1.
Sci Adv ; 9(33): eadh3484, 2023 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-37595048

RESUMEN

Understanding diffusion in microstructures plays a crucial role in many scientific fields, including neuroscience, medicine, or energy research. While magnetic resonance (MR) methods are the gold standard for diffusion measurements, spatial encoding in MR imaging has limitations. Here, we introduce nitrogen-vacancy (NV) center-based nuclear MR (NMR) spectroscopy as a powerful tool to probe diffusion within microscopic sample volumes. We have developed an experimental scheme that combines pulsed gradient spin echo (PGSE) with optically detected NV-NMR spectroscopy, allowing local quantification of molecular diffusion and flow. We demonstrate correlated optical imaging with spatially resolved PGSE NV-NMR experiments probing anisotropic water diffusion within an individual model microstructure. Our optically detected PGSE NV-NMR technique opens up prospects for extending the current capabilities of investigating diffusion processes with the future potential of probing single cells, tissue microstructures, or ion mobility in thin film materials for battery applications.

2.
MAGMA ; 36(6): 921-932, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37578612

RESUMEN

INTRODUCTION: Diffusion weighting in optically detected magnetic resonance experiments involving diamond nitrogen-vacancy (NV) centers can provide valuable microstructural information. Bi-planar gradient coils employed for diffusion weighting afford excellent spatial access, essential for integrating the NV-NMR components. Nevertheless, owing to the polar tilt of roughly [Formula: see text] of the diamond NV center, the primary magnetic field direction must be taken into account accordingly. METHODS: To determine the most effective bi-planar gradient coil configurations, we conducted an investigation into the impact of various factors, including the square side length, surface separation, and surface orientation. This was accomplished by generating over 500 bi-planar surface configurations using automated methods. RESULTS: We successfully generated and evaluated coil layouts in terms of sensitivity and field accuracy. Interestingly, inclined bi-planar orientations close to the NV-NMR setup's requirement, showed higher sensitivity for the transverse gradient channels than horizontal or vertical orientations. We fabricated a suitable solution as a three-channel bi-planar double-layered PCB system and experimentally validated the sensitivities at [Formula: see text] and [Formula: see text] for the transverse [Formula: see text] and [Formula: see text] gradients, and [Formula: see text] for the [Formula: see text] gradient. DISCUSSION: We found that the chosen relative bi-planar tilt of [Formula: see text] represents a reasonable compromise in terms of overall performance and allows for easier coil implementation with a straight, horizontal alignment within the overall experimental setup.


Asunto(s)
Diamante , Nitrógeno , Nitrógeno/química , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Difusión
3.
Magn Reson Med ; 88(3): 1465-1479, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35526237

RESUMEN

PURPOSE: An automated algorithm for generating realizable MR gradient and shim coil layouts based on the boundary element method is presented here. The overall goal is to reduce postprocessing effort and thus enable for rapid prototyping of new coil designs. For a given surface mesh and target field, the algorithm generates a connected, non-overlapping wire path. METHODS: The proposed algorithm consists of several steps: Stream function optimization, two-dimensional surface projection, potential discretization, topological contour sorting, opening and interconnecting contours, and finally adding non-overlapping return paths. Several technical parameters such as current strength, inductance and field accuracy are assessed for quality control. RESULTS: The proposed method is successfully demonstrated in four different examples. All exemplary results demonstrate high accuracy with regard to reaching the respective target field. The optimal discretization for a given stream function is found by generating multiple layouts while varying the input parameter values. CONCLUSION: The presented algorithm allows for a rapid generation of interconnected coil layouts with high flexibility and low discretization error. This enables to reduce the overall post-processing effort. The source code of this work is publicly available ( https://github.com/Philipp-MR/CoilGen).


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Diseño de Equipo , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Programas Informáticos
4.
J Magn Reson ; 331: 107052, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34478997

RESUMEN

Diffusion-weighted imaging (DWI) in the female breast is a magnetic resonance imaging (MRI) technique that complements clinical routine protocols, and that might provide an independent diagnostic value for specific clinical tasks in breast imaging. To further improve specificity of DWI in the breast, stronger and faster diffusion weighting is advantageous. Here, a dedicated gradient coil is designed, targeted at diffusion weighting in the female breast, with the peak gradient magnitude exceeding that of the current clinical MR scanners by an order of a magnitude. Design of application-tailored gradient coils in MRI has recently attracted increased attention. With the target application in mind, the gradient coil is designed on an irregularly shaped semi-open current-carrying surface. Due to the coil former closely fitting the non-spherical target region, non-linear encoding fields become particularly advantageous for achieving locally exceptionally high gradient strengths. As breast tissue has a predominantly isotropic cellular microstructure, the direction of the diffusion-weighting gradient may be allowed to vary within the target volume. However, due to the quadratic dependency of the b-factor on the gradient strength, variation of the gradient magnitude should be carefully controlled. To achieve the above design goals the corresponding multi-objective optimization problem is reformulated as a constrained optimization, allowing for flexible and precise control of the coil properties. A novel constraint is proposed, limiting gradient magnitude variation within every slice while allowing for variations in both the direction of the gradient within the slice and the magnitude across the slices. These innovations enable the design of a unilateral coil for diffusion weighting in the female breast with local gradient strengths exceeding 1 T/m with highly homogeneous diffusion weighting for imaging in the coronal slice orientation.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Mama/diagnóstico por imagen , Difusión , Femenino , Humanos
5.
Phys Med Biol ; 66(4): 045004, 2021 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-33264755

RESUMEN

Rotating MRI systems could enable novel integrated medical devices such as MRI-Linacs, MRI-xray-angiography systems, and MRI-proton therapy systems. This work aimed to investigate the feasibility of rotating actively shielded superconducting MRI magnets in the presence of environmental steel-in particular, construction steel in the floor of the installation site. Two magnets were investigated: a 1.0 T split bore magnet, and a 1.5 T closed bore magnet. Each magnet was scaled to emulate field strengths of 0.5, 1.0, and 1.5 T. Finite Element Modeling was used to simulate these magnets in the presence of a 3 × 4 m steel plate located 1250 mm or 1400 mm below the isocenter. There are two possible rotation directions: around the longitudinal (z) axis or around the transverse (x) axis. Each model was solved for rotation angles between 0 and 360° in 30° intervals around each of these axes. For each simulation, a 300 mm DSV was extracted and decomposed into spherical harmonics. For the closed-bore magnet, total induced perturbation for the zero degree rotation angle was 223, 432, and 562 µT peak-to-peak (pk-pk) for the 0.5, 1.0, and 1.5 T models respectively (steel at 1250 mm). For the split-bore magnet, the same numbers were 1477, 16747, and 1766 µT. The substantially higher perturbation for the split-bore magnet can be traced to its larger fringe field. For rotation around the z-axis, total perturbation does not change as a function of angle but is exchanged between different harmonics. For rotation around the x-axis, total perturbation is different at each rotation angle. For the closed bore magnet, maximum perturbations occurred for a 90° rotation around the transverse axis. For the split-bore magnet, the opposite was observed, with the same 90° rotation yielding total perturbation lower than the conventional position. In all cases, at least 95% of the total perturbation was composed of 1st and 2nd order harmonics. The presence of environmental steel poses a major challenge to the realization of an actively shielded rotating superconducting MRI system, requiring some novel form of shimming. Possible shimming strategies are discussed at length.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Imanes , Modelos Teóricos , Acero , Aceleradores de Partículas , Rotación
6.
Dentomaxillofac Radiol ; 50(2): 20200068, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201739

RESUMEN

OBJECTIVES: Autologous bone grafts are the gold standard to augment deficient alveolar bone. Dimensional graft alterations during healing are not known as they are not accessible to radiography. Therefore, MRI was used to display autologous onlay bone grafts in vivo during early healing. METHODS AND MATERIALS: Ten patients with alveolar bone atrophy and autologous onlay grafts were included. MRI was performed with a clinical MR system and an intraoral coil preoperatively (t0), 1 week (t1), 6 weeks (t2) and 12 weeks (t3) postoperatively, respectively. The graft volumes were assessed in MRI by manual segmentation by three examiners. Graft volumes for each time point were calculated and dimensional alteration was documented. Cortical and cancellous proportions of bone grafts were assessed. The intraobserver and interobserver variability were calculated. Statistical analysis was performed using a mixed linear regression model. RESULTS: Autologous onlay bone grafts with cortical and cancellous properties were displayed in vivo in eight patients over 12 weeks. The fixation screws were visible as signal voids with a thin hyperintense fringe. The calculated volumes were between 0.12-0.74 cm3 (t1), 0.15-0.73 cm3 (t2), and 0.17-0.64 cm3 (t3). Median changes of bone graft volumes of -15% were observed. There was no significant difference between the examiners (p = 0.3). CONCLUSIONS: MRI is eligible for the display and longitudinal observation of autologous onlay bone grafts. Image artifacts caused measurements deviations in some cases and minimized the precise assessment of graft volume. To the knowledge of the authors, this is the first study that used MRI for the longitudinal observation of autologous onlay bone grafts.


Asunto(s)
Pérdida de Hueso Alveolar , Aumento de la Cresta Alveolar , Trasplante Óseo , Huesos , Humanos , Imagen por Resonancia Magnética , Cicatrización de Heridas
7.
Clin Oral Implants Res ; 31(8): 737-746, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32459868

RESUMEN

OBJECTIVES: The objective of this in vitro study was to assess the accuracy of fully guided implant placement following virtual implant planning based on MRI. MATERIAL AND METHODS: Sixteen human cadaver hemimandibles with single missing teeth (n = 3), partially edentulous (n = 6) and edentulous situations (n = 7) were imaged using MRI. MRI and optical scans obtained with an intraoral scanner, were imported into an implant planning software. Virtual prosthetic and implant planning were performed regarding hard- and soft-tissue anatomy. Drill guides were manufactured, and fully guided implant placement was performed. Buccal and lingual bone and implant nerve distance were measured by three examiners in preoperative MRI and postoperative CBCT. The implant position was assessed using a software for deviation of implant positions displayed in CBCT and optical scans, respectively. RESULTS: MRI displayed relevant structures for implant planning such as cortical and cancellous bone, inferior alveolar nerve and neighboring teeth. Implant planning, CAD/CAM of drill guides and guided implant placement were performed. Deviations between planned and actual implant positions in postoperative CBCT and optical scans were 1.34 mm (SD 0.84 mm) and 1.03 mm (SD 0.46 mm) at implant shoulder; 1.41 mm (SD 0.88 mm) and 1.28 mm (SD 0.52 mm) at implant apex, and 4.84° (SD 3.18°) and 4.21° (SD 2.01°). Measurements in preoperative MRI and postoperative CBCT confirmed the compliance with minimum distances of implants to anatomical structures. CONCLUSIONS: Relevant anatomical structures for imaging diagnostics in implant dentistry are displayed with MRI. The accuracy of MRI-based fully guided implant placement in vitro is comparable to the workflow using CBCT.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Mandíbula , Planificación de Atención al Paciente
8.
Magn Reson Med ; 83(4): 1442-1457, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31565814

RESUMEN

PURPOSE: The purpose of this study is to introduce a novel design method of a shim coil array specifically optimized for whole brain shimming and to compare the performance of the resulting coils to conventional spherical harmonic shimming. METHODS: The proposed design approach is based on the stream function method and singular value decomposition. Eighty-four field maps from 12 volunteers measured in seven different head positions were used during the design process. The cross validation technique was applied to find an optimal number of coil elements in the array. Additional 42 field maps from 6 further volunteers were used for an independent validation. A bootstrapping technique was used to estimate the required population size to achieve a stable coil design. RESULTS: Shimming using 12 and 24 coil elements outperforms fourth- and fifth-order spherical harmonic shimming for all measured field maps, respectively. Coil elements show novel coil layouts compared to the conventional spherical harmonic coils and existing multi-coils. Both leave-one-out and independent validation demonstrate the generalization ability of the designed arrays. The bootstrapping analysis predicts that field maps from approximately 140 subjects need to be acquired to arrive at a stable design. CONCLUSIONS: The results demonstrate the validity of the proposed method to design a shim coil array matched to the human brain anatomy, which naturally satisfies the laws of electrodynamics. The design method may also be applied to develop new shim coil arrays matched to other human organs.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Humanos