1.
Appl Radiat Isot ; 189: 110409, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36037726

RESUMEN

The dosimetric characteristics of newly developed gadolinium (Gd) glass dosimeter produced via sol-gel method are reported. Irradiation were made using a 750 kW neutron flux thermal power and 1.25 MeV 60Co gamma rays with entrance doses from 2 to 10 Gy. Investigation has been done on various Gd dopant concentrations, ranging from 1 to 10 mol%. The Gd-doped silica glass have been characterised for thermoluminescence (TL) dose response, sensitivity, linearity index, glow curve and kinetic parameter analysis. For particular dopant concentration obtained in 6 mol% Gd, the least squares fit shows the change in TL yield, correlation coefficient (r2) of better than 0.980 (at 95% confidence level), with neutron and gamma exposure to be 8 and 4 times greater than that of 1 mol% Gd, respectively. Broad peaks in the absence of any sharp peak observed in the glow curve confirms the amorphous nature of the prepared glass. A glow curve of Gd-doped SiO2 sample is observed with a single prominent peak (Tm) within 200-250 °C (peak shifting appears with respect to the increment of dopant concentration) and 350 °C (for all respective Gd dopants) for neutron and gamma irradiations, respectively. Deconvolution shows the glow curves of the Gd-doped SiO2 glass to be formed of seven and five overlapping peaks, with figures of merit below 2% (FOM) of between 1.38-1.79 and 1.30-1.97 for the particular neutron and gamma irradiations, respectively. Through use of Glowfit deconvolution software, the key trapping parameters of activation energy, E and frequency factor, s-1 were calculated for the Gd-doped SiO2 glass. The mechanism of TL yield with the gradual increase in Gd concentrations and doses is explained upon the incorporation of Gd and radiation damage that change the structure of the electron traps in the glass matrix. These early results indicate that selectively screened Gd-SiO2 glass can be developed into a promising TL system towards dosimetric applications.

2.
PLoS One ; 16(9): e0258264, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34591934

RESUMEN

[This corrects the article DOI: 10.1371/journal.pone.0235053.].

3.
Appl Radiat Isot ; 176: 109814, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34175543

RESUMEN

Brachytherapy is commonly used in treatment of cervical, prostate, breast and skin cancers, also for oral cancers, typically via the application of sealed radioactive sources that are inserted within or alongside the area to be treated. A particular aim of the various brachytherapy techniques is to accurately transfer to the targeted tumour the largest possible dose, at the same time minimizing dose to the surrounding normal tissue, including organs at risk. The dose fall-off with distance from the sources is steep, the dose gradient representing a prime factor in determining the dose distribution, also representing a challenge to the conduct of measurements around sources. Amorphous borosilicate glass (B2O3) in the form of microscope cover slips is recognized to offer a practicable system for such thermoluminescence dosimetry (TLD), providing for high-spatial resolution (down to < 1 mm), wide dynamic dose range, good reproducibility and reusability, minimal fading, resistance to water and low cost. Herein, investigation is made of the proposed dosimeter using a 1.25 MeV High Dose Rate (HDR) 60Co brachytherapy source, characterizing dose response, sensitivity, linearity index and fading. Analysis of the TL glow curves were obtained using the Tmax-Tstop method and first-order kinetics using GlowFit software, detailing the frequency factors and activation energy.


Asunto(s)
Compuestos de Boro/química , Braquiterapia/métodos , Radioisótopos de Cobalto/administración & dosificación , Vidrio , Dosificación Radioterapéutica , Silicatos/química , Dosimetría Termoluminiscente/métodos , Agua
4.
PLoS One ; 15(12): e0241550, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33378398

RESUMEN

For x- and gamma- irradiations delivering entrance doses from 2- up to 1000 Gy to commercial 1.0 mm thick borosilicate glass microscope slides, study has been made of their thermoluminescence yield. With an effective atomic number of 10.6 (approximating bone equivalence), photon energy dependency is apparent in the low x-ray energy range, with interplay between the photoelectric effect and attenuation. As an example, over the examined dose range, at 120 kVp the photon sensitivity has been found to be some 5× that of 60Co gamma irradiations, also with repeatability to within ~1%. The glow-curves, taking the form of a single prominent broad peak, have been deconvolved yielding at best fit a total of five peaks, the associated activation energies and frequency factors also being obtained. The results indicate borosilicate glass slides to offer promising performance as a low-cost passive radiation dosimeter, with utility for both radiotherapy and industrial applications.


Asunto(s)
Compuestos de Boro/química , Fotones , Dosímetros de Radiación , Silicatos/efectos de la radiación , Dosimetría Termoluminiscente/instrumentación , Compuestos de Boro/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Rayos gamma , Humanos , Dosis de Radiación , Silicatos/química , Dosimetría Termoluminiscente/métodos , Rayos X
5.
PLoS One ; 15(7): e0235053, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32673337

RESUMEN

Study has been made of the thermoluminescence yield of various novel tailor-made silica fibres, 6 and 8 mol % Ge-doped, with four differing outer dimensions, comprised of flat and cylindrical shapes, subjected to electron irradiation. Main thermoluminescence dosimetric characteristics have been investigated, including the glow curve, dose response, energy dependence, minimum detectable dose, effective atomic number, linearity of index and sensitivity of the fibres. The studies have also established the uncertainties involved as well as the stability of response in terms of fading effect, reproducibility and annealing. In addition, dose-rate dependence was accounted for as this has the potential to be a significant factor in radiotherapy applications. The 6 and 8 mol % fibres have been found to provide highly linear dose response within the range 1 to 4 Gy, the smallest size flat fibre, 6 mol% Ge-doped, showing the greatest response by a factor of 1.1 with respect to the highly popular LiF phosphor-based medium TLD100. All of the fibres also showed excellent reproducibility with a standard deviation of < 2% and < 4% for 6 and 8 mol % Ge-doped fibres respectively. For fading evaluation, the smallest 6 mol% Ge-doped dimension flat fibre, i.e., 85 × 270 µm displayed the lowest signal loss within 120 days post-irradiation, at around 26.9% also showing a response superior to that of all of the other fibres. Moreover, all the fibres and TLD-100 chips showed independence with respect to electron irradiation energy and dose-rate. Compared with the 8 mol% Ge-doped optical fibres, the 6 mol% Ge-doped flat optical fibres have been demonstrated to possess more desirable performance features for passive dosimetry, serving as a suitable alternative to TLD-100 for medical irradiation treatment applications.


Asunto(s)
Germanio , Fibras Ópticas/normas , Dosificación Radioterapéutica , Electrones , Reproducibilidad de los Resultados , Dióxido de Silicio , Dosimetría Termoluminiscente/métodos
6.
Radiat Environ Biophys ; 59(3): 523-537, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32462382

RESUMEN

Accidents resulting in widespread dispersal of radioactive materials have given rise to a need for materials that are convenient in allowing individual dose assessment. The present study examines natural Dead Sea salt adopted as a model thermoluminescence dosimetry system. Samples were prepared in two different forms, loose-raw and loose-ground, subsequently exposed to 60Co gamma-rays, delivering doses in the range 2-10 Gy. Key thermoluminescence (TL) properties were examined, including glow curves, dose response, sensitivity, reproducibility and fading. Glow curves shapes were found to be independent of given dose, prominent TL peaks for the raw and ground samples appearing in the temperature ranges 361-385 ºC and 366-401 ºC, respectively. The deconvolution of glow curves has been undertaken using GlowFit, resulting in ten overlapping first-order kinetic glow peaks. For both sample forms, the integrated TL yield displays linearity of response with dose, the loose-raw salt showing some 2.5 × the sensitivity of the ground salt. The samples showed similar degrees of fading, with respective residual signals 28 days post-irradiation of 66% and 62% for the ground and raw forms respectively; conversely, confronted by light-induced fading the respective signal losses were 62% and 80%. The effective atomic number of the Dead Sea salt of 16.3 is comparable to that of TLD-200 (Zeff 16.3), suitable as an environmental radiation monitor in accident situations but requiring careful calibration in the reconstruction of soft tissue dose (soft tissue Zeff 7.2). Sample luminescence studies were carried out via Raman and Photoluminescence spectroscopy as well as X-ray diffraction, ionizing radiation dependent variation in lattice structure being found to influence TL response.