Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ultrasound Med Biol ; 49(5): 1091-1101, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36739244

RESUMEN

OBJECTIVE: There have been attempts to use therapeutic ultrasound (US) for the treatment of both experimental and clinical stroke. We hypothesized that low-intensity US has direct beneficial effects on the brain independent of cerebral blood flow (CBF) during middle cerebral artery occlusion (MCAO). METHODS: Three groups of mice were studied. Group I included 84 mice with MCAO undergoing US treatment/no treatment at two US frequencies (0.25 and 1.05 MHz) with three different acoustic pressures at each frequency in which infarct size (IS) was measured 24 h later. Group II included 11 mice undergoing treatment based on best US results from group I animals in which the IS/risk area (RA) ratio was measured 24 h later. Group III included 38 normal mice undergoing US treatment/no treatment for assessment of CBF, tissue metabolite and protein expression and histopathology. DISCUSSION: Ultrasound at both frequencies and most acoustic pressures resulted in reduction in IS in group I animals, with the best results obtained with 0.25 MHz at 2.0 MPa: IS was reduced 4-fold in the cerebral cortex, 1.5-fold in the caudate putamen and 3.5-fold in the cerebral hemisphere compared with control. US application in group III animals elicited only a marginal increase in CBF despite a 2.6-fold increase in phosphorylated endothelial nitric oxide synthase (p-eNOS)-S1177 and a corresponding decrease in p-eNOS-T494. Histopathology revealed no evidence of hemorrhage, inflammation or necrosis. CONCLUSION: Low-intensity US at specific frequencies and acoustic pressures results in marked neuroprotection in a mouse model of stroke by modulation of p-eNOS independent of its effect on CBF.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular , Ratones , Animales , Infarto de la Arteria Cerebral Media/terapia , Óxido Nítrico/metabolismo , Encéfalo/patología , Circulación Cerebrovascular , Modelos Animales de Enfermedad
2.
Data Brief ; 38: 107343, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34527795

RESUMEN

Cardiac endothelial cells respond to both ischemia and therapeutic ultrasound; the proteomic changes underlying these responses are unknown. This data article provides raw and processed data resulting from our global, unbiased phosphoproteomics investigation conducted on primary mouse cardiac endothelial cells exposed to ischemia (2-hour oxygen glucose deprivation) and ultrasound (250 kHz, 1.2 MPa) in vitro [1]. Proteins were extracted from cell lysates and enriched phosphopeptides were analyzed with a high mass accuracy liquid chromatrography (LC) - tandem mass spectrometry (MS/MS) proteomic platform, yielding multiple alterations in both total protein levels and phosphorylation events in response to ischemic injury and ultrasound. This dataset can be used as a reference for future studies on the cardiac endothelial response to ischemia and the mechanistic underpinnings of the cellular response to ultrasound, with the potential to yield clinically relevant therapeutic targets.

3.
Biochim Biophys Acta Proteins Proteom ; 1869(9): 140683, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34119693

RESUMEN

Myocardial infarction and subsequent therapeutic interventions activate numerous intracellular cascades in every constituent cell type of the heart. Endothelial cells produce several protective compounds in response to therapeutic ultrasound, under both normoxic and ischemic conditions. How endothelial cells sense ultrasound and convert it to a beneficial biological response is not known. We adopted a global, unbiased phosphoproteomics approach aimed at understanding how endothelial cells respond to ultrasound. Here, we use primary cardiac endothelial cells to explore the cellular signaling events underlying the response to ischemia-like cellular injury and ultrasound exposure in vitro. Enriched phosphopeptides were analyzed with a high mass accuracy liquid chromatrography (LC) - tandem mass spectrometry (MS/MS) proteomic platform, yielding multiple alterations in both total protein levels and phosphorylation events in response to ischemic injury and ultrasound. Application of pathway algorithms reveals numerous protein networks recruited in response to ultrasound including those regulating RNA splicing, cell-cell interactions and cytoskeletal organization. Our dataset also permits the informatic prediction of potential kinases responsible for the modifications detected. Taken together, our findings begin to reveal the endothelial proteomic response to ultrasound and suggest potential targets for future studies of the protective effects of ultrasound in the ischemic heart.


Asunto(s)
Endocardio/metabolismo , Isquemia Miocárdica/fisiopatología , Fosfoproteínas/metabolismo , Secuencia de Aminoácidos , Animales , Cromatografía Liquida/métodos , Endocardio/fisiología , Células Endoteliales/metabolismo , Corazón/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Ratones , Ratones Endogámicos C57BL , Fosforilación , Cultivo Primario de Células , Proteoma/metabolismo , Proteómica/métodos , Transducción de Señal , Espectrometría de Masas en Tándem/métodos , Terapia por Ultrasonido/métodos
4.
Am J Surg ; 221(6): 1271-1275, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33750572

RESUMEN

BACKGROUND: While often thought of as a diagnostic tool, ultrasound (US) can also potentially be used as a therapeutic modality. US applies mechanical stress on endothelial cells and induces nitric oxide synthase, which regulates the secretion of nitric oxide, a potent vasodilator. In animal ischemic models, US has been shown to improve hindlimb, myocardial, and cerebral perfusion. We performed a pilot trial of US therapy in the lower extremities of human subjects with intermittent claudication. METHODS: 10 subjects (5 male, 5 female, mean age 69.7 ± 10.3) with intermittent claudication were recruited. Both legs were placed in a specially designed boot with a water interface between US transducers and the legs. Subjects underwent pulsed US therapy at 250 kHz frequency for 30 min for three treatments a week for six weeks. Pre and post treatment ankle:brachial index (ABI), 6-min walk (6 MW), Walking Impairment Questionnaire (WIQ), and Short Form 36 (SF36) were performed. Pre and post-treatment results were compared with paired t-test. RESULTS: Six minute walking distance at baseline was 352 ± 70 m, after one treatment session 353 ± 70 m (p = 0.99), and at completion 372 ± 71 m (p = 0.015). There was a trend toward improved ABI after 6 weeks of treatment (0.53 ± 0.17 vs 0.64 ± 0.12, p = 0.083). After six weeks, significant improvements were noted in overall WIQ score (2.00 ± 1.48 vs 2.63 ± 1.38, p = 0.0001), WIQ (distance) 2.07 ± 1.54 vs 2.73 ± 1.42 (p = 0.036), and WIQ (stair) 2.00 ± 1.67 vs 2.62 ± 1.24, p = 0.034, with a trend in WIQ (speed), 1.89 ± 1.26 vs 2.46 ± 1.43, p = 0.069. In the SF-36, significant improvements were noted in the domains of physical functioning (44.0 ± 41.6 vs 50.5 ± 41.1, p = 0.009) and role limitations - physical (35.0 ± 48.3 vs 60.0 ± 49.6, p = 0.006) after six weeks. CONCLUSIONS: Therapeutic US is a potential noninvasive treatment for intermittent claudication. Pilot study patients noted significant improvements in 6 MW and WIQ results after 6 weeks of treatment. A nonsignificant improvement in ABI was noted. Further research will be needed to clarify optimal treatment frequency and duration.


Asunto(s)
Claudicación Intermitente/terapia , Terapia por Ultrasonido , Anciano , Índice Tobillo Braquial , Femenino , Humanos , Pierna/irrigación sanguínea , Masculino , Proyectos Piloto , Calidad de Vida , Encuestas y Cuestionarios , Caminata
5.
J Thromb Haemost ; 19(2): 502-512, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33205492

RESUMEN

BACKGROUND: In vitro studies with ultrasound (US) and microbubbles (MB) have reported that sono-thrombolysis can be achieved at high peak rarefactional acoustic pressure amplitudes (PRAPAs) using 0.25 and 1.05 MHz US frequencies. OBJECTIVE: The aim of the current study was to determine if these parameters work on an ex vivo physiological model of thrombosis. METHODS: A thrombogenic device was placed in an ex vivo chronic arteriovenous shunt in juvenile baboons. Platelet accumulation was measured by dynamic imaging of the device and the 10 cm thrombus tail with 111 In-labeled platelets. After 15 minutes of thrombus formation, treatment with either low-dose recombinant tissue plasminogen activator (rtPA) or low-dose rtPA + MB+US was performed for 20 minutes. Four US settings at 0.25% duty cycle were used: 0.25 MHz at PRAPAs of 1.20 and 2.20 MPa, and 1.05 MHz at 1.75 and 4.75 MPa. RESULTS: Platelet accumulation was not inhibited by low-dose rtPA or MB with US alone. Platelet accumulation was significantly reduced with 0.25 MHz US at 2.20 PRAPA (P < .001) and with 1.05 MHz at 1.75 MPa and 4.75 MPa (P < .05) when used with MB and low-dose rtPA. Although this approach prevented platelet accumulation it did not cause thrombolysis on the device. CONCLUSIONS: rtPA + MB + US (0.25 and 1.05 MHz) resulted in inhibition of platelet accumulation on the thrombogenic device when moderately high PRAPAs (≥1.75 MPa) were used. These results taken in context with lytic effects of US on myocardial microthrombi and direct effect on myocardial blood flow and function provide direction for the use of therapeutic US in acute coronary syndromes.


Asunto(s)
Trombosis , Terapia por Ultrasonido , Animales , Microburbujas , Primates , Terapia Trombolítica , Trombosis/terapia , Activador de Tejido Plasminógeno
6.
J Am Soc Echocardiogr ; 33(2): 234-246, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31812549

RESUMEN

BACKGROUND: Therapeutic ultrasound (TUS) has been used to lyse infarct-related coronary artery thrombus. There has been no study examining the effect of TUS specifically on myocardial microthromboemboli seen in acute myocardial infarction and acute coronary syndromes. The aim of this study was to test the hypothesis that TUS improves myocardial blood flow (MBF) and reduces infarct size (IS) in this situation by dissolving myocardial microthrombi. METHODS: An open-chest canine model of myocardial microthromboembolism was created by disrupting a thrombus in the left anterior descending coronary artery, and 1.05- and 0.25-MHz TUS (n = 7 each) delivered epicardially for 30 min was compared with control (n = 6). MBF and IS (as a percentage of left anterior descending coronary artery perfusion bed size) were measured 60 min after treatment. In addition, immunohistochemistry was performed to assess microthrombi, and histopathology was performed to define inflammation. RESULTS: Transmural, epicardial, and endocardial myocardial blood volume and MBF (measured using myocardial contrast echocardiography) and percentage wall thickening were significantly higher 60 min after receiving TUS compared with control. The ratio of IS to left anterior descending coronary artery perfusion bed size was significantly smaller (P = .03) in the 1.05-MHz TUS group (0.14 ± 0.04) compared with the control (0.31 ± 0.06, P = .04) and 0.25-MHz (0.36 ± 0.08) groups. MBF versus percentage wall thickening exhibited a linear relation (r = 0.65) in the control and 1.05-MHz TUS groups but not in the 0.25-MHz TUS group (r = 0.29). The presence of myocardial microemboli in vessels >10 µm in diameter was significantly reduced in the 1.05-MHz TUS group compared with the other two groups. The distribution and intensity of inflammation was higher in the 0.25-MHz TUS group compared with the other groups. CONCLUSIONS: TUS at 1.05 MHz is effective in restoring myocardial blood volume and MBF, thus reducing IS by clearing the microcirculation of microthrombi. IS reduction is not seen at 0.25 MHz, despite improvement in MBF, which may be related to the increased inflammation noted at this frequency. Because both acute myocardial infarction and acute coronary syndromes are associated with microthromboembolism, these results suggest that TUS could have a potential adjunctive role in the treatment of both conditions.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/fisiología , Trombosis Coronaria/prevención & control , Vasos Coronarios/fisiopatología , Microcirculación/fisiología , Infarto del Miocardio/terapia , Terapia por Ultrasonido/métodos , Animales , Trombosis Coronaria/complicaciones , Trombosis Coronaria/diagnóstico , Modelos Animales de Enfermedad , Progresión de la Enfermedad , Perros , Ecocardiografía/métodos , Masculino , Infarto del Miocardio/etiología , Infarto del Miocardio/fisiopatología , Resultado del Tratamiento
7.
J Am Soc Echocardiogr ; 32(9): 1151-1160, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31272838

RESUMEN

BACKGROUND: Therapeutic ultrasound can reduce infarct size in a model of coronary thrombosis even when sonothrombolysis is ineffective. The aim of this study was to test the hypothesis that ultrasound-induced cardioprotection is mediated by molecules released from the vascular endothelium that increase myocardial blood flow (MBF) and also have direct tissue-salvaging effects. METHODS: In vivo and in vitro experiments were performed using a 1.05-MHz transducer. For the in vivo experiments 10 control and 10 ultrasound-treated dogs undergoing occlusion of the left anterior descending coronary artery were studied. MBF was measured using myocardial contrast echocardiography. For the in vitro experiments, primary mouse cardiac endothelial cells were exposed to ultrasound at baseline or following oxygen-glucose deprivation and endothelial nitric oxide synthase phosphorylation as well as adenosine and the eicosanoids epoxyeicosatrienoic acids, dihydroxyeicosatrienoic acids, and hydroxyl-eicosatetraenoic acids were measured. RESULTS: In vivo, ultrasound treatment caused higher MBF (20 ± 10 vs 10 ± 8, P = .03) and higher wall thickening (3 ± 3% vs 1 ± 0.4%, P = .01) in the collateral-derived border zone compared with control. Epicardial MBF in the left anterior descending coronary artery bed also tended to be higher (17 ± 17 vs 5 ± 4, P = .05) in ultrasound-treated versus control animals; however, endocardial MBF in this region was similar to that in controls (13 ± 14 vs 14 ± 7). In vitro, phosphorylated endothelial nitric oxide synthase and adenosine increased (by 129 ± 11% and 286 ± 63%, respectively, P < .01) with ultrasound compared with unstimulated cells. Similar results were obtained with epoxyeicosatrienoic acids. After oxygen-glucose deprivation, phosphorylated endothelial nitric oxide synthase decreased and was restored with application of ultrasound. Similar changes were noted with epoxyeicosatrienoic acids. Cell viability decreased with oxygen-glucose deprivation and returned to near baseline with ultrasound. CONCLUSIONS: Ultrasound increases MBF in ischemic tissue in vivo. This effect is likely mediated by the release of a plethora of coronary vasodilators during ultrasound treatment that also have direct tissue-salvaging effects. Therapeutic ultrasound, therefore, has potential for treatment of acute and chronic myocardial ischemia independent of its effect on thrombolysis.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/fisiología , Vasos Coronarios/fisiopatología , Células Endoteliales/patología , Isquemia Miocárdica/terapia , Miocardio/patología , Terapia por Ultrasonido/métodos , Animales , Vasos Coronarios/patología , Modelos Animales de Enfermedad , Perros , Masculino , Isquemia Miocárdica/patología , Isquemia Miocárdica/fisiopatología
8.
J Am Soc Echocardiogr ; 30(5): 503-510.e1, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28238588

RESUMEN

BACKGROUND: Contrast-enhanced ultrasound (CEU) limb perfusion imaging is a promising approach for evaluating peripheral artery disease (PAD). However, low signal enhancement in skeletal muscle has necessitated high-power intermittent imaging algorithms, which are not clinically feasible. We hypothesized that CEU using a combination of intermediate power and a contrast agent resistant to inertial cavitation would allow real-time limb stress perfusion imaging. METHODS: In normal volunteers, CEU of the calf skeletal muscle was performed on separate days with Sonazoid, Optison, or Definity. Progressive reduction in the ultrasound pulsing interval was used to assess the balance between signal enhancement and agent destruction at escalating mechanical indices (MI, 0.1-0.4). Real-time perfusion imaging at MI 0.1-0.4 using postdestructive replenishment kinetics was performed at rest and during 25 W plantar flexion contractile exercise. RESULTS: For Optison, limb perfusion imaging was unreliable at rest due to very low signal enhancement generated at all MIs and was possible during exercise-induced hyperemia only at MI 0.1 due to agent destruction at higher MIs. For Definity, signal intensity progressively increased with MI but was offset by microbubble destruction, which resulted in modest signal enhancement during CEU perfusion imaging and distortion of replenishment curves at MI ≥ 0.2. For Sonazoid, there strong signal enhancement at MI ≥ 0.2, with little destruction detected only at MI 0.4. Accordingly, high signal intensity and nondistorted perfusion imaging was possible at MI 0.2-0.3 and detected an 8.0- ± 5.7-fold flow reserve. CONCLUSIONS: Rest-stress limb perfusion imaging in humans with real-time CEU, which requires only seconds to perform, is possible using microbubbles with viscoelastic properties that produce strong nonlinear signal generation without destruction at intermediate acoustic pressures.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Prueba de Esfuerzo/métodos , Fluorocarburos , Pierna/fisiología , Músculo Esquelético/fisiología , Imagen de Perfusión/métodos , Ultrasonografía/métodos , Adulto , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Pierna/irrigación sanguínea , Masculino , Microburbujas , Músculo Esquelético/irrigación sanguínea , Reproducibilidad de los Resultados , Descanso , Sensibilidad y Especificidad
9.
Circulation ; 135(13): 1240-1252, 2017 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-28174191

RESUMEN

BACKGROUND: Augmentation of tissue blood flow by therapeutic ultrasound is thought to rely on convective shear. Microbubble contrast agents that undergo ultrasound-mediated cavitation markedly amplify these effects. We hypothesized that purinergic signaling is responsible for shear-dependent increases in muscle perfusion during therapeutic cavitation. METHODS: Unilateral exposure of the proximal hindlimb of mice (with or without ischemia produced by iliac ligation) to therapeutic ultrasound (1.3 MHz, mechanical index 1.3) was performed for 10 minutes after intravenous injection of 2×108 lipid microbubbles. Microvascular perfusion was evaluated by low-power contrast ultrasound perfusion imaging. In vivo muscle ATP release and in vitro ATP release from endothelial cells or erythrocytes were assessed by a luciferin-luciferase assay. Purinergic signaling pathways were assessed by studying interventions that (1) accelerated ATP degradation; (2) inhibited P2Y receptors, adenosine receptors, or KATP channels; or (3) inhibited downstream signaling pathways involving endothelial nitric oxide synthase or prostanoid production (indomethacin). Augmentation in muscle perfusion by ultrasound cavitation was assessed in a proof-of-concept clinical trial in 12 subjects with stable sickle cell disease. RESULTS: Therapeutic ultrasound cavitation increased muscle perfusion by 7-fold in normal mice, reversed tissue ischemia for up to 24 hours in the murine model of peripheral artery disease, and doubled muscle perfusion in patients with sickle cell disease. Augmentation in flow extended well beyond the region of ultrasound exposure. Ultrasound cavitation produced an ≈40-fold focal and sustained increase in ATP, the source of which included both endothelial cells and erythrocytes. Inhibitory studies indicated that ATP was a critical mediator of flow augmentation that acts primarily through either P2Y receptors or adenosine produced by ectonucleotidase activity. Combined indomethacin and inhibition of endothelial nitric oxide synthase abolished the effects of therapeutic ultrasound, indicating downstream signaling through both nitric oxide and prostaglandins. CONCLUSIONS: Therapeutic ultrasound using microbubble cavitation to increase muscle perfusion relies on shear-dependent increases in ATP, which can act through a diverse portfolio of purinergic signaling pathways. These events can reverse hindlimb ischemia in mice for >24 hours and increase muscle blood flow in patients with sickle cell disease. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT01566890.


Asunto(s)
Adenosina Trifosfato/metabolismo , Músculo Esquelético/irrigación sanguínea , Purinérgicos/metabolismo , Ultrasonografía/métodos , Animales , Hemodinámica , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Microburbujas , Transducción de Señal
10.
Am J Physiol Heart Circ Physiol ; 309(4): H583-91, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26092990

RESUMEN

Stroke outcome is improved by therapeutic ultrasound. This benefit is presumed to be principally from ultrasound-mediated thrombolysis. We hypothesized that the therapeutic benefit of ultrasound in stroke may, in part, be mediated by the release of beneficial vasoactive substances. Accordingly, we investigated the effect of ultrasound on levels of cytochrome P-450, lipoxygenase, and cyclooxygenase metabolites of arachidonic acid as well as adenosine release and endothelial nitric oxide synthase (eNOS) phosphorylation in primary brain endothelial cells in vitro. Brain endothelial cells were exposed to 1.05-MHz ultrasound at peak rarefactional acoustic pressure amplitudes of 0.35, 0.55, 0.90, and 1.30 MPa. Epoxyeicosatrienoic acids (EETs), hydroxyeicosatetraenoic acids (HETEs), PGE2, adenosine, nitrate/nitrite, and eNOS phosphorylation were measured after ultrasound exposure. Levels of 8,9-EET, 11,12-EET, and 14,15-EET increased by 230 ± 28%, 240 ± 30%, and 246 ± 31% (P < 0.05), respectively, whereas 5-HETE and 15-HETE levels were reduced to 24 ± 14% and 10 ± 3% (P < 0.05), respectively, compared with cells not exposed to ultrasound. PGE2 levels were reduced to 56 ± 14% of control. Adenosine increased more than sixfold after ultrasound exposure compared with unstimulated cells (1.36 ± 0.22 vs. 0.37 ± 0.10 ng/ml, P < 0.05), nitrate/nitrite was below levels of quantification, and eNOS phosphorylation was not altered significantly. Our results suggest that ultrasound may enhance tissue perfusion during stroke by augmenting the generation of vasodilator compounds and inhibiting that of vasoconstrictors. Such regulation supports a beneficial role for therapeutic ultrasound in stroke independent of its effect on the occlusive thrombus.


Asunto(s)
Encéfalo/citología , Células Endoteliales/efectos de la radiación , Endotelio Vascular/efectos de la radiación , Sonido , Adenosina/metabolismo , Animales , Encéfalo/irrigación sanguínea , Encéfalo/efectos de la radiación , Células Cultivadas , Sistema Enzimático del Citocromo P-450/metabolismo , Dinoprostona/metabolismo , Células Endoteliales/metabolismo , Endotelio Vascular/metabolismo , Ácidos Hidroxieicosatetraenoicos/metabolismo , Lipooxigenasa/metabolismo , Masculino , Ratones , Ratones Endogámicos C57BL , Óxido Nítrico Sintasa de Tipo III/metabolismo , Prostaglandina-Endoperóxido Sintasas/metabolismo , Vasodilatación
11.
Thromb Haemost ; 113(6): 1357-69, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25809056

RESUMEN

Ultrasound and microbubble (MB) contrast agents accelerate clot lysis, yet clinical trials have been performed without defining optimal acoustic conditions. Our aim was to assess the effect of acoustic pressure and frequency on the extent and spatial location of clot lysis. Clots from porcine blood were created with a 2-mm central lumen for infusion of lipid-shelled perfluorocarbon MBs (1×10(7) ml(-1)) or saline. Therapeutic ultrasound at 0.04, 0.25, 1.05, or 2.00 MHz was delivered at a wide range of peak rarefactional acoustic pressure amplitudes (PRAPAs). Ultrasound was administered over 20 minutes grouped on-off cycles to allow replenishment of MBs. The region of lysis was quantified using contrast-enhanced ultrasound imaging. In the absence of MBs, sonothrombolysis did not occur at any frequency. Sonothrombolysis was also absent in the presence of MBs despite their destruction at 0.04 and 2.00 MHz. It occurred at 0.25 and 1.05 MHz in the presence of MBs for PRAPAs > 1.2 MPa and increased with PRAPA. At 0.25 MHz the clot lysis was located in the far wall. At 1.05 MHz, however, there was a transition from far to near wall as PRAPA was increased. The area of clot lysis measured by ultrasound imaging correlated with that by micro-CT and quantification of debris in the effluent. In conclusion, sonothrombolysis with MBs was most efficient at 0.25 MHz. The spatial location of sonothrombolysis varies with pressure and frequency indicating that the geometric relation between therapeutic probe and vascular thrombosis is an important variable for successful lysis clinically.


Asunto(s)
Medios de Contraste , Trombolisis Mecánica/métodos , Microburbujas , Trombosis/terapia , Terapia por Ultrasonido/métodos , Animales , Diseño de Equipo , Masculino , Trombolisis Mecánica/instrumentación , Presión , Sonido , Porcinos , Trombosis/sangre , Trombosis/diagnóstico por imagen , Factores de Tiempo , Transductores , Terapia por Ultrasonido/instrumentación , Ultrasonografía , Microtomografía por Rayos X
12.
Ultrasound Med Biol ; 34(10): 1578-89, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18456391

RESUMEN

Adjuvant therapies that lower the thrombolytic dose or increase its efficacy would represent a significant breakthrough in the treatment of patients with ischemic stroke. The objective of this study was to perform intracranial measurements of the acoustic pressure field generated by 0.12, 1.03 and 2.00-MHz ultrasound transducers to identify optimal ultrasound parameters that would maximize penetration and minimize aberration of the beam. To achieve this goal, in vitro experiments were conducted on five human skull specimens. In a water-filled tank, two unfocused transducers (0.12 and 1.03 MHz) and one focused transducer (2.00 MHz) were consecutively placed near the right temporal bone of each skull. A hydrophone, mounted on a micropositioning system, was moved to an estimated location of the middle cerebral artery (MCA) origin, and measurements of the surrounding acoustic pressure field were performed. For each measurement, the distance from the position of maximum acoustic pressure to the estimated origin of the MCA inside the skulls was quantified. The -3 dB depth-of-field and beamwidth in the skull were also investigated as a function of the three frequencies. Results show that the transducer alignment relative to the skull is a significant determinant of the detailed behavior of the acoustic field inside the skull. For optimal penetration, insonation normal to the temporal bone was needed. The shape of the 0.12-MHz intracranial beam was more distorted than those at 1.03 and 2.00 MHz because of the large aperture and beamwidth. However, lower ultrasound pressure reduction was observed at 0.12 MHz (22.5%). At 1.03 and 2.00 MHz, two skulls had an insufficient temporal bone window and attenuated the beam severely (up to 96.6% pressure reduction). For all frequencies, constructive and destructive interference patterns were seen near the contralateral skull wall at various elevations. The 0.12-MHz ultrasound beam depth-of-field was affected the most when passing through the temporal bone and showed a decrease in size of more than 55% on average. The speed of sound in the temporal bone of each skull was estimated at 1.03 MHz and demonstrated a large range (1752.1 to 3285.3 m/s). Attenuation coefficients at 1.03 and 2.00 MHz were also derived for each of the five skull specimens. This work provides needed information on ultrasound beam shapes inside the human skull, which is a necessary first step for the development of an optimal transcranial ultrasound-enhanced thrombolysis device.


Asunto(s)
Arteria Cerebral Media/diagnóstico por imagen , Hueso Temporal/diagnóstico por imagen , Acústica , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Mapeo Encefálico/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cráneo/diagnóstico por imagen , Hueso Temporal/anatomía & histología , Tomografía Computarizada por Rayos X , Transductores , Ultrasonografía Doppler Transcraneal/instrumentación , Ultrasonografía Doppler Transcraneal/métodos
13.
Ultrasound Med Biol ; 34(9): 1421-33, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18378380

RESUMEN

Ultrasound has been shown previously to act synergistically with a thrombolytic agent, such as recombinant tissue plasminogen activator (rt-PA) to accelerate thrombolysis. In this in vitro study, a commercial contrast agent, Definity, was used to promote and sustain the nucleation of cavitation during pulsed ultrasound exposure at 120 kHz. Ultraharmonic signals, broadband emissions and harmonics of the fundamental were measured acoustically by using a focused hydrophone as a passive cavitation detector and used to quantify the level of cavitation activity. Human whole blood clots suspended in human plasma were exposed to a combination of rt-PA, Definity and ultrasound at a range of ultrasound peak-to-peak pressure amplitudes, which were selected to expose clots to various degrees of cavitation activity. Thrombolytic efficacy was determined by measuring clot mass loss before and after the treatment and correlated with the degree of cavitation activity. The penetration depth of rt-PA and plasminogen was also evaluated in the presence of cavitating microbubbles using a dual-antibody fluorescence imaging technique. The largest mass loss (26.2%) was observed for clots treated with 120-kHz ultrasound (0.32-MPa peak-to-peak pressure amplitude), rt-PA and stable cavitation nucleated by Definity. A significant correlation was observed between mass loss and ultraharmonic signals (r = 0.85, p < 0.0001, n = 24). The largest mean penetration depth of rt-PA (222 microm) and plasminogen (241 microm) was observed in the presence of stable cavitation activity. Stable cavitation activity plays an important role in enhancement of thrombolysis and can be monitored to evaluate the efficacy of thrombolytic treatment.


Asunto(s)
Medios de Contraste/administración & dosificación , Fluorocarburos/administración & dosificación , Terapia Trombolítica/métodos , Trombosis/tratamiento farmacológico , Terapia por Ultrasonido/métodos , Terapia Combinada , Fibrinolíticos/administración & dosificación , Fibrinolíticos/uso terapéutico , Humanos , Microscopía Fluorescente , Microesferas , Proteínas Recombinantes/uso terapéutico , Procesamiento de Señales Asistido por Computador , Trombosis/diagnóstico por imagen , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Tejido Plasminógeno/uso terapéutico , Ultrasonografía
14.
Artículo en Inglés | MEDLINE | ID: mdl-16471439

RESUMEN

Determining the rupture pressure threshold of ultrasound contrast agent microbubbles has significant applications for contrast imaging, development of therapeutic agents, and evaluation of potential bioeffects. Using a passive cavitation detector, this work evaluates rupture based on acoustic emissions from single, encapsulated, gas-filled microbubbles. Sinusoidal ultrasound pulses were transmitted into weak solutions of Optison at different center frequencies (0.9, 2.8, and 4.6 MHz), pulse durations (three, five, and seven cycles of the center frequencies), and peak rarefactional pressures (0.07 to 5.39 MPa). Pulse repetition frequency was 10 Hz. Signals detected with a 13-MHz, center-frequency transducer revealed postexcitation acoustic emissions (between 1 and 5 micros after excitation) with broadband spectral content. The observed acoustic emissions were consistent with the acoustic signature that would be anticipated from inertial collapse followed by "rebounds" when a microbubble ruptures and thus generates daughter/free bubbles that grow and collapse. The peak rarefactional pressure threshold for detection of these emissions increased with frequency (e.g., 0.53, 0.87, and 0.99 MPa for 0.9, 2.8, and 4.6 MHz, respectively; five-cycle pulse duration) and decreased with pulse duration. The emissions identified in this work were separated from the excitation in time and spectral content, and provide a novel determination of microbubble shell rupture.


Asunto(s)
Albúminas/análisis , Medios de Contraste , Fluorocarburos/análisis , Interpretación de Imagen Asistida por Computador/métodos , Microburbujas , Sonicación , Ultrasonografía/métodos , Albúminas/efectos de la radiación , Fluorocarburos/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...