Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 275
Filtrar
1.
J Clin Med ; 13(9)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38731227

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) has evolved as first-line therapy for severe aortic valve stenosis (AS), with pre-procedural computed tomography (CT) providing critical anatomical information. While primarily used for anatomical planning, TAVR-CT also offers an opportunity to assess low bone mineral density (BMD), a known indicator of frailty. Despite this, the prognostic role of BMD in TAVR patients remains unknown. This study aimed to evaluate BMD on routine TAVR-CT and its impact on long-term survival. Methods: In this retrospective study, 770 consecutive TAVR patients (mean age 80.7 ± 6.7 years, 54.0% males) between November 2015 and March 2022 were included. BMD was measured from a single axial image at the thoracic vertebral level on unenhanced CT scans. Cox regression models assessed the impact of BMD on mortality, and Restricted Cubic Spline models identified potential mortality thresholds. Results: The mean BMD value, as measured on non-contrast CT, was 147.5 ± 5.4 Hounsfield units, demonstrating a noteworthy association with mortality (adjusted hazard ratio per 100 HU decrease: 1.27 [95%CI: 1.01-1.59], p = 0.041). Restricted cubic spline analysis indicated that BMD below 200 HU was linked to a substantial increase in mortality risk. Upon crude Cox regression analysis, every 100 HU decrease was associated with a 32% increase in risk for death (HR 1.32 [95%CI: 1.068-1.65)], p = 0.010). Conclusions: In conclusion, low BMD on TAVR-CT is independently associated with reduced survival, suggesting its potential as a tool for comprehensive frailty assessment and improved risk prediction in TAVR patients.

2.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
3.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599688

RESUMEN

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de Registros
4.
J Clin Med ; 13(6)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38541839

RESUMEN

Background: Repeat sacrocolpopexy (reSCP) for recurrent pelvic organ prolapse (POP) is a rare and complex condition with little understanding of how to manage. Most authors recommend complete reSCP regardless of the underlying cause of the failure. This retrospective cohort study presents our management workflow and how to systematically approach this challenging situation. Methods: From 2017 to 2021, we analyzed all women undergoing surgery for recurrent POP after sacrocolpopexy at our tertiary referral hospital at the department of urogynecology. Preoperatively, all women underwent a structured work-up consisting of answering the validated German female pelvic floor questionnaires, a clinical examination utilizing the POP-Q staging system according to the International Continence Society (ICS), and a pelvic floor ultrasound. The surgical management was based on the preoperative findings and was adapted individually during surgery if indicated according to the estimated underlying problem for recurrence. Results: In total, 377 women underwent a primary laparoscopic sacrocolpopexy. However, ten women presented with a symptomatic recurrent prolapse requiring further surgical intervention. A reSCP was performed in eight women, including two with additional laparoscopic paravaginal repair to correct the displaced mesh placement at initial surgery. A vaginal correction was indicated in two women with an isolated posterior compartment prolapse. The analysis demonstrates that reSCP has a low intraoperative complication rate and high subjective and objective success rates. Conclusions: We could demonstrate that individualized reSCP after initial SCP is a challenging yet feasible and safe treatment option, but there may be suitable alternatives. If women undergo pre- and intraoperative standardized problem-oriented examinations, we can often identify the cause of the recurrent prolapse. Tailored surgery must be subsequently performed.

5.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38437953

RESUMEN

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Asunto(s)
Cateterismo Cardíaco , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Anciano , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Ecocardiografía/métodos
6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38532304

RESUMEN

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients. METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9-55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6 mm (standard deviation 2.4). The median operation duration was 312 min (IQR 234-417), the median cardiopulmonary bypass time was 154 min (IQR 118-212) and the median cross-clamp time 121 min (IQR 93-150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5 h postoperation. There were 3 late deaths, 1 death due to endocarditis 4 months postoperatively and 2 unrelated deaths after 5 and 7 years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9 years [IQR 5.1-6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0 mmHg (IQR 7.8-17.6) and regurgitation of median 0.5 (IQR 0-0.5) of grade 0-3 were excellent. At 5 years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively. CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Humanos , Masculino , Aloinjertos/cirugía , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Endocarditis/cirugía , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Reoperación , Datos de Salud Recolectados Rutinariamente , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad
7.
Front Cardiovasc Med ; 11: 1363336, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38322769

RESUMEN

Objectives: To date, there is no evidence regarding the safety of automated titanium fastener compared with hand-tied knots for prosthesis fixation in infective endocarditis. Methods: Between January 2016 and December 2022, a total of 220 patients requiring surgery for infective endocarditis were included in this retrospective analysis. The primary study endpoint was re-endocarditis during follow-up. The secondary study endpoints included stroke onset, all-cause mortality, and a composite outcome of either re-endocarditis, stroke, or all-cause mortality during follow-up. Results: Suture-securing with an automated titanium fastener was performed in 114 (51.8%) patients, whereas the conventional technique of hand knot-tying was used in 106 (48.2%) patients. The risk of re-endocarditis was significantly lower in the automated titanium fastener group, as shown in a multivariable proportional competing risk regression model (adjusted sub-hazard ratio 0.33, 95% confidence interval 0.11-0.99, p = 0.048). The multivariable Cox proportional hazards regression analysis showed that the automated titanium fastener group was not associated with an increased risk of stroke-onset or attaining the composite outcome, respectively, (adjusted hazard ratio 0.54, 95% confidence interval 0.27-1.08, p = 0.082), (adjusted hazard ratio 0.65, 95% confidence interval 0.42-1.02, p = 0.061). Also, this group was not associated with an increased risk of all-cause mortality, as demonstrated in the multivariable Poisson regression analysis (adjusted incidence-rate ratio 1.42, 95% confidence interval 0.83-2.42, p = 0.202). Conclusions: The use of automated titanium fastener device seems to be safe for infective endocarditis. Analyses of larger cohorts are required.

8.
Mhealth ; 10: 8, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38323143

RESUMEN

Background: This systematic review aims to highlight the untapped potential of heart rate variability (HRV) and atrial fibrillation (AF) monitoring by wearable health monitoring devices as a critical diagnostic tool in cardiac surgery (CS) patients. We reviewed established predictive capabilities of HRV and AF monitoring in specific cardiosurgical scenarios and provide a perspective on additional predictive properties of wearable health monitoring devices that need to be investigated. Methods: After screening most relevant databases, we included 33 publications in this review. Perusing these publications on HRV's prognostic value, we could identify HRV as a predictor for sudden cardiac death, mortality after acute myocardial infarction (AMI), and post operative atrial fibrillation (POAF). With regards to standard AF assessment, which typically includes extensive periods of unrecorded cardiac activity, we demonstrated that continuous monitoring via wearables recorded significant cardiac events that would otherwise have been missed. Results: Photoplethysmography and single-lead electrocardiogram (ECG) were identified as the most useful and convenient technical assessment modalities, and their advantages and disadvantages were described in detail. As a call to further action, we observed that the scientific community has relatively extensively explored wearable AF screening, whereas HRV assessment to improve relevant clinical outcomes in CS is rarely studied; it still has great potential to be leveraged. Conclusions: Therefore, risk assessment in CS would benefit greatly from earlier preoperative and postoperative AF detection, comprehensive and accurate assessment of cardiac health through HRV metrics, and continuous long-term monitoring. These should be achievable via commercially available wearables.

9.
Am Heart J ; 270: 86-94, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38309610

RESUMEN

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Puente de Arteria Coronaria , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
10.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38385922

RESUMEN

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Sistema de Registros
11.
Eur Heart J Cardiovasc Imaging ; 25(5): 718-726, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38236149

RESUMEN

AIMS: Transcatheter aortic valve replacement (TAVR) revolutionized the therapy of severe aortic stenosis (AS) with rising numbers. Mixed aortic valve disease (MAVD) treated by TAVR is gaining more interest, as those patients represent a more complex cohort as compared with isolated AS. However, concerning long-term outcome for this cohort only, limited data are available. The aim of the study is to assess the prevalence of MAVD in TAVR patients, investigate its association with paravalvular regurgitation (PVR), and analyse its impact on long-term mortality after TAVR. METHODS AND RESULTS: We conducted a registry-based cohort study using the Vienna TAVR registry, enrolling patients who underwent TAVR at Medical University of Vienna between January 2007 and May 2020 with available transthoracic echocardiography before and after TAVR (n = 880). Data analysis included PVR incidence and long-term survival outcomes. A total of 647 (73.52%) out of 880 patients had ≥ mild aortic regurgitation next to severe AS. MAVD was associated with PVR compared with isolated AS with an odds ratio of 2.06, 95% confidence interval (CI): 1.51-2.81 (P = <0.001). More than mild PVR after TAVR (n = 168 out of 880: 19.09%) was related to higher mortality compared with the absence of PVR with a hazard ratio (HR) of 1.33, 95% CI: 1.05- 1.67 (P = 0.016). MAVD patients developing ≥ mild PVR after TAVR were also associated with higher mortality compared with the absence of PVR with an HR of 1.30 and 95% CI: 1.04-1.62 (P = 0.022). CONCLUSION: MAVD is prevalent among TAVR patients and presents unique challenges, with increased PVR risk and worse outcomes compared with isolated AS. Long-term survival for MAVD patients, not limited to those developing PVR post-TAVR, is compromised. Earlier intervention before the occurrence of structural myocardial damage or surgical valve replacement might be a potential workaround to improve outcomes.


Asunto(s)
Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Ecocardiografía , Tasa de Supervivencia , Estudios Retrospectivos , Austria/epidemiología , Índice de Severidad de la Enfermedad , Enfermedad de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Estudios de Cohortes , Medición de Riesgo , Factores de Riesgo
12.
Am Heart J ; 269: 158-166, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38163616

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Simulación por Computador , Calidad de Vida , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos
13.
Viruses ; 16(1)2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-38257821

RESUMEN

Microvascular integrity is a critical factor in myocardial fluid homeostasis. The subtle equilibrium between capillary filtration and lymphatic fluid removal is disturbed during pathological processes leading to inflammation, but also in hypoxia or due to alterations in vascular perfusion and coagulability. The degradation of the glycocalyx as the main component of the endothelial filtration barrier as well as pericyte disintegration results in the accumulation of interstitial and intracellular water. Moreover, lymphatic dysfunction evokes an increase in metabolic waste products, cytokines and inflammatory cells in the interstitial space contributing to myocardial oedema formation. This leads to myocardial stiffness and impaired contractility, eventually resulting in cardiomyocyte apoptosis, myocardial remodelling and fibrosis. The following article reviews pathophysiological inflammatory processes leading to myocardial oedema including myocarditis, ischaemia-reperfusion injury and viral infections with a special focus on the pathomechanisms evoked by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. In addition, clinical implications including potential long-term effects due to viral persistence (long COVID), as well as treatment options, are discussed.


Asunto(s)
COVID-19 , Virosis , Humanos , COVID-19/complicaciones , Síndrome Post Agudo de COVID-19 , SARS-CoV-2 , Progresión de la Enfermedad , Edema
14.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
15.
Clin Cardiol ; 47(2): e24197, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38069663

RESUMEN

BACKGROUND: Postinterventional sonographic assessment of the femoral artery after transfemoral transcatheter aortic valve replacement (TF-TAVR) has the potential to identify several pathologies. We investigated the incidence and risk factors of femoral vessel complications in a modern TAVR collective using postinterventional sonography. METHODS: Between September 2017 and March 2022, 480 patients underwent TF-TAVR with postinterventional femoral sonography at a single center. Clinical outcomes and adverse events were analyzed after the Valve Academic Research Consortium 3 (VARC-3) criteria. RESULTS: In this cohort (51.2% male; age 80 ± 7.5 years, median EuroSCORE II 3.7) 74.8% (n = 359) were implanted with a self-expandable and 25.2% (n = 121) with a balloon-expandable valve. The main access (valve-delivery) was located right in 91.4% (n = 438), and the primary closure system was Proglide in 95% (n = 456). Vascular complications (VC) were observed in 29.16% (n = 140) of patients; 23.3% (n = 112) presented with minor- and 5.8% (n = 28) with major VC. Postinterventional femoral artery stenosis on the main access was observed in 9.8% (n = 47). Multivariable logistic regression analysis revealed female sex (p = .03, odds ratio [OR] 2.32, 95% confidence interval [CI] 1.09-4.89) and the number of used endovascular closure devices (p = .014, OR 0.11, 95%CI 0.02-0.64) as predictive factors for femoral artery stenosis. CONCLUSIONS: The incidence of postinterventional femoral artery stenosis following TF-TAVR was higher than expected with a number of used closure devices and female sex being independent risk factors. Considering the continuous advance of TAVR in low-risk patients with preserved physical activity, emphasis should be directed at the correct diagnosis and follow-up of these complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades Vasculares , Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Constricción Patológica/complicaciones , Constricción Patológica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estudios Retrospectivos
16.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
17.
Acta Biomater ; 175: 1-26, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38092252

RESUMEN

Biomechanical characterization of meniscal tissue ex vivo remains a critical need, particularly for the development of suitable meniscus replacements or therapeutic strategies that target the native mechanical properties of the meniscus. To date, a huge variety of test configurations and protocols have been reported, making it extremely difficult to compare the respective outcome parameters, thereby leading to misinterpretation. Therefore, the purpose of this systematic review was to identify test-specific parameters that contribute to uncertainties in the determination of mechanical properties of the human meniscus and its attachments, which derived from common quasi-static and dynamic tests in tension, compression, and shear. Strong evidence was found that the determined biomechanical properties vary significantly depending on the specific test parameters, as indicated by up to tenfold differences in both tensile and compressive properties. Test mode (stress relaxation, creep, cyclic) and configuration (unconfined, confined, in-situ), specimen shape and dimensions, preconditioning regimes, loading rates, post-processing of experimental data, and specimen age and degeneration were identified as the most critical parameters influencing the outcome measures. In conclusion, this work highlights an unmet need for standardization and reporting guidelines to facilitate comparability and may prove beneficial for evaluating the mechanical properties of novel meniscus constructs. STATEMENT OF SIGNIFICANCE: The biomechanical properties of the human meniscus have been studied extensively over the past decades. However, it remains unclear to what extent both test protocol and specimen-related differences are responsible for the enormous variability in material properties. Therefore, this systematic review analyzes the biomechanical properties of the human meniscus in the context of the underlying testing protocol. The most sensitive parameters affecting the determination of mechanical properties were identified and critically discussed. Currently, it is of utmost importance for scientists evaluating potential meniscal scaffolds and biomaterials to have a control group rather than a direct comparison to the literature. Standardization of both test procedures and reporting requirements is needed to improve and accelerate the development of meniscal replacement constructs.


Asunto(s)
Meniscos Tibiales , Menisco , Humanos , Fenómenos Biomecánicos , Materiales Biocompatibles , Fuerza Compresiva
18.
Cell Tissue Bank ; 25(1): 55-66, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36917328

RESUMEN

For decades, bovine jugular vein conduits (BJV) and classic cryopreserved homografts have been the two most widely used options for pulmonary valve replacement (PVR) in congenital heart disease. More recently, decellularized pulmonary homografts (DPH) have provided an alternative avenue for PVR. Matched comparison of patients who received DPH for PVR with patients who received bovine jugular vein conduits (BJV) considering patient age group, type of heart defect, and previous procedures. 319 DPH patients were matched to 319 BJV patients; the mean age of BJV patients was 15.3 (SD 9.5) years versus 19.1 (12.4) years in DPH patients (p = 0.001). The mean conduit diameter was 24.5 (3.5) mm for DPH and 20.3 (2.5) mm for BJV (p < 0.001). There was no difference in survival rates between the two groups after 10 years (97.0 vs. 98.1%, p = 0.45). The rate of freedom from endocarditis was significantly lower for BJV patients (87.1 vs. 96.5%, p = 0.006). Freedom from explantation was significantly lower for BJV at 10 years (81.7 vs. 95.5%, p = 0.001) as well as freedom from any significant degeneration at 10 years (39.6 vs. 65.4%, p < 0.001). 140 Patients, matched for age, heart defect type, prior procedures, and conduit sizes of 20-22 mm (± 2 mm), were compared separately; mean age BJV 8.7 (4.9) and DPH 9.5 (7.3) years (p = n.s.). DPH showed 20% higher freedom from explantation and degeneration in this subgroup (p = 0.232). Decellularized pulmonary homografts exhibit superior 10-year results to bovine jugular vein conduits in PVR.


Asunto(s)
Cardiopatías Congénitas , Válvula Pulmonar , Humanos , Bovinos , Animales , Lactante , Adolescente , Niño , Válvula Pulmonar/trasplante , Venas Yugulares/trasplante , Resultado del Tratamiento , Cardiopatías Congénitas/cirugía , Aloinjertos , Estudios Retrospectivos
19.
Eur Heart J Cardiovasc Imaging ; 25(3): 365-372, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-37861385

RESUMEN

AIMS: Transcatheter tricuspid edge-to-edge repair (T-TEER) has gained widespread use for the treatment of tricuspid regurgitation (TR) in symptomatic patients with high operative risk. Although secondary TR is the most common pathology, some patients exhibit primary or predominantly primary TR. Characterization of patients with these pathologies in the T-TEER context has not been systematically performed. METHODS AND RESULTS: Patients assigned to T-TEER by the interdisciplinary heart team were consecutively recruited in two European centres over 4 years. Echocardiographic images were evaluated to distinguish between primary and secondary causes of TR. Both groups were compared concerning procedural results. A total of 339 patients were recruited, 13% with primary TR and 87% with secondary TR. Patients with primary TR had a smaller right ventricle (basal diameter 45 vs. 49 mm, P = 0.004), a better right ventricular function (fractional area change 45 vs. 41%, P = 0.001), a smaller right (28 vs. 34 cm2, P = 0.021) and left (52 vs. 67 mL/m2, P = 0.038) atrium, and a better left ventricular ejection fraction (60 vs. 52%, P = 0.005). The severity of TR was similar in primary and secondary TR at baseline (TR vena contracta width pre-interventional 13 ± 4 vs. 14 ± 5 mm, P = 0.19), and T-TEER significantly reduced TR in both groups (TR vena contracta width post-interventional 4 ± 3 vs. 5 ± 5 mm, P = 0.10). These findings remained stable after propensity score matching. Complications were similar between both groups. CONCLUSION: T-TEER confers equally safe and effective reduction of TR in patients with primary and secondary TR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Prolapso de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Prolapso de la Válvula Tricúspide/etiología , Prolapso de la Válvula Tricúspide/cirugía , Volumen Sistólico , Estudios de Factibilidad , Resultado del Tratamiento , Función Ventricular Izquierda , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos
20.
Ann Thorac Surg ; 117(2): 474-478, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37890817

RESUMEN

PURPOSE: A new automated expanded polytetrafluoroethylene (ePTFE) suture placement device and a new customized titanium fastener deployment device were clinically evaluated in open and less-invasive mitral valve repair (MVr). DESCRIPTION: Twelve patients were monitored for 1 year after undergoing MVr using the study devices. The study end points included surgical outcomes, operative times, valve repair durability, adverse events, and mortality. EVALUATION: Three patients received 1 ePTFE chord using the study technology, and 9 patients received 2 chords. Mitral regurgitation at 30 days was absent in 8 patients, trace in 2, and mild in 2. At the 1-year follow-up, mitral regurgitation was absent in 7 patients, trace in 2, mild in 2, and moderate in 1. There were no replacement chord failures, reoperations, or death. CONCLUSIONS: The initial outcomes of new automated ePTFE suture placement and titanium fastener deployment devices encourage further clinical evaluations.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/cirugía , Titanio , Resultado del Tratamiento , Suturas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cuerdas Tendinosas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...