Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Talanta ; 117: 235-41, 2013 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-24209335

RESUMEN

A sample pre-treatment method based on blood spot collection filter cards was optimized as a means of using small volume samples for the screening and confirmation of cocaine and opiates abuse. Dried blood spots (DBSs) were prepared by dispersing 20 µL of whole blood specimens previously mixed with the internal standards (deuterated analogs of each target), and subjecting the whole DBS to extraction with 5 mL of methanol under orbital-horizontal shaking (180 rpm) for 10 min. Determinations were based on direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) by injecting the re-dissolved methanol extract with the delivery solution (acetonitrile-water-formic acid, 80:19.875:0.125) at a flow rate of 60 µL min(-1), and using multiple reaction monitoring (MRM) mode with the m/z (precursor ion)→m/z (product ion) transitions for acquisition. Matrix effect has been found to be statistically significant (Multiple Range Test) when assessing cocaine, BZE, codeine and morphine, and the use of the standard addition method (dispersion of whole blood previously mixed with standards onto the filter papers) was needed for accurate determinations. The developed DBS-ESI-MS/MS procedure offered good intra-day and inter-day precisions (lower than 10% and 12%, respectively), as well as good intra-day and inter-day accuracies (inter-day absolute recoveries, expressed as the mean analytical recovery over three target concentration levels, of 103%, 100%, 101%, 98% and 100% for cocaine, BZE, codeine, morphine and 6-MAM, respectively). The high sensitivity inherent to MS/MS determinations combined with the minimal dilution of sample allowed low limits of quantification for all targets, and the developed method results therefore adequate for cocaine and opiates screening and confirmation purposes. The procedure was finally applied to DBSs prepared from whole blood from polydrug abusers, and results were compared with those obtained after a conventional sample pretreatment method based on solid phase extraction for plasma specimens and gas chromatography-mass spectrometry.


Asunto(s)
Analgésicos Opioides/sangre , Cocaína/sangre , Codeína/sangre , Pruebas con Sangre Seca/métodos , Morfina/sangre , Trastornos Relacionados con Sustancias/sangre , Humanos , Límite de Detección , Metanol/química , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...