Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38513110

RESUMEN

AIMS: Catheter ablation (CA) of post-ablation left atrial tachycardias (LATs) can be challenging. So far, pulsed field ablation (PFA) has not been compared to standard point-by-point radiofrequency current (RFC) energy for LAT ablation. To compare efficacy of PFA vs. RFC in patients undergoing CA for LAT. METHODS AND RESULTS: Consecutive patients undergoing LAT-CA were prospectively enrolled (09/2021-02/2023). After electro-anatomical high-density mapping, ablation with either a pentaspline PFA catheter or RFC was performed. Patients were matched 1:1. Ablation was performed at the assumed critical isthmus site with additional ablation, if necessary. Right atrial tachycardia (RAT) was ablated with RFC. Acute and chronic success were assessed. Fifty-six patients (n = 28 each group, age 70 ± 9 years, 75% male) were enrolled.A total of 77 AT (n = 67 LAT, n = 10 RAT; 77% macroreentries) occurred with n = 32 LAT in the PFA group and n = 35 LAT in the RFC group. Of all LAT, 94% (PFA group) vs. 91% (RFC group) successfully terminated to sinus rhythm or another AT during ablation (P = 1.0). Procedure times were shorter (PFA: 121 ± 41 vs. RFC: 190 ± 44 min, P < 0.0001) and fluoroscopy times longer in the PFA group (PFA: 15 ± 9 vs. RFC: 11 ± 6 min, P = 0.04). There were no major complications. After one-year follow-up, estimated arrhythmia free survival was 63% (PFA group) and 87% (RFC group), [hazard ratio 2.91 (95% CI: 1.11-7.65), P = 0.0473]. CONCLUSION: Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up. Future catheter designs and optimization of the electrical field may further improve practicability and efficacy of PFA for LAT.

2.
Thromb Haemost ; 2024 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-38555641

RESUMEN

OBJECTIVE AND BACKGROUND: Data on incidence of in-hospital pulmonary embolisms (PE) after catheter ablation (CA) are scarce. To gain further insights, we sought to provide new findings through case-based analyses of administrative data. METHODS: Incidences of PE after CA of supraventricular tachycardias (SVT), atrial fibrillation (AF), atrial flutter (AFlu), and ventricular tachycardias (VT) in three German tertiary centers between 2005 and 2020 were determined and coded by the G-DRG (German Diagnosis Related Groups System) and OPS (German Operation and Procedure Classification) systems. An administrative search was performed with a consecutive case-based analysis. RESULTS: Overall, 47,344 ablations were analyzed (10,037 SVT; 28,048 AF; 6,252 AFlu; 3,007 VT). PE occurred in 14 (0.03%) predominantly female (n = 9; 64.3%) patients with a mean age of 55.3 ± 16.9 years, body mass index 26.2 ± 5.1 kg/m2, and left ventricular ejection fraction of 56 ± 13.6%. PE incidences were 0.05% (n = 5) for SVT, 0.02% (n = 5) for AF, and 0.13% (n = 4) for VT ablations. No patient suffered PE after AFlu ablation. Five patients (35.7%) with PE after CA had no prior indication for oral anticoagulation (OAC). Preprocedural international normalized ratio in PE patients was 1.2 ± 0.5. Most patients with PE following CA presented with symptoms the day after the procedure (n = 9) after intraprocedural heparin application of 12,943.2 ± 5,415.5 IU. PE treatment included anticoagulation with either phenprocoumon (n = 5) or non-vitamin K-dependent OAC (n = 9). Two patients with PE died after VT/AF ablation, respectively. The remaining patients were discharged without sequels. CONCLUSION: Over a 15-year period, incidence of PE after ablation is low, particularly low in patients with ablation for AF/AFlu. This is most likely due to stricter anticoagulation management in these patients compared with those receiving SVT/VT ablation procedures and could argue for continuation of OAC prior to ablation. Optimizing periprocedural anticoagulation management should be subject of further prospective trials.

3.
J Cardiovasc Electrophysiol ; 35(1): 162-170, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38009545

RESUMEN

INTRODUCTION: Pulsed field ablation (PFA) represents a novel, nonthermal energy modality that can be applied for single-shot pulmonary vein isolation (PVI) in atrial fibrillation (AF). Comparative data with regard to deep sedation to established single-shot modalities such as cryoballoon (CB) ablation are scarce. The aim of this study was to compare a deep sedation protocol in patients receiving PVI with either PFA or CB. METHODS: Prospective, consecutive AF patients undergoing PVI with a pentaspline PFA catheter were compared to a retrospective CB-PVI cohort of the same timeframe. Study endpoints were the requirements of analgesics, cardiorespiratory stability, and sedation-associated complications. RESULTS: A total of 100 PVI patients were included (PFA n = 50, CB n = 50, mean age 66 ± 10.6, 61% male patients, 65% paroxysmal AF). Requirement of propofol, midazolam, and sufentanyl was significantly higher in the PFA group compared to CB [propofol 0.14 ± 0.04 mg/kg/min in PFA vs. 0.11 ± 0.04 mg/kg/min in CB (p = .001); midazolam 0.00086 ± 0.0004 mg/kg/min in PFA vs. 0.0006295 ± 0.0003 mg/kg/min in CB (p = .002) and sufentanyl 0.0013 ± 0.0007 µg/kg/min in PFA vs. 0.0008 ± 0.0004 µg/kg/min in CB (p < .0001)]. Sedation-associated complications did not differ between both groups (PFA n = 1/50 mild aspiration pneumonia, CB n = 0/50, p > .99). Nonsedation-associated complications (PFA: n = 2/50, 4%, CB: n = 1/50, 2%, p > .99) and procedure times (PFA 75 ± 31, CB 84 ± 32 min, p = .18) did not differ between groups. CONCLUSIONS: PFA is associated with higher sedation and especially analgesia requirements. However, the safety of deep sedation does not differ to CB ablation.


Asunto(s)
Analgesia , Fibrilación Atrial , Criocirugía , Propofol , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Midazolam/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos
4.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38102318

RESUMEN

AIMS: In-hospital complications of catheter ablation for atrial fibrillation (AF), atrial flutter (AFL), and ventricular tachycardia (VT) may be overestimated by analyses of administrative data. METHODS AND RESULTS: We determined the incidences of in-hospital mortality, major bleeding, and stroke around AF, AFL, and VT ablations in four German tertiary centres between 2005 and 2020. All cases were coded by the G-DRG- and OPS-systems. Uniform code search terms were applied defining both the types of ablations for AF, AFL, and VT and the occurrence of major adverse events including femoral vascular complications, iatrogenic tamponade, stroke, and in-hospital death. Importantly, all complications were individually reviewed based on patient-level source records. Overall, 43 031 ablations were analysed (30 361 AF; 9364 AFL; 3306 VT). The number of ablations/year more than doubled from 2005 (n = 1569) to 2020 (n = 3317) with 3 times and 2.5 times more AF and VT ablations in 2020 (n = 2404 and n = 301, respectively) as compared to 2005 (n = 817 and n = 120, respectively), but a rather stable number of AFL ablations (n = 554 vs. n = 612). Major peri-procedural complications occurred in 594 (1.4%) patients. Complication rates were 1.1% (n = 325) for AF, 1.0% (n = 95) for AFL, and 5.3% (n = 175) for VT. With an increase in complex AF/VT procedures, the overall complication rate significantly increased (0.76% in 2005 vs. 1.81% in 2020; P = 0.004); but remained low over time. Following patient-adjudication, all in-hospital cardiac tamponades (0.7%) and strokes (0.2%) were related to ablation. Major femoral vascular complications requiring surgical intervention occurred in 0.4% of all patients. The in-hospital mortality rate adjudicated to be ablation-related was lower than the coded mortality rate: AF: 0.03% vs. 0.04%; AFL: 0.04% vs. 0.14%; VT: 0.42% vs. 1.48%. CONCLUSION: Major adverse events are low and comparable after catheter ablation for AFL and AF (∼1.0%), whereas they are five times higher for VT ablations. In the presence of an increase in complex ablation procedures, a moderate but significant increase in overall complications from 2005-20 was observed. Individual case analysis demonstrated a lower than coded ablation-related in-hospital mortality. This highlights the importance of individual case adjudication when analysing administrative data.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Accidente Cerebrovascular , Taquicardia Ventricular , Humanos , Mortalidad Hospitalaria , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/cirugía , Hospitales , Accidente Cerebrovascular/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
5.
J Clin Med ; 12(19)2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37834948

RESUMEN

BACKGROUND: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. OBJECTIVE: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. METHODS: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. RESULTS: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62-95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. CONCLUSION: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.

6.
J Urban Health ; 100(4): 811-833, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37535302

RESUMEN

Infrastructure upgrading projects are a key element in enhancing the livelihood of residents in slum areas. These projects face significant constructability challenges common to dense-urban construction coupled with the unique socioeconomic challenges of operating in slums. This research focuses on sanitation network upgrading projects in slum areas and proposes a novel methodology capable of (1) accounting for the unique constructability challenges for these projects, (2) accelerating the provision of sanitation services, and (3) optimizing construction decisions. The key contribution of this research to the body of knowledge is in developing a comprehensive construction planning framework capable of achieving these three objectives. The proposed framework focuses specifically on sewer lines upgrading within the larger sanitation networks upgrading projects. This framework consists of five main models that can guide planners in selecting the appropriate equipment sizes, trench system configuration, and optimal equipment routing, in addition to identifying all possible execution sequences along with the corresponding construction cost and duration of each sequence. Most notably, this framework proposes an approach to assess the serviceability of different construction plans measured by how fast sanitary services can be provided to slum dwellers. A multi-objective, genetic algorithms optimization model is developed to identify the optimal construction plans that accelerate the sanitary service provision to residents while minimizing construction costs. A real-world example is presented to demonstrate the model capabilities in optimizing construction plans.


Asunto(s)
Áreas de Pobreza , Saneamiento , Humanos
7.
Europace ; 25(1): 130-136, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36006798

RESUMEN

AIMS: The incidence of in-hospital post-interventional complications and mortality after ablation of supraventricular tachycardia (SVT) vary among the type of procedure and most likely the experience of the centre. As ablation therapy of SVT is progressively being established as first-line therapy, further assessment of post-procedural complication rates is crucial for health care quality. METHODS AND RESULTS: We aimed at determining the incidence of in-hospital mortality and bleeding complications from SVT ablations in German high-volume electrophysiological centres between 2005 and 2020. All cases were registered by the German Diagnosis Related Groups-and the German Operation and Procedure Classification (OPS) system. A uniform search for SVT ablations from 2005 to 2020 with the same OPS codes defining the type of ablation/arrhythmia as well as the presence of a vascular complication, cardiac tamponade, and/or in-hospital death was performed. An overall of 47 610 ablations with 10 037 SVT ablations were registered from 2005 to 2020 among three high-volume centres. An overall complication rate of 0.5% (n = 38) was found [median age, 64; ±15 years; female n = 26 (68%)]. All-cause mortality was 0.02% (n = 2) and both patients had major prior co-morbidities precipitating a lethal outcome irrespective of the ablation procedure. Vascular complications occurred in 10 patients (0.1%), and cardiac tamponade was detected in 26 cases (0.3%). CONCLUSION: The present case-based analysis shows an overall low incidence of in-hospital complications after SVT ablation highlighting the overall very good safety profile of SVT ablations in high-volume centres. Further prospective analysis is still warranted to guarantee continuous quality control and optimal patient care.


Asunto(s)
Taponamiento Cardíaco , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Femenino , Persona de Mediana Edad , Masculino , Mortalidad Hospitalaria , Taponamiento Cardíaco/epidemiología , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/cirugía , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
8.
Medicina (Kaunas) ; 58(12)2022 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-36556902

RESUMEN

Background and Objectives: Selective pulmonary vein (PV) angiography has been established as the gold standard for PV visualization in cryoballoon (CB)-based pulmonary vein isolation (PVI). We sought to simplify this approach to reduce procedural complexity and radiation exposure. Materials and Methods: Patients with paroxysmal and recently diagnosed persistent AF undergoing CB-based PVI from January 2015 to December 2017 were retrospectively analyzed. Patients underwent either selective PV angiography or conventional left atrial (LA) angiography for PV visualization. Results: A total of 336 patients were analyzed. A total of 87 patients (26%) received PV angiography and 249 (74%) LA angiography. LA angiography required fewer cine-sequences for PV visualization, translating into a significant reduction in procedure duration, fluoroscopy time and dose area product. Additionally, less contrast medium was utilized. PV occlusion by the CB, CB temperature and time to isolation showed no significant differences. The number of CB applications and total application time (LA angiography: 1.4 ± 0.02 vs. PV Angiography: 1.6 ± 0.05; p < 0.0001; LA angiography: 297.9 ± 4.62 vs. PV-Angiography: 348.9 ± 11.03; p < 0.001, respectively) per vein were slightly but significantly higher in the PV angiography group. We observed no difference in late AF recurrence (24.7% LA angiography vs. 21.3% PV angiography; p = 0.2657). Conclusions: A simplified protocol, using LA angiography for PV visualization, entails a reduction in procedure time and radiation exposure while equally maintaining procedural efficiency and safety in both groups.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Estudios Retrospectivos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/métodos , Recurrencia
9.
Medicina (Kaunas) ; 58(11)2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36422224

RESUMEN

Background: Atrial fibrillation is the most common arrhythmia and has been described as driver of cardiovascular morbidity and risk factor for cardiac device-related complications, as well as in transvenous lead extraction (TLE). Objectives: Aim of this study was to characterize the procedural outcome and risk-factors of patients with atrial fibrillation (AF) undergoing TLE. Methods: We performed a subgroup analysis of all AF patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) database. Predictors for all-cause mortality were assessed. Results: A total number of 510 patients with AF were identified with a mean age of 74.0 ± 10.3 years. Systemic infection (38.4%) was the leading cause for TLE, followed by local infection (37.5%) and lead dysfunction (20.4%). Most of the patients (45.9%) presented with pacemaker systems to be extracted. The total number of leads was 1181 with a 2.3 ± 0.96 leads/patient. Clinical procedural success was achieved in 97.1%. Occurrence of major complications was 1.8% with a procedure-related mortality of 1.0%. All-cause mortality was high with 5.9% and septic shock being the most common cause. Systemic device infection (OR: 49.73; 95% CI: 6.56−377.09, p < 0.001), chronic kidney disease (CKD; OR: 2.67; 95% CI: 1.01−7.03, p = 0.048) and a body mass index < 21 kg/m2 (OR: 6.6; 95% CI: 1.68−25.87, p = 0.007) were identified as independent predictors for all-cause mortality. Conclusions: TLE in AF patients is effective and safe, but in patients with systemic infection the mortality due to septic shock is high. Systemic infection, CKD and body mass index <21 kg/m2 are risk factors for death in patient with AF undergoing TLE.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Cardiopatías , Insuficiencia Renal Crónica , Choque Séptico , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Remoción de Dispositivos/efectos adversos , Sistema de Registros , Cardiopatías/etiología , Rayos Láser , Insuficiencia Renal Crónica/etiología
10.
J Cardiovasc Electrophysiol ; 33(12): 2431-2443, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36259717

RESUMEN

INTRODUCTION: Catheter-ablation (CA) of consecutive left atrial tachycardias (LAT) can be challenging. Pulsed field ablation (PFA) yields a novel nonthermal CA technology for treatment of atrial fibrillation (AF). There is no data regarding PFA of LAT. This study sought to investigate PFA of consecutive LAT following prior CA of AF. METHODS: Consecutive patients with LAT underwent ultrahigh-density (UHDx) mapping. Subsequent to identification of the AT mechanism, PFA was performed at the assumed critical sites for LAT maintenance. Continuous ablation lines were performed if required and evaluated with pre- and post-PFA HDx-mapping. RESULTS: Fifteen patients (age 70 ± 10, male 73%) who underwent 3.6 ± 2 prior AF-CA procedures were included. The total mean procedure and fluoroscopy times were 141 ± 43 and 18 ± 10 min, respectively. All 19 of 19 (100%) LAT were successfully ablated with PFA. Two AT located at the right atria required RF-ablation. LAT were identified as localized reentry (n = 1) and macro-reentry LAT (n = 18) and targeted with PFA. All LAT terminated with PFA either to sinus rhythm (9/15) or a secondary AT (6/15 and subsequently to SR); 63% (12/19) terminated with the first PFA-application. All lines (13 roof, 11 anterior, 1 mitral) were blocked. LA-posterior-wall isolation (LAPWI) was successfully achieved when performed (10/10). AF/AT free survival was 80% (12/15) after 153 [88-207] days of follow-up. No procedure-related complications occurred. CONCLUSION: PFA of consecutive LAT is feasible and safe. Successful creation of ablation lines and LAPWI can be achieved in a short time. PFA may offer the opportunity for effective ablation of atrial arrhythmias beyond AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Taquicardia , Resultado del Tratamiento , Venas Pulmonares/cirugía
11.
EPMA J ; 13(3): 451-460, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36061830

RESUMEN

Background: Surgical replacement of the aortic root is the only intervention that can prevent aortic dissection and cardiovascular death in Marfan syndrome (MFS). However, in some individuals, MFS also causes sleep apnea. If sleep apnea predicts cardiovascular death, a new target for predictive, preventive, and personalized medicine (PPPM) may emerge for those individuals with MFS who have sleep apnea. Methods: This is an investigator-initiated study with long-term follow-up data of 105 individuals with MFS. All individuals were screened for sleep apnea regardless of symptoms. Cardiovascular death served as a primary endpoint, and aortic events as a secondary outcome. Results: Sleep apnea with an apnea-hypopnea index (AHI) > 5/h was observed in 21.0% (22/105) with mild sleep apnea in 13% (14/105) and moderate to severe sleep apnea in 7.6% (8/105). After a median follow-up of 7.76 years (interquartile range: 6.84, 8.41), 10% (10/105) had died, with cardiovascular cause of death in 80% (8/10). After adjusting for age and body mass index (BMI), the AHI score emerged as an independent risk factor for cardiovascular death (hazard ratio 1.712, 95% confidence interval [1.061-2.761], p = 0.0276). The secondary outcome of aortic events occurred in 33% (35/105). There was no effect of the AHI score on aortic events after adjusting for age and BMI (hazard ratio 0.965, 95% confidence interval [0.617-1.509]), possibly due to a high number of patients with prior aortic surgery. Interpretation: Sleep apnea is emerging as an independent predictor of cardiovascular death in MFS. It seems mandatory to screen all individuals with MFS for sleep apnea and to include these individuals, with both MFS and sleep apnea, in further studies to evaluate the impact of preventive measures with regard to cardiovascular death. Supplementary Information: The online version contains supplementary material available at 10.1007/s13167-022-00291-4.

12.
J Cardiovasc Electrophysiol ; 33(3): 345-356, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34978360

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrofisiología Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
14.
Eur Heart J Case Rep ; 5(7): ytab245, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34240004

RESUMEN

BACKGROUND: Cryoballoon-based pulmonary vein isolation (cbPVI) is a standardized treatment of atrial fibrillation. In complex anatomies, radiofrequency ablation (rfPVI) is usually preferred. We describe the first cbPVI in a rare patient with SI and levocardia. CASE SUMMARY: A 41-year-old male patient with paroxysmal atrial fibrillation was referred to our clinic after a previous, unsuccessful cbPVI procedure. Observation of an atypical lead-wire position due to an abnormal anatomy of the inferior vena cava led to its initial termination. A subsequent thoraco-abdominal computed tomography revealed situs inversus abdominalis and levocardia and the procedure was re-attempted in our clinic. Transseptal puncture (TSP) was guided via transoesophageal echocardiography and fluoroscopy, using a SL0-Sheath and a standard BRK-needle. Advancement of the sheath initially failed but after additional dilatation with an Inoue® dilator, transseptal passage of the sheath was successful. Due to the unusual antero-cranial TSP, the septal pulmonary veins (PV) contrasted poorly. After repeat TSP, a steerable FlexCath Advance® sheath was introduced into the left atrium using an Amplatz Super Stiff® guidewire. Subsequently, all PV were intubated with the Achieve® catheter, over which a 2nd generation cryoballoon was introduced. Despite the practical challenges in this case, all PV were isolated. DISCUSSION: The main challenges include the achievement of transseptal access and manipulation of the cryoballoon to achieve a patent seal of the pulmonary veins. cbPVI eliminates the need for constant re-positioning of the ablation catheter and might facilitate the creation of durable lesions under such difficult anatomical conditions.

15.
Europace ; 22(10): 1502-1508, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32830253

RESUMEN

AIMS: S100B, a well-known damage-associated molecular pattern protein is released acutely by central and peripheral nerves and upon concomitant denervation in pulmonary vein isolation (PVI). We aimed to investigate whether the ablation technique used for PVI impacts S100B release in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: The study population consisted of 73 consecutive patients (age: 62.7 ± 10.9 years, 54.8% males) undergoing first-time PVI with either radiofrequency (RF; n = 30) or cryoballoon (CB; n = 43) for paroxysmal AF. S100B determined from venous plasma samples taken immediately before and after PVI increased from 33.5 ± 1.8 to 91.1 ± 5.3 pg/mL (P < 0.0001). S100B release in patients undergoing CB-PVI was 3.9 times higher compared to patients with RF-PVI (ΔS100B: 21.1 ± 2.7 vs. 83.1 ± 5.2 pg/mL, P < 0.0001). During a mean follow-up of 314 ± 186 days, AF recurrences were observed in 18/71 (25.4%) patients (RF-PVI: n = 9/28, CB-PVI: n = 9/43). Univariate Cox regression analysis indicated that an increase in S100B was associated with higher freedom from AF in follow-up (hazard ratio per 10 pg/mL release of S100B: 0.83; 95% confidence interval: 0.72-0.95; P = 0.007). CONCLUSION: The ablation technique used for PVI has an impact on the release of S100B, a well-established biomarker for neural damage.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Anticoagulantes , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Biomarcadores , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Subunidad beta de la Proteína de Unión al Calcio S100 , Resultado del Tratamiento
16.
PLoS One ; 15(6): e0235132, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32584880

RESUMEN

BACKGROUND: Phrenic nerve injury (PNI) remains one of the most frequent complications during cryoballoon-based pulmonary vein isolation (CB-PVI). Since its introduction in 2013, the use of compound motor action potential (CMAP) for the prevention of PNI during CB-PVI is increasing; however, systematic outcome data are sparse. METHODS: The CMAP technique was applied in conjunction with abdominal palpation during pacing manoeuvres (10 mV, 2 ms) from the superior vena cava for 388 consecutive patients undergoing CB-PVI between January 2015 and May 2017 at our tertiary arrhythmia centre. Cryoablation was immediately terminated when CMAP amplitude was reduced by 30%. RESULTS: Reductions in CMAP amplitude were observed in 16 (4%) of 388 patients during isolation of the right veins. Of these, 11 (69%) patients did not manifest a reduction in diaphragmatic excursions. The drop in CMAP amplitude was observed in 10 (63%) patients during ablation of the right superior pulmonary veins (PVs) and in 7 (44%) patients during ablation of the right inferior PVs. Postprocedural persistent PNI was observed in three of four patients for a duration of 6 months, with one of these patients remaining symptomatic at the 24-month follow-up. One of the four patients was lost to long-term follow-up. CONCLUSIONS: All PNIs occurred during right-sided CB-PVI and were preceded by a reduction in CMAP amplitude. Thus, the standardized use of CMAP surveillance during CB-PVI is easily applicable, reliable and compared with other studies, results in a lower number of PNIs.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Criocirugía/efectos adversos , Monitorización Neurofisiológica Intraoperatoria , Nervio Frénico , Venas Pulmonares , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Nervio Frénico/lesiones , Nervio Frénico/fisiopatología , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía
17.
Disasters ; 37(3): 489-515, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23551231

RESUMEN

The widespread destruction that follows large-scale natural disasters, such as Hurricane Katrina in August 2005, challenges the efficacy of traditional temporary housing methods in providing adequate solutions to housing needs. Recognising these housing challenges, the Congress of the United States allocated, in 2006, USD 400 million to the Department of Homeland Security to support Alternative Housing Pilot Programs, which are intended to explore the possibilities of providing permanent and affordable housing to displaced families instead of traditional temporary housing. This paper presents a new methodology and optimisation model to identify the optimal configurations of post-shelter housing arrangements to maximise the overall net socioeconomic benefit. The model is capable of quantifying and optimising the impacts of substituting temporary housing with alternative housing on the social and economic welfare of displaced families as well as the required additional costs of doing so. An application example is presented to illustrate the use of the model and its capabilities.


Asunto(s)
Tormentas Ciclónicas , Desastres , Eficiencia Organizacional , Vivienda , Bienestar Social , Humanos , Modelos Organizacionales , Proyectos Piloto , Estados Unidos
18.
Disasters ; 34(3): 865-83, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20345460

RESUMEN

In the aftermath of catastrophic natural disasters such as hurricanes, tsunamis and earthquakes, emergency management agencies come under intense pressure to provide temporary housing to address the large-scale displacement of the vulnerable population. Temporary housing is essential to enable displaced families to reestablish their normal daily activities until permanent housing solutions can be provided. Temporary housing decisions, however, have often been criticized for their failure to fulfil the socioeconomic needs of the displaced families within acceptable budgets. This paper presents the development of (1) socioeconomic disruption metrics that are capable of quantifying the socioeconomic impacts of temporary housing decisions on displaced populations; and (2) a robust multi-objective optimization model for temporary housing that is capable of simultaneously minimizing socioeconomic disruptions and public expenditures in an effective and efficient manner. A large-scale application example is optimized to illustrate the use of the model and demonstrate its capabilities ingenerating optimal plans for realistic temporary housing problems.


Asunto(s)
Planificación en Desastres/organización & administración , Desastres , Vivienda , Personas con Mala Vivienda , Refugiados , Sistemas de Socorro/organización & administración , Algoritmos , Toma de Decisiones , Humanos , Modelos Estadísticos , Bienestar Social , Factores Socioeconómicos , Factores de Tiempo , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...