Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38109676

RESUMEN

OBJECTIVES: Post-acute myocardial infarction mechanical complications (post-AMI MCs) represent rare but life-threatening conditions, including free-wall rupture, ventricular septal rupture and papillary muscle rupture. During the coronavirus disease-19 (COVID-19) pandemic, an overwhelming pressure on healthcare systems led to delayed and potentially suboptimal treatments for time-dependent conditions. As AMI-related hospitalizations decreased, limited information is available whether higher rates of post-AMI MCs and related deaths occurred in this setting. This study was aimed to assess how COVID-19 in Europe has impacted the incidence, treatment and outcome of MCs. METHODS: The CAUTION-COVID19 study is a multicentre retrospective study collecting 175 patients with post-AMI MCs in 18 centres from 6 European countries, aimed to compare the incidence of such events, related patients' characteristics, and outcomes, between the first year of pandemic and the 2 previous years. RESULTS: A non-significant increase in MCs was observed [odds ratio (OR) = 1.15, 95% confidence interval (CI) 0.85-1.57; P = 0.364], with stronger growth in ventricular septal rupture diagnoses (OR = 1.43, 95% CI 0.95-2.18; P = 0.090). No significant differences in treatment types and mortality were found between the 2 periods. In-hospital mortality was 50.9% and was higher for conservatively managed cases (90.9%) and lower for surgical patients (44.0%). Patients admitted during COVID-19 more frequently had late-presenting infarction (OR = 2.47, 95% CI 1.24-4.92; P = 0.010), more stable conditions (OR = 2.61, 95% CI 1.27-5.35; P = 0.009) and higher EuroSCORE II (OR = 1.04, 95% CI 1.01-1.06; P = 0.006). CONCLUSIONS: A non-significant increase in MCs incidence occurred during the first year of COVID-19, characterized by a significantly higher rate of late-presenting infarction, stable conditions and EuroSCORE-II if compared to pre-pandemic data, without affecting treatment and mortality.

2.
Am J Cardiol ; 189: 86-92, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36516701

RESUMEN

The intra-aortic balloon pump (IABP) is the most widely available mechanical support device, but its use has been disputed in recent decades. Although several efforts have been made to reduce the associated complication rate, contemporary data on this matter is lacking. The present study aims to evaluate the differences in vascular complications between the sheathless and the sheathed IABP implantation technique in cardiac surgery patients. A retrospective multi-center cohort, consisting of patients treated in 8 cardiac surgical centers, was evaluated. Patients who underwent cardiac surgery with peri-operative IABP support were included. Primary outcome was a composite end point of vascular complications. Propensity score matching (PSM) was performed, and a multivariable regression model was applied to evaluate predictors of vascular complications. The unmatched cohort consisted of 2,615 patients (sheathless n = 1,414, 54%, sheathed n = 1,201, 46%). A total of 878 patients were matched (n = 439 for both groups). The composite vascular complication end point occurred in 3% of patients in the sheathless group, compared with 8% in the sheathed group (p <0.001). Vascular complications were significantly associated with mortality (odds ratio [OR] 3.86, 95% confidence interval [CI] 2.01 to 7.40, p <0.001). Peripheral arterial disease was associated with vascular complications (OR 3.10, 95% CI 1.46 to 6.55, p = 0.003), whereas the sheathless implantation technique was found to be protective (OR 0.36, 95% CI 0.18 to 0.73, p = 0.005). In conclusion, the present retrospective multi-center analysis demonstrated the sheathless implantation technique to be associated with a significant reduction in vascular complication rate. Future studies should focus on even less invasive implantation techniques using smaller-sized catheters, sheathless implantation, and imaging guiding.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Corazón Auxiliar , Enfermedad Arterial Periférica , Humanos , Factores de Riesgo , Contrapulsador Intraaórtico , Estudios Retrospectivos , Enfermedad Arterial Periférica/etiología , Resultado del Tratamiento
3.
Int J Cardiol ; 371: 116-120, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36108764

RESUMEN

OBJECTIVES: The role of the underlying etiology in isolated tricuspid valve surgery has not been investigated extensively in current literature. Aim of this study was to analyse outcomes of patients undergoing surgery due to endocarditis compared to other pathologies. METHODS: The SURTRI study is a multicenter study enrolling adult patients who underwent isolated tricuspid valve surgery (n = 406, 55 ± 16 y.o.; 56% female) at 13 international sites. Propensity weighted analysis was performed to compare groups (IE group n = 107 vs Not-IE group n = 299). RESULTS: No difference was found regarding the 30-day mortality (Group IE: 2.8% vs Group Not-IE = 6.8%; OR = 0.45) and major adverse events. Weighted cumulative incidence of cardiac death was significantly higher for patients with endocarditis (p = 0.01). The composite endpoint of cardiac death and reoperation at 6 years was reduced in the Group IE (63.2 ± 6.8% vs 78.9 ± 3.1%; p = 0.022). Repair strategy resulted in an increased late survival even in IE cases. CONCLUSIONS: Data from SURTRI study report acceptable 30-day results but significantly reduced late survival in the setting of endocarditis of the tricuspid valve. Multi-disciplinary approach, repair strategy and earlier treatment may improve outcomes.


Asunto(s)
Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Humanos , Femenino , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Pronóstico , Resultado del Tratamiento , Endocarditis/diagnóstico , Endocarditis/cirugía , Endocarditis/etiología , Reoperación , Muerte , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos
4.
J Cardiovasc Med (Hagerstown) ; 23(6): 406-413, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35645032

RESUMEN

AIMS: To compare early and late mortality of acute isolated tricuspid valve infective endocarditis (TVIE) treated with valve repair or replacement. METHODS: Patients who were surgically treated for TVIE from 1983 to 2018 were retrieved from the Italian Registry for Surgical Treatment of Valve and Prosthesis Infective Endocarditis. All the patients were followed up by means of phone interview or calling patient referral physicians or cardiologists. Kaplan-Meier method was used to assess late survival and survival free from TVIE recurrence with log-rank test for univariate comparison. The primary end points were early mortality (30 days after surgery) and long-term survival free from TVIE recurrence. RESULTS: A total of 4084 patients were included in the registry. Among them, 149 patients were included in the study. Overall, 77 (51.7%) underwent TV repair and 72 (48.3%) TV replacement. Early mortality was 9% (13 patients). Expected early mortality according to EndoSCORE was 12%. The TV repair showed lower mortality and major complication rate (7% and 16%), compared with TV replacement (11% and 25%), but statistical significance was not reached. Median follow-up was 19.1 years (14.3-23.8). Late deaths were 30 and IE recurrences were 5. No difference in cardiac survival free from IE was found between the two groups after 20 years (80 ±â€Š6% Repair Group vs 59 ±â€Š13% Replacement Group, P = 0.3). CONCLUSIONS: Overall results indicate that once surgically addressed, TVIE has a low recurrence rate and excellent survival, apparently regardless of the type of surgery used to treat it.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Endocarditis Bacteriana , Endocarditis , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Endocarditis/cirugía , Endocarditis Bacteriana/cirugía , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
5.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-35448903

RESUMEN

OBJECTIVES: The interest in isolated tricuspid valve disease has rapidly increased recently. However, clinical trials and registry data are rare in the surgical literature. This study aimed to describe the early and long-term outcomes of a real-world experience in isolated tricuspid procedures comparing repair and replacement strategies. METHODS: The Surgical-Tricuspid study is a multicentre retrospective study that enrolled adult patients who had undergone isolated tricuspid valve surgery at 13 international sites. Propensity score-matched analysis was used to compare repair versus replacement. RESULTS: A cohort of 426 patients was enrolled [mean age: 55 (16) years; 56% female]. After matching, 175 comparable pairs were analysed. Preoperative left ventricular ejection fraction was 55(9) vs 56(9) (P = 0.8) while moderate-severe tricuspid regurgitation was present in 95% of cases. The 30-day mortality rate was 4.0% vs 8.0% in the repair and replacement groups, respectively (P = 0.115). The rates of re-exploration for bleeding (6.9% vs 13.1% P = 0.050), permanent pacemaker implantation (5.1% vs 12.0%; P = 0.022) and blood transfusion (46% vs 62%; P = 0.002) were higher in the replacement group. Cumulative survival rates at 3, 5 and 7 years in the repair group were 84 (3)%, 75 (4)% and 56 (9)% vs 71 (4)%, 66 (5)% and 58 (5)% in the replacement group (P = 0.001) while cumulative incidence for reoperation at 10 years did not differ between groups [repair 10 (1)% vs replacement 9 (1)%; P = 0.469]. CONCLUSIONS: The data from the Surgical-Tricuspid study reported a high risk for patients undergoing tricuspid surgery. Isolated valve repair offered reduced early and late mortality with no difference regarding reoperation rate when compared with replacement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Adulto , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Función Ventricular Izquierda
6.
Artículo en Inglés | MEDLINE | ID: mdl-35381083

RESUMEN

OBJECTIVES: Although the intra-aortic balloon pump (IABP) has been the most widely adopted temporary mechanical support device in cardiac surgical patients, its use has declined. The current study aimed to evaluate the occurrence and predictors of early mortality and complication rates in contemporary cardiac surgery patients supported by an IABP. METHODS: A multicentre, retrospective analysis was performed of all consecutive cardiac surgical patients receiving perioperative balloon pump support in 8 centres between January 2010 to December 2019. The primary outcome was early mortality, and secondary outcomes were balloon-associated complications. A multivariable binary logistic regression model was applied to evaluate predictors of the primary outcome. RESULTS: The study cohort consisted of 2615 consecutive patients. The median age was 68 years [25th percentile 61, 75th percentile 75 years], with the majority being male (76.9%), and a mean calculated 30-day mortality risk of 10.0%. Early mortality was 12.7% (n = 333), due to cardiac causes (n = 266), neurological causes (=22), balloon-related causes (n = 5) and other causes (n = 40). A composite end point of all vascular complications occurred in 7.2% of patients, and leg ischaemia was observed in 1.3% of patients. The most important predictors of early mortality were peripheral vascular disease [odds ratio (OR) 1.63], postoperative dialysis requirement (OR 10.40) and vascular complications (OR 2.57). CONCLUSIONS: The use of the perioperative IABP proved to be safe and demonstrated relatively low complication rates, particularly for leg ischaemia. As such, we believe that specialists should not be held back to use this widely available treatment in high-risk cardiac surgical patients when indicated.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Contrapulsador Intraaórtico , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Humanos , Contrapulsador Intraaórtico/efectos adversos , Isquemia/etiología , Masculino , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
7.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35385588

RESUMEN

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Tricúspide , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Curva ROC , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Válvula Tricúspide/cirugía
8.
Ann Thorac Surg ; 113(2): 585-592, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33831392

RESUMEN

BACKGROUND: Isolated tricuspid valve (TV) surgery is a rare procedure generally considered at high risk for perioperative mortality and poor long-term outcomes. Surgical treatment can be performed with either an arrested heart (AH) or beating heart (BH) technique. The aim of this study was to compare the outcomes of isolated tricuspid surgery with 2 different approaches. METHODS: The Surgical-Tricuspid Study is a multicenter international retrospective study enrolling adult patients who underwent isolated TV procedures (n = 406; age 56 ± 16 years; 56% female) at 13 international sites. The AH and BH strategies were performed in 253 and 153 patients, respectively. Propensity score-matched analysis was used to compare groups. RESULTS: After matching, 129 pairs were obtained and analyzed. The 30-day mortality rate was 6.2% versus 5.0% in the AH and BH groups, respectively (P = .9). The rates of acute renal failure requiring replacement therapy (10% versus 3%; P = .02) and stroke (1.6% versus 0%; P = .08) were numerically higher in the AH group. The 6-year survival rate was 67% ± 6% versus 78% ± 5% in the AH and BH groups, respectively (P = .18), whereas freedom from cardiac death was 75% ± 5% versus 84% ± 4% (P = .21). The 6-year composite cardiac end point of cardiac death and reoperation rate was 60% ± 9% versus 86% ± 5% (P = .024) comparing AH-TV replacement and BH-TV repair groups. CONCLUSIONS: Isolated TV surgery performed with a BH strategy is a safe option and resulted in a trend of increased long-term survival and freedom from reoperation compared with the standard AH technique. Patients undergoing BH valve repair had the best long-term outcome.


Asunto(s)
Paro Cardíaco Inducido/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/epidemiología , Puntaje de Propensión , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo
9.
Semin Thorac Cardiovasc Surg ; 34(2): 453-461, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33979664

RESUMEN

Aim of this retrospective, multicenter study was to evaluate early and mid-term clinical and hemodynamic results of patients who underwent surgical aortic valve replacement (SAVR) with Intuity rapid-deployment bioprostheses (RDB) (Edwards Lifesciences, Irvine, CA). We analyzed data from the Italian Registry of Intuity Valve (INTU-ITA registry) that is a national, real-world and independent from the industry registry. Preoperative variables were defined according to EuroSCORE and postoperative outcomes according to Valve Academic Research Consortium (VARC). Survival distribution was evaluated using the Kaplan-Meier approach. A Cox-Proportional Hazard Model was employed to assess the effect of the covariates on patients' survival. The registry included 1687 patients from 23 centers (June 2012-September 2019). Aortic cross clamp time for isolated SAVR was 55 minutes (IQR: 45-70 minute). Postoperative pace-maker rate was 6.3%. At discharge transaortic peak and mean gradients were: 18 mm Hg (IQR: 14-23 mm Hg) and 10 mmHg (IQR: 8-13 mm Hg), respectively. Indexed effective orifice area was 1.10 cm2/m2 (IQR: 0.91-1.31 cm2/m2) and the incidence of severe patient-prosthesis mismatch was 0.6%. Hemodynamic data for all valve sizes remained stable during follow-up. Thirty-day overall mortality was 1.8% (30 patients), and at follow-up it was 5.3% (89 patients). Kaplan-Meier overall survival was 95.5% (94.3-96.7%); 90.7% (88.3-93.1%); 86.4% (82.6-90.4%) at 1, 3, and 5 years, respectively. Serum creatinine (HR: 1.36; 95%CI: 1.04-1.81; p = 0.0397) and cross-clamp time (HR: 1.01; 95%CI: 1.002-1.017; p = 0.0077) were identified as independent predictors of mortality. According to our data from the INTU-ITA registry, SAVR with RDB provides good early clinical and hemodynamic results that are confirmed at follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
10.
Eur J Cardiothorac Surg ; 61(3): 647-654, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-34363669

RESUMEN

OBJECTIVES: Commissural orientation <160° is a recognized risk factor for bicuspid aortic valve repair failure. Based on this observation, repairing this subtype of aortic valve by reorienting the 2 commissures at 180° has recently been proposed. METHODS: Nine porcine hearts with aortic annulus diameters of 25 mm were selected. A pathological model of a Sievers 1 bicuspid aortic valve was obtained by suturing the coaptation line between the left and right leaflets. Each heart underwent reimplantation procedures both in the native (120°) and the reoriented (180°) configuration. After the operation, each sample was tested on a pulse duplicator at rest (heart rate 60 beats per min) and with mild exercise (heart rate 90 beats per min) conditions. RESULTS: No statistically significant difference was noted in mean and peak transvalvular aortic gradients between the 2 configurations at rest (18.6 ± 5 vs 17.5 ± 4 for the mean aortic gradient; 42.8 ± 12.7 vs 36.3 ± 5.8 for the peak aortic gradient) but the group with the 120°-oriented commissures had significantly higher mean transaortic gradients compared to the group with the 180°-oriented commissures at initial exercise stress conditions (30.1 ± 9.1 vs 24.9 ± 3.8; p value 0.002). CONCLUSIONS: The 180° commissural reorientation of the asymmetrical bicuspid aortic valve does not improve the transvalvular aortic gradient in an acute model at rest conditions, but it could do so under stress situations. Even if it is surgically more complex and time-consuming, this approach could be a good strategy to improve long-term results, particularly in young patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Animales , Válvula Aórtica/patología , Insuficiencia de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Porcinos , Resultado del Tratamiento
11.
Eur J Cardiothorac Surg ; 61(2): 469-476, 2022 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-34718501

RESUMEN

OBJECTIVES: Papillary muscle rupture (PMR) is a rare but potentially fatal complication of acute myocardial infarction. The aim of this study was to analyse the patient characteristics and early outcomes of the surgical management of post-infarction PMR from an international multicentre registry. METHODS: Patients underwent surgery for post-infarction PMR between 2001 through 2019 were retrieved from database of the CAUTION study. The primary end point was in-hospital mortality. RESULTS: A total of 214 patients were included with a mean age of 66.9 (standard deviation: 10.5) years. The posteromedial papillary muscle was the most frequent rupture location (71.9%); the rupture was complete in 67.3% of patients. Mitral valve replacement was performed in 82.7% of cases. One hundred twenty-two patients (57%) had concomitant coronary artery bypass grafting. In-hospital mortality was 24.8%. Temporal trends revealed no apparent improvement in in-hospital mortality during the study period. Multivariable analysis showed that preoperative chronic kidney disfunction [odds ratio (OR): 2.62, 95% confidence interval (CI): 1.07-6.45, P = 0.036], cardiac arrest (OR: 3.99, 95% CI: 1.02-15.61, P = 0.046) and cardiopulmonary bypass duration (OR: 1.01, 95% CI: 1.00-1.02, P = 0.04) were independently associated with an increased risk of in-hospital death, whereas concomitant coronary artery bypass grafting was identified as an independent predictor of early survival (OR: 0.38, 95% CI: 0.16-0.92, P = 0.031). CONCLUSIONS: Surgical treatment for post-infarction PMR carries a high in-hospital mortality rate, which did not improve during the study period. Because concomitant coronary artery bypass grafting confers a survival benefit, this additional procedure should be performed, whenever possible, in an attempt to improve the outcome. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov: NCT03848429.


Asunto(s)
Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Anciano , Puente de Arteria Coronaria/efectos adversos , Mortalidad Hospitalaria , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/cirugía , Músculos Papilares/cirugía
12.
Medicina (Kaunas) ; 57(9)2021 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-34577832

RESUMEN

Background and Objectives: Aortic arch disease is still a high-risk surgical challenge despite major advances both in surgical and anesthesiological management. A combined surgical and endovascular approach has been proposed for aortic arch disease treatment to avoid hypothermia and circulatory arrest in high-risk patients. Materials and Methods: Between June 2004 and June 2021, 112 patients were referred to our department for aortic arch surgery; 38 (33.9%) patients underwent supra-aortic debranching and endovascular treatment. Of these, 21 (55%) patients underwent type I aortic arch hybrid debranching procedure and in 17 (45%) patients a type II aortic arch hybrid debranching procedure was performed. None of the patients were emergent. Results: No intra-operative deaths were recorded. In the type I aortic arch hybrid debranching patients' group, one patient died at home waiting the endovascular step, one developed ascending aortic dissection and another one developed a pseudoaneurysm at the site of the debranching at follow-up. In the type II aortic arch hybrid debranching patients' group, left carotid artery branch closure was detected at follow-up in one patient. Thirty day/in-hospital rates of adverse neurological events for both the surgical and endovascular procedures were 3% for minor stroke, with no permanent neurological deficit and 0% for permanent paraplegia/paraparesis. In 100% of the cases, the endovascular step succeeded and the type Ia endoleak rate was 0%. Conclusions: Hybrid arch surgery is a valuable option for aortic arch aneurysm treatment in patients with high surgical risk. The choice of aortic arch debranching between type I or type II is crucial and depends on anatomic and clinical patient characteristics. Further larger scale studies are needed to better define the advantages of these techniques.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Humanos , Estudios Retrospectivos , Factores de Riesgo , Stents , Resultado del Tratamiento
13.
Artículo en Inglés | MEDLINE | ID: mdl-34143578

RESUMEN

We propose a technique to minimize the neurological and systemic risks involved in rerouting the blood flow toward the brain in a "single remaining vessel" configuration with a 90% stenosis by means of complete hypothermic cerebral protection associated with normothermic systemic blood flow with a "restitutio ad integrum" of the supra-aortic trunks flow. The perfusion of the brain and the arms was almost completely separated from the systemic perfusion by the deployment 1 year before of a thoracic endoprosthesis in association with complete chronic occlusion of the brachiocephalic trunk and a functioning carotid-subclavian bypass. The Free Flow of the prosthesis, which acted as a hook, moved the calcium toward the left carotid ostium, creating a 90% stenosis with intermittent acute cerebral hypoperfusion and amaurosis. We achieved an optimal result: The patient was discharged on postoperative day 7 with no neurological problems and with patency and direct blood flow in all the supra-aortic trunks.


Asunto(s)
Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Prótesis Vascular/efectos adversos , Tronco Braquiocefálico/cirugía , Isquemia Encefálica/etiología , Isquemia Encefálica/cirugía , Estenosis Carotídea/cirugía , Femenino , Humanos , Persona de Mediana Edad
14.
J Card Surg ; 36(10): 3881-3883, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34145631

RESUMEN

In this case report, we describe how to recycle the left internal thoracic artery (LITA) when misused but not damaged. Eight years after a left anterior small thoracotomy followed by left anterior descending (LAD) stenting for STEMI in first postoperative day, a 67-years-old woman had an NSTEMI with angiographic evidence of intrastent re-stenosis with a perfectly patent LITA, harvested only from the fourth to the sixth intercostal space. During redo surgery, LITA was harvested as a pedicle from the anastomosis to the fourth intercostal space and primarily from the first to the fourth intercostal space. Special attention was paid at the level of the fourth intercostal space where the vessel was stuck to the sternum: a 15-blade was used being scissors or cautery too dangerous. At the end of harvesting, the LITA was full-length available for a new coronary anastomosis on LAD, distal to the previous one.


Asunto(s)
Arterias Mamarias , Anciano , Femenino , Humanos , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/cirugía , Esternón/cirugía , Toracotomía
15.
Ann Thorac Surg ; 112(4): 1186-1192, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33307071

RESUMEN

BACKGROUND: Left ventricular free-wall rupture (LVFWR) is an uncommon but serious mechanical complication of acute myocardial infarction. Surgical repair, though challenging, is the only definitive treatment. Given the rarity of this condition, however, results after surgery are still not well established. The aim of this study was to review a multicenter experience with the surgical management of post-infarction LVFWR and analyze the associated early outcomes. METHODS: Using the CAUTION (Mechanical Complications of Acute Myocardial Infarction: an International Multicenter Cohort Study) database, we identified 140 patients who were surgically treated for post-acute myocardial infarction LVFWR in 15 different centers from 2001 to 2018. The main outcome measured was operative mortality. Multivariate analysis was carried out by constructing a logistic regression model to identify predictors of postoperative mortality. RESULTS: The mean age of patients was 69.4 years. The oozing type of LVFWR was observed in 79 patients (56.4%), and the blowout type in 61 (43.6%). Sutured repair was used in the 61.4% of cases. The operative mortality rate was 36.4%. Low cardiac output syndrome was the main cause of perioperative death. Myocardial rerupture after surgery occurred in 10 patients (7.1%). Multivariable analysis revealed that preoperative left ventricular ejection fraction (P < .001), cardiac arrest at presentation (P = .011), female sex (P = .044), and the need for preoperative extracorporeal life support (P = .003) were independent predictors for operative mortality. CONCLUSIONS: Surgical repair of post-infarction LVFWR carries a high operative mortality. Female sex, preoperative left ventricular ejection fraction, cardiac arrest, and extracorporeal life support are predictors of early mortality.


Asunto(s)
Rotura Cardíaca Posinfarto/cirugía , Rotura Cardíaca/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Ventrículos Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
16.
J Cardiovasc Transl Res ; 14(3): 513-524, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32959169

RESUMEN

Transcatheter therapies are emerging for functional mitral regurgitation (FMR) treatment, however there is lack of pathological models for their preclinical assessment. We investigated the applicability of deer hearts for this purpose.8 whole deer hearts were housed in a pulsatile flow bench. At baseline, all mitral valves featured normal coaptation. The pathological state was induced by 60-minutes intraventricular constant pressurization. It caused mitral annulus dilation (antero-posterior diameter increase from 31.8 ± 5.6 mm to 39.5 ± 4.9 mm, p = 0.001), leaflets tethering (maximal tenting height increase from 7.3 ± 2.5 mm to 12.7 ± 3.4 mm, p < 0.001) and left ventricular diameter increase (from 67.8 ± 7.5 mm to 79.4 ± 6.5 mm, p = 0.004). These geometrical reconfigurations led to restricted mitral valve leaflets motion and leaflet coaptation loss. Preliminary feasibility assessment of two FMR treatments was performed in the developed model.Deer hearts showed ability to dilate under constant pressurization and have potential to be used for realistic preclinical research of novel FMR therapies. Graphical abstract figure legend: Deer heart mitral valve fiberscopic and echocardiographic images in peak systole at baseline and after inducing the pathological conditions representing functional mitral regurgitation. In the pathological conditions lack of coaptation between the leaflets, enlargement of the antero-posterior distance (red dashed line) and the left ventricular diameter (orange dashed line) were observed.


Asunto(s)
Hemodinámica , Insuficiencia de la Válvula Mitral/fisiopatología , Válvula Mitral/fisiopatología , Animales , Ciervos , Modelos Animales de Enfermedad , Ecocardiografía Tridimensional , Tecnología de Fibra Óptica , Preparación de Corazón Aislado , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Función Ventricular Izquierda
17.
Eur J Cardiothorac Surg ; 59(3): 674-679, 2021 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-33236049

RESUMEN

OBJECTIVES: The Florida-sleeve is a valve-sparing technique that causes minimal interference to leaflet kinematics and aortic root dynamism. The aim of this in vitro study was to evaluate the effects of the Florida-sleeve and Yacoub techniques on aortic leaflet kinematics. METHODS: Two groups of 6 whole porcine hearts were treated with either the Florida-sleeve technique or the Yacoub technique and tested in a pulsatile loop. Valve fluid dynamics, coronary flow analysis and valve echocardiograms were performed both before and after the procedures. RESULTS: Both procedures showed no difference in rapid valve opening time as compared with their respective baseline values. The Florida-sleeve procedure showed a shorter slow closing time (192 ± 19 ms vs baseline 244 ± 14 ms, P = 0.016) and increased slow closing velocity (-1.5 ± 0.4 cm/s vs baseline -0.8 ± 0.4 cm/s, P = 0.038). In the rapid valve closing phase, the Yacoub procedure showed a trend towards slower closing valve velocity (-16 ± 9 cm/s vs baseline -25 ± 9 cm/s, P = 0.07). The Yacoub procedure showed larger leaflet displacement at the end of the slow valve closing time that was 2.0 ± 0.5 cm vs baseline 1.5 ± 0.3 cm, P = 0.044. When comparing the Florida-sleeve and Yacoub procedures, the former showed statistically significant shorter slow valve closing time (P = 0.017). CONCLUSIONS: This study showed that the Florida-sleeve technique alters the slow closing phase of the aortic valve leaflet kinematics when compared with both the normal baseline and Yacoub procedure, while the latter showed a larger leaflet displacement before the rapid closing valve phase.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Animales , Aorta , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Fenómenos Biomecánicos , Florida , Porcinos
18.
Ann Thorac Surg ; 111(6): 1916-1922, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33039363

RESUMEN

BACKGROUND: The aim of this multicenter retrospective study was to compare early and midterm clinical and hemodynamic results of aortic valve replacement with rapid-deployment bioprostheses performed through conventional full-sternotomy vs mini-sternotomy. METHODS: Data from the Italian multicenter registry of aortic valve replacement with rapid-deployment bioprostheses (INTU-ITA registry) were analyzed. Patients were divided into 2 groups: full sternotomy (FS) and ministernotomy (MS). Primary endpoint was the comparison of early and midterm mortality. Secondary endpoints were: comparison of intraoperative variables, complications, and hemodynamic performance. A propensity score weighting approach was used for data analysis. RESULTS: A total of 1057 patients were analyzed: 435 (41.2%) and 622 (58.8%) in group FS and MS, respectively. Thirty-day mortality was 1.6% and 0.6% in FS and MS groups, respectively (P = .074). cardiopulmonary bypass time was 78.5 minutes and 83 minutes in FS and MS groups, respectively (P = .414). In the overall cohort, the incidence of intraoperative complications and of device success was 3.8% (40 patients) and 95.9% (1014 patients), respectively, with no significant differences between groups. Survival at 1, 3, and 5 years was 94.1%, 98.1%, 88.5% and 91.8%, 85.2%, and 84.8% in FS and MS groups, respectively (P = .412). The 2 groups showed similar postoperative gradients (median mean gradient, FS: 10.0 mm Hg, MS: 11.0 mm Hg; P = .170) and also similar incidence of patient-prosthesis mismatch (FS: 7%, MS: 6.4%, P = .647). CONCLUSIONS: According to our data, rapid-deployment bioprostheses allow the performance of minimally invasive aortic valve replacement with similar surgical times and similar clinical and hemodynamic outcomes to conventional surgery and should be considered the first choice in these procedures.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/epidemiología , Esternotomía/métodos , Anciano , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Italia , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Tempo Operativo , Puntaje de Propensión , Sistema de Registros , Estudios Retrospectivos , Esternotomía/efectos adversos , Tasa de Supervivencia , Resultado del Tratamiento
19.
Int J Cardiol ; 324: 38-43, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33022288

RESUMEN

OBJECTIVE: The aim of this multicenter study was to evaluated whether cold or warm cardioplegia are associated with postoperative atrial fibrillation (POAF) and the prognostic role of the latter on early stroke and neurological mortality. METHOD: This was a retrospective analysis of prospective collected data from 9 cardiac centers in Italy and the United States including patients undergoing surgery between 2010 and 2018. From the 9 institutional databases, 17,231 patients underwent isolated CABG on-pump, using either warm cardioplegia (n = 7730) or cold cardioplegia (n = 9501); among the latter group blood and crystalloid cardioplegia were used in 691 and 8810 patients, respectively. After matching, two pairs of 4162 patients (overall cohort 8324) were analyzed. RESULTS: In matched population, the rate of POAF was 18% (1472 cases), 15% (608) in warm group versus 21% (864) in cold group (p < 0.001). Multivariable analysis confirmed that cold cardioplegia was associated with higher rate of POAF, along with age, hypercholesterolemia, LVEF, reoperation, preoperative IABP, previous stroke, cardiopulmonary and cross-clamp. Moreover, cold cardioplegia as well as POAF increased the rate of postoperative stroke as well as early mortality and neurological mortality Propensity-weighted cohort included 11,830 (70%) patients out of 17,231. After adjustment, both cold blood and cold crystalloid cardioplegia negatively influenced POAF, stroke and neurological mortality. CONCLUSIONS: Warm cardioplegia may reduce the rate of POAF in CABG patients with respect to cold cardioplegia, either blood or crystalloid. This has a prognostic impact on postoperative stroke and neurological mortality.


Asunto(s)
Fibrilación Atrial , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Puente de Arteria Coronaria/efectos adversos , Paro Cardíaco Inducido/efectos adversos , Humanos , Italia , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Estudios Retrospectivos
20.
Ann Thorac Surg ; 111(3): 845-852, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32818539

RESUMEN

BACKGROUND: Minimally invasive direct coronary artery bypass (MIDCAB) is a well-established, low-impact surgical procedure for revascularization of the left descending coronary artery with the left internal mammary artery. This study aimed to evaluate safety, overall survival, and freedom from major adverse cardiocerebral-related events (MACCE) after 20 years of MIDCAB. METHODS: This study retrospectively collected a series of 141 patients who underwent MIDCAB between 1997 and 2017, to assess long-term outcome. A total of 133 patients who underwent revascularization of the left descending coronary artery with the left mammary artery through a full median sternotomy were analyzed. RESULTS: Actuarial survival rates on a Kaplan-Meier curve were 100%, 95%, 90%, 83%, and 70% at 1, 5, 10, 15, and 20 years, respectively. Freedom from MACCE, defined as myocardial infarction, stroke, and cardiac death, was 97%, 90%, 79%, 75%, and 61% at 1,5,10,15, and 20 years, respectively. At Cox multivariable analysis, age, cancer, and chronic renal insufficiency were found to be independent predictors affecting long-term survival, with a hazard ratio of 1.12 (P = .007), 17.63 (P < .001), and 5.16 (P = .03), respectively. The MIDCAB group showed a significantly shorter hospital length of stay and significantly lower rates of blood transfusions, cardiac-related events, and all-cause events compared with the full sternotomy group (P = .02 and P = .001, respectively). CONCLUSIONS: The very long-term clinical outcome of MIDCAB is satisfactory in terms of survival and freedom from MACCE. MIDCAB significantly reduces hospital length of stay and blood transfusions when compared with full sternotomy bypass surgery on the left descending coronary artery and appears to improve prognosis in terms of cardiac-related events and all-cause events effectively.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Predicción , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...