1.
Pract Lab Med ; 32: e00300, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36035320

RESUMEN

Objectives: Verifying new reagent or calibrator lots is crucial for maintaining consistent test performance. The Institute for Quality Management in Healthcare (IQMH) conducted a patterns-of-practice survey and follow-up case study to collect information on lot verification practices in Ontario. Methods: The survey had 17 multiple-choice questions and was distributed to 183 licensed laboratories. Participants provided information on materials used and approval/rejection criteria for their lot verification procedures for eight classes of testing systems. The case study provided a set of lot comparison data and was distributed to 132 laboratories. Responses were reviewed by IQMH scientific committees. Results: Of the 175 laboratories that responded regarding reagent lot verifications, 74% verified all tests, 11% some, and 15% none. Of the 171 laboratories that responded regarding calibrator lot verifications, 39% verified all calibrators, 4% some, and 57% none. Reasons for not performing verifications ranged from difficulty performing parallel testing to high reagent cost. For automated chemistry assays and immunoassays, 23% of laboratories did not include patient-derived materials in reagent lot verifications and 42% included five to six patient materials; 58% of laboratories did not include patient-derived materials in calibrator lot verifications and 23% included five to six patient materials. Different combinations of test-specific rules were used for acceptance criteria. For a failed lot, 98% of laboratories would investigate further and take corrective actions. Forty-three percent of laboratories would accept the new reagent lot in the case study. Conclusion: Responses to the survey and case study demonstrated variability in lot verification practices among laboratories.

2.
Clin Biochem ; 46(13-14): 1187-93, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23648455

RESUMEN

OBJECTIVES: The aim of this study is to describe how implementation of a quality management system (QMS) based on ISO 15189 enhances patient safety. DESIGN AND METHODS: A literature review showed that several European hospitals implemented a QMS based on ISO 9001 and assessed the impact on patient safety. An Internet search showed that problems affecting patient safety have occurred in a number of laboratories across Canada. The requirements of a QMS based on ISO 15189 are outlined, and the impact of the implementation of each requirement on patient safety is summarized. The Quality Management Program - Laboratory Services in Ontario is briefly described, and the experience of Ontario laboratories with Ontario Laboratory Accreditation, based on ISO 15189, is outlined. RESULTS: Several hospitals that implemented ISO 9001 reported either a positive impact or no impact on patient safety. Patient safety problems in Canadian laboratories are described. Implementation of each requirement of the QMS can be seen to have a positive effect on patient safety. Average laboratory conformance on Ontario Laboratory Accreditation is very high, and laboratories must address and resolve any nonconformities. Other standards, practices, and quality requirements may also contribute to patient safety. CONCLUSION: Implementation of a QMS based on ISO 15189 provides a solid foundation for quality in the laboratory and enhances patient safety. It helps to prevent patient safety issues; when such issues do occur, effective processes are in place for investigation and resolution. Patient safety problems in Canadian laboratories might have been prevented had effective QMSs been in place. Ontario Laboratory Accreditation has had a positive impact on quality in Ontario laboratories.


Asunto(s)
Seguridad del Paciente/normas , Control de Calidad , Calidad de la Atención de Salud/normas , Canadá , Humanos , Laboratorios/legislación & jurisprudencia , Laboratorios/normas , Ontario , Seguridad del Paciente/legislación & jurisprudencia , Garantía de la Calidad de Atención de Salud/legislación & jurisprudencia , Garantía de la Calidad de Atención de Salud/normas , Calidad de la Atención de Salud/legislación & jurisprudencia
4.
BJOG ; 112(5): 559-66, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15842277

RESUMEN

OBJECTIVE: This trial compared two instruments for transcervical chorionic villus sampling (CVS). DESIGN: Randomised controlled trial. SETTING: Regional university prenatal diagnosis and treatment centre. POPULATION: Two hundred women were randomised at 10(+0)-12(+6) weeks of gestation to transcervical CVS using cannula aspiration (CA) or biopsy forceps (BF). METHODS: Women undergoing indicated CVS signed informed consent. Randomisation after decision to perform transcervical CVS. PRIMARY OUTCOME: the rise in maternal serum alpha-fetoprotein (alpha-FP). SECONDARY OUTCOMES: (i) placental trauma (fetomaternal haemorrhage [FMH]); (ii) laboratory, procedure, and cytogenetic results and pregnancy outcomes; (iii) patient and operator satisfaction; and (iv) economic analyses. Analyses were performed by intention to treat. RESULTS: The -FP rise did not differ between groups; there was no other evidence of placental trauma. BF were better tolerated by women, provided culturable tissue, after fewer instrument passes, with greater ease and in less time. BF were associated with cost savings. CONCLUSIONS: Unlike -FP, other markers of FMH were unaltered, questioning the reliability of alpha-FP as an indicator of FMH. Compared with CA, transcervical BF caused comparable placental trauma, appeared to be similarly effective and safe and were preferred by operators and patients.


Asunto(s)
Biopsia con Aguja/instrumentación , Cateterismo/normas , Muestra de la Vellosidad Coriónica/instrumentación , Instrumentos Quirúrgicos/normas , Biopsia con Aguja/métodos , Biopsia con Aguja/normas , Muestra de la Vellosidad Coriónica/métodos , Muestra de la Vellosidad Coriónica/normas , Análisis Citogenético , Diseño de Equipo , Femenino , Transfusión Fetomaterna/etiología , Humanos , Forceps Obstétrico , Satisfacción del Paciente , Embarazo , Resultado del Embarazo , alfa-Fetoproteínas/metabolismo
5.
Clin Chem Lab Med ; 41(10): 1379-86, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14580170

RESUMEN

This document summarizes the steps in development of a new IFCC Master Program and outlines some of the ways the IFCC would assist in setting up such a regional Program. This is intended to be of assistance to those who wish to embark on such an endeavour.


Asunto(s)
Educación de Postgrado/organización & administración , Laboratorios/organización & administración , Manuales como Asunto , Personal de Laboratorio Clínico/educación
6.
Clin Biochem ; 36(4): 317-20, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12810162

RESUMEN

OBJECTIVES: To evaluate the analytical performance of the Bio-Rad Variant II HbA(1c) dual kit assay. DESIGN AND METHODS: Precision, carryover, linearity and analytical range were investigated. 139 patients' HbA(1c) results analyzed by the Variant II were compared to the Variant I method. 49 blood samples analyzed by the Variant II at Toronto Medical Laboratories (TML) were compared to the Variant II at Hospital for Sick Children (HSC). RESULTS: Total imprecision was less than 2% for the Variant II assay. The method had a wide analytical range with no carryover. HbA(1c) results were not changed after switching back and forth from the beta thalassemia to HbA(1c) assay. The Variant II showed an average of 0.0027 negative bias compared to the Variant I method. There was an average of 0.0020 negative bias for HbA(1c) results on the Variant II at TML compared to the Variant II at HSC. CONCLUSIONS: HbA(1c) analysis on the Variant II HbA(1c) dual kit is a relatively fast and reproducible method.


Asunto(s)
Cromatografía Líquida de Alta Presión/normas , Diabetes Mellitus/sangre , Hemoglobina Glucada/análisis , Juego de Reactivos para Diagnóstico/normas , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Humanos , Reproducibilidad de los Resultados
7.
Clin Chem ; 49(1): 69-76, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12507962

RESUMEN

BACKGROUND: Mid-trimester maternal serum alpha-fetoprotein (AFP) and unconjugated estriol (uE3) are 30% lower and human chorionic gonadotropin (hCG) is twofold higher in Down syndrome pregnancies compared with unaffected pregnancies. In maternal serum screening, patient-specific risks are calculated using published gaussian frequency distribution parameters for these three markers obtained with previously available immunoassays. New immunoassays must generate similar distribution parameters if the accuracy of assigned risks and overall performance of prenatal screening are to be maintained. METHODS: Agreement between the Beckman Coulter Access and the Bayer Immuno 1 assays for AFP and hCG and the Amersham Amerlex-M RIA for uE3 was assessed in 558 fresh sera. Precision was measured over 6 weeks. Median concentrations were calculated by regression of 568 Caucasian singleton pregnancy samples against gestational age in days. Frozen mid-trimester sera from 44 confirmed Down syndrome singleton pregnancies (cases) were selected without conscious bias for reanalysis, and each case was matched with five control specimens from unaffected pregnancies. Serum markers were expressed as the multiple of the median (MoM) concentration derived from the control samples, corrected for maternal weight and converted to their log-equivalent values. Normality was assessed using probability plots and the Shapiro-Wilk W-test. Gaussian distribution parameters were compared with established values, and Down syndrome risk calculations were assessed with a commonly used risk algorithm. RESULTS: The Access AFP and hCG assays had consistent proportional agreement with the established assays, whereas agreement between the uE3 methods was less consistent. Analytical imprecision was 3-6% at mid-trimester concentrations. Normal distributions were obtained for the log MoM values of all three markers in both the Down syndrome and unaffected populations, and their gaussian distribution parameters compared well with established values. The performance of the Access assays in an established trivariate risk algorithm for Down syndrome was equal to the performance exhibited by traditional methods. CONCLUSION: The Beckman Coulter Access analyzer provides valid mid-trimester serum AFP, uE3, and hCG results and risk assessments when applied in a prenatal Down syndrome screening service.


Asunto(s)
Síndrome de Down/diagnóstico , Biomarcadores/sangre , Gonadotropina Coriónica/sangre , Síndrome de Down/sangre , Estriol/sangre , Femenino , Humanos , Inmunoensayo/métodos , Tamizaje Masivo/métodos , Embarazo , Segundo Trimestre del Embarazo , Curva ROC , Distribuciones Estadísticas , alfa-Fetoproteínas/análisis