLVs were fabricated using the conventional indirect digitalization technique. After cementation on the resin dies and embedding in clear epoxy resin, specimens were sectioned inciso-gingivally and mesio-distally. At the incisal and cervical positions, the marginal discrepancy was measured and evaluated in addition to the internal gap at six locations using SEM (200×). Differences between gap measurements among the six groups were determined using ANOVA. Games-Howell multiple comparisons for homogenous variances and LSD multiple comparisons for non-homogenous variances were used with 95% confidence intervals. The significance level was set at 0.05. The lowest mean absolute marginal gap at the incisal margins (AMGI) was recorded for Omnicam group (203.28 ± 80.14) µm, while the highest mean absolute marginal gap at the cervical margins (AMGC) was recorded for Omnicam group (147.16 ± 59.78) µm. The mean AMGC was reported to be significantly different between the conventional technique (146.75 ± 38.43) µm and Trios 3 (91.86 ± (35.51) µm; p = 0.001) and between Emerald (112.37 ± (50.31) µm; p = 0.042) and I500 (86.95 ± (41.55) µm; p < 0.001). The mean MGI was found to be significantly different between the conventional technique (114.11 ± (43.45) µm and I500 group (186.99 ± (73.84) µm) only (p = 0.035). However, no significant differences were found in the mean MGI between all types of IOSs. The means of AMG and MG were significantly different at incisal or cervical areas between the conventional technique and IOSs and within the scanner groups (p > 0.05). Marginal gaps were higher in the incisal region compared to the cervical region with both the indirect digitization technique and the IOSs. Ceramic laminate veneers (CLVs) fabricated using IOSs produced overall internal and marginal fit adaptation results comparable to CLVs fabricated from the indirect digitalization method, and both techniques produced clinically acceptable results.

12.
Adv Radiat Oncol ; 8(2): 101127, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36845612

RESUMEN

Purpose: This in vitro study aimed to investigate the changes in mechanical properties in dentin of third molars after radiation therapy using variable doses and frequencies. Methods and Materials: Rectangular cross sectioned dentin hemisections (N = 60, n = 15 per group; >7 × 4 × 1.2 mm) were prepared using extracted third molars. After cleansing and storage in artificial saliva, random distribution was performed to 2 irradiation settings, namely AB or CD (A, 30 single doses of irradiation [2 Gy each] for 6 weeks; B, control group of A; C, 3 single doses of irradiation [9 Gy each]; and D, control group of C). Various parameters (fracture strength/maximal force, flexural strength, and elasticity modulus) were assessed using a universal Testing Machine (ZwickRoell). The effect of irradiation on dentin morphology was evaluated by histology, scanning electron microscopy, and immunohistochemistry. Statistical analysis was performed using 2-way analysis of variance and paired and unpaired t tests at a significance level of 5%. Results: Significance could be found considering the maximal force applied to failure when the irradiated groups were compared with their control groups (A/B, P < .0001; C/D, P = .008). Flexural strength was significantly higher in the irradiated group A compared with control group B (P < .001) and for the irradiated groups A and C (P = .022) compared with each other. Cumulative radiation with low irradiation doses (30 single doses; 2 Gy) and single irradiation with high doses (3 single doses; 9 Gy) make the tooth substance more prone to fracture, lowering the maximal force. The flexural strength decreases when cumulative irradiation is applied, but not after single irradiation. The elasticity modulus showed no alteration after irradiation treatment. Conclusions: Irradiation therapy affects the prospective adhesion of dentin and the bond strength of future restorations, potentially leading to an increased risk of tooth fracture and retention loss in dental reconstructions.

13.
J Dent ; 131: 104438, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36717051

RESUMEN

OBJECTIVES: The aim of this study was to compare the shear bond strength of relined CAD-CAM complete removable dental prosthesis (CRDP) resins with conventional heat-polymerized polymethylmethacrylate (PMMA) resin. METHODS: A total of 96 resin specimens in identical dimensions of 10 mm × 10 mm × 11 mm were fabricated for four study groups [#1- Conventional heat-polymerized group: n=24 (ProBase); #2- Milled#1: n=24 (Ivobase); #3- Milled#2: n=24 (Ivotion); #4- 3D-printed: n=24, (NextDent Denture 3D+)]. Twelve specimens in each group were sectioned in the middle to produce a 3 mm defect and then were relined using a conventional denture relining material. All specimens underwent thermocycling (5-55°C) for 10,000 cycles. The shear bond tests were carried out in a universal testing machine. One-way ANOVA and Tukey's test were used for statistical analysis (p<0.05). The two-parameter Weibull distribution values were calculated. RESULTS: Relined 3D-printed specimens had a significantly lower shear bond strength when compared with conventional (p=0.0003) and milled groups (Milled#1: p=0.0004; Milled#2: p<0.0001). There were no differences in the shear bond strengths between the milled and conventional groups. Weibull distribution presented the highest shape value for the non-relined Milled#1 (22.83) group and the lowest values for the 3D-printed relined group (4.001). CONCLUSION: The findings of this study conclude that the shear bond strength of the conventionally-relined 3D-printed resins used for fabricating CRDPs was inferior to the shear bond strength of conventionally-relined resins employed for manufacturing CRDPs using CAD-CAM milling and conventional heat-polymerization techniques. CLINICAL SIGNIFICANCE: When considering 3D-printing for the fabrication of CRDPs, it is recommended to employ it in clinical situations where a frequent need for denture relining is not expected.


Asunto(s)
Diseño Asistido por Computadora , Impresión Tridimensional , Calor , Dentadura Completa , Ensayo de Materiales
14.
Clin Implant Dent Relat Res ; 25(1): 35-45, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36454235

RESUMEN

PURPOSE: To evaluate image quality and diagnostic accuracy of buccal bone thickness assessment in maxillary and mandibular anterior region using cone-beam computed tomography (CBCT) and 3-dimensional double-echo steady-state (DESS) MRI for preoperative planning of immediate dental implants in healthy individuals. METHODS: One hundred and twenty teeth in 10 volunteers were retrospectively evaluated for image quality and artifacts using Likert scale (4 = excellent to 0 = decreased). Buccal bone thickness was measured at three measurement points (M1 = 2 mm from the cementoenamel junction, M2 = middle of the root, and M3 = at the root apex) for each tooth in the maxillary (13-23) and the mandibular anterior region (33-43). Descriptive statistics and two-way ANOVA with Tukey's Post-hoc test were performed to evaluate the significant differences (α = 0.05) between both imaging modalities. RESULTS: Image quality showed little to no artifacts and enabled confident diagnostic interpretation (CBCT (3.72 ± 0.46); MRI (3.65 ± 0.49)), with no significant differences between both imaging modalities (p > 0.05). Regarding the assessment of buccal bone thickness at M1-M3 for the teeth 13-23 and 33-43, no significant differences were noted (p > 0.05). MRI demonstrated slight, nonsignificant overestimation of thickness with the canines having mainly a thick buccal bone wall, where thin buccal wall was evident for the central incisors. CONCLUSION: Black bone MRI sequences, such as 3D-DESS MRI, for immediate implant planning provided confidential diagnostic accuracy in bone thickness assessment without significant disadvantages compared to CBCT. Thus, the implementation of no-dose protocols for dental rehabilitation using an immediate loading approach seems promising and could further improve the treatment strategy for dental rehabilitation.


Asunto(s)
Implantes Dentales , Proyectos Piloto , Proceso Alveolar , Estudios Retrospectivos , Incisivo , Maxilar , Tomografía Computarizada de Haz Cónico
15.
J Mech Behav Biomed Mater ; 137: 105547, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36370641

RESUMEN

PURPOSE: The purpose of this in-vitro study was to investigate the effect of framework design on fracture resistance and failure modes of cantilever inlay-retained fixed partial dentures (IRFDPs) fabricated from two multilayered monolithic zirconia materials. MATERIALS AND METHODS: Seventy-two natural premolar teeth were prepared as abutments for cantilever IRFDPs using three designs: mesial-occlusal (MO) inlay with short buccal and palatal wings (D1), MO inlay with long palatal wing (D2), MO inlay with long palatal wing and occlusal extension (D3). Full-contoured IRFDPs were fabricated from two monolithic zirconia materials; IPS e.max ZirCAD Prime and Zolid Gen-X. Adhesive surfaces were air-abraded and bonded with MDP-containing resin cement. Specimens were subjected to thermocycling (5-55 °C, 5000 cycles); then, mechanical loading (1.2 × 106 cycles, 49 N). Surviving specimens were loaded until failure in the universal testing machine. All specimens were examined under stereomicroscope, and two samples from each group were evaluated using Scanning Electron Microscope. RESULTS: Mean failure loads were not significantly different between different framework designs or between two materials. However, IPS e.max ZirCAD Prime showed significantly higher failure rate than Zolid Gen-X during dynamic fatigue (p = 0.009). Samples with D1 design showed higher debonding rate, D2 failed mainly by fracture of the palatal wing and debonding, and D3 failed mainly by fracture of the abutment tooth. Debonded restorations showed mainly mixed failures. CONCLUSION: Cantilever IRFDPs with framework designs that maximize adhesion to enamel exhibited promising results. IPS e.max ZirCAD Prime was more susceptible to fractures with the long palatal wing design.


Asunto(s)
Diseño de Dentadura , Circonio , Cerámica , Dentadura Parcial Fija , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Porcelana Dental , Ensayo de Materiales
16.
J Prosthet Dent ; 130(1): 111-118, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34799084

RESUMEN

STATEMENT OF PROBLEM: The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently. PURPOSE: The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas. MATERIAL AND METHODS: Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (α=.05). RESULTS: In the partially edentulous model, distance trueness mean ±standard deviation values ranged from -46.7 ±15.4 µm (TRIOS 3) to 392.1 ±314.3 µm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean ±standard deviation values ranged between -35 ±13 µm (TRIOS 4) and 117.7 ±232.3 µm (CARESTREAM). Trueness mean ±standard deviation values of angulation varied from -0.0 ±0.5 degrees (CARESTREAM) to 0.2 ±0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 ±0.2 degrees (TRIOS 3) to 0.4 ±0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 ±47.1 µm (TRIOS 4) to 107.2 ±103.5 µm (Medit) without additional artificial landmarks and from -15.0 ±45.0 µm (CARESTREAM) to -86.9 ±42.1 µm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered. CONCLUSIONS: Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision.


Asunto(s)
Arcada Edéntula , Boca Edéntula , Humanos , Técnica de Impresión Dental , Modelos Dentales , Imagenología Tridimensional , Arcada Edéntula/diagnóstico por imagen , Diseño Asistido por Computadora , Boca Edéntula/diagnóstico por imagen
17.
J Prosthodont ; 32(S1): 68-73, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35924435

RESUMEN

PURPOSE: To measure the flexural strength and Weibull characteristics of aged and nonaged printed interim dental material fabricated with different layer thickness. MATERIAL AND METHODS: Bars (25×2×2 mm) were additively fabricated by using a polymer printer (Asiga Max) and an interim resin (Nexdent C&B MFH). Specimens were fabricated with the same printing parameters and postprocessing procedures, but with 7 different layer thickness: 50 (control or 50-G group), 10 (10-G group), 25 (25-G group), 75 (75-G group), 100 (100-G group), 125 (125-G group), and 150 µm (150-G group). Two subgroups were created: nonaged and aged subgroups (n = 10). A universal testing machine was selected to measure flexural strength. Two-parameter Weibull distribution values were computed. Two-way ANOVA and Tukey tests were selected for statistical evaluation of the data (α = 0.05). RESULTS: Artificial aging methods (p < 0.001) were a significant predictor of the flexural strength computed. Aged specimens acquired less flexural strength than nonaged specimens. The Weibull distribution obtained the highest shape for nonaged 50-G and 75-G group specimens compared with those of other nonaged groups, while the Weibull distribution showed the highest shape for aged 125-G specimens. CONCLUSIONS: The flexural strength of the additively fabricated interim material examined was not influenced by the layer thickness at which the specimens were fabricated; however, artificial aging techniques reduced its flexural strength. Aged specimens presented lower Weibull distribution values compared with nonaged specimens, except for the 125-G specimens.


Asunto(s)
Materiales Dentales , Resistencia Flexional , Ensayo de Materiales , Ensayo de Materiales/métodos , Propiedades de Superficie , Estrés Mecánico , Impresión Tridimensional , Polimerizacion , Polímeros
18.
J Mech Behav Biomed Mater ; 136: 105520, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36341889

RESUMEN

PURPOSE: The aim was to investigate the load bearing capacity of different pressable lithium disilicates cemented as occlusal veneers on molars. MATERIALS AND METHODS: One control group and six test groups were formed consisting of 20 specimens each (n = 20). The six test groups differed in the utilizing pressable lithium disilicate to fabricate occlusal veneers. As a control group, "group Lis", the lithium disilicate with the highest reported flexural strength was used (initial LiSi Press, GC Europe; Leuven, Belgium / flexural strength: 508 MPa). The test groups consisted of other pressable lithium disilicates with lower flexural strength values: "Ema" (IPS e.max press), "Vit" (VITA Ambria), "Liv" (Livento Press), "Amb" (Amber Press), "Mas" (Amber Press Master) and "Ros" (Rosetta SP)". After the preparation of 140 extracted human molars, which included the removal of the central enamel, the specimens were scanned using a desktop scanner. With the aid of a design software, the occlusal veneers were designed in a standardized thickness of 0.5 mm. To fabricate the restorations, all tested materials were processed using heat-pressing technique. All restorations were adhesively cemented. Afterwards, the specimens underwent cyclic fatigue during an aging procedure in a chewing simulator (1'200'000 chewing-cycles, 49 N force, 5-55°C temperature changes). Subsequently, the specimens were statically loaded and the load which was necessary to fracture the specimen (Fmax) were measured. Differences between the groups were compared applying the Kruskal-Wallis (KW) test and the Wilcoxon-Mann-Whitney-Test (WMW: p < 0.05). The two-parameter Weibull distribution values were calculated. RESULTS: The fatigue resistance was 100% for the groups Lis, Vit, Liv, Amb, Mas and Ros, whereas the group Ema showed a fatigue resistance of 95%. The control group Lis showed median Fmax values of 2'328 N. The median Fmax values for the test groups ranged between 1'753 N (Vit) and 2'490 N (Ros). Statistically significant difference was observed among the groups Lis (control) and Vit (KW: p < 0.001). Weibull distribution presented the highest shape values for the group Ros (12.83) and the lowest values for the group Ema (4.71). CONCLUSION: Regarding their load-bearing capacity different pressable lithium disilicates can be recommended to fabricate ultra-thin occlusal veneers on molars when restoring occlusal tooth wear.


Asunto(s)
Cerámica , Litio , Humanos , Soporte de Peso , Ensayo de Materiales , Ámbar , Porcelana Dental , Análisis del Estrés Dental , Diseño Asistido por Computadora
19.
Materials (Basel) ; 15(21)2022 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-36363236

RESUMEN

The effects of different heights of ti-base abutments on the color of anterior screw-retained zirconia restorations fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technologies may affect the optical clinical outcome. The purpose of this study was to measure and compare the color parameters of zirconia crowns in different shades on ti-base abutments. Identical specimens (N = 160) were milled to restore the screw-retained central maxillary incisor crown, using 5% mol yttria zirconia (5Y-TZP). The specimens were designed using computer design software to match 3.5 mm and 5.5-mm ti-base abutments and milled using one CAD-CAM technology. Specimens were divided into four main groups depending on zirconia shade (A1/0, A2/3, A3.5/4 and B2/3) and then assigned to two subgroups according to ti-base height. Color measurements in the CIELab coordinates were made using a spectrophotometer under room-light conditions. Color difference (ΔE*) values were calculated using the CIE76 and CIEDE2000 formula. Within the group of A0/1 and A2/3, for 5.5 mm abutment height, a significant difference was found between the means of colors ∆E00 and ∆Eab (p < 0.01). Using a 5.5 mm-height ti-base abutment may produce a clinically unacceptable outcome (ΔEab > 2) in A1/0 and A2/3 color groups.

20.
J Funct Biomater ; 13(4)2022 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-36278658

RESUMEN

The effect of a surface pre-reacted glass ionomer (S-PRG)-containing sealant on the demineralization inhibition and remineralization of intact enamel adjacent to the sealant material was investigated. BeautiSealant (BTS, S-PRG sealant, Shofu), Teeth Mate F-12.0 (TMF, fluoride-releasing sealant, Kuraray Noritake Dental), and an experimental silica-filler sealant were investigated. After pH cycling for 10 days, the enamel surface adjacent to the sealant material was observed using confocal laser microscopy and scanning electron microscopy. The polymerized sealant disks were immersed in a demineralized solution (pH: 4.3) to measure pH change. The enamel specimens with polymerized sealant disks were additionally immersed in demineralized solution, followed by energy-dispersive X-ray spectroscopy. The demineralized area of BTS was significantly smaller than that of TMF and SS (p < 0.05). The surfaces adjacent to the sealant of TMF and SS were demineralized, while the surface of BTS was comparatively intact. An increase in pH values were observed in the BTS and TMF groups. Enamel surfaces presented an inhibition of demineralization for BTS and TMF, but not for SS. Fluoride uptake from the polymerized sealant was greater for BTS than for TMF. The S-PRG-containing sealant showed a buffering ability, demineralization inhibition, promotion of remineralization, and it can be advised for clinical applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...