Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 19(4)2019 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-30813494

RESUMEN

Myoelectric prostheses help amputees to regain independence and a higher quality of life. These prostheses are controlled by state-of-the-art electromyography sensors, which use a conductive connection to the skin and are therefore sensitive to sweat. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Here, we present ultra-low-power digital signal processing algorithms for an insulated EMG sensor which couples the EMG signal capacitively. These sensors require neither conductive connection to the skin nor electrolytic paste or skin preparation. Capacitive sensors allow straightforward application. However, they make a sophisticated signal amplification and noise suppression necessary. A low-cost sensor has been developed for real-time myoelectric prostheses control. The major hurdles in measuring the EMG are movement artifacts and external noise. We designed various digital filters to attenuate this noise. Optimal system setup and filter parameters for the trade-off between attenuation of this noise and sufficient EMG signal power for high signal quality were investigated. Additionally, an algorithm for movement artifact suppression, enabling robust application in real-world environments, is presented. The algorithms, which require minimal calculation resources and memory, are implemented on an ultra-low-power microcontroller.


Asunto(s)
Electromiografía/métodos , Algoritmos , Humanos , Calidad de Vida , Procesamiento de Señales Asistido por Computador
2.
Sensors (Basel) ; 19(4)2019 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-30813504

RESUMEN

Electromyography (EMG), the measurement of electrical muscle activity, is used in a variety of applications, including myoelectric upper-limb prostheses, which help amputees to regain independence and a higher quality of life. The state-of-the-art sensors in prostheses have a conductive connection to the skin and are therefore sensitive to sweat and require preparation of the skin. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Due to their insulating layer between skin and sensor area, capacitive sensors are insensitive to the skin condition, they require neither conductive connection to the skin nor electrolytic paste or skin preparation. Here, we describe a highly stable, low-power capacitive EMG measurement set-up that is suitable for real-world application. Various flexible multi-layer sensor set-ups made of copper and insulating foils, flex print and textiles were compared. These flexible sensor set-ups adapt to the anatomy of the human forearm, therefore they provide high wearing comfort and ensure stability against motion artifacts. The influence of the materials used in the sensor set-up on the magnitude of the coupled signal was demonstrated based on both theoretical analysis and measurement.The amplifier circuit was optimized for high signal quality, low power consumption and mobile application. Different shielding and guarding concepts were compared, leading to high SNR.


Asunto(s)
Técnicas Biosensibles/métodos , Electromiografía/métodos , Miembros Artificiales , Humanos , Calidad de Vida
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 410-413, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29059897

RESUMEN

As motion artefacts are a major problem with electromyography sensors, a new algorithm is developed to differentiate artefacts to contraction EMG. The performance of myoelectric prosthesis is increased with this algorithm. The implementation is done for an ultra-low-power microcontroller with limited calculation resources and memory. Short Time Fourier Transformation is used to enable real-time application. The sum of the differences (SOD) of the currently measured EMG to a reference contraction EMG is calculated. The SOD is a new parameter introduced for EMG classification. The satisfactory error rates are determined by measurements done with the capacitively coupling EMG prototype, recently developed by the research group.


Asunto(s)
Electromiografía , Algoritmos , Artefactos , Movimiento (Física)
4.
Front Neurorobot ; 11: 7, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28261085

RESUMEN

Missing an upper limb dramatically impairs daily-life activities. Efforts in overcoming the issues arising from this disability have been made in both academia and industry, although their clinical outcome is still limited. Translation of prosthetic research into clinics has been challenging because of the difficulties in meeting the necessary requirements of the market. In this perspective article, we suggest that one relevant factor determining the relatively small clinical impact of myocontrol algorithms for upper limb prostheses is the limit of commonly used laboratory performance metrics. The laboratory conditions, in which the majority of the solutions are being evaluated, fail to sufficiently replicate real-life challenges. We qualitatively support this argument with representative data from seven transradial amputees. Their ability to control a myoelectric prosthesis was tested by measuring the accuracy of offline EMG signal classification, as a typical laboratory performance metrics, as well as by clinical scores when performing standard tests of daily living. Despite all subjects reaching relatively high classification accuracy offline, their clinical scores varied greatly and were not strongly predicted by classification accuracy. We therefore support the suggestion to test myocontrol systems using clinical tests on amputees, fully fitted with sockets and prostheses highly resembling the systems they would use in daily living, as evaluation benchmark. Agreement on this level of testing for systems developed in research laboratories would facilitate clinically relevant progresses in this field.

5.
Sci Rep ; 6: 34960, 2016 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-27721419

RESUMEN

Critical soft tissue injuries may lead to a non-functional and insensate limb. In these cases standard reconstructive techniques will not suffice to provide a useful outcome, and solutions outside the biological arena must be considered and offered to these patients. We propose a concept which, after all reconstructive options have been exhausted, involves an elective amputation along with a bionic substitution, implementing an actuated prosthetic hand via a structured tech-neuro-rehabilitation program. Here, three patients are presented in whom this concept has been successfully applied after mutilating hand injuries. Clinical tests conducted before, during and after the procedure, evaluating both functional and psychometric parameters, document the benefits of this approach. Additionally, in one of the patients, we show the possibility of implementing a highly functional and natural control of an advanced prosthesis providing both proportional and simultaneous movements of the wrist and hand for completing tasks of daily living with substantially less compensatory movements compared to the traditional systems. It is concluded that the proposed procedure is a viable solution for re-gaining highly functional hand use following critical soft tissue injuries when existing surgical measures fail. Our results are clinically applicable and can be extended to institutions with similar resources.


Asunto(s)
Amputación Quirúrgica , Miembros Artificiales , Biónica/métodos , Procedimientos Quirúrgicos Electivos/métodos , Traumatismos de la Mano/cirugía , Traumatismos de los Tejidos Blandos/cirugía , Humanos , Resultado del Tratamiento
6.
IEEE Trans Neural Syst Rehabil Eng ; 24(7): 744-53, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26173217

RESUMEN

Pattern recognition and regression methods applied to the surface EMG have been used for estimating the user intended motor tasks across multiple degrees of freedom (DOF), for prosthetic control. While these methods are effective in several conditions, they are still characterized by some shortcomings. In this study we propose a methodology that combines these two approaches for mutually alleviating their limitations. This resulted in a control method capable of context-dependent movement estimation that switched automatically between sequential (one DOF at a time) or simultaneous (multiple DOF) prosthesis control, based on an online estimation of signal dimensionality. The proposed method was evaluated in scenarios close to real-life situations, with the control of a physical prosthesis in applied tasks of varying difficulties. Test prostheses were individually manufactured for both able-bodied and transradial amputee subjects. With these prostheses, two amputees performed the Southampton Hand Assessment Procedure test with scores of 58 and 71 points. The five able-bodied individuals performed standardized tests, such as the box&block and clothes pin test, reducing the completion times by up to 30%, with respect to using a state-of-the-art pure sequential control algorithm. Apart from facilitating fast simultaneous movements, the proposed control scheme was also more intuitive to use, since human movements are predominated by simultaneous activations across joints. The proposed method thus represents a significant step towards intelligent, intuitive and natural control of upper limb prostheses.


Asunto(s)
Algoritmos , Muñones de Amputación/fisiopatología , Amputados/rehabilitación , Miembros Artificiales , Fuerza de la Mano , Análisis y Desempeño de Tareas , Adulto , Análisis de Falla de Equipo , Retroalimentación , Femenino , Mano , Humanos , Masculino , Diseño de Prótesis
7.
PLoS One ; 10(6): e0127528, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26069961

RESUMEN

Modern assistive devices are very sophisticated systems with multiple degrees of freedom. However, an effective and user-friendly control of these systems is still an open problem since conventional human-machine interfaces (HMI) cannot easily accommodate the system's complexity. In HMIs, the user is responsible for generating unique patterns of command signals directly triggering the device functions. This approach can be difficult to implement when there are many functions (necessitating many command patterns) and/or the user has a considerable impairment (limited number of available signal sources). In this study, we propose a novel concept for a general-purpose HMI where the controller and the user communicate bidirectionally to select the desired function. The system first presents possible choices to the user via electro-tactile stimulation; the user then acknowledges the desired choice by generating a single command signal. Therefore, the proposed approach simplifies the user communication interface (one signal to generate), decoding (one signal to recognize), and allows selecting from a number of options. To demonstrate the new concept the method was used in one particular application, namely, to implement the control of all the relevant functions in a state of the art commercial prosthetic hand without using any myoelectric channels. We performed experiments in healthy subjects and with one amputee to test the feasibility of the novel approach. The results showed that the performance of the novel HMI concept was comparable or, for some outcome measures, better than the classic myoelectric interfaces. The presented approach has a general applicability and the obtained results point out that it could be used to operate various assistive systems (e.g., prosthesis vs. wheelchair), or it could be integrated into other control schemes (e.g., myoelectric control, brain-machine interfaces) in order to improve the usability of existing low-bandwidth HMIs.


Asunto(s)
Miembros Artificiales , Interfaces Cerebro-Computador , Mano/fisiología , Sistemas Hombre-Máquina , Interfaz Usuario-Computador , Adulto , Electromiografía , Femenino , Fuerza de la Mano , Humanos , Masculino , Persona de Mediana Edad
8.
IEEE Trans Neural Syst Rehabil Eng ; 23(5): 827-36, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25296406

RESUMEN

Functional replacement of upper limbs by means of dexterous prosthetic devices remains a technological challenge. While the mechanical design of prosthetic hands has advanced rapidly, the human-machine interfacing and the control strategies needed for the activation of multiple degrees of freedom are not reliable enough for restoring hand function successfully. Machine learning methods capable of inferring the user intent from EMG signals generated by the activation of the remnant muscles are regarded as a promising solution to this problem. However, the lack of robustness of the current methods impedes their routine clinical application. In this study, we propose a novel algorithm for controlling multiple degrees of freedom sequentially, inherently proportionally and with high robustness, allowing a good level of prosthetic hand function. The control algorithm is based on the spatial linear combinations of amplitude-related EMG signal features. The weighting coefficients in this combination are derived from the optimization criterion of the common spatial patterns filters which allow for maximal discriminability between movements. An important component of the study is the validation of the method which was performed on both able-bodied and amputee subjects who used physical prostheses with customized sockets and performed three standardized functional tests mimicking daily-life activities of varying difficulty. Moreover, the new method was compared in the same conditions with one clinical/industrial and one academic state-of-the-art method. The novel algorithm outperformed significantly the state-of-the-art techniques in both subject groups for tests that required the activation of more than one degree of freedom. Because of the evaluation in real time control on both able-bodied subjects and final users (amputees) wearing physical prostheses, the results obtained allow for the direct extrapolation of the benefits of the proposed method for the end users. In conclusion, the method proposed and validated in real-life use scenarios, allows the practical usability of multifunctional hand prostheses in an intuitive way, with significant advantages with respect to previous systems.


Asunto(s)
Algoritmos , Muñones de Amputación/fisiopatología , Amputados/rehabilitación , Miembros Artificiales , Electromiografía/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Análisis de Falla de Equipo , Retroalimentación Fisiológica , Mano , Humanos , Diseño de Prótesis , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
IEEE Trans Neural Syst Rehabil Eng ; 23(5): 807-16, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25222951

RESUMEN

Electrocutaneous stimulation is a promising approach to provide sensory feedback to amputees, and thus close the loop in upper limb prosthetic systems. However, the stimulation introduces artifacts in the recorded electromyographic (EMG) signals, which may be detrimental for the control of myoelectric prostheses. In this study, artifact blanking with three data segmentation approaches was investigated as a simple method to restore the performance of pattern recognition in prosthesis control (eight motions) when EMG signals are corrupted by stimulation artifacts. The methods were tested over a range of stimulation conditions and using four feature sets, comprising both time and frequency domain features. The results demonstrated that when stimulation artifacts were present, the classification performance improved with blanking in all tested conditions. In some cases, the classification performance with blanking was at the level of the benchmark (artifact-free data). The greatest pulse duration and frequency that allowed a full performance recovery were 400 µs and 150 Hz, respectively. These results show that artifact blanking can be used as a practical solution to eliminate the negative influence of the stimulation artifact on EMG pattern classification in a broad range of conditions, thus allowing to close the loop in myoelectric prostheses using electrotactile feedback.


Asunto(s)
Artefactos , Terapia por Estimulación Eléctrica/métodos , Electromiografía/métodos , Retroalimentación Sensorial/fisiología , Músculo Esquelético/fisiología , Tacto/fisiología , Adulto , Algoritmos , Femenino , Humanos , Masculino , Músculo Esquelético/inervación , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
10.
Artículo en Inglés | MEDLINE | ID: mdl-25570045

RESUMEN

In recent years, many sophisticated control strategies for multifunctional dexterous hand prostheses have been developed. It was indeed assumed that control mechanisms based on switching between degrees of freedom, which are in use since the 1960's, could not be extended to efficient control of more than two degrees of freedom. However, quantitative proof for this assumption has not been shown. In this study, we adopted the mode switching paradigm available in commercial prostheses for two degree of freedom control and we extended it for the control of seven functions (3.5 degrees of freedom) in a modern robotic hand. We compared the controllability of this scaled version of the standard method to a state of the art pattern recognition based control in an applied online study. The aim was to quantify whether multi-functional prosthetic control with mode switching outperformed pattern recognition in the control of a real prosthetic hand for daily life activities online. Although in simple grasp-release tasks the conventional method performed best, tasks requiring more complex control of multiple degrees of freedom required a more intuitive control method, such as pattern recognition, for achieving high performance.


Asunto(s)
Mano/fisiología , Robótica , Adulto , Miembros Artificiales , Análisis Discriminante , Electromiografía , Fuerza de la Mano , Humanos , Diseño de Prótesis
11.
Artículo en Inglés | MEDLINE | ID: mdl-23366148

RESUMEN

We present the real time simultaneous and proportional control of two degrees of freedom (DoF), using surface electromyographic signals from the residual limbs of three subject with limb deficiency. Three subjects could control a virtual object in two dimensions using their residual muscle activities to achieve goal-oriented tasks. The subjects indicated that they found the control intuitive and useful. These results show that such a simultaneous and proportional control paradigm is a promising direction for multi-functional prosthetic control.


Asunto(s)
Algoritmos , Amputados/rehabilitación , Electromiografía/instrumentación , Electromiografía/métodos , Procesamiento de Señales Asistido por Computador , Adolescente , Adulto , Retroalimentación , Femenino , Humanos , Masculino , Prótesis e Implantes , Dispositivos de Autoayuda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA