Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Oral Health ; 5: 1375186, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38817845

RESUMEN

Objectives: Digital denture fabrication became an alternative method to conventional denture fabrication. However reviewing the antimicrobial performance of newly introduced digital fabrication methods in comparison to the conventional method is neglected. Aim of study: this review was to compare the antiadherence properties of various CAD-CAM subtractive (milled), additive (3D printed) conventional denture base resins. In order to answer the developed PICO question: "Does CAD-CAM milled and 3D printed denture base resins have microbiological antiadherence properties over the conventional ones?" We included comparative studies on digitally fabricated Denture base resins with conventionally fabricated one in term of microbial adhesion. Methods: All in vitro studies investigated the microbial adherence to CAD-CAM milled and 3D printed denture base resins in comparison to conventional were searched in the PubMed, Web of Sciences, and Scopus databases up to December 2023. Results: Fifteen studies have been investigated the microbial adhesion to milled and 3D printed denture base resins. CAD-CAM milled resins significantly decreased the microbial adhesion when compared with the conventional resins and 3D printed resins, while the later showed a high tendency for microbial adhesion. The addition of antifungal agents to 3D printed resins significantly reduced C. albicans adhesion. In terms of 3D printing parameters, printing orientation affected adherence while printing technology had no effect on microbial adhesion. Conclusion: Denture base materials and fabrication methods significantly affect the microbial adhesion. CAD-CAM milled denture base resins demonstrated low microbial adhesion. 3D-printed resins showed high tendency for C. albicans adhesion. The antiadherent properties of 3D-printed resins can be improved by incorporating antifungal agents or changing the printing parameters, but further investigations are required to validate these modifications.

2.
Work ; 77(2): 407-416, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37718829

RESUMEN

BACKGROUND: Coronavirus disease 2019 (COVID-19) has badly affected the mental health, quality of life, and self-esteem of students worldwide. OBJECTIVE: The current study aimed to evaluate the psychological impact and self-esteem of dental students using Rosenberg self-esteem scale and PIDAQ during the COVID-19 pandemic. METHOD: This cross-sectional research was conducted amongst the dental students studying at various dental colleges in Karachi, Pakistan from January to May 2022. Evaluation of psychological aspect and self-esteem of students was carried out using "Psychosocial Impact of Dental Aesthetics Questionnaire (PIDAQ)", and "Rosenberg self-esteem scale" as perceived by students during the pandemic. For data analysis SPSS v24 was used. Data analysis comprised of descriptive analysis, Spearman correlation, One-way Anova and Linear regression. The level of significance of p value was less than 0.05. RESULTS: Overall 332 students participated, among which there were 181 females (54.5%), 151 males (45.5%). Dental self-confidence showed a negative relationship with social influence, psychological effect, and aesthetic concern, while it was positively linked with self-esteem during the pandemic. Social impact demonstrated association with psychological impact, aesthetic concern, and self-esteem, while it was negatively correlated with dental confidence. Rosenberg score showed positive correlation with all the variables. Statistically significant association was identified for variables when compared with gender. Regression analysis indicated association of age with dental confidence and RSS, while gender with social influence. CONCLUSION: The pandemic, aside from affecting the health of individuals worldwide, also badly affected the well-being, mental health, and self-esteem of the dental students. Dental aesthetics plays a crucial role in the mental wellbeing and self-esteem of the students.


Asunto(s)
COVID-19 , Maloclusión , Masculino , Femenino , Humanos , Maloclusión/psicología , Estudiantes de Odontología , Calidad de Vida , Estudios Transversales , Pandemias , COVID-19/epidemiología , Autoimagen , Estética Dental
3.
Int J Biomater ; 2023: 5077785, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37159616

RESUMEN

Background: This study aimed to evaluate the effects of different denture cleansing solutions (DCSs) on the retention of Locator and Locator R-Tx attachment systems of implant retained overdentures (IRO). Methods: Two part acrylic resin blocks were fabricated, upper part contained metal housing and plastic inserts and lower part contained implant analogs and abutments. Eighty pink plastic inserts (40/attachment, 10/solution) were immersed in Corega, Fittydent, sodium hypochlorite, and water for a time simulating upto 1-year of clinical usage. Acrylic blocks were held on a universal testing machine for a pull-out test to record the dislodgement force. Measurements were conducted after 6 months (T1) and 12 months (T2). One-way ANOVA followed by Tukey's HSD test was used to analyze the results (α = 0.05). Results: For both attachments, retention significantly decreased after immersion in different solutions at T2 (P < 0.001). Locator R-Tx attachment in NaOCl showed a significant decrease in retention compared with other solutions at T1. At T2, there was a significant decrease in retention for all DCS compared with water (P < 0.001). Locator R-TX showed higher retention values per solution compared to Locator attachment (P < 0.001). In terms of retention loss %, NaOCl recorded the highest (61.87%) loss, followed by Corega (55.54%) and Fittydent (43.13%), whereas water demonstrated the best retention (16.13%) in both groups. Conclusion: Locator R-TX has better retention with different DCS immersion. The loss of retention varied with different types of DCS and NaOCl recorded the highest retention loss. Therefore, denture cleanser selection must be guided by the type of IRO attachment.

4.
Photodiagnosis Photodyn Ther ; 42: 103526, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36996965

RESUMEN

AIM: Evaluation of the push-out bond strength (PBS) of glass fiber reinforced post (GFRP) bonded to root dentin after canal disinfection using food-based root canal irrigants i.e., Curcumin photosensitizer (CP), Riboflavin photosensitizer (RFP), Morinda ctrifolia juice (MCJ) and Sapindus mukorossi (SM) along with MTAD as a final irrigant. MATERIAL METHODS: Fifty human single-rooted premolar teeth were decoronated. Endodontic preparation was performed along with 2.25% sodium hypochlorite NaOCl solution followed by EDTA solution. Canals were dried and obturated followed by post-space preparation by removing GP. Specimens were allocated into five groups based on different food-based disinfection regimes (n = 10). Group 1: 2.25% NaOCl + MTAD (Control), Group 2: 6% MCJ + MTAD, Group 3: SM + MTAD, Group 4: CP + MTAD and Group 5: RFP + MTAD. All GFRP were bonded to radicular dentin. Root sectioning was performed followed by PBS and failure analysis using a universal testing machine (UTM) and stereomicroscope respectively. The data were analyzed using a one-way analysis of variance (ANOVA) test and the Post Hoc Tukey HSD test (p = 0.05). RESULTS: Samples disinfected with(MCJ+MTAD) at coronal third demonstrated maximum PBS (9.41 ± 0.51 MPa). However, the apical third of group 5 (RFP + MTAD) exhibited the minimum values (4.06 ± 0.23 MPa). Intergroup comparison analysis unveiled that group 2 (MCJ +MTAD) and group 3 (SM+MTAD) displayed comparable outcomes of PBS at all three-thirds. Similarly, samples in group 1 (2.25% NaOCl + MTAD), group 4 (CP + MTAD), and group 5 (RFP + MTAD) exhibited comparable PBS. CONCLUSION: Fruit-based irrigants Morinda citrifolia and Sapindus mukorossi have the potential to be used as root canal irrigants with a positive influence on bond strength.


Asunto(s)
Curcumina , Morinda , Fotoquimioterapia , Sapindus , Humanos , Irrigantes del Conducto Radicular/farmacología , Fármacos Fotosensibilizantes/farmacología , Especias , Fotoquimioterapia/métodos , Dentina , Ensayo de Materiales , Cavidad Pulpar
5.
BMC Oral Health ; 22(1): 526, 2022 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-36424586

RESUMEN

BACKGROUND: There are no studies that have assessed advanced glycation end products (AGEs) and interleukin 17A (IL-17A) levels in whole saliva (WS) of patients with dental implants. The aim was to compare levels of AGEs and IL-17A in WS and peri-implant clinical and radiographic status of patients with and without osteoporosis at 6-years' follow-up. METHODS: Osteoporotic (Group-1) and systemically healthy controls (Group-2) having undergone dental implant therapy at least 5 years ago were included. A questionnaire was used to collect information about age, gender, duration and treatment of osteoporosis, number and duration of implants in function, and frequencies of toothbrushing, flossing and hygiene visits. Modified bleeding and plaque indies (mBI and mPI), peri-implant probing depth (PD) and crestal bone loss (CBL) were recorded. WS was collected and levels of AGEs and IL-17A were determined using enzyme linked immunosorbent assay. Sample-size estimation was done and statistical analyses were doing using the independent t- and Wilcoxon rank-sum tests. Statistical significance was marked for P-values that were below 0.01. RESULTS: In patients with (n = 24) and without (n = 27) osteoporosis, implants were in function for 6.3 ± 0.27 and 6.6 ± 0.5 years, respectively. There was no significant difference in peri-implant mBI, PD, mPI and CBL in both groups. Levels of AGE in patients with (119.6 ± 26.5 µg/ml) and without (91.5 ± 14.6 µg/ml) osteoporosis were comparable. Levels of whole salivary IL-17A in patients without and with osteoporosis were 4.6 ± 0.3 and 5.1 ± 0.8 pg/ml, respectively. Flossing of full mouth interproximal spaces once and twice daily toothbrushing daily was reported by 100% patients with osteoporosis. Among patients with osteoporosis 75% and 25% individuals were receiving professional dental prophylaxis every 4 and 6 months, respectively. CONCLUSION: Within the limitations of the present study osteoporotic patients are not at an increased risk of peri-implant diseases and can demonstrate salivary AGE and IL-17A levels comparable to non-osteoporotic individuals as long as oral hygiene is stringently maintained.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Osteoporosis , Humanos , Interleucina-17 , Pérdida de Hueso Alveolar/diagnóstico por imagen , Productos Finales de Glicación Avanzada , Implantes Dentales/efectos adversos , Estudios de Seguimiento , Estudios Retrospectivos
6.
Dent J (Basel) ; 10(6)2022 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-35735644

RESUMEN

ZrO2 nanoparticles (ZNPs) have excellent physical properties. This study investigated the fracture load of implant-supported, fixed cantilevered prosthesis materials, reinforced with ZNPs and various polymerization techniques, compared with conventional and CAD/CAM materials. Sixty specimens were made from two CAD/CAM; milled (MIL) (Ceramill TEMP); and 3D-printed (NextDent Denture 3D+). Conventional heat-polymerized acrylic resin was used to fabricate the other specimens, which were grouped according to their polymerization technique: conventionally (HP) and autoclave-polymerized (AP); conventionally cured and reinforced with 5 wt% ZNPs (HPZNP); and autoclave reinforced with 5 wt% ZNPs (APZNP). The specimens were thermocycled (5000 cycles/30 s dwell time). Each specimen was subjected to static vertical loading (1 mm/min) using a universal Instron testing machine until fracture. Scanning electron microscopy was used for fracture surface analyses. The ANOVA showed significant fracture load differences between all the tested groups (p = 0.001). The Tukey post hoc tests indicated a significant difference in fracture load between all tested groups (p ˂ 0.001) except HP vs. HPZNP and AP vs. MIL. APZNP had the lowest mean fracture load value (380.7 ± 52.8 N), while MIL had the highest (926.6 ± 82.8 N). The CAD/CAM materials exhibited the highest fracture load values, indicating that they could be used in long-term interim prostheses. Autoclave polymerization improved fracture load performance, whereas ZrO2 nanoparticles decreased the fracture load performance of cantilevered prostheses.

7.
Int J Dent ; 2022: 6118660, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35572357

RESUMEN

Background: Denture stomatitis has been linked to the adhesion and proliferation of Candida albicans (C. albicans) on denture bases, which is a common and recurrent problem in denture wearers. The current study aimed to evaluate the effect of incorporating caffeic acid phenethyl ester (CAPE) into autopolymerized polymethyl methacrylate (PMMA) acrylic resin on C. albicans adhesion, surface roughness, and hardness as well as the correlation between tested properties. Methods: Autopolymerized acrylic resin discs (N = 100, 50/C. albicans adhesion; 50/C. albicans surface roughness and hardness test) were fabricated in dimensions 15 × 2.5 mm, samples were categorized into 5 groups (n = 10) based on CAPE concentrations; unmodified (control), 2.5, 5, 10 and 15% wt of acrylic powder. Specimens were stored in distilled water for 48 h at 37°C. C. albicans adhesion was evaluated via direct culture method. Profilometer and Vickers hardness tester were used for surface roughness and hardness measurement. Post hoc Tukey's HSD with ANOVA test was performed to compare the difference of means amongst groups. P values were statistically significant at ≤0.05. Results: The addition of 2.5% of CAPE to PMMA has significantly reduced C. albicans counts in comparison to higher CAPE concentrations (p < 0.001). As for surface roughness, it was noticed that it increased with increased CAPE concentrations (p < 0.0001). While surface hardness decreased as CAPE concentrations increased (p < 0.0001). All tested properties showed a significant difference amongst groups for C. albicans colony count and surface parameters. Conclusion: The addition of 2.5% of CAPE to PMMA acrylic resin significantly decreased C. albicans count compared to higher CAPE concentrations. CAPE can be used as an adjunct in the prevention of DS by incorporating in the PMMA acrylic resin.

8.
Photodiagnosis Photodyn Ther ; 39: 102859, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35417788

RESUMEN

OBJECTIVE: The study aimed to evaluate the effect of different post surface pretreatment methods i.e., 24% hydrogen peroxide (H2O2), riboflavin photosensitizer (RFP), curcumin photosensitizer (CP) and aluminum oxide (Al2O3), and silane only on the bond values of glass fiber post to resin cement MATERIALS AND METHODS: Fifty single-rooted human teeth were obtained and crowns were sectioned coronally to the cementoenamel junction (CEJ). Protaper universal file system was used for canal cleaning and shaping followed by obturation. Post space was prepared and all the posts were then randomly divided into five groups depending on the surface pretreatment used (n = 10). Group 1: 24% H2O2 + silane, Group 2: RFP + silane, Group 3: CP + silane, Group 4: Al2O3 + silane, Group 5: silane only. Post-surface treatment was followed by post-placement using a self-etch dual-cure cement Panavia F 2.0. Acrylic blocks were used to hold the specimens perpendicularly and all the samples were sectioned by slow-speed saw into coronal, middle, and apical third. The universal testing machine determines pushout bond strength and failure mode was analyzed by stereomicroscope. One-way analysis of variance (ANOVA) and Tukey multiple comparison tests were used to analyze data. RESULT: The coronal section of group 4 (Al2O3 + silane) displayed the highest PBS (8.23±0.14 MPa). Whereas, an apical third of group 2 (RFP + silane) exhibited the lowest PBS (2.02±0.12 MPa). PBS values in samples in group 1 surface treated with 24% H2O2 + silane displayed comparable outcomes to samples in group 4 at all three levels (p>0.05). Samples in group 2 (RFP + silane) group 3 (CP + silane) and group 5 (Silane Only) demonstrated comparable PBS (p>0.05). CONCLUSION: Glass fiber reinforced post-surface pretreatment method using hydrogen peroxide and aluminum trioxide along with silane improves push-out bond strength at all three levels (coronal, middle, and apical). The use of a silane coupling agent on glass fiber posts alone does not improve bond values. The practice of photosensitizer on post-surface needs to be investigated further.


Asunto(s)
Fotoquimioterapia , Técnica de Perno Muñón , Aluminio , Dentina , Humanos , Peróxido de Hidrógeno , Ensayo de Materiales , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Silanos/química
9.
Dent J (Basel) ; 10(3)2022 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-35323244

RESUMEN

This study aimed to evaluate the water sorption, solubility, and translucency of 3D-printed denture base resins (NextDent, FormLabs, and Asiga), compare them to heat-polymerized acrylic denture base resins, and assess their performance under the effects of thermal cycling. A total of 80 acrylic disc specimens were used in the current study, categorized into four groups (n = 10); in one group, the samples were fabricated conventionally with a heat-polymerizing process (control), while the other three groups were fabricated digitally from different 3D-printed reins (NextDent, FormLabs, and Asiga). Specimens were fabricated according to the manufacturers' recommendations and immersed in distilled water for 48 h at 37 °C. Data on water sorption, solubility, and translucency measurements (T1) were obtained. All the specimens were subjected to 5000 thermal cycles, and then the measures were repeated using the same method (T2). Data analysis was attained via ANOVA and the post hoc Tukey test (α = 0.05). The type of resin significantly affected the values of water sorption, solubility, and translucency (p < 0.001). The water sorption of 3D-printed resins was increased significantly in comparison to control with or without a thermal cycling effect. In terms of solubility, a significant increase in 3D-printed resins before thermocycling was observed; however, after thermocycling, Asiga had a significantly low value compared to the other groups (p < 0.001). Thermal cycling increased the water sorption and solubility of all tested materials. In comparison to control, the translucency of the 3D-printed resins was significantly decreased (p < 0.001). The translucency was significantly decreased per material in terms of the thermal cycling effect (before and after). NextDent showed significantly low translucency values (p < 0.001) compared to the other groups. All 3D-printed resin groups had higher water sorption and solubility and lower translucency values in comparison to the heat-polymerized resin group. Regardless of resin types, thermal cycling adversely affected all tested properties.

10.
Photodiagnosis Photodyn Ther ; 37: 102566, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34619385

RESUMEN

AIM: To assess the effectiveness of chemical, ultrasonic and photodynamic therapy (PDT) mediated disinfection against in-vitro biofilms colonized with C. albicans, S. oralis, and S. aureus on surfaces of PMMA (polymethylmethacrylate) denture base material. MATERIALS AND METHODS: Fifty plates of PMMA were prepared with two different surface topography (rough and polished) analyzed by profilometry. Provenance culture (ATCC) of C. albicans, S. oralis, and S. aureus were inoculated on specimens and exposed to disinfection. The disinfection included Rosebengal (RB) 5 µM activated by a red LED, 2% glutaraldehyde, 70% Isopropyl alcohol, ultrasonic disinfection, and saline solution as a control. The antimicrobial efficacy was assessed by subsequently calculating viable counts after disinfection. The data were analyzed using analysis of variance (ANOVA) and Tukey's Post Hoc test. RESULTS: The unpolished surface demonstrated the highest average surface roughness As 5.32±0.36 (µm) and root mean square roughness Rr 7.22±0.81 (µm) compared to the polished surface. Intergroup comparison demonstrated polished and rough PMMA plate disinfected with rose bengal, glutaraldehyde and alcohol-based disinfection exhibited comparable reduction against C. albicans and S. oralis CFU/mL (log10) (p>0.05). Whereas, this reduction was significantly higher on the rough and polished surface of PMMA when disinfected using ultrasounds for 30 sec (p<0.05). Rose Bengal was the most effective method of disinfection against S. aureus both on polished (0.17±0.13) and rough (0.44±0.22) denture plates (p<0.05). CONCLUSION: The ultrasonic disinfection was most effective in reducing viable microbial counts. RB mediated PDT exhibited a more substantial reduction of the colonies of S.aureus.


Asunto(s)
Desinfección , Fotoquimioterapia , Resinas Acrílicas/farmacología , Candida albicans , Bases para Dentadura , Desinfección/métodos , Glutaral/farmacología , Ensayo de Materiales , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Polimetil Metacrilato/farmacología , Staphylococcus aureus , Ultrasonido
11.
Oral Health Prev Dent ; 19(1): 503-510, 2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-34585876

RESUMEN

PURPOSE: Soluble urokinase plasminogen activator receptor (suPAR) and interleukin 1-beta (IL-1ß) are inflammatory biomarkers, whereas galectin-1 is an anti-inflammatory cytokine. The relationship between suPAR, galactin-1 and IL-1ß levels in peri-implant sulcular fluid (PISF) in relation to dental implants remains unaddressed. The aim was to assess suPAR, galectin-1, and IL-1ß levels in PISF under peri-implant inflammatory conditions. MATERIALS AND METHODS: Demographic data and information related to jaw location and duration of implants in function as well as systemic health was retrieved from patients' dental records. Peri-implant plaque and gingival indices (PI and GI, respectively), probing depth (PD) and crestal bone loss (CBL) were recorded. The PISF was collected and levels of suPAR, galectin-1 and IL-1ß were determined using standard techniques. Sample-size estimation and statistical analyses were done. Correlation of suPAR and galectin-1 with IL-1ß were assessed via logistic regression. p-values < 0.05 were considered statistically significant. RESULTS: Seventy-two patients (45 males and 27 females) with peri-implant diseases were included. Thirty-six patients (22 males and 14 females) had peri-implant mucositis; 36 (23 males and 13 females) had healthy peri-implant tissues. The PISF volume was statistically significantly higher among patients with (0.52 ± 0.05 µl) than without peri-implant diseases (0.06 ± 0.01 µl) (p < 0.001). The PISF levels of suPAR (p < 0.01), galectin-1 (p < 0.01) and IL-1ß (p < 0.01) were statistically significantly higher among patients with than without peri-implant diseases. In patients with peri-implant mucositis, PISF suPAR (p < 0.001) and galectin-1 (p < 0.001) levels correlated with PISF IL-1ß levels. In patients with peri-implant mucositis, increasing peri-implant PD and IL-1ß levels directly correlated with increased PISF suPAR (p < 0.001) and galectin-1 (p < 0.05) levels. CONCLUSION: Increased PISF levels of suPAR, galectin and IL-1ß suggest that these proteins possibly contribute towards the pathogenesis of peri-implant inflammation, and are potential biomarkers of peri-implant diseases.


Asunto(s)
Implantes Dentales , Receptores del Activador de Plasminógeno Tipo Uroquinasa , Índice de Placa Dental , Femenino , Galectina 1 , Líquido del Surco Gingival , Humanos , Masculino , Índice Periodontal
12.
Polymers (Basel) ; 13(10)2021 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-34066202

RESUMEN

The present study aimed to synthesize and equate the mechanical properties and dentin interaction of two adhesives; experimental adhesive (EA) and 5 wt.% reduced graphene oxide rGO) containing adhesive. Scanning electron microscopy (SEM)-Energy-dispersive X-ray spectroscopy (EDX), Micro-Raman spectroscopy, push-out bond strength test, and Fourier Transform Infrared (FTIR) spectroscopy were employed to study nano-bond strength, degree of conversion (DC), and adhesive-dentin interaction. The EA was prepared, and rGO particles were added to produce two adhesive groups, EA-rGO-0% (control) and rGO-5%. The canals of sixty roots were shaped and prepared, and fiber posts were cemented. The specimens were further alienated into groups based on the root canal disinfection technique, including 2.5% sodium hypochlorite (NaOCl), Photodynamic therapy (PDT), and ER-CR-YSGG laser (ECYL). The rGO nanoparticles were flake-shaped, and EDX confirmed the presence of carbon (C). Micro-Raman spectroscopy revealed distinct peaks for graphene. Push-out bond strength test demonstrated highest values for the EA-rGO-0% group after NaOCl and PDT conditioning whereas, rGO-5% showed higher values after ECYL conditioning. EA-rGO-0% presented greater DC than rGO-5% adhesive. The rGO-5% adhesive demonstrated comparable push-out bond strength and rheological properties to the controls. The rGO-5% demonstrated acceptable DC (although lower than control group), appropriate dentin interaction, and resin tag establishment.

13.
Photodiagnosis Photodyn Ther ; 35: 102362, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34062305

RESUMEN

AIM: The study aimed to assess the effect of in-vitro chlorhexidine and antimicrobial photodynamic therapy (aPDT) disinfection protocols against acrylic resin specimens colonized with S. mutans, S. aureus, E. coli, and C. albicans. MATERIAL AND METHODS: Reference strains of S. mutans, S. aureus, E. coli, and C. albicans were tested. Sixteen blocks of acrylic specimens were prepared by heat-cure acrylic resin and contaminated by in-vitro biofilm growth. Specimens in group 1, group 2 and group 3 were treated with Rose Bengal (RB), methylene blue (MB) 500 mg/L and porphyrin derivative (PD) 5 ml respectively, for the sensitization of biofilms. All photosensitizers (PS) were activated by LED at different wavelength. CHX was prepared in sterile distilled water and applied for 60 s. Each contaminated specimen was sprayed on all its surfaces with the aforementioned photosensitizers and control CHX. One-way analysis of variance (ANOVA) model was used to test the effect of the treatments and Tukey multiple comparison tests to compare means OF CFU/mL (log10) for exposed E. coli, C. albicans, S aureus, and S. mutans RESULTS: Specimens treated with 0.12% CHX (control) demonstrated a significant reduction in CFU/mL (log10) for exposed E. coli; 2.04±0.07 CFU/mL, C. albicans; 2.09±0.85 CFU/mL, S aureus; 3.04±0.11 CFU/mL, and S. mutans; 2.54±0.91 CFU/mL. The intragroup comparison revealed E.coli did not exhibit a decrease in reduction CFU/mL (log10) when acrylic resin irradiated with RB 5 µm. Whereas, CFU/mL (log10) values of S.aureus; 3.62±0.68 and S.mutans; 3.41±0.13 plummeted (p<0.05). Intergroup comparison showed E.coli values to display comparable reduction when disinfected with MB 500 mg/L and 0.12% CHX; 3.16±0.34 and 2.04±0.07 CFU/mL (log10) (p<0.05). CONCLUSION: Photosensitizers (RB, MB, PD) are selective in reducing bacterial count on acrylic resin blocks. CHX was found to be effective against all bacteria E.coli, C.albicans, S.aureus, and S.mutans at a concentration of 0.12%.


Asunto(s)
Fotoquimioterapia , Porfirinas , Resinas Acrílicas , Biopelículas , Dentaduras , Desinfección , Escherichia coli , Azul de Metileno/farmacología , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Polímeros , Rosa Bengala/farmacología , Staphylococcus aureus , Streptococcus mutans
14.
Dent Mater J ; 40(4): 972-978, 2021 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-33883327

RESUMEN

The aim of this study was to assess the translucency of denture base acrylic resin reinforced with zirconium dioxide (ZrO2NPs), silicon dioxide (SiO2NPs), and diamond (DNPs) nanoparticles. A total of 130 heat-polymerized acrylic discs (15×2.5 mm) were fabricated conventionally and divided into control and experimental groups according to nanoparticle type and concentration (0.5, 1, 1.5, and 2.5 wt%). Unmodified acrylic resin specimens served as control. All specimens were thermocycled (5,000 cycles). Translucency was measured using a spectrophotometer. ANOVA and post-hoc Turkeys' test were used for data analysis at α=0.05. The translucency of modified PMMA was significantly lower than control (p<0.05) except 0.5% ZrO2NPs and SiO2NPs (p>0.05) which exhibited the highest translucency values among modified groups. As the NPs concentration increased, the translucency decreased and the lowest value was seen with 2.5% DNPs (1.18±0.10). The addition of ZrO2NPs, SiO2NPs, and DNPs into denture base resin decreased the translucency.


Asunto(s)
Bases para Dentadura , Nanopartículas , Resinas Acrílicas , Ensayo de Materiales , Polimetil Metacrilato , Propiedades de Superficie
15.
Saudi Dent J ; 31(Suppl): S106-S111, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31061611

RESUMEN

Developmental enamel hypomineralization is a condition affect quality of enamel result in low translucency and opacity area that compromise patient smile. Lithium disilicate Emax prosthesis report a superior properties in esthetic treatment. This report is aimed to determine the effectiveness of lithium disilicate (E-max) prosthesis in managing esthetic demand of patient with enamel hypomineralized teeth.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...