Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med Dosim ; 30(1): 1-7, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15749004

RESUMEN

The purpose of this paper was to assess the effect of setup uncertainty on dosimetry of prostate, seminal vesicles, bladder, rectum, and colon in prostate cancer patients treated with Peacock intensity-modulated radiation therapy (IMRT). Ten patients underwent computed tomography (CT) scans using the "prostate box" for external, and an "endorectal balloon" for target immobilization devices, and treatment plans were generated (T1). A maximum of +/-5-mm setup error was chosen to model dosimetric effects. Isodose lines from the T1 treatment plan were then superimposed on each patient's CT anatomy shifted by 5 mm toward the cephalad and caudal direction, generating 2 more dosimetric plans (H1 and H2, respectively). Average mean doses ranged from 74.5 to 74.92 Gy for prostate and 73.65 to 74.94 Gy for seminal vesicles. Average percent target volume below 70 Gy increased significantly for seminal vesicles, from 0.53% to 6.26%, but minimally for prostate, from 2.08% to 4.4%. Dose statistics adhered to prescription limits for normal tissues. Setup uncertainty had minimum impact on target dose escalation and normal tissue dosing. The impact of target dose inhomogeneity is currently evaluated in clinical studies.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Colon/diagnóstico por imagen , Colon/efectos de la radiación , Humanos , Inmovilización , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Dosificación Radioterapéutica , Recto/diagnóstico por imagen , Recto/efectos de la radiación , Vesículas Seminales/diagnóstico por imagen , Vesículas Seminales/efectos de la radiación , Tomografía Computarizada por Rayos X , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/efectos de la radiación
2.
Int J Radiat Oncol Biol Phys ; 56(1): 136-44, 2003 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-12694832

RESUMEN

PURPOSE: To evaluate the predictors of xerostomia in the treatment of head-and-neck cancers treated with intensity-modulated radiation therapy (IMRT), using the simultaneous modulated accelerated radiation therapy (SMART) boost technique. Dosimetric parameters of the parotid glands are correlated to subjective salivary gland function. MATERIALS AND METHODS: Between January 1996 and June 2000, 30 patients with at least 6 months follow-up were evaluated for subjective xerostomia after being treated definitively for head-and-neck cancer with the SMART boost technique. Threshold limits for the ipsilateral and contralateral parotid glands were 35 Gy and 25 Gy, respectively. Dosimetric parameters to the parotid glands were evaluated. The median follow-up time was 38.5 months (mean 39.9 months). The results of the dosimetric parameters and questionnaire were statistically correlated. RESULTS: Xerostomia was assessed with a 10-question subjective salivary gland function questionnaire. The salivary gland function questionnaire (questions 1, 2, 3, 4, 6, and 9) correlated significantly with the dosimetric parameters (mean and maximum doses and volume and percent above tolerance) of the parotid glands. These questions related to overall comfort, eating, and abnormal taste. Questions related to thirst, difficulty with speech or sleep, and the need to carry water daily did not correlate statistically with the dosimetric parameters of the parotid glands. CONCLUSIONS: Questions regarding overall comfort, eating, and abnormal taste correlated significantly with the dosimetric parameters of the parotid glands. Questions related to thirst, difficulty with speech or sleep, and the need to carry water daily did not correlate statistically with the dosimetric parameters of the parotid glands. Dosimetric sparing of the parotid glands improved subjective xerostomia. IMRT in the treatment of head-and-neck cancer can be exploited to preserve the parotid glands and decrease xerostomia. This is feasible even with an accelerated treatment regimen like the SMART boost. More patients need to be evaluated using IMRT to identify relevant dosimetric parameters.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Glándula Parótida/efectos de la radiación , Traumatismos por Radiación/etiología , Radiometría , Radioterapia Conformacional/efectos adversos , Xerostomía/etiología , Adulto , Anciano , Trastornos de Deglución/etiología , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Disgeusia/etiología , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Masculino , Dosis Máxima Tolerada , Persona de Mediana Edad , Glándula Parótida/lesiones , Aceptación de la Atención de Salud , Planificación de la Radioterapia Asistida por Computador , Radioterapia Conformacional/instrumentación , Radioterapia Conformacional/métodos , Estudios Retrospectivos , Salivación/efectos de la radiación , Trastornos del Sueño-Vigilia/etiología , Trastornos del Habla/etiología , Encuestas y Cuestionarios , Sed , Tomografía Computarizada por Rayos X
3.
Semin Oncol ; 29(6 Suppl 19): 71-9, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12577249

RESUMEN

The treatment of head and neck cancer has evolved from conventional fields encompassing large volumes of normal tissue to focused treatment aimed at conforming the dose around the target while avoiding normal tissue. Intensity modulated radiation therapy has changed the way radiation oncologists think about head and neck cancer. Using the concepts of conformal treatment and avoidance, the therapeutic ratio can be improved and technology exploited to the patients' advantage. This is particularly evident with head and neck irradiation, where a common side effect is xerostomia. By decreasing xerostomia through conformal avoidance of the parotid glands, we can improve patient satisfaction and quality of life. In this study, xerostomia is assessed through a subjective salivary gland function questionnaire. This article examines the use of intensity modulated radiation therapy in the treatment of head and neck cancer to decrease xerostomia. The purpose of this article is to evaluate the significance of parotid gland dosimetry in relation to subjective salivary gland function.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Traumatismos por Radiación/prevención & control , Radioterapia Conformacional , Xerostomía/prevención & control , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Glándula Parótida , Calidad de Vida , Traumatismos por Radiación/diagnóstico , Dosificación Radioterapéutica , Encuestas y Cuestionarios , Xerostomía/diagnóstico , Xerostomía/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...