Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Acta Anaesthesiol Scand ; 67(2): 169-176, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36354132

RESUMEN

BACKGROUND: Peripheral nerve blocks (PNB) have recently been recommended in total hip (THA) and knee (TKA) arthroplasty as they may reduce pain, morphine consumption, length of stay (LOS) and complications. However, whether PNBs are associated with early discharge within an enhanced recovery protocol including multimodal analgesia is uncertain. METHODS: An observational multicenter study from January to August 2017 in six Danish Arthroplasty Centers with established fast-track protocols. Prospective recording of preoperative characteristics and information on PNB, LOS and readmissions through the Danish National Patient Registry and medical records. Multiple logistic regression was used to investigate associations between PNB and a LOS >1 day, LOS >4 days, and 30-days readmissions. We also reported on mobilization, pain, opioid and fall-related complications leading to LOS >4 days or readmissions. RESULTS: A total of 2027 (58.6%) THA and 1432 (41.4%) TKAs with a median LOS of 1 day (IQR 1-2) and 5.3% (CI:4.6-6.1) 30-days readmission rate were identified. PNB was used in 40.7% (CI:38.2-43.3) of TKA and 2.7% (CI:2.0-3.5) of THA, but with considerable interdepartmental variation (0.0-89.0% for TKA). There was no association between PNB and LOS >1 day (OR:1.19 CI:0.82-1.72; p = .354), LOS >4 days (OR:1.4 CI:0.68-2.89; p = .359) or 30-days readmissions (OR:1.02 CI:0.63-1.65; p = .935) in TKA. Logistic regression in THA was not possible due to limited use of PNB. In TKA there were 12 (2.1% CI:1.2-3.6) with and 1 (0.1% CI:0.02-0.7) without a PNB, who had mobilization, pain or opioid-related complications, and 5 (0.9% CI:0.4-2.0) versus 4 (0.5% CI:0.2-1.2) who fell. Correspondingly, 2 (3.7% CI:1.0-12.6) and 11 (0.6% CI:0.3-1.0) of THA patients had these complications, while 0 (0.0% CI:0.0-6.6) and 17 (0.8% CI:0.5-1.3) fell. CONCLUSION: Routine use of peripheral nerve blocks was not associated with early discharge or 30-days readmissions in fast-track THA and TKA. Future studies should focus on benefits of PNB in high-risk patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Humanos , Tiempo de Internación , Readmisión del Paciente , Artroplastia de Reemplazo de Rodilla/efectos adversos , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Analgésicos Opioides , Artroplastia de Reemplazo de Cadera/efectos adversos
2.
Sci Rep ; 12(1): 10472, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35729265

RESUMEN

Ponds are often identified by their small size and shallow depths, but the lack of a universal evidence-based definition hampers science and weakens legal protection. Here, we compile existing pond definitions, compare ecosystem metrics (e.g., metabolism, nutrient concentrations, and gas fluxes) among ponds, wetlands, and lakes, and propose an evidence-based pond definition. Compiled definitions often mentioned surface area and depth, but were largely qualitative and variable. Government legislation rarely defined ponds, despite commonly using the term. Ponds, as defined in published studies, varied in origin and hydroperiod and were often distinct from lakes and wetlands in water chemistry. We also compared how ecosystem metrics related to three variables often seen in waterbody definitions: waterbody size, maximum depth, and emergent vegetation cover. Most ecosystem metrics (e.g., water chemistry, gas fluxes, and metabolism) exhibited nonlinear relationships with these variables, with average threshold changes at 3.7 ± 1.8 ha (median: 1.5 ha) in surface area, 5.8 ± 2.5 m (median: 5.2 m) in depth, and 13.4 ± 6.3% (median: 8.2%) emergent vegetation cover. We use this evidence and prior definitions to define ponds as waterbodies that are small (< 5 ha), shallow (< 5 m), with < 30% emergent vegetation and we highlight areas for further study near these boundaries. This definition will inform the science, policy, and management of globally abundant and ecologically significant pond ecosystems.


Asunto(s)
Estanques , Humedales , Ecosistema , Lagos , Agua
3.
Acta Orthop ; 91(6): 693-698, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32757687

RESUMEN

Background and purpose - Despite the good results after total hip arthroplasty (THA), new implants are continuously being developed to improve durability. The Echo Bi-Metric (EBM) THA stem is the successor to the Bi-Metric (BM) THA stem. The EBM stem includes many of the features of the BM stem, but minor changes in the design might improve the clinical performance. We compared the migration behavior with radiostereometric analysis (RSA) of the EBM stem and the BM stem at 24 months and evaluated the clinical outcome. Patients and methods - We randomized 62 patients with osteoarthritis (mean age 64 years, female/male 28/34) scheduled for an uncemented THA to receive either an EBM or a BM THA stem. We performed RSA within 1 week after surgery and at 3, 6, 12, and 24 months. The clinical outcome was evaluated using Harris Hip Score (HHS) and Oxford Hip Score (OHS). Results - At 24 months, we found no statistically significant differences in migration between the two implants. During the first 3 months both the EBM and the BM stems showed visible subsidence (2.5 mm and 2.2 mm respectively), and retroversion (2.5° and 2.2° respectively), but after 3 months this stabilized. The expected increase in HHS and OHS was similar between the groups. Interpretation - The EBM stem showed a migration at 24 months not different from the BM stem, and both stems display satisfying clinical results.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fémur/diagnóstico por imagen , Prótesis de Cadera/efectos adversos , Diseño de Prótesis , Falla de Prótesis/etiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Evaluación de Resultado en la Atención de Salud , Diseño de Prótesis/efectos adversos , Diseño de Prótesis/métodos , Análisis Radioestereométrico/métodos
4.
Glob Chang Biol ; 26(5): 2756-2784, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32133744

RESUMEN

In many regions across the globe, extreme weather events such as storms have increased in frequency, intensity, and duration due to climate change. Ecological theory predicts that such extreme events should have large impacts on ecosystem structure and function. High winds and precipitation associated with storms can affect lakes via short-term runoff events from watersheds and physical mixing of the water column. In addition, lakes connected to rivers and streams will also experience flushing due to high flow rates. Although we have a well-developed understanding of how wind and precipitation events can alter lake physical processes and some aspects of biogeochemical cycling, our mechanistic understanding of the emergent responses of phytoplankton communities is poor. Here we provide a comprehensive synthesis that identifies how storms interact with lake and watershed attributes and their antecedent conditions to generate changes in lake physical and chemical environments. Such changes can restructure phytoplankton communities and their dynamics, as well as result in altered ecological function (e.g., carbon, nutrient and energy cycling) in the short- and long-term. We summarize the current understanding of storm-induced phytoplankton dynamics, identify knowledge gaps with a systematic review of the literature, and suggest future research directions across a gradient of lake types and environmental conditions.


Asunto(s)
Lagos , Fitoplancton , Cambio Climático , Ecosistema , Ríos
5.
Proc Biol Sci ; 284(1862)2017 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-28904141

RESUMEN

A common perception in limnology is that shallow lakes are homogeneously mixed owing to their small water volume. However, this perception is largely gained by downscaling knowledge from large lakes to their smaller counterparts. Here we show that shallow vegetated lakes (less than 0.6 m), in fact, undergo recurring daytime stratification and nocturnal mixing accompanied by extreme chemical variations during summer. Dense submerged vegetation effectively attenuates light and turbulence generating separation between warm surface waters and much colder bottom waters. Photosynthesis in surface waters produces oxygen accumulation and CO2 depletion, whereas respiration in dark bottom waters causes anoxia and CO2 accumulation. High daytime pH in surface waters promotes precipitation of CaCO3 which is re-dissolved in bottom waters. Nocturnal convective mixing re-introduces oxygen into bottom waters for aerobic respiration and regenerated inorganic carbon into surface waters, which supports intense photosynthesis. Our results reconfigure the basic understanding of local environmental gradients in shallow lakes, one of the most abundant freshwater habitats globally.


Asunto(s)
Ciclo del Carbono , Lagos/química , Oxígeno/análisis , Carbonato de Calcio/análisis , Carbono/análisis , Dióxido de Carbono/análisis , Fotosíntesis , Agua
6.
J Arthroplasty ; 32(7): 2141-2146, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28410836

RESUMEN

BACKGROUND: The fixation of uncemented tibia components in total knee arthroplasty may rely on the bone quality of the tibia; however, no previous studies have shown convincing objective proof of this. Component migration is relevant as it has been shown to predict aseptic loosening. METHODS: We performed 2-year follow-up of 92 patients who underwent total knee arthroplasty surgery with an uncemented tibia component. Bone mineral density (BMD; g/cm2) of the tibia host bone was measured preoperatively using dual energy X-ray absorptiometry. The proximal tibia was divided into 2 regions of interest (ROI) in the part of the tibia bone where the components were implanted. Radiostereometric analysis was performed postoperatively and after 3, 6, 12, and 24 months. The primary outcome was maximum total point motion (MTPM; mm). Regression analysis was performed to evaluate the relation between preoperative BMD and MTPM. RESULTS: We found low preoperative BMD in ROI1 to be significantly related to high MTPM at all follow-ups: after 3 months (R2 = 20%, PBMD = 0.017), 6 months (R2 = 29%, PBMD = 0.003), 12 months (R2 = 33%, PBMD = 0.001), and 24 months (R2 = 27%, PBMD = 0.001). We also found a significant relation for low BMD in ROI2 and high MTPM: 3 months (R2 = 19%, PBMD = 0.042), 6 months (R2 = 28%, PBMD = 0.04), 12 months (R2 = 32%, PBMD = 0.004), and 24 months (R2 = 24%, PBMD = 0.005). CONCLUSION: Low preoperative BMD in the tibia is related to high MTPM. Thus, high migration of uncemented tibia components is to be expected in patients with poor bone quality.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Densidad Ósea , Prótesis de la Rodilla/efectos adversos , Tibia/cirugía , Absorciometría de Fotón , Anciano , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Prótesis de la Rodilla/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Análisis Radioestereométrico , Análisis de Regresión , Tibia/fisiología
7.
PLoS One ; 11(3): e0152466, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27023200

RESUMEN

Ecological and biogeochemical processes in lakes are strongly dependent upon water temperature. Long-term surface warming of many lakes is unequivocal, but little is known about the comparative magnitude of temperature variation at diel timescales, due to a lack of appropriately resolved data. Here we quantify the pattern and magnitude of diel temperature variability of surface waters using high-frequency data from 100 lakes. We show that the near-surface diel temperature range can be substantial in summer relative to long-term change and, for lakes smaller than 3 km2, increases sharply and predictably with decreasing lake area. Most small lakes included in this study experience average summer diel ranges in their near-surface temperatures of between 4 and 7°C. Large diel temperature fluctuations in the majority of lakes undoubtedly influence their structure, function and role in biogeochemical cycles, but the full implications remain largely unexplored.


Asunto(s)
Lagos/química , Temperatura , Modelos Estadísticos , Modelos Teóricos , Factores de Tiempo , Agua/química
8.
J Clin Densitom ; 19(2): 202-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-25843447

RESUMEN

Loss of bone stock and stress shielding is a significant challenge in limb salvage surgery. This study investigates the adaptive bone remodeling of the femoral bone after implantation of a tumor prosthesis with an uncemented press fit stem. We performed a prospective 1 yr follow-up of 6 patients (mean age: 55 (26-78) yr, female/male=3/3) who underwent bone tumor resection surgery of the proximal femur (n=3) or distal femur (n=3). Reconstruction was done using a Global Modular Replacement System (Stryker® Orthopaedics, Mahwah, NJ) tumor prosthesis, and all patients received a straight-fluted 125-mm uncemented press-fit titanium alloy stem with hydroxyapatite coating of the proximal part of the stem. Measurements of bone mineral density (BMD; g/cm2) were done postoperatively and after 3, 6, and 12 mo in the part of the femur bone containing the Global Modular Replacement System stem using dual-energy X-ray absorptiometry. BMD was measured in 3 regions of interest (ROIs) in the femur bone. Nonparametric analysis of variance (Friedman test) for evaluation of changes in BMD over time. BMD decreased in all 3 ROIs with time. In ROI 1 (p=0.01), BMD decreased by 10% after 3 mo and ended with a total decrease of 14% after 1 yr. In ROI 2 (p=0.006), BMD was decreased by 6% after 3 and 6 mo; after 1 yr of follow-up, BMD was 9% below the postoperative value. In ROI 3 (p=0.009), BMD decreased by 6% after 3 and 6 mo; after 1 yr of follow-up, BMD was 8% below the postoperative value. A bone loss of 8%-9% during the first postoperative year was seen along the femoral stem, but in the bone containing the hydroxyapatite-coated part of the stem, the decrease in BMD was 14%, thus indicating that stress shielding of this part of the bone may play a role for the adaptive bone remodeling.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Neoplasias Óseas , Remodelación Ósea , Durapatita/farmacología , Fémur , Prótesis de Cadera , Osteoporosis , Complicaciones Posoperatorias , Sarcoma de Ewing , Absorciometría de Fotón/métodos , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Materiales Biocompatibles/farmacología , Densidad Ósea , Neoplasias Óseas/patología , Neoplasias Óseas/cirugía , Dinamarca , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoporosis/diagnóstico , Osteoporosis/etiología , Osteoporosis/prevención & control , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/prevención & control , Diseño de Prótesis , Sarcoma de Ewing/patología , Sarcoma de Ewing/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...