1.
J Interv Card Electrophysiol ; 40(1): 23-31, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24633546

RESUMEN

PURPOSE: Contact with cardiac tissue is a determinant of lesion efficacy during atrial fibrillation (AF) ablation. The Sensei®X Robotic Catheter System (Hansen Medical, CA) has been validated for contact force sensing. The electrical coupling index (ECI) from the EnSite Contact™ system (St. Jude Medical, MN) has been validated as an indicator of tissue contact. We aimed at analyzing ECI behavior during radiofrequency (RF) pulses maintaining a stable contact through the robotic navigation contact system. METHODS: In 15 patients (age, 59 ± 12) undergoing AF ablation, pulmonary vein (PV) isolation was guided by the Sensei®X System, employing the Contact™ catheter. RESULTS: During the procedure, we assessed ECI changes associated with adequate contact based on the IntelliSense® force-sensing technology (Hansen Medical, CA. Baseline contact (27 ± 8 g/cm(2)) ECI value was 99 ± 13, whereas ECI values in a noncontact site (0 g/cm(2)) and in a light contact site (1-10 g/cm(2)) were respectively 66 ± 12 and 77 ± 10 (p < 0.0001). Baseline contact ECI values were not different depending on AF presentation (paroxysmal AF, 98 ± 9; persistent AF, 100 ± 9) or on cardiac rhythm (sinus rhythm, 97 ± 7; AF,101 ± 10). In all PVs, ECI was significantly reduced during and after ablation (ECI during RF, 56 ± 15; ECI after RF, 72 ± 16; p < 0.001). A mean reduction of 32.2% during RF delivery and 25.4% immediately after RF discontinuation compared with baseline ECI was observed. CONCLUSIONS: Successful PV isolation is associated with a significant decrease in ECI of at least 20 %. This may be used as a surrogate marker of effective lesion in AF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Cirugía Asistida por Computador , Anciano , Ablación por Catéter/instrumentación , Impedancia Eléctrica , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pletismografía de Impedancia/métodos , Presión , Robótica
2.
Eur Heart J Cardiovasc Imaging ; 14(3): 285-93, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22968525

RESUMEN

AIMS: Since there is insufficient data available about the inter-vendor consistency of three-dimensional (3D) speckle-tracking (STE) measurements, we undertook this study to (i) assess the inter-vendor consistency of 3D LV global strain values obtained using two different scanners; (ii) identify the sources of inter-vendor inconsistencies, if any; and (iii) compare their respective intrinsic variability. METHODS AND RESULTS: Sixty patients (38 ± 12 years, 64% males) with a wide range of LV end-diastolic volumes (from 74 to 205 ml) and ejection fractions (from 17 to 70%) underwent two 3D LV data set acquisitions using VividE9 and Artida ultrasound systems. Global longitudinal (Lε), radial (Rε), circumferential (Cε) and area (Aε) strain values were obtained offline using the corresponding 3D STE softwares. Despite being significantly different, Lε showed the closest values between the two platforms (bias = 1.5%, limits of agreement (LOA) from -2.9 to -5.9%, P < 0.05). Artida produced significantly higher values of both Cε and Aε than VividE9 (bias = 6.6, LOA: -14.1 to 0.9%, and bias = 6.0, LOA = -28.2-8.6%, respectively, P < 0.001). Conversely, Rε values obtained with Artida were significantly lower than those measured using VividE9 platform (bias = -24.2, LOA: 1.5-49.9, P < 0.001). All strain components showed good reproducibility (intra-class correlation coefficients: 0.82-0.98), except for Rε by Artida, which showed only a moderate reproducibility. CONCLUSION: Apart from Lε, the inter-vendor agreement of Rε, Cε and Aε measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.


Asunto(s)
Ecocardiografía Tridimensional/instrumentación , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Volumen Sistólico