1.
Technol Health Care ; 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38517819

RESUMEN

BACKGROUND: Denture stomatitis, frequently encountered, is generally addressed symptomatically, with limited exploration of preventive approaches involving antifungal medicinal plants. OBJECTIVE: This study assessed the impact of Artemisia sieberi extracts on the candida growth of conventional and digitally processed acrylic materials. METHOD: Thirty acrylic resin discs (3 mm thickness × 10 mm diameter) were prepared by conventional or CAD/CAM technology (milling and 3D printing). The resin discs were exposed to simulated brushing, thermocycling, and immersion in Artemisia sieberi extract for 8 hours. The surface roughness of the discs was assessed at baseline and after immersion in Artemisia sieberi extract. Candida growth was quantified through colony-forming units (CFU/mL). Data was analyzed using SPSS v.22 (α⩽ 0.05). RESULTS: Irrespective of the material type, the post-immersion surface roughness was significantly higher compared to pre-immersion values (p< 0.05). Candida growth was significantly higher in conventional acrylic materials than digitally fabricated acrylics (p< 0.05). At × 3, Ra and CFU were found to be moderately positive and non-significantly correlated (R= 0.664, p= 0.149). At × 4, Ra and CFU were found to be weak positive and non-significantly correlated (R= 0.344, p= 0.503). CONCLUSION: Artemisia sieberi extracts had a notable impact on digitally fabricated denture acrylics, reducing candida albicans growth compared to conventional heat-cured acrylic. This suggests a potential role for these extracts in improving denture hygiene and preventing denture stomatitis, particularly in the context of digitally fabricated dentures.

2.
Polymers (Basel) ; 15(2)2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36679340

RESUMEN

This study assessed the efficacy of five denture cleansers on the microbial adherence and surface topography of conventional and CAD/CAM denture base resins. Acrylic resin discs were fabricated using conventional, milling, and 3D printing methods (N = 180). The discs were contaminated with dual species of Candida albicans and Streptococcus mutans biofilm for 72 h and then disinfected with either of the denture cleansers (Fittydent cleansing tablets, 2% Chlorhexidine gluconate, 0.2% Chlorhexidine gluconate, 0.5% sodium hypochlorite, and 1% sodium hypochlorite (n = 10). Distilled water served as the control group. The colony-forming units of the microorganisms were calculated, followed by post-treatment surface roughness. Data were statistically analyzed using one-way ANOVA, paired t-test, and post hoc Tukey HSD test (α = 0.05). Among the denture cleansers, 2% Chlorhexidine gluconate, 0.5% sodium hypochlorite, and 1% sodium hypochlorite had the best cleansing effect on the resin discs and demonstrated zero growth of colonies for both the species. Comparing the material groups, the 3D-processed discs showed higher colony-forming units followed by the conventional and CAD/CAM milled group. The highest surface roughness was demonstrated by the 3D-printed discs (0.690 ± 0.08 µm), followed by the conventional (0.493 ± 0.11 µm) and the milled groups (0.301 ± 0.08 µm). The tested chemical denture cleansers affected the Candida albicans and Streptococcus mutans adhesion compared to control discs immersed in distilled water. The clinician may recommend to their patient to use 2% chlorhexidine gluconate for the disinfection of CAD/CAM PMMA denture base materials.

3.
Materials (Basel) ; 15(17)2022 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36079529

RESUMEN

This study aimed to measure the effect of storage environment on the hardness, surface roughness and wear ability of CAD/CAM resin-matrix ceramics. A total of 200 rectangular-shaped specimens were obtained by sectioning 5 CAD/CAM blocks; Crystal Ultra (CU), Vita Enamic (VE), Lava Ultimate (LU), Cerasmart (CS) and Vita blocks Mark II (MII). Microhardness and surface roughness were measured at baseline and after 7 days of immersion either in saliva or cola (n = 10). The wear ability of the CAD/CAM materials against steatite-ceramics antagonist was determined using a chewing simulator. The data were statistically analyzed using factorial ANOVA followed by post hoc Bonferroni multiple comparison tests (p < 0.05). The independent factors significantly influenced the microhardness and surface roughness (p < 0.05). The highest VHN was observed in MII at baseline (586.97 ± 13.95), while CU showed the lowest VHN after 7 days of immersion in cola (68.3 ± 1.89). On the contrary, the highest Ra was observed after 120,000 chewing cycles for the VE specimens (1.09 ± 0.43 µm) immersed in cola, while LU showed the lowest Ra at baseline (0.07 ± 0.01 µm). The highest % mass loss of the antagonist was observed with MII immersed in cola (1.801%), while CS demonstrated the lowest % mass loss of 0.004% and 0.007% in AS and cola, respectively. This study confirms that the surface properties of tested CAD/CAM materials are susceptible to degradation in an acidic environment except for hardness and wear of CS material.

4.
Materials (Basel) ; 15(14)2022 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-35888241

RESUMEN

Purpose: The present study evaluated the marginal gap of lithium disilicate crowns fabricated through three different wax pattern techniques; Conventional, Milling and 3D-printing. Materials and Methods: Thirty stone models were replicated from a stainless-steel model representing a prepared tooth; ten were sent to make conventional wax patterns while the remaining were sent to a digital dental scanner. The computer aided design was completed and STL (Standard Tessellation Language) files were sent to either milling or 3D-printing machines. All wax patterns (n = 30) were pressed, and a stabilizing instrument was used to secure the crowns on the master model. The marginal gap was measured at 18 points for each crown using a digital microscope (µm) (n = 540) and compared using One-way ANOVA (p ≤ 0.05). Results: There was a significant difference in the marginal gap value between all three groups (p < 0.01) where the milled group showed the least mean gap (28.87 ± 30.18 µm), followed by 3D printed (47.85 ± 27.44 µm), while the highest mean marginal gap was found in the conventional group (63.49 ± 28.05 µm). Conclusion: Milled and 3D-printed wax patterns produced better fitting crowns compared to conventional techniques.

5.
J Prosthet Dent ; 128(3): 497.e1-497.e9, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35864022

RESUMEN

STATEMENT OF PROBLEM: Information regarding the masking ability of computer-aided design and computer-aided manufacture (CAD-CAM) resin-matrix ceramic materials with different compositions is scarce. PURPOSE: The purpose of this in vitro study was to evaluate the effects of background color and thickness on the optical properties (color and translucency) of CAD-CAM resin-matrix ceramics. MATERIAL AND METHODS: Twelve rectangular specimens were fabricated at a different thickness (1, 1.5, and 2 mm) (n=12) from each of the resin-matrix ceramic materials: Shofu block (SB), Lava Ultimate (LU), CERASMART (CS), VITA ENAMIC (VE), Crystal Ultra (CU), and the VITABLOCS Mark II feldspathic ceramic (VB). The color of the specimens over amalgam, titanium, enamel, and dentin backgrounds was measured with a spectrophotometer, and the color differences (ΔE∗ab) were calculated by using the Commission Internationale de l'Eclairage (CIE) 76 formula. The difference in color of the specimen over the black and white backgrounds was used to calculate the translucency parameter (TP). ANOVA was used to statistically test whether material, background, and thicknesses influenced ΔE∗ab and TP values. Post hoc comparisons were performed to determine the significant difference among the groups (α=.05). RESULTS: The interaction with 2 between factors demonstrated that the material was a factor that significantly influenced ΔE∗ab (P<.001). The highest mean ±standard deviation of ΔE∗ab was recorded in the combination of VB material and 2-mm thickness (1.84 ±0.37), and the lowest with CS material with 1.5-mm thickness (0.47 ±0.24). The type of material and specimen thickness significantly influenced TP (P<.001). The highest and lowest mean ±standard deviation of TP were recorded for the 1-mm-thick CS (14.20 ±0.90) and 2-mm-thick SB (4.91 ±0.42) specimens, respectively. CONCLUSIONS: CERASMART resin-matrix ceramic and VITABLOCS Mark II feldspathic ceramic exhibited high and low masking abilities over the investigated background substrates, respectively. However, irrespective of the thickness, all study materials exhibited acceptable masking abilities.


Asunto(s)
Titanio , Cerámica/química , Color , Diseño Asistido por Computadora , Porcelana Dental/química , Ensayo de Materiales , Propiedades de Superficie
6.
Technol Health Care ; 30(1): 161-173, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34250915

RESUMEN

BACKGROUND: The use of 3D printed material in the dental field is gaining tremendous attention. However, studies related to 3D printed denture resins are scarce and need consideration before their inclusion in routine clinical practice. OBJECTIVE: This study aimed to assess the surface roughness (Ra) of 3D printed denture resins following aging and mechanical brushing. METHODS: Forty round samples (diameter, 10 mm and thickness, 3 mm) were fabricated from two 3D printed (DentaBASE and Denture 3D+) and one conventional polymethylmethacrylate (PMMA) denture materials. The samples were thermo-cycled, subjected to mechanical brushing, and later immersed in either artificial saliva (AS), coffee, cola, or lemon juice (n= 10) to simulate one and two years of oral use. Surface roughness (Ra) was determined using a non-contact profilometer and scanning electron microscope was used for qualitative analysis. The data was analyzed using SPSS v.20 (α= 0.05). RESULTS: Denture 3D+ demonstrated highest mean Ra (1.15 ± 0.28 µm), followed by PMMA (0.99 ± 0.50 µm) and DentaBASE (0.81 ± 24). The difference in mean Ra between the materials was statistically non-significant (P= 0.08). Amongst the different beverages used, the highest Ra was observed for samples immersed in lemon juice (1.06 ± 0.40 µm) followed by cola (1.04 ± 0.46 µm) and coffee (0.98 ± 0.40 µm), respectively. The lowest Ra was observed for samples immersed in AS (0.85 ± 0.24 µm). CONCLUSION: The surface roughness of 3D printed denture resins was comparable with that of conventional PMMA resins. Denture 3D+ demonstrated the highest mean roughness, followed by PMMA and DentaBASE.


Asunto(s)
Polimetil Metacrilato , Impresión Tridimensional , Bases para Dentadura , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
7.
J Adv Prosthodont ; 13(3): 160-171, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34234926

RESUMEN

PURPOSE: This in-vitro study evaluated and compared the color stability of 3D-printed and conventional heat-polymerized acrylic resins following aging, mechanical brushing, and immersion in staining medium. MATERIALS AND METHODS: Forty disc-shaped specimens (10 mm in diameter and 3 mm thick) were prepared from two 3D-printed [DentaBASE (DB) and Denture 3D+ (D3D)] and one conventional polymethylmethacrylate (PMMA) denture materials. The specimens were thermo-cycled, subjected to mechanical brushing, and were immersed in either coffee, lemon juice, coke, or artificial saliva (AS) to simulate one and two years of oral use. Color measurements of the specimens were recorded by a spectrophotometer at baseline (T0), and after one (T1) and two years (T2) of simulation. The color changes (∆E) were determined and also quantified according to the National Bureau of Standards (NBS) units. Descriptive statistics, followed by factorial ANOVA and Bonferroni post-hoc test (α=.05), were applied for data analysis. RESULTS: The independent factors, namely material, staining medium, and immersion time, and interaction among these factors significantly influenced ∆E (P<.009). Irrespective of the materials, treatments, and time, the highest and the lowest mean ∆Es were observed for PMMA in lemon juice (4.58 ± 1.30) and DB in AS (0.41 ± 0.18), respectively. Regarding the material type, PMMA demonstrated the highest mean ∆E (2.31 ± 1.37), followed by D3D (1.67 ± 0.66), and DB (0.85 ± 0.52), and the difference in ∆E between the materials were statistically significant (P<.001). All the specimens demonstrated a decreased color changes at T2 compared to T1, and this difference in mean ∆E was statistically significant (P<.001). CONCLUSION: The color changes of 3D-printed denture resins were low compared to conventional heat polymerized PMMA. All the tested materials, irrespective of the staining medium used, demonstrated a significant decrease in ∆E values over time.