Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Environ Public Health ; 2023: 3512328, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37283812

RESUMEN

This study was conducted at one of the largest poultry companies in Kuwait during November and December 2019 to evaluate the microbiological threats of Escherichia coli (APEC), Salmonella spp., and Aspergillus fumigatus to chickens in fattening houses by counting and identifying the microorganisms by culturing and pyrosequencing analysis. During the fattening cycle, the temperature and humidity ranged between 23.6°C and 29°C and 64.1% and 87.1%, respectively. The total bacterial population and Aspergillus fumigatus measured in the indoor and outdoor air exhibited a linear relationship during the fattening cycle. The total bacterial and Aspergillus concentrations determined during the cycle ranged between 150 and 2000 CFU/m3 and 0 and 1000 CFU/m3, respectively. E. coli and Salmonella spp. concentrations determined during the cycle ranged between 1 and 220 CFU/m3 and 4 and 110 CFU/m3, respectively. Pyrosequencing analysis of the air inside the houses at the end of the cycle revealed extensive biodiversity in the microorganisms, detecting 32 bacterial genera and 14 species. The identified species belonging to the genera Corynebacterium, Haemophilus, Streptococcus, Veillonella, and Aspergillus were identified as potentially affecting human and broiler health. The emission of potentially pathogenic bacteria to the outdoor environment from chicken housing can pose a considerable risk to human health and environmental microbial pollution. This study could guide the development of integrated control devices for monitoring microbes in broiler production facilities during chicken collection for transport to slaughterhouses.


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Humanos , Animales , Pollos , Escherichia coli , Contaminación del Aire Interior/análisis , Microbiología del Aire , Contaminación del Aire/análisis , Aspergillus , Bacterias , Monitoreo del Ambiente , Hongos
2.
Environ Monit Assess ; 194(5): 355, 2022 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-35403921

RESUMEN

Microbiological air contamination in the desert environment is becoming an essential subject for the health of office building occupants and public health. In this study, the concentrations and compositions of airborne microorganisms (bacteria and fungi) were assessed in indoor and outdoor environments using a multistory building complex in Kuwait as a case study. Airborne microorganism samples were collected from 12 sites within the building complex containing nineteen stories over four seasons. Culturable airborne bacteria and fungi were impacted on selected media to determine their concentrations and compositions with a Biolog Omnilog GEN III system and Biolog MicroStation. The indoor mean airborne bacterial count concentrations ranged from 35 to 18,463 CFU/m3, concentrations that are higher than 2,000 CFU/m3, demonstrating high-very high contamination levels in all seasons. Fungal contamination was high in winter and summer, with detected concentrations > 2,000 CFU/m3. Indoor-to-outdoor (I/O) ratios showed that airborne microbial contamination inside building floors originated from indoor air contamination. All the building floors showed bacterial and fungal concentrations ranging from less than 2,000 to more than 2,000 CFU/m3, indicative of a high to very high air contamination level. Statistical analysis showed no correlation between bacterial and fungal concentrations, demonstrating that they originated from unrelated sources. In the indoor building air, the most prevalent bacterial isolate was Bacillus pseudomycoides/cereus, whereas the most dominant fungal isolate was Aspergillus spp. The low count for indoor air bacterial species suggested no particular health risk for the occupants. In contrast, the high count of indoor air fungal species in the winter samples and the presence of potentially allergenic genera detected may suggest possible health risks for the occupants. The results obtained are the basis for the recommendation that the maintenance activities of the HVAC system and the periodical cleaning operation program be revised and preplanned as protective measures.


Asunto(s)
Microbiología del Aire , Contaminación del Aire Interior , Contaminación del Aire Interior/análisis , Bacterias , Clima Desértico , Monitoreo del Ambiente , Hongos , Estaciones del Año
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...