Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Front Neurol ; 15: 1374737, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38651109

RESUMEN

Introduction: Assessing the treatment response of glioblastoma multiforme during immunotherapy (IT) is an open issue. Treatment response assessment maps (TRAMs) might help distinguish true tumor progression (TTP) and pseudoprogression (PsP) in this setting. Methods: We recruited 16 naïve glioblastoma patients enrolled in a phase II trial consisting of the Stupp protocol (a standardized treatment for glioblastoma involving combined radiotherapy and chemotherapy with temozolomide, followed by adjuvant temozolomide) plus IT with dendritic cells. Patients were followed up till progression or death; seven underwent a second surgery for suspected progression. Clinical, immunological, and MRI data were collected from all patients and histology in case of second surgery. Patients were classified as responders (progression-free survival, PFS > 12 months), and non-responders (PFS ≤ 12), HIGH-NK (natural killer cells, i.e., immunological responders), and LOW-NK (immunological non-responders) based on immune cell counts in peripheral blood. TRAMs differentiate contrast-enhancing lesions with different washout dynamics into hypothesized tumoral (conventionally blue-colored) vs. treatment-related (red-colored). Results: Using receiver operating characteristic (ROC) curves, a threshold of -0.066 in VBlue/VCE (volume of the blue portion of tumoral area/volume of contrast enhancement) variation between values obtained in the MRI performed before PsP/TTP and at TTP/PSP allowed to discriminate TTP from PsP with a sensitivity of 71.4% and a specificity of 100%. Among HIGH-NK patients, at month 6 there was a significant reduction compared to baseline and month 2 in median "blue" volumes. Discussion: In conclusion, in our pilot study TRAMs support the discrimination between tumoral and treatment-related enhancing features in immunological responders vs. non-responders, the distinction between PsP and TTP, and might provide surrogate markers of immunological response.

2.
Cancers (Basel) ; 16(4)2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38398183

RESUMEN

Fluorescein-mediated sonodynamic therapy (FL-SDT) is an extremely promising approach for glioma treatment, resulting from the combination of low-intensity focused ultrasound (FUS) with a sonosensitizer. In the present study, we evaluated the efficacy and immunomodulation of SDT with fluorescein as the sonosensitizer in immunocompetent GL261 glioma mice for the first time. In vitro studies demonstrated that the exposure of GL261 cells to FL-SDT induced immunogenic cell death and relevant upregulation of MHC class I, CD80 and CD86 expression. In vivo studies were then performed to treat GL261 glioma-bearing mice with FL-SDT, fluorescein alone, or FUS alone. Perturbation of the glioma-associated macrophage subset within the immune microenvironment was induced by all the treatments. Notably, a relevant depletion of myeloid-derived suppressor cells (MDSCs) and concomitant robust infiltration of CD8+ T cells were observed in the SDT-FL-treated mice, resulting in a significant radiological delay in glioma progression and a consequent improvement in survival. Tumor control and improved survival were also observed in mice treated with FL alone (median survival 41.5 days, p > 0.0001 compared to untreated mice), reflecting considerable modulation of the immune microenvironment. Interestingly, a high circulating lymphocyte-to-monocyte ratio and a very low proportion of MDSCs were predictive of better survival in FL- and FL-SDT-treated mice than in untreated and FUS-treated mice, in which elevated monocyte and MDSC frequencies correlated with worse survival. The immunostimulatory potential of FL-SDT treatment and the profound modulation of most immunosuppressive components within the microenvironment encouraged the exploration of the combination of FL-SDT with immunotherapeutic strategies.

3.
Eur Radiol ; 2024 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-38308012

RESUMEN

OBJECTIVES: To evaluate the methodological quality and diagnostic accuracy of MRI-based radiomic studies predicting O6-methylguanine-DNA methyltransferase (MGMT) promoter methylation status in gliomas. METHODS: PubMed Medline, EMBASE, and Web of Science were searched to identify MRI-based radiomic studies on MGMT methylation in gliomas published until December 31, 2022. Three raters evaluated the study methodological quality with Radiomics Quality Score (RQS, 16 components) and Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis Or Diagnosis (TRIPOD, 22 items) scales. Risk of bias and applicability concerns were assessed with QUADAS-2 tool. A meta-analysis was performed to estimate the pooled area under the curve (AUC) and to assess inter-study heterogeneity. RESULTS: We included 26 studies, published from 2016. The median RQS total score was 8 out of 36 (22%, range 8-44%). Thirteen studies performed external validation. All studies reported AUC or accuracy, but only 4 (15%) performed calibration and decision curve analysis. No studies performed phantom analysis, cost-effectiveness analysis, and prospective validation. The overall TRIPOD adherence score was between 50% and 70% in 16 studies and below 50% in 10 studies. The pooled AUC was 0.78 (95% CI, 0.73-0.83, I2 = 94.1%) with a high inter-study heterogeneity. Studies with external validation and including only WHO-grade IV gliomas had significantly lower AUC values (0.65; 95% CI, 0.57-0.73, p < 0.01). CONCLUSIONS: Study RQS and adherence to TRIPOD guidelines was generally low. Radiomic prediction of MGMT methylation status showed great heterogeneity of results and lower performances in grade IV gliomas, which hinders its current implementation in clinical practice. CLINICAL RELEVANCE STATEMENT: MGMT promoter methylation status appears to be variably correlated with MRI radiomic features; radiomic models are not sufficiently robust to be integrated into clinical practice to accurately predict MGMT promoter methylation status in patients with glioma before surgery. KEY POINTS: • Adherence to the indications of TRIPOD guidelines was generally low, as was RQS total score. • MGMT promoter methylation status prediction with MRI radiomic features provided heterogeneous diagnostic accuracy results across studies. • Studies that included grade IV glioma only and performed external validation had significantly lower diagnostic accuracy than others.

4.
Eur Radiol Exp ; 7(1): 57, 2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37782421

RESUMEN

In adrenoleukodystrophy (ALD), contrast enhancement (CE) is a disease activity marker, but there is uncertainty about the optimal delay, if any, between contrast injection and magnetic resonance imaging (MRI) acquisition to avoid false-negative results. We acquired axial two-dimensional (2D) and three-dimensional (3D) T1-weighted gradient-echo every 6 min from 0 to 36 min after contrast administration (gadobutrol 0.1 mmol/kg) in an ALD patient with enlarging white matter lesions and progressive neuropsychological symptoms, using a 3-T magnet. The image signal over time was qualitatively assessed and measured in two regions of interest. On 3D sequences, no definite CE was appreciated, whereas on 2D sequences, CE was noticed after 6 min and definitely evident after 12 min, when 73% of the maximum signal intensity was measured. In ALD subjects, contrast-enhanced 2D T1-weighted gradient-echo sequences acquired at least 10 min after contrast injection may be considered to reduce false negative results.Relevance statementOur report is the first attempt to find an optimal delay between contrast administration and T1-weighted acquisition in cALD patients in order to correctly detect disease activity and avoid false negative results.Key points• The optimal time between contrast injection and image acquisition for MRI of adrenoleukodystrophy is unknown.• Contrast enhancement predicts adrenoleukodystrophy progression and could help patient's selection for the therapy.• We acquired two post-contrast T1-GRE-2D/3D sequences several times to find the best injection-time.• T1-weighted 2D GRE resulted more sensitive than T1-weighted 3D GRE even after long intervals from injection.• A delay of about 10 min may minimize false negatives.


Asunto(s)
Adrenoleucodistrofia , Medios de Contraste , Humanos , Adrenoleucodistrofia/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
5.
Phys Med ; 112: 102610, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37331082

RESUMEN

PURPOSE: The use of topological metrics to derive quantitative descriptors from structural connectomes is receiving increasing attention but deserves specific studies to investigate their reproducibility and variability in the clinical context. This work exploits the harmonization of diffusion-weighted acquisition for neuroimaging data performed by the Italian Neuroscience and Neurorehabilitation Network initiative to obtain normative values of topological metrics and to investigate their reproducibility and variability across centers. METHODS: Different topological metrics, at global and local level, were calculated on multishell diffusion-weighted data acquired at high-field (e.g. 3 T) Magnetic Resonance Imaging scanners in 13 different centers, following the harmonization of the acquisition protocol, on young and healthy adults. A "traveling brains" dataset acquired on a subgroup of subjects at 3 different centers was also analyzed as reference data. All data were processed following a common processing pipeline that includes data pre-processing, tractography, generation of structural connectomes and calculation of graph-based metrics. The results were evaluated both with statistical analysis of variability and consistency among sites with the traveling brains range. In addition, inter-site reproducibility was assessed in terms of intra-class correlation variability. RESULTS: The results show an inter-center and inter-subject variability of <10%, except for "clustering coefficient" (variability of 30%). Statistical analysis identifies significant differences among sites, as expected given the wide range of scanners' hardware. CONCLUSIONS: The results show low variability of connectivity topological metrics across sites running a harmonised protocol.


Asunto(s)
Conectoma , Adulto , Humanos , Conectoma/métodos , Reproducibilidad de los Resultados , Benchmarking , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen
6.
Sci Rep ; 13(1): 9324, 2023 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-37291256

RESUMEN

Although only recently directional leads have proven their potential to compensate for sub-optimally placed electrodes, optimal lead positioning remains the most critical factor in determining Deep Brain Stimulation (DBS) outcome. Pneumocephalus is a recognized source of error, but the factors that contribute to its formation are still a matter of debate. Among these, operative time is one of the most controversial. Because cases of DBS performed with Microelectrode Recordings (MER) are affected by an increase in surgical length, it is useful to analyze whether MER places patients at risk for increased intracranial air entry. Data of 94 patients from two different institutes who underwent DBS for different neurologic and psychiatric conditions were analyzed for the presence of postoperative pneumocephalus. Operative time and use of MER, as well as other potential risk factors for pneumocephalus (age, awake vs. asleep surgery, number of MER passages, burr hole size, target and unilateral vs. bilateral implants) were examined. Mann-Whitney U and Kruskal-Wallis tests were utilized to compare intracranial air distributions across groups of categorical variables. Partial correlations were used to assess the association between time and volume. A generalized linear model was created to predict the effects of time and MER on the volume of intracranial air, controlling for other potential risk factors identified: age, number of MER passages, awake vs. asleep surgery, burr hole size, target, unilateral vs. bilateral surgery. Significantly different distributions of air volume were noted between different targets, unilateral vs. bilateral implants, and number of MER trajectories. Patients undergoing DBS with MER did not present a significant increase in pneumocephalus compared to patients operated without (p = 0.067). No significant correlation was found between pneumocephalus and time. Using multivariate analysis, unilateral implants exhibited lower volumes of pneumocephalus (p = 0.002). Two specific targets exhibited significantly different volumes of pneumocephalus: the bed nucleus of the stria terminalis with lower volumes (p < 0.001) and the posterior hypothalamus with higher volumes (p = 0.011). MER, time, and other parameters analyzed failed to reach statistical significance. Operative time and use of intraoperative MER are not significant predictors of pneumocephalus during DBS. Air entry is greater for bilateral surgeries and may be also influenced by the specific stimulated target.


Asunto(s)
Estimulación Encefálica Profunda , Neumocéfalo , Humanos , Estimulación Encefálica Profunda/efectos adversos , Microelectrodos , Neumocéfalo/etiología , Tempo Operativo , Trepanación/efectos adversos
7.
Cereb Cortex ; 33(16): 9532-9541, 2023 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-37344172

RESUMEN

Mutations of the voltage-gated sodium channel SCN1A gene (MIM#182389) are among the most clinically relevant epilepsy-related genetic mutations and present variable phenotypes, from the milder genetic epilepsy with febrile seizures plus to Dravet syndrome, a severe developmental and epileptic encephalopathy. Qualitative neuroimaging studies have identified malformations of cortical development in some patients and mild atrophic changes, partially confirmed by quantitative studies. Precise correlations between MRI findings and clinical variables have not been addressed. We used morphometric methods and network-based models to detect abnormal brain structural patterns in 34 patients with SCN1A-related epilepsy, including 22 with Dravet syndrome. By measuring the morphometric characteristics of the cortical mantle and volume of subcortical structures, we found bilateral atrophic changes in the hippocampus, amygdala, and the temporo-limbic cortex (P-value < 0.05). By correlating atrophic patterns with brain connectivity profiles, we found the region of the hippocampal formation as the epicenter of the structural changes. We also observed that Dravet syndrome was associated with more severe atrophy patterns with respect to the genetic epilepsy with febrile seizures plus phenotype (r = -0.0613, P-value = 0.03), thus suggesting that both the underlying mutation and seizure severity contribute to determine atrophic changes.


Asunto(s)
Epilepsias Mioclónicas , Epilepsia , Convulsiones Febriles , Humanos , Canal de Sodio Activado por Voltaje NAV1.1/genética , Convulsiones Febriles/diagnóstico por imagen , Convulsiones Febriles/genética , Epilepsias Mioclónicas/diagnóstico por imagen , Epilepsias Mioclónicas/genética , Epilepsia/genética , Mutación , Fenotipo
8.
Front Neurol ; 14: 1115325, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37153668

RESUMEN

Multiple hemorrhagic brain lesions are mainly diagnosed based on clinico-radiological features integrated with histological data. Intravascular papillary endothelial hyperplasia (IPEH), or Masson's tumor, is a very rare entity, particularly when localized in the brain. In this study, we describe a case of multiple recurrent brain IPEHs and provide details on the diagnostic phase, therapeutic approaches, and related challenges. A 55-year-old woman presented with a relapsing neurological deficit. Brain magnetic resonance imaging (MRI) revealed a hemorrhagic right frontal-parietal lesion. When new neurological symptoms occurred, subsequent MRI scans detected more bleeding cerebral lesions. She underwent a series of single hemorrhagic lesion debulking. For any samples that underwent histopathological examination, the first results were not informative; the second and the third results revealed hemangioendothelioma (HE); and the fourth results led to the IPEH diagnosis. Interferon alpha (IFN-α) and subsequently sirolimus were prescribed. Both were well tolerated. Clinical and radiological features remained stable 43 months after starting sirolimus therapy and 132 months after the first diagnosis. To date, 45 cases of intracranial IPEH have been reported, mostly as single lesions without parenchymal location. They are usually treated by surgery and sometimes by radiotherapy upon recurrence. Our case is notable for two main reasons: because of the consecutive recurrent multifocal exclusively cerebral lesions and the therapeutic approach we used. Based on multifocal brain recurrence and good performance, we propose pharmacological therapy, including IFN-α and sirolimus, to stabilize IPEH.

9.
Phys Med ; 110: 102577, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37126963

RESUMEN

Initiatives for the collection of harmonized MRI datasets are growing continuously, opening questions on the reliability of results obtained in multi-site contexts. Here we present the assessment of the brain anatomical variability of MRI-derived measurements obtained from T1-weighted images, acquired according to the Standard Operating Procedures, promoted by the RIN-Neuroimaging Network. A multicentric dataset composed of 77 brain T1w acquisitions of young healthy volunteers (mean age = 29.7 ± 5.0 years), collected in 15 sites with MRI scanners of three different vendors, was considered. Parallelly, a dataset of 7 "traveling" subjects, each undergoing three acquisitions with scanners from different vendors, was also used. Intra-site, intra-vendor, and inter-site variabilities were evaluated in terms of the percentage standard deviation of volumetric and cortical thickness measures. Image quality metrics such as contrast-to-noise and signal-to-noise ratio in gray and white matter were also assessed for all sites and vendors. The results showed a measured global variability that ranges from 11% to 19% for subcortical volumes and from 3% to 10% for cortical thicknesses. Univariate distributions of the normalized volumes of subcortical regions, as well as the distributions of the thickness of cortical parcels appeared to be significantly different among sites in 8 subcortical (out of 17) and 21 cortical (out of 68) regions of i nterest in the multicentric study. The Bland-Altman analysis on "traveling" brain measurements did not detect systematic scanner biases even though a multivariate classification approach was able to classify the scanner vendor from brain measures with an accuracy of 0.60 ± 0.14 (chance level 0.33).


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Adulto Joven , Adulto , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neuroimagen , Relación Señal-Ruido
10.
J Pers Med ; 13(5)2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37240978

RESUMEN

PURPOSE: to predict vestibular schwannoma (VS) response to radiosurgery by applying machine learning (ML) algorithms on radiomic features extracted from pre-treatment magnetic resonance (MR) images. METHODS: patients with VS treated with radiosurgery in two Centers from 2004 to 2016 were retrospectively evaluated. Brain T1-weighted contrast-enhanced MR images were acquired before and at 24 and 36 months after treatment. Clinical and treatment data were collected contextually. Treatment responses were assessed considering the VS volume variation based on pre- and post-radiosurgery MR images at both time points. Tumors were semi-automatically segmented and radiomic features were extracted. Four ML algorithms (Random Forest, Support Vector Machine, Neural Network, and extreme Gradient Boosting) were trained and tested for treatment response (i.e., increased or non-increased tumor volume) using nested cross-validation. For training, feature selection was performed using the Least Absolute Shrinkage and Selection Operator, and the selected features were used as input to separately build the four ML classification algorithms. To overcome class imbalance during training, Synthetic Minority Oversampling Technique was used. Finally, trained models were tested on the corresponding held out set of patients to evaluate balanced accuracy, sensitivity, and specificity. RESULTS: 108 patients treated with Cyberknife® were retrieved; an increased tumor volume was observed at 24 months in 12 patients, and at 36 months in another group of 12 patients. The Neural Network was the best predictive algorithm for response at 24 (balanced accuracy 73% ± 18%, specificity 85% ± 12%, sensitivity 60% ± 42%) and 36 months (balanced accuracy 65% ± 12%, specificity 83% ± 9%, sensitivity 47% ± 27%). CONCLUSIONS: radiomics may predict VS response to radiosurgery avoiding long-term follow-up as well as unnecessary treatment.

11.
Int J Mol Sci ; 25(1)2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38203308

RESUMEN

The methylation of the O6-methylguanine-DNA methyltransferase (MGMT) promoter is a molecular marker associated with a better response to chemotherapy in patients with glioblastoma (GB). Standard pre-operative magnetic resonance imaging (MRI) analysis is not adequate to detect MGMT promoter methylation. This study aims to evaluate whether the radiomic features extracted from multiple tumor subregions using multiparametric MRI can predict MGMT promoter methylation status in GB patients. This retrospective single-institution study included a cohort of 277 GB patients whose 3D post-contrast T1-weighted images and 3D fluid-attenuated inversion recovery (FLAIR) images were acquired using two MRI scanners. Three separate regions of interest (ROIs) showing tumor enhancement, necrosis, and FLAIR hyperintensities were manually segmented for each patient. Two machine learning algorithms (support vector machine (SVM) and random forest) were built for MGMT promoter methylation prediction from a training cohort (196 patients) and tested on a separate validation cohort (81 patients), based on a set of automatically selected radiomic features, with and without demographic variables (i.e., patients' age and sex). In the training set, SVM based on the selected radiomic features of the three separate ROIs achieved the best performances, with an average of 83.0% (standard deviation: 5.7%) for accuracy and 0.894 (0.056) for the area under the curve (AUC) computed through cross-validation. In the test set, all classification performances dropped: the best was obtained by SVM based on the selected features extracted from the whole tumor lesion constructed by merging the three ROIs, with 64.2% (95% confidence interval: 52.8-74.6%) accuracy and 0.572 (0.439-0.705) for AUC. The performances did not change when the patients' age and sex were included with the radiomic features into the models. Our study confirms the presence of a subtle association between imaging characteristics and MGMT promoter methylation status. However, further verification of the strength of this association is needed, as the low diagnostic performance obtained in this validation cohort is not sufficiently robust to allow clinically meaningful predictions.


Asunto(s)
Glioblastoma , Humanos , Glioblastoma/diagnóstico por imagen , Glioblastoma/genética , Radiómica , Estudios Retrospectivos , Imagen por Resonancia Magnética , Algoritmos , O(6)-Metilguanina-ADN Metiltransferasa , Metilasas de Modificación del ADN/genética , Proteínas Supresoras de Tumor/genética , Enzimas Reparadoras del ADN/genética
12.
Phys Med ; 104: 93-100, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36379160

RESUMEN

PURPOSE: Generating big-data is becoming imperative with the advent of machine learning. RIN-Neuroimaging Network addresses this need by developing harmonized protocols for multisite studies to identify quantitative MRI (qMRI) biomarkers for neurological diseases. In this context, image quality control (QC) is essential. Here, we present methods and results of how the RIN performs intra- and inter-site reproducibility of geometrical and image contrast parameters, demonstrating the relevance of such QC practice. METHODS: American College of Radiology (ACR) large and small phantoms were selected. Eighteen sites were equipped with a 3T scanner that differed by vendor, hardware/software versions, and receiver coils. The standard ACR protocol was optimized (in-plane voxel, post-processing filters, receiver bandwidth) and repeated monthly. Uniformity, ghosting, geometric accuracy, ellipse's ratio, slice thickness, and high-contrast detectability tests were performed using an automatic QC script. RESULTS: Measures were mostly within the ACR tolerance ranges for both T1- and T2-weighted acquisitions, for all scanners, regardless of vendor, coil, and signal transmission chain type. All measurements showed good reproducibility over time. Uniformity and slice thickness failed at some sites. Scanners that upgraded the signal transmission chain showed a decrease in geometric distortion along the slice encoding direction. Inter-vendor differences were observed in uniformity and geometric measurements along the slice encoding direction (i.e. ellipse's ratio). CONCLUSIONS: Use of the ACR phantoms highlighted issues that triggered interventions to correct performance at some sites and to improve the longitudinal stability of the scanners. This is relevant for establishing precision levels for future multisite studies of qMRI biomarkers.


Asunto(s)
Exactitud de los Datos , Humanos , Reproducibilidad de los Resultados
13.
World Neurosurg ; 168: 165-172, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36202344

RESUMEN

BACKGROUND: Laser interstitial thermal therapy (LITT) is a minimally invasive ablative technique with specific indications for neuro-oncology, especially in the case of lesions in eloquent areas. Even being performed through a small catheter under stereotactic conditions, the risk of damaging vital structures such as white matter tracts or cortical eloquent areas is not negligible. The mechanism of damage can be related to catheter insertion or to excessive laser ablation. An accurate preoperative workup, aimed at locating the eloquent structures, can be combined with a real-time intraoperative neurophysiologic monitoring to reduce surgical morbidity while maximizing the efficacy of LITT. METHODS: We developed a synergistic approach for neurophysiology-guided LITT based on state-of-the-art technologies, namely, magnetoencephalography, diffusion tensor imaging, and intraoperative neurophysiologic monitoring. RESULTS: As a result, we improved the planning phase thanks to a more precise representation of functional structures that allows the simulation of different trajectories and the identification of the most suitable trajectory to treat the lesion while respecting the functional boundaries. Catheter insertion is conducted under continuous neurophysiologic feedback and the ablation phase is modeled on the functional boundaries identified by stimulation, allowing it to be extremely accurate. CONCLUSIONS: An integrated approached guided by neurophysiology is able to reduce the surgical morbidity even in a relatively accurate technique such as LITT. To the best of our knowledge, this represents the first report on this synergistic approach which could really impact the treatment of tumors in eloquent areas. Future studies are needed in the effort to implement this approach in functional or epilepsy neurosurgery as well.


Asunto(s)
Neoplasias Encefálicas , Terapia por Láser , Humanos , Imagen de Difusión Tensora , Neurofisiología , Terapia por Láser/métodos , Procedimientos Neuroquirúrgicos , Rayos Láser , Imagen por Resonancia Magnética/métodos , Neoplasias Encefálicas/cirugía
14.
Phys Med ; 103: 37-45, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36219961

RESUMEN

Quantitative Susceptibility Mapping (QSM) is an MRI-based technique allowing the non-invasive quantification of iron content and myelination in the brain. The RIN - Neuroimaging Network established an optimized and harmonized protocol for QSM across ten sites with 3T MRI systems from three different vendors to enable multicentric studies. The assessment of the reproducibility of this protocol is crucial to establish susceptibility as a quantitative biomarker. In this work, we evaluated cross-vendor reproducibility in a group of six traveling brains. Then, we recruited fifty-one volunteers and measured the variability of QSM values in a cohort of healthy subjects scanned at different sites, simulating a multicentric study. Both voxelwise and Region of Interest (ROI)-based analysis on cortical and subcortical gray matter were performed. The traveling brain study yielded high structural similarity (∼0.8) and excellent reproducibility comparing maps acquired on scanners from two different vendors. Depending on the ROI, we reported a quantification error ranging from 0.001 to 0.017 ppm for the traveling brains. In the cohort of fifty-one healthy subjects scanned at nine different sites, the ROI-dependent variability of susceptibility values, of the order of 0.005-0.025 ppm, was comparable to the result of the traveling brain experiment. The harmonized QSM protocol of the RIN - Neuroimaging Network provides a reliable quantification of susceptibility in both cortical and subcortical gray matter regions and it is ready for multicentric and longitudinal clinical studies in neurological and pychiatric diseases.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sustancia Gris/diagnóstico por imagen , Mapeo Encefálico/métodos
15.
Neurotherapeutics ; 19(6): 1942-1950, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36129603

RESUMEN

Hypothermia is a promising therapeutic strategy for severe vasospasm and other types of non-thrombotic cerebral ischemia, but its clinical application is limited by significant systemic side effects. We aimed to develop an intraventricular device for the controlled cooling of the cerebrospinal fluid, to produce a targeted hypothermia in the affected cerebral hemisphere with a minimal effect on systemic temperature. An intraventricular cooling device (acronym: V-COOL) was developed by in silico modelling, in vitro testing, and in vivo proof-of-concept application in healthy Wistar rats (n = 42). Cerebral cortical temperature, rectal temperature, and intracranial pressure were monitored at increasing flow rate (0.2 to 0.8 mL/min) and duration of application (10 to 60 min). Survival, neurological outcome, and MRI volumetric analysis of the ventricular system were assessed during the first 24 h. The V-COOL prototyping was designed to minimize extra-cranial heat transfer and intra-cranial pressure load. In vivo application of the V-COOL device produced a flow rate-dependent decrease in cerebral cortical temperature, without affecting systemic temperature. The target degree of cerebral cooling (- 3.0 °C) was obtained in 4.48 min at the flow rate of 0.4 mL/min, without significant changes in intracranial pressure. Survival and neurological outcome at 24 h showed no significant difference compared to sham-treated rats. MRI study showed a transient dilation of the ventricular system (+ 38%) in a subset of animals. The V-COOL technology provides an effective, rapid, selective, and safe cerebral cooling to a clinically relevant degree of - 3.0 °C.


Asunto(s)
Hipotermia Inducida , Hipotermia , Animales , Ratas , Temperatura Corporal , Ratas Wistar , Bioingeniería , Encéfalo
16.
Acta Myol ; 41(2): 76-83, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35832502

RESUMEN

The recent approval of disease-modifying therapies for spinal muscular atrophy (SMA) raised the need of alternative outcome measures to evaluate treatment efficacy. In this study, we investigated the potential of muscle quantitative MRI (qMRI) as a biomarker of disease progression in adult SMA3 patients during nusinersen treatment. Six adult SMA3 patients (age ranging from 19 to 65 years) underwent 2-point Dixon muscle qMRI at beginning of nusinersen treatment (T0) and after 14 months (T14) to evaluate the muscle fat fraction (FF) at thigh and leg levels; patients were clinically assessed at T0 and T14 with the Hammersmith Functional Rating Scale Expanded (HFMSE), the Revised Upper Limb Module (RULM) and the 6-minute walk test (6MWT). At T0, vastus lateralis muscle displayed the highest mean FF (67.5%), while tibialis anterior was the most preserved one (mean FF = 35.2%). At T0, a slightly significant correlation of FF with HFMSE (p = 0.042) and disease duration (p = 0.042) at thigh level and only with HFMSE (p = 0.042) at leg level was found. At T14, no significant change of mean FF values at thigh and leg muscles was found compared to T0. Conversely, a statistically significant (p = 0.042) improvement of HFMSE was reported at T14. We observed no significant change of FF in thigh and leg muscles after 14 months of nusinersen therapy despite a significant clinical improvement of HFMSE. Further studies with longer follow-up and larger cohorts are needed to better investigate the role of qMRI as marker of disease progression in SMA patients.


Asunto(s)
Atrofia Muscular Espinal , Atrofias Musculares Espinales de la Infancia , Adulto , Anciano , Progresión de la Enfermedad , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Persona de Mediana Edad , Músculo Esquelético/diagnóstico por imagen , Oligonucleótidos , Atrofias Musculares Espinales de la Infancia/tratamiento farmacológico , Adulto Joven
17.
Front Neurol ; 13: 855125, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35493836

RESUMEN

Neuroimaging studies often lack reproducibility, one of the cardinal features of the scientific method. Multisite collaboration initiatives increase sample size and limit methodological flexibility, therefore providing the foundation for increased statistical power and generalizable results. However, multisite collaborative initiatives are inherently limited by hardware, software, and pulse and sequence design heterogeneities of both clinical and preclinical MRI scanners and the lack of benchmark for acquisition protocols, data analysis, and data sharing. We present the overarching vision that yielded to the constitution of RIN-Neuroimaging Network, a national consortium dedicated to identifying disease and subject-specific in-vivo neuroimaging biomarkers of diverse neurological and neuropsychiatric conditions. This ambitious goal needs efforts toward increasing the diagnostic and prognostic power of advanced MRI data. To this aim, 23 Italian Scientific Institutes of Hospitalization and Care (IRCCS), with technological and clinical specialization in the neurological and neuroimaging field, have gathered together. Each IRCCS is equipped with high- or ultra-high field MRI scanners (i.e., ≥3T) for clinical or preclinical research or has established expertise in MRI data analysis and infrastructure. The actions of this Network were defined across several work packages (WP). A clinical work package (WP1) defined the guidelines for a minimum standard clinical qualitative MRI assessment for the main neurological diseases. Two neuroimaging technical work packages (WP2 and WP3, for clinical and preclinical scanners) established Standard Operative Procedures for quality controls on phantoms as well as advanced harmonized quantitative MRI protocols for studying the brain of healthy human participants and wild type mice. Under FAIR principles, a web-based e-infrastructure to store and share data across sites was also implemented (WP4). Finally, the RIN translated all these efforts into a large-scale multimodal data collection in patients and animal models with dementia (i.e., case study). The RIN-Neuroimaging Network can maximize the impact of public investments in research and clinical practice acquiring data across institutes and pathologies with high-quality and highly-consistent acquisition protocols, optimizing the analysis pipeline and data sharing procedures.

18.
Neurology ; 98(17): e1771-e1782, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-35256485

RESUMEN

BACKGROUND AND OBJECTIVES: The identification of possible hippocampal alterations is a crucial point for the diagnosis and therapy of patients with unilateral temporal lobe epilepsy (TLE). This study aims to investigate the role of neurite orientation dispersion and density imaging (NODDI) compared to diffusion tensor imaging (DTI) in the comprehension of hippocampal microstructure in TLE. METHODS: DTI and NODDI metrics were calculated in the hippocampi of adult patients with TLE, with and without histology-confirmed hippocampal sclerosis (HS), and in age/sex-matched healthy controls (HC). Diffusion metrics and hippocampal volumes of the pathologic side were compared within participants and between participants among the HS, non-HS, and HC groups. Diffusion metrics were also correlated with hippocampal volume and patients' clinical features. After surgery, hippocampal specimens were processed for neuropathology examinations. RESULTS: Fifteen patients with TLE (9 with and 6 without HS) and 11 HC were included. Hippocampal analyses resulted in a significant increase in fractional anisotropy (FA) and mean diffusivity (MD; mm2/s × 10-3) and decrease in orientation dispersion index (ODI) comparing the pathologic side of patients with HS and their relative nonpathologic side (0.203 vs 0.183, 0.825 vs 0.724, 0.366 vs 0.443, respectively), the pathologic side of patients without HS (0.203 vs 0.169, 0.825 vs 0.745, 0.366 vs 0.453, respectively), and HC (0.203 vs 0.172, 0.825 vs 0.729, 0.366 vs 0.447, respectively). Moreover, neurite density (ND) was significantly decreased comparing both hippocampi of patients with HS (0.416 vs 0.460). A significant increase in free-water isotropic volume fraction (fiso) was found in the comparison of pathologic hippocampi of patients with HS and nonpathologic hippocampi of patients with HS (0.323 vs 0.258) and HC (0.323 vs 0.226). Hippocampal volume of all patients with TLE negatively correlated with MD (r = -0.746, p = 0.0145) and positively correlated with ODI (r = 0.719, p = 0.0145). Fiso and ND of sclerotic hippocampi positively correlated with disease duration (r = 0.684, p = 0.0424 and r = 0.670, p = 0.0486, respectively). Immunohistochemistry in sclerotic hippocampal specimens revealed neuronal loss in the pyramidal layer and fiber reorganization at the level of stratum lacunosum-moleculare, confirming ODI and ND metrics. DISCUSSION: This study shows the capability of diffusion MRI metrics to detect hippocampal microstructural alterations. Among them, ODI seems to better highlight the fiber reorganization observed by neuropathology in sclerotic hippocampi.


Asunto(s)
Epilepsia del Lóbulo Temporal , Adulto , Atrofia/patología , Imagen de Difusión Tensora/métodos , Epilepsia del Lóbulo Temporal/diagnóstico por imagen , Epilepsia del Lóbulo Temporal/patología , Hipocampo/diagnóstico por imagen , Hipocampo/patología , Humanos , Imagen por Resonancia Magnética , Neuritas , Esclerosis/diagnóstico por imagen , Esclerosis/patología
19.
J Neurosci Methods ; 367: 109439, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34915045

RESUMEN

BACKGROUND: MRI is a fundamental tool to detect brain structural anomalies and improvement in this technique has the potential to visualize subtle abnormalities currently undetected. Correlation between pre-operative MRI and histopathology is required to validate the neurobiological basis of MRI abnormalities. However, precise MRI-histology matching is very challenging with the surgical samples. We previously developed a coregistration protocol to match the in-vivo MRI with ex-vivo MRI obtained from surgical specimens. Now, we complete the process to successfully align ex-vivo MRI data with the proper digitalized histological sections in an automatic way. NEW METHOD: The implemented pipeline is composed by the following steps: a) image pre-processing made of MRI and histology volumes conversion and masking; b) gross rigid body alignment between MRI volume and histology virtual slides; c) rigid alignment between each MRI section and histology slice and estimate of the correlation coefficient for each step to select the MRI slice that best matches histology; d) final linear registration of the selected slices. RESULTS: This method is fully automatic, except for the first masking step, fast and reliable in comparison to the manual one, as assessed using a Bland-Altman plot. COMPARISON WITH EXISTING METHODS: The visual assessment usually employed for choosing the best fitting ex-vivo MRI slice for each stained section takes hours and requires practice. Goubran et al. (2015) proposed an iterative registration protocol but its aim and methods were different from ours. No others similar methods are reported in the literature. CONCLUSIONS: This protocol completes our previous pipeline. The ultimate goal will be to apply the entire process to finely investigate the relationship between clinical MRI data and histopathological features in patients with drug-resistant epilepsy.


Asunto(s)
Epilepsia Refractaria , Imagen por Resonancia Magnética , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/cirugía , Técnicas Histológicas/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos
20.
Phys Med ; 89: 20-28, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34343763

RESUMEN

PURPOSE: In this work, the potential of an innovative "edgeless" silicon diode was evaluated as a response to the still unmet need of a reliable tool for plan dosimetry verification of very high dose, non-coplanar, patient-specific radiosurgery treatments. In order to prove the effectiveness of the proposed technology, we focused on radiosurgical treatments for functional disease like tremor or pain. METHODS: The edgeless diodes response has been validated with respect to clinical practice standard detectors by reproducing the reference dosimetry data adopted for the Treatment Planning System. In order to evaluate the potential for radiosurgery patient-specific treatment plan verification, the anthropomorphic phantom Alderson RANDO has been adopted along with three edgeless sensors, one placed in the centre of the Planning Target Volume, one superiorly and one inferiorly. RESULTS: The reference dosimetry data obtained from the edgeless detectors are within 2.6% for output factor, off-axis ratio and well within 2% for tissue phantom ratio when compared to PTW 60,018 diode. The edgeless detectors measure a dose discrepancy of approximately 3.6% from the mean value calculated by the TPS. Larger discrepancies are obtained in very steep gradient dose regions when the sensors are placed outside the PTV. CONCLUSIONS: The angular independent edgeless diode is proposed as an innovative dosimeter for patient quality assurance of brain functional disorders and other radiosurgery treatments. The comparison of the diode measurements with TPS calculations confirms that edgeless diodes are suitable candidates for patient-specific dosimetric verification in very high dose ranges delivered by non-isocentric stereotactic radiosurgery modalities.


Asunto(s)
Radiocirugia , Humanos , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Silicio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...