Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Ophthalmol ; 32(6): 3333-3339, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35102752

RESUMEN

PURPOSE: To evaluate long-term efficacy, safety, predictability and stability (refractive and keratometric) of myopic and myopic astigmatism correction with Small Incision Lenticule Extraction (SMILE). METHODS: Single center retrospective review of eyes undergoing SMILE from 2012-2015. Forty-two eyes (23 patients) with ≥ 5-year follow-up. Variables analyzed were preoperative, 3-month, 1-year and last follow-up uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, spherical equivalent (SE) and mean keratometry. Descriptive statistics were performed and results reported following the Standard for Reporting Astigmatism Outcomes. RESULTS: Mean follow-up of 5.98 ± 0.90 years. Mean preoperative SE was -5.26 ± 1.22D (range -2.50 to -8.12D). Mean preoperative cylinder was -0.66 ± 0.61D (range 0.00 to -2.25D). Efficacy and safety indices were 0.86 and 0.98, respectively. In total, 81% of operated eyes achieved an UDVA of ≥ 0.09 logMar (20/25 Snellen). At the last follow-up, ≥1 line of CDVA was gained in 14% of eyes. Five percent lost 1 line of CDVA, and no eye loss ≥2 lines of CDVA. Sixty-nine percent of eyes were within ± 0.50D and 86% within ± 1.00D of the attempted SE correction. Ninety-one percent of eyes had ≤0.50D of postoperative astigmatism and 71% were within ± 15° from the intended correction axis. At the final follow-up, a statistically significant myopic regression of 0.19 ± 0.50D was observed (p = 0.01). CONCLUSIONS: Long-term results demonstrate that SMILE is effective, predictable and safe. SMILE has good stability, low regression compared to LASIK, and no signs of corneal ectasia staging within our standard criteria.


Asunto(s)
Astigmatismo , Queratomileusis por Láser In Situ , Miopía , Herida Quirúrgica , Astigmatismo/diagnóstico , Astigmatismo/cirugía , Sustancia Propia/cirugía , Estudios de Seguimiento , Humanos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/diagnóstico , Miopía/cirugía , Refracción Ocular , Herida Quirúrgica/cirugía , Resultado del Tratamiento
2.
Acta Ophthalmol ; 99(7): e973-e983, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33433050

RESUMEN

In the context of the COVID-19 pandemic, this paper provides recommendations for medical eye care during the easing of control measures after lockdown. The guidelines presented are based on a literature review and consensus among all Spanish Ophthalmology Societies regarding protection measures recommended for the ophthalmologic care of patients with or without confirmed COVID-19 in outpatient, inpatient, emergency and surgery settings. We recommend that all measures be adapted to the circumstances and availability of personal protective equipment at each centre and also highlight the need to periodically update recommendations as we may need to readopt more restrictive measures depending on the local epidemiology of the virus. These guidelines are designed to avoid the transmission of SARS-CoV-2 among both patients and healthcare staff as we gradually return to normal medical practice, to prevent postoperative complications and try to reduce possible deficiencies in the diagnosis, treatment and follow-up of the ophthalmic diseases. With this update (5th ) the Spanish Society of Ophthalmology is placed as one of the major ophthalmology societies providing periodic and systematized recommendations for ophthalmic care during the COVID-19 pandemic.


Asunto(s)
COVID-19/transmisión , Control de Enfermedades Transmisibles/métodos , Oftalmología/normas , Equipo de Protección Personal/normas , COVID-19/epidemiología , Consenso , Oftalmopatías/terapia , Humanos , Pandemias/prevención & control , Guías de Práctica Clínica como Asunto , SARS-CoV-2 , España , Telemedicina/métodos
3.
Vet Sci ; 6(1)2019 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-30791613

RESUMEN

Tibial Tuberosity Advancement (TTA) is a surgical technique based on a linear osteotomy that determines a cranial advancement of the tibial tuberosity in patients suffering from cranial cruciate ligament rupture (CCL). The aim is to neutralize the cranial tibial thrust (CTT) and to reach a 90° angle between the patellar tendon and the tibial plateau with a physiological knee extension of 135°. In our study, a Ti6AI4V ELI (Titanium Aluminium Vanadium) titanium scaffold for the Porous TTA, with excellent properties of osteointegration and osteoconduction when subjected to cyclic loading has been adopted. Based on the previous scientific work on an ovine model, the use of this type of porous scaffolds has subverted the previous models. Scaffold production technology is based on direct mechanical manufacturing called Electron Beam Melting (EBM). For this study, 41 dogs, different breeds, medium-large size, weighing between 10 and 80 kg, aged between 1 and 13 years, were enrolled. The inclusion criteria were based on clinical evaluations (different gaits), drawer test and tibial compression, LOAD score (Liverpool Osteoarthritis in Dogs questionnaire), radiographic diagnosis in sedation with a 135° positioning of the joint and baropodometric investigations (Stance Analyzer). The results show that Porous TTA is an excellent method for functional recovery of the knee joint following the partial and total rupture of the CCL.

4.
Nanoscale ; 8(37): 16662-16669, 2016 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-27714111

RESUMEN

Among various cancers, pediatric brain tumors represent the most common cancer type in children and the second most common cause of cancer related deaths. Anticancer drugs and therapies, such as doxorubicin (Dox), have severe side effects on patients during chemotherapy, especially for children as their bodies are still under development. These side effects are believed to be due to the lack of a delivery system with high efficacy and targeting selectivity, resulting in serious damages of normal cells. To improve the efficacy and selectivity, the transferrin (Trans) receptor mediated endocytosis can be utilized for drug delivery system design, as transferrin receptors are expressed on the blood brain barrier (BBB) and often over expressed in brain tumor cells. Carbon dots (C-Dots) have recently emerged as benign nanoparticles in biomedical applications owing to their good water solubility, tunable surface functionalities and excellent biocompatibility. The unique characteristics of C-Dots make them promising candidates for drug delivery development. In this study, carbon dots-transferrin-doxorubicin covalent conjugate (C-Dots-Trans-Dox) was synthesized, characterized by different spectroscopic techniques and investigated for the potential application as a drug delivery system for anticancer drug doxorubicin to treat pediatric brain tumors. Our in vitro results demonstrate greater uptake of the C-Dots-Trans-Dox conjugate compared to Dox alone presumably owing to the high levels of transferrin receptors on these tumor cells. Experiment showed that C-Dots-Trans-Dox at 10 nM was significantly more cytotoxic than Dox alone, reducing viability by 14-45%, across multiple pediatric brain tumor cell lines.


Asunto(s)
Carbono , Doxorrubicina/administración & dosificación , Sistemas de Liberación de Medicamentos , Nanopartículas , Transferrina , Neoplasias Encefálicas/tratamiento farmacológico , Línea Celular Tumoral , Humanos , Nanoconjugados
5.
Data Brief ; 6: 153-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26858981

RESUMEN

A novel bioactive glass scaffold ICIE16/BSG has been prepared from a mixture of two different melt-derived glasses: a silicate bioglass (ICIE16) and a borosilicate bioglass (BSG). Combined processing techniques (gel casting and foam replication) were used to form three-dimensional, interconnected porous monolith scaffolds (Orgaz et al., 2016) [1]. They were then nitrided with a hot ammonia flow as described in (Aleixandre et al., 1973) [3] and (Nieto, 1984) [4] to synthesize the ICIE16/BSG-NITRI bioglass (Orgaz et al., 2016) [1]. Herein we present a flow chart summarizing the forming process, plus images of the resulting scaffold after sintering and drying. Bioactivity was characterized in vitro by immersion in simulated body fluid (SBF) for up to seven days. Data of ionic release kinetics upon SBF immersion are presented.

6.
Acta Biomater ; 29: 424-434, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26441124

RESUMEN

Novel bioactive amorphous glass-glass composite scaffolds (ICIE16/BSG) with interconnected porosity have been developed. Hierarchically interconnected porous glass scaffolds were prepared from a mixture of two melt-derived glasses: a ICIE16 bioactive glass that was previously developed by Wu et al. (2011) to prevent crystallization, and a borosilicate glass of composition 73.48 SiO2-11.35 B2O3-15.15 Na2O (wt%). The resulting melt derived glass-glass composite scaffolds (ICIE16/BSG) were subject to surface functionalization to further improve its interaction with biological systems. Surface functionalization was performed by a nitridation process with hot gas N2/ammonia at 550°C for 2h, obtaining the ICIE16/BSG-NITRI. Evaluation of the degradation rate and the conversion to hydroxyapatite after immersion in simulated body fluid predicted a good biological activity of all the scaffolds, but particularly of the nitrided ones. In vitro evaluation of osteoblastic cells cultured onto the nitrided and non-nitrided scaffolds showed cell attachment, proliferation and differentiation on all scaffolds, but both proliferation and differentiation were improved in the nitrided ICIE16/BSG-NITRI. STATEMENT OF SIGNIFICANCE: Biomaterials are often required in the clinic to stimulate bone repair. We have developed a novel bioglass (ICIE16/SBG-NITRI) that can be sintered into highly porous 3D scaffolds, and we have further improved its bioactivity by nitridation. ICIE16/SBG-NITRI was synthesized from a mixture of two melt-derived glasses through combined gel casting and foam replication techniques, followed by nitridation. To mimic bone, it presents high-interconnected porosity while being mechanically stable. Nitridation improved its reactivity and bioactivity facilitating its resorption and the deposition of apatite (bone-like mineral) on its surface and increasing its degradation rate. The nitrided surface also improved the bioglass' interaction with bone cells, which were found to attach better to ICIE16/SBG-NITRI and to differentiate earlier on its surface.


Asunto(s)
Cerámica , Osteoblastos/metabolismo , Silicatos , Andamios del Tejido/química , Amoníaco/química , Animales , Línea Celular , Cerámica/química , Cerámica/farmacología , Ratones , Nitrógeno/química , Osteoblastos/citología , Silicatos/química , Silicatos/farmacología , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...