Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Aerosol Med Pulm Drug Deliv ; 28(3): 202-10, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25229261

RESUMEN

BACKGROUND: Indacaterol is a novel once-a-day inhaled ultra-long-acting ß2-agonist. Quantitative bioanalysis supports pharmacokinetic and clinical research. The aim of the current work was to validate an in-house developed high performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) analytical method for indacaterol determination in human urine samples. METHODS: A liquid-liquid extraction method has been developed to extract indacaterol from human urine samples using ethyl acetate. Indacaterol dry extract was reconstituted with 200 µL of the mobile phase (acidified water:methanol (30:70, v/v)) of which 5 µL was needed for the HPLC-MS/MS analysis. Indacaterol was eluted on a reversed C18 stationary phase with an isocratic mobile phase at a flow of 1 mL/min. Formoterol was the internal standard (IS). The MS/MS detection was employed with a turbo-ion spray ionization in the positive ion mode. A consensus of the international Guidelines for Bioanalytical Method Validation was followed. RESULTS: Indacaterol was detected at a mass to charge ratio (m/z) of 393.3 and its MS/MS daughter at 173.2. The retention times of indacaterol and IS were 1.60 and 1.20 min, respectively. Validated calibration curves were linear over a range of 0.075-100 ng/mL with correlation coefficients (r)≥0.990. The curves' regression weighting factor was 1/x. Method specificity was established in six different human urine batches. No matrix interference was observed. The intra- and inter-batch precision and accuracy within±20% (at lower limit) and±15% (other quality control (QC) levels) were confirmed. The indacaterol mean recovery (precision) percentages at Low, Mid, and High QC levels were 93.5 (3.84), 89.8 (2.15), and 92.2 (2.17), respectively. Short-term, long-term, freeze-thaw, and auto-sampler stability results were accepted. CONCLUSIONS: A specific, accurate and precise HPLC-MS/MS method has been validated for indacaterol quantification in human urine. This simple method is reproducible and robust to support future, indacaterol-related pharmacokinetic, bioequivalence and clinical studies.


Asunto(s)
Agonistas de Receptores Adrenérgicos beta 2/orina , Cromatografía Líquida de Alta Presión , Monitoreo de Drogas/métodos , Indanos/orina , Extracción Líquido-Líquido , Quinolonas/orina , Espectrometría de Masas en Tándem , Calibración , Cromatografía Líquida de Alta Presión/normas , Monitoreo de Drogas/normas , Estabilidad de Medicamentos , Humanos , Límite de Detección , Modelos Lineales , Extracción Líquido-Líquido/normas , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA