Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Insights Imaging ; 15(1): 8, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38228979

RESUMEN

PURPOSE: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. METHODS: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. RESULT: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. CONCLUSION: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. CRITICAL RELEVANCE STATEMENT: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. KEY POINTS: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score ( https://metricsscore.github.io/metrics/METRICS.html ) and a repository created to collect feedback from the radiomics community ( https://github.com/metricsscore/metrics ).

2.
Eur Radiol ; 34(4): 2791-2804, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37733025

RESUMEN

OBJECTIVES: To investigate the intra- and inter-rater reliability of the total radiomics quality score (RQS) and the reproducibility of individual RQS items' score in a large multireader study. METHODS: Nine raters with different backgrounds were randomly assigned to three groups based on their proficiency with RQS utilization: Groups 1 and 2 represented the inter-rater reliability groups with or without prior training in RQS, respectively; group 3 represented the intra-rater reliability group. Thirty-three original research papers on radiomics were evaluated by raters of groups 1 and 2. Of the 33 papers, 17 were evaluated twice with an interval of 1 month by raters of group 3. Intraclass coefficient (ICC) for continuous variables, and Fleiss' and Cohen's kappa (k) statistics for categorical variables were used. RESULTS: The inter-rater reliability was poor to moderate for total RQS (ICC 0.30-055, p < 0.001) and very low to good for item's reproducibility (k - 0.12 to 0.75) within groups 1 and 2 for both inexperienced and experienced raters. The intra-rater reliability for total RQS was moderate for the less experienced rater (ICC 0.522, p = 0.009), whereas experienced raters showed excellent intra-rater reliability (ICC 0.91-0.99, p < 0.001) between the first and second read. Intra-rater reliability on RQS items' score reproducibility was higher and most of the items had moderate to good intra-rater reliability (k - 0.40 to 1). CONCLUSIONS: Reproducibility of the total RQS and the score of individual RQS items is low. There is a need for a robust and reproducible assessment method to assess the quality of radiomics research. CLINICAL RELEVANCE STATEMENT: There is a need for reproducible scoring systems to improve quality of radiomics research and consecutively close the translational gap between research and clinical implementation. KEY POINTS: • Radiomics quality score has been widely used for the evaluation of radiomics studies. • Although the intra-rater reliability was moderate to excellent, intra- and inter-rater reliability of total score and point-by-point scores were low with radiomics quality score. • A robust, easy-to-use scoring system is needed for the evaluation of radiomics research.


Asunto(s)
Radiómica , Lectura , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
3.
Eur J Radiol ; 167: 111080, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37683331

RESUMEN

PURPOSE: The objective of this study was to assess the inappropriateness rate of oncological follow-up CT examinations. METHODS: Out of 7.000 oncology patients referred for follow-up CT examinations between March and October 2022, a random sample of 10 % was included. Radiology residents assessed the appropriateness using the Italian Society of Medical Oncology (AIOM) guidelines, supervised by senior radiologists. Association between inappropriateness and clinical variables was investigated and variables influencing inappropriateness were analyzed through a binary logistic regression. RESULTS: Three-hundred-eighty-eight examinations (56.1 %) were consistent with AIOM guidelines. An additional 100 (14.5  %) examinations did not follow the recommended schedule but were nevertheless considered appropriate because of suspected recurrence/progression (10.7 %) or adverse event requiring imaging assessment (3.8 %). Two-hundred-four (29.4 %) examinations were rated as inappropriate. Inappropriateness causes were as follows: CT not included in the relevant guideline (n = 47); CT extended to additional anatomical regions (n = 59); CT requested at a shorter time-interval (n = 98). No statistically significant difference was found in age, sex, scan region, and primary cancer between appropriate and inappropriate examinations. The only variable significantly associated with inappropriateness was being referred by a specific hospital unit named "unit 2" in the study (p = 0.009), which was demonstrated to be the only appropriateness independent predictor (OR 1.952). CONCLUSION: This study shows that majority of oncological patients referred for follow-up CT follows standard guidelines. However, a non-negligible proportion was rated as inappropriate, mainly due to the shorter time-interval. No clinical variable was associated with inappropriateness, except for referral by a specific hospital unit.


Asunto(s)
Oncología Médica , Examen Físico , Humanos , Estudios Transversales , Estudios de Seguimiento , Tomografía Computarizada por Rayos X
5.
Diagnostics (Basel) ; 13(16)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37627882

RESUMEN

The spleen, often referred to as the "forgotten organ", plays numerous important roles in various diseases. Recently, there has been an increased interest in the application of radiomics in different areas of medical imaging. This systematic review aims to assess the current state of the art and evaluate the methodological quality of radiomics applications in spleen imaging. A systematic search was conducted on PubMed, Scopus, and Web of Science. All the studies were analyzed, and several characteristics, such as year of publication, research objectives, and number of patients, were collected. The methodological quality was evaluated using the radiomics quality score (RQS). Fourteen articles were ultimately included in this review. The majority of these articles were published in non-radiological journals (78%), utilized computed tomography (CT) for extracting radiomic features (71%), and involved not only the spleen but also other organs for feature extraction (71%). Overall, the included papers achieved an average RQS total score of 9.71 ± 6.37, corresponding to an RQS percentage of 27.77 ± 16.04. In conclusion, radiomics applications in spleen imaging demonstrate promising results in various clinical scenarios. However, despite all the included papers reporting positive outcomes, there is a lack of consistency in the methodological approaches employed.

6.
Eur J Radiol Open ; 11: 100505, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37484979

RESUMEN

Objectives: To develop a mutation-based radiomics signature to predict response to imatinib in Gastrointestinal Stromal Tumors (GISTs). Methods: Eighty-two patients with GIST were enrolled in this retrospective study, including 52 patients from one center that were used to develop the model, and 30 patients from a second center to validate it. Reference standard was the mutational status of tyrosine-protein kinase (KIT) and platelet-derived growth factor α (PDGFRA). Patients were dichotomized in imatinib sensitive (group 0 - mutation in KIT or PDGFRA, different from exon 18-D842V), and imatinib non-responsive (group 1 - PDGFRA exon 18-D842V mutation or absence of mutation in KIT/PDGFRA). Initially, 107 texture features were extracted from the tumor masks of baseline computed tomography scans. Different machine learning methods were then implemented to select the best combination of features for the development of the radiomics signature. Results: The best performance was obtained with the 5 features selected by the ANOVA model and the Bayes classifier, using a threshold of 0.36. With this setting the radiomics signature had an accuracy and precision for sensitive patients of 82 % (95 % CI:60-95) and 90 % (95 % CI:73-97), respectively. Conversely, a precision of 80 % (95 % CI:34-97) was obtained in non-responsive patients using a threshold of 0.9. Indeed, with the latter setting 4 patients out of 5 were correctly predicted as non-responders. Conclusions: The results are a first step towards using radiomics to improve the management of patients with GIST, especially when tumor tissue is unavailable for molecular analysis or when molecular profiling is inconclusive.

7.
Front Radiol ; 3: 1141499, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37492385

RESUMEN

The aim of this systematic review was to evaluate the state of the art of radiomics in testicular imaging by assessing the quality of radiomic workflow using the Radiomics Quality Score (RQS) and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). A systematic literature search was performed to find potentially relevant articles on the applications of radiomics in testicular imaging, and 6 final articles were extracted. The mean RQS was 11,33 ± 3,88 resulting in a percentage of 31,48% ± 10,78%. Regarding QUADAS-2 criteria, no relevant biases were found in the included papers in the patient selection, index test, reference standard criteria and flow-and-timing domain. In conclusion, despite the publication of promising studies, radiomic research on testicular imaging is in its very beginning and still hindered by methodological limitations, and the potential applications of radiomics for this field are still largely unexplored.

8.
Eur J Radiol Open ; 11: 100511, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37520768

RESUMEN

Background: The new immunotherapies have not only changed the oncological therapeutic approach but have also made it necessary to develop new imaging methods for assessing the response to treatment. Delta radiomics consists of the analysis of radiomic features variation between different medical images, usually before and after therapy. Purpose: This review aims to evaluate the role of delta radiomics in the immunotherapy response assessment. Methods: A systematic search was performed in PubMed, Scopus, and Web Of Science using "delta radiomics AND immunotherapy" as search terms. The included articles' methodological quality was measured using the Radiomics Quality Score (RQS) tool. Results: Thirteen articles were finally included in the systematic review. Overall, the RQS of the included studies ranged from 4 to 17, with a mean RQS total of 11,15 ± 4,18 with a corresponding percentage of 30.98 ± 11.61 %. Eleven articles out of 13 performed imaging at multiple time points. All the included articles performed feature reduction. No study carried out prospective validation, decision curve analysis, or cost-effectiveness analysis. Conclusions: Delta radiomics has been demonstrated useful in evaluating the response in oncologic patients undergoing immunotherapy. The overall quality was found law, due to the lack of prospective design and external validation. Thus, further efforts are needed to bring delta radiomics a step closer to clinical implementation.

9.
Gastroenterol Clin North Am ; 52(1): 185-200, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36813425

RESUMEN

Coronavirus disease 2019 (COVID-19) pulmonary involvement has been extensively reported in the literature. Current data highlight how COVID-19 is a systemic disease, affecting many other organs, including the gastrointestinal, hepatobiliary, and pancreatic organs. Recently, these organs have been investigated using imaging modalities of ultrasound and particularly computed tomography. Radiological findings of the gastrointestinal, hepatic, and pancreatic involvement in patients with COVID-19 are generally nonspecific but are nonetheless helpful to evaluate and manage COVID-19 patients with involvement of these organs.


Asunto(s)
COVID-19 , Oncología por Radiación , Humanos , SARS-CoV-2 , Tracto Gastrointestinal , Hígado , Páncreas , Prueba de COVID-19
11.
Eur Urol Oncol ; 4(6): 855-862, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33893066

RESUMEN

BACKGROUND: Urological guidelines recommend multiparametric magnetic resonance imaging (mpMRI) in men with a suspicion of prostate cancer (PCa). The resulting increase in MRI demand might place health care systems under substantial stress. OBJECTIVE: To determine whether single-plane biparametric MRI (fast MRI) workup could represent an alternative to mpMRI in the detection of clinically significant (cs) PCa. DESIGN, SETTING, AND PARTICIPANTS: Between April 2018 and February 2020, 311 biopsy-naïve men aged ≤75 yr with PSA ≤15 ng/ml and negative digital rectal examination were randomly assigned to 1.5-T fast MRI (n = 213) or mpMRI (n = 98). INTERVENTION: All MRI examinations were classified according to Prostate Imaging-Reporting and Data System (PI-RADS) version 2. Men scored PI-RADS 1-2 underwent 12-core standard biopsy (SBx) and those with PI-RADS 4-5 on fast MRI or PI-RADS 3-5 on mpMRI underwent targeted biopsy in combination with SBx. Equivocal cases on fast MRI (PI-RADS 3) underwent mpMRI and then biopsy according to the findings. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The primary outcome was to compare the detection rate of csPCa in both study arms, setting a 10% difference for noninferiority. The secondary outcome was to assess the role of prostate-specific antigen density (PSAD) in ruling out men who could avoid biopsy among those with equivocal findings on fast MRI. RESULTS AND LIMITATIONS: The overall MRI detection rate for csPCa was 23.5% (50/213; 95% confidence interval [CI] 18.0-29.8%) with fast MRI and 32.7% (32/98; 95% CI 23.6-42.9%) with mpMRI (difference 9.2%; p = 0.09). The reproducibility of the study could have been affected by its single-center nature. CONCLUSIONS: Fast MRI followed by mpMRI in equivocal cases is not inferior to mpMRI in the detection of csPCa among biopsy-naïve men aged ≤75 yr with PSA ≤15 ng/ml and negative digital rectal examination. These findings could pave the way to broader use of MRI for PCa diagnosis. PATIENT SUMMARY: A faster MRI (magnetic resonance imaging) protocol with no contrast agent and fewer scan sequences for examination of the prostate is not inferior to the typical MRI approach in the detection of clinically significant prostate cancer. If our findings are confirmed in other studies, fast MRI could represent a time-saving and less invasive examination for men with suspicion of prostate cancer. This trial is registered at ClinicalTrials.gov as NCT03693703.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Biopsia , Humanos , Imagen por Resonancia Magnética , Masculino , Antígeno Prostático Específico , Neoplasias de la Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA