Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cureus ; 14(10): e30579, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36426330

RESUMEN

Introduction To establish a centralized inventory management system for the efficient functioning of all healthcare facilities, e-Upkaran (equipment management and maintenance system) was launched in 2015 in the state of Rajasthan. This study is conducted to assess the functioning of e-Upkaran in Rajasthan. Methods The assessment of the e-Upkaran system for primary and secondary healthcare centers was carried out using a systematic review of the literature and a multi-indicator stakeholder questionnaire. The benefits evaluation framework focused on the system quality, information and service quality, use and user satisfaction, and net benefits utilized for the assessment. A review of the literature was done to highlight the importance of computerized medical equipment management and maintenance systems and appraise the challenges and benefits associated with such systems as compared to the traditional pen-paper register. Information was gathered based on available documents, field observation, and data obtained from specific hospital staff, including the bioengineers and other users of e-Upkaran. Results The finding of this study suggests that e-Upkaran efficiently improves documentation, reporting, maintenance, and management of medical equipment. It is more efficient than the traditional paper-pen system. It is designed to minimize downtime and maintain equipment in good operating condition and has potential benefits in terms of improving information quality, use, and net benefit. The cost of service ratio is within the benchmark value. This system has also considerably reduced out-of-pocket expenditure. Computer proficiency and the workload of other e-health programs pose a challenge in the implementation of this program. Conclusion The e-Upkaran system is competent in terms of improving information quality, use, and net benefit. Other Indian states could also adopt this system to improve their biomedical equipment management and maintenance system.

2.
Hypertension ; 77(3): 806-812, 2021 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-33517681

RESUMEN

High systolic blood pressure (BP) is the single leading modifiable risk factor for death worldwide. Accurate BP measurement is the cornerstone for screening, diagnosis, and management of hypertension. Inaccurate BP measurement is a leading patient safety challenge. A recent World Health Organization report has outlined the technical specifications for automated noninvasive clinical BP measurement with cuff. The report is applicable to ambulatory, home, and office devices used for clinical purposes. The report recommends that for routine clinical purposes, (1) automated devices be used, (2) an upper arm cuff be used, and (3) that only automated devices that have passed accepted international accuracy standards (eg, the International Organization for Standardization 81060-2; 2018 protocol) be used. Accurate measurement also depends on standardized patient preparation and measurement technique and a quiet, comfortable setting. The World Health Organization report provides steps for governments, manufacturers, health care providers, and their organizations that need to be taken to implement the report recommendations and to ensure accurate BP measurement for clinical purposes. Although, health and scientific organizations have had similar recommendations for many years, the World Health Organization as the leading governmental health organization globally provides a potentially synergistic nongovernment government opportunity to enhance the accuracy of clinical BP assessment.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Monitoreo Ambulatorio de la Presión Arterial/métodos , Presión Sanguínea/fisiología , Hipertensión/fisiopatología , Brazo/fisiopatología , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/normas , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/normas , Humanos , Hipertensión/diagnóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Organización Mundial de la Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...