Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Medicine (Baltimore) ; 102(22): e33900, 2023 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-37266644

RESUMEN

The purpose of this study was to evaluate the impact of breast density on the diagnostic performance of cone-beam breast-CT (CBBCT) in comparison to full-field digital mammography (FFDM) for the detection of microcalcifications. This retrospective IRB-approved study was conducted between December 2015 and March 2017 and enrolled 171 women with Breast Imaging Reporting and Data System category 4 or 5 lesions on FFDM and additional CBBCT; 56 of which were ineligible. The inclusion was restricted to 83 women (90 breasts, 90 lesions) with microcalcifications. All lesions underwent histology or were monitored by FFDM and a clinical examination at least 2 years after enrollment. Two breast radiologists independently read each data set twice. Sensitivity, specificity and area under the curve were compared between the modalities. Thirty-two breasts (35.5%) were grouped as non-dense breasts (American College of Radiology types a/b) and 58 breasts (64.5%) as dense breasts (American College of Radiology types c/d). Histopathological assessment was performed in 61 of 90 breast lesions (32 malignant, 1 high-risk and 28 benign). Area under the curve was larger for FFDM than for CBBCT (P = .085). The sensitivity was significantly higher for FFDM compared to CBBCT (P = .009). The specificity showed no significant differences comparing FFDM (both readers: 0.62) versus CBBCT (reader 1: 0.76, reader 2: 0.60; P = .192). Inter-observer-reliability on BI-RADS readings was almost perfect for FFDM and moderate for CBBCT (κ = 0.84, κ = 0.54, respectively). Intra-observer agreement was substantial to almost perfect for both methods and readers. Compared with FFDM, CBBCT demonstrated non-comparable results for microcalcification detection in dense and non-dense breasts.


Asunto(s)
Enfermedades de la Mama , Neoplasias de la Mama , Calcinosis , Femenino , Humanos , Densidad de la Mama , Estudios Retrospectivos , Reproducibilidad de los Resultados , Mamografía/métodos , Enfermedades de la Mama/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Calcinosis/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...