Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Innov Card Rhythm Manag ; 14(1): 5322-5324, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37213885

RESUMEN

Left ventricular lead positioning is technically demanding in cardiac resynchronization therapy (CRT) device implantation, especially in patients with complex cardiac venous anatomies. We report a case in which retrograde snaring was employed to successfully deliver the left ventricular lead through a persistent left superior vena cava for CRT implantation.

2.
J Interv Cardiol ; 2022: 6587036, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35847236

RESUMEN

Background: Re-operative mitral valve (MV) replacement is a high-risk procedure, therefore, transcatheter MV replacement (TMVR) is a promising therapeutic option. Aim: In this study, we aimed to evaluate the feasibility and safety of TMVR in patients with high surgical risk with degenerated mitral bioprostheses (TMViV), failed surgical rings (TMViR), and mitral annular calcification (TMViMAC). Methods: This is a retrospective cohort study that enrolled patients with high surgical risk who underwent TMVR from February 2017 to September 2020. The TMVR procedure was performed using Edwards SAPIEN-3 valves through the transseptal approach. Results: Sixty-four patients aged 62.7 ± 16.1 years with an STS score of 9.2 ± 3.7% underwent TMVR [35 (55%) TMViV, 16 (25%) TMViR, and 13 (20%) TMViMAC]. Mitral stenosis was more frequent in TMViV, mitral regurgitation was more frequent in TMViR, and combined mitral stenosis and regurgitation were more frequent in TMViMAC (P < 0.05). The MV gradient was 14.3 ± 5.3 mmHg and the MV area was 1.5±0.6 cm2. The 29 mm valve was frequently used in TMViV and TMViMAC, while the 23 mm valve was frequently used in TMViR (P=0.003 ∗ ). The procedural and fluoroscopy times were 58.7 ± 8.9 and 41.1 ± 8.2 minutes, respectively. Technical success was reported in 62 (98.4%) patients; 1 TMViR patient experienced valve embolization and salvage surgery, and 1 TMViMAC patient experienced slight valve malposition. At 3 months, 2 (3.1%) patients showed valve thrombosis (treated with anticoagulation), and 1 (1.6%) patient developed a paravalvular leak (underwent surgical MV replacement). At 6 months, 3 (4.7%) patients showed valve degeneration (underwent surgical MV replacement). Throughout follow-up, no patient exhibited mortality. Conclusions: TMVR is a feasible and safe approach in patients with high surgical risk. TMViV and TMViR are reasonable as the first treatment approaches, and TMViMAC seems encouraging.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
3.
Pediatr Cardiol ; 43(2): 308-323, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34495353

RESUMEN

Residual or iatrogenic ventricular septal defects (VSDs) may result in significant hemodynamic effect. This study aimed to review our center experience in transcatheter closure of post-surgical and post-intervention residual and iatrogenic VSDs and to report on their 12-month long-term outcome. All patients who underwent transcatheter closure of residual/iatrogenic VSDs after surgical or transcatheter CHD interventions between January-2015 and January-2020 were included. Patients' medical records were reviewed and analyzed. Twenty-three patients with a mean age of 14.3 ± 8.8 years were included. The VSD was residual in 18 (78.3%) patients and iatrogenic in 5 (21.7%) patients, post-operative in 19 (82.6%) patients and post-transcatheter in 4 (17.4%) patients. The VSD site was peri-membranous in 9 (39.1%) patients, high-muscular in 6 (26.1%) patients, mid-muscular in 4 (17.4%) patients, and Gerbode shunt in 4 (17.4%) patients. The QP/QS ratio was 2.5 ± 0.7, and the VSD diameter was 6.1 ± 2.1 mm. Most, 16 (71.43%) patients underwent antegrade device deployment, and 7 (28.57%) patients underwent retrograde transaortic device deployment with 3 (13.0%) patients required two devices. Amplatzer™ Muscular VSD devices were used in 16 (69.6%) patients, Amplatzer™ Duct occlude-I devices were used in 4 (17.4%) patients, and Amplatzer™ Duct Occluder-II devices were used in 3 (13.0%) patients with a mean device size of 8.8 ± 2.8 mm. Procedural and fluoroscopy times were 55.1 ± 16.2 and 16.3 ± 4.0 min respectively. During follow-up (23.3 ± 15.9 months), no patient required re-intervention or exhibited mortality. Transcatheter closure of post-operative and post-intervention residual/iatrogenic VSDs represents a safe, feasible, and effective therapeutic approach.


Asunto(s)
Defectos del Tabique Interventricular , Dispositivo Oclusor Septal , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/cirugía , Humanos , Enfermedad Iatrogénica , Estudios Retrospectivos , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento , Adulto Joven
4.
Struct Heart ; 6(3): 100043, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37274546

RESUMEN

Background: In specific patients with severe mitral regurgitation (MR), mitral valve (MV) pathology is unique and requires creative transcatheter repair techniques. This study aimed to evaluate the feasibility and safety of a new transcatheter MV repair technique, using occluder devices in symptomatic high-surgical-risk patients with severe MR, either due to MV leaflet (MVL) perforations or due to post-clips residual MR, and to report on their 6-month outcomes. Methods: The study enrolled all high-risk patients with severe MR due to MVL perforations and post-clips residual MR who underwent transcatheter MV repair using occluder devices, from November 2016 to August 2019. Results: The study enrolled 16 patients; 9 (56.25%) with MVL perforations and 7 (43.75%) with post-MitraClip (Abbott Laboratories, Abbott Park, Illinois) residual MR, with a mean age of 55.75 ± 16.69 years. Mean perforation/jet diameters were 5.75 ± 1.67 and 6.5 ± 1.93 mm, and the mean 3D-vena contracta area was 0.54 ± 0.14 cm2. Perforations were crossed retrograde (transaortic in 7 [43.75%] patients and transapical in 2 [12.5%] patients), and post-MitraClip devices residual jets were crossed antegrade (transvenous/transseptal). Six (37.5%) patients required arteriovenous loop formation for device deployment, that was antegrade transvenous/transseptal in 13 (81.25%) patients and retrograde transapical in 3 (18.75%) patients. Devices used were Amplatzer-ASO in 10 (62.5%) patients and Amplatzer-VP-II in 6 (37.5%) patients. Mean procedural and fluoroscopy times were 55.13 ± 16.24 and 16.25 ± 4.03 â€‹minutes, respectively. Patients passed successfully, without MV gradient change or device-related complications. Conclusions: Transcatheter MV repair of MVL perforations/post-clips residual MR is a new, feasible, and safe technique for high-surgical-risk patients.

5.
Vasc Health Risk Manag ; 17: 471-480, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34408425

RESUMEN

BACKGROUND: Vitamin D deficiency is considered an emerging health problem that affects at least one billion patients worldwide. Calcitriol 1,25(OH)2D3 has several systemic effects, including anti-inflammatory, anti-thrombotic and anti-atherosclerotic impacts that explain its cardioprotective effects. The precise association between vitamin D and its metabolites and the value of supplements in acute coronary syndrome (ACS) is still controversial. This study aims to search the association between vitamin D2, D3, and metabolites and ACS in patients undergoing coronary angiography. MATERIALS AND METHODS: This was a case-control study on 73 consecutive adult patients with ACS undergoing coronary angiography compared to 50 controls without coronary artery disease and matched for age and sex from June 2019 till July 2019. Echocardiography and coronary angiography were done for all cases. Plasma vitamin D and its metabolites were measured at admission for all participants along with chemistry profiles. RESULTS: Vitamin D and its metabolites were statistically significantly lower in ACS patients than the controls. Multivariate regression analysis revealed that low levels of 25-hydroxyvitamin D (25(OH)D) and 1,25-dihydroxyvitamin D (1,25(OH)2D) significantly predicted ACS occurrence; the other significant predictors were high systolic blood pressure (BP), high total cholesterol, and low high-density lipoprotein-cholesterol. Interestingly, vitamin D2 and D3 did not significantly predict ACS (p>0.05). We did not find a statistically significant association between the number of affected coronary vessels and vitamin D metabolites. Moreover, there was no statistically significant correlation between vitamin D and its metabolites and left ventricular ejection fraction measured by echocardiography. CONCLUSION: There was a strong association between vitamin D and all its metabolites with ACS. Significantly, low 25(OH)D and 1,25(OH)2D predicted ACS, but vitamin D2 and D3 did not. Large randomized controlled trials are needed to verify the beneficial values of vitamin D supplementation in ACS patients.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Deficiencia de Vitamina D/epidemiología , Vitamina D , Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Colesterol , Enfermedad de la Arteria Coronaria/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular Izquierda/fisiología , Vitamina D/administración & dosificación , Vitamina D/análogos & derivados , Vitamina D/sangre , Deficiencia de Vitamina D/sangre
6.
Eur Heart J Case Rep ; 4(4): 1-5, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32974453

RESUMEN

BACKGROUND: Severe mitral regurgitation (MR) through the body of the anterior mitral leaflet (AML) is rare. The cause either iatrogenic during open-heart surgery or due to infective endocarditis. We present a case where a successful percutaneous closure of the AML perforation was an alternative to surgery. CASE SUMMARY: A 60-year-old male presented with shortness of breath (SOB) class III of 12 months duration. He underwent coronary artery bypass surgery with four grafts plus mitral valve (MV) repair 20 months ago. Transthoracic echocardiogram (TTE) and transoesophageal echocardiogram (TOE) revealed severe MR through the body of AML at A3. The percutaneous closure plan was to cross the AML perforation from the left ventricular side. The venacontracta of the perforation was 6 mm, an amplatzer septal occluder device 6 mm considered appropriate for closure of this hole. A snare catheter snared the wire and exteriorized creating arteriovenous loop. Amplatzer septal occluder 6 mm loaded to the delivery system till larger disc (left-sided) opened safely and freely below the MV apparatus. Once the left ventricular side disc opposed the ventricular surface of AML, the waist and left atrial disc gently released. The patient discharged in the next day. After 6 months, the patient had no more SOB, he returned to his daily activity. Follow-up TTE showed no MR, the closure device was stable in place. DISCUSSION: We added a successful case of transcatheter AML perforation to the literature. The role of TOE is crucial in diagnosis and procedure guidance.

7.
Turk Kardiyol Dern Ars ; 48(4): 443-446, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32519986

RESUMEN

Leadless pacemakers provide a potential alternative to conventional transvenous pacemakers for patients undergoing high-risk transcatheter valve replacement procedures. This is a description of a successful leadless pacemaker implantation in a 51-year-old woman who developed profound bradycardia following a transcatheter aortic valve replacement and mitral valve-in-valve procedure.


Asunto(s)
Bradicardia/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Marcapaso Artificial/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Cuidados Posteriores , Bradicardia/diagnóstico , Bradicardia/etiología , Bradicardia/fisiopatología , Ecocardiografía/métodos , Electrocardiografía/métodos , Diseño de Equipo/tendencias , Femenino , Humanos , Persona de Mediana Edad , Válvula Mitral/cirugía , Flebografía/métodos , Resultado del Tratamiento
9.
Indian Pacing Electrophysiol J ; 19(1): 27-29, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30367925

RESUMEN

Venous revascularization is an approach used in patients with total venous occlusion requiring venous access for cardiac device lead placement. Several percutaneous approaches to venous revascularization have been proposed. For the first time, we describe the case of a 69-year-old male with total venous occlusion who was successfully revascularized using a 'diathermy' technique.

10.
J Electrocardiol ; 51(6): 963-965, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30497756

RESUMEN

Brugada phenocopies (BrP) are clinical entities that are characterized by ECG patterns identical to those of Brugada syndrome, but are the result of various clinical conditions. We describe the case of a 41-year-old male who exhibited BrP due to a left ventricular aneurysm in the context of chronic coronary artery disease.


Asunto(s)
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Ecocardiografía , Electrocardiografía , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Fenotipo
11.
J Saudi Heart Assoc ; 30(3): 268-270, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29989026

RESUMEN

The recommended anticoagulation regimen for continuous-flow left ventricular assist device (LVAD) systems is warfarin and aspirin with a targeted international normalized ratio (INR) of 2.0-3.0. Our patient is a 58-year-old male who underwent surgical HeartMate III continuous-flow LVAD implantation 3 months ago outside the country. The patient mistakenly stopped taking warfarin for 1 month prior to presenting to our center for a routine visit. Luckily, the patient was doing very well without any complication despite the fact that his INR was 1.0.

12.
J Saudi Heart Assoc ; 30(3): 271-275, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29989068

RESUMEN

To the best of our knowledge, there have not been any reports of total transcatheter approach including stenting of severe coarctation of the aorta (CoA), transcatheter aortic valve replacement (TAVR) for concomitant severe aortic valve stenosis, and percutaneous coronary intervention (PCI) to treat significant coronary artery disease in a single patient. We report a 70-year-old female, who presented with uncontrolled hypertension and acute decompensated heart failure (ADHF) and was found to have severe CoA, severe bicuspid aortic valve (BAV) stenosis, and significant proximal left anterior descending (LAD) coronary artery disease. In a multidisciplinary heart team meeting, we decided to perform an endovascular repair of both cardiac and vascular pathologies using a two-stage approach due to the significant comorbidities; mainly uncontrolled hypertension, type 2 diabetes mellitus, chronic obstructive pulmonary disease, and severe calcifications of the ascending aorta. The procedures were successfully performed and the patient was asymptomatic 30 months later at follow-up and was without any significant gradients across the coarctation or the aortic valve.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...