Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Int J Cardiol Heart Vasc ; 51: 101371, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38435380

RESUMEN

Background: This study aimed to investigate the characteristics and outcomes of patients diagnosed with Brugada syndrome (BrS) who underwent implantable loop recorder (ILR) insertion during routine clinical activity. Methods: We conducted a comprehensive screening of all consecutive patients diagnosed with BrS at our institution. We analyzed baseline clinical characteristics, arrhythmic findings, and outcomes. Results: Out of 147 BrS patients, 42 (29 %) received an ILR, 13 (9 %) underwent implantable cardioverter-defibrillator (ICD) placement, and 92 patients (63 %) continued regular cardiological follow-up. Patients who received an ILR had a higher prevalence of suspected arrhythmic syncope (43 % vs. 22 %, p = 0.012) and tended to be younger (median age 38 years, interquartile range 30-52, vs. 43 years, 35-55, p = 0.044) with a higher presence of SCN5A gene mutations (17 % vs. 6 %, p = 0.066) compared to those who continued regular follow-up. Additionally, compared to patients with an ICD, those with an ILR had a significantly lower frequency of positive programmed ventricular stimulation (0 % vs. 91 %, p < 0.001). During a median follow-up period of 14.7 months (4.7-44.8), no deaths occurred among the patients with ILR. Eight individuals (19 %) were diagnosed with arrhythmic findings through continuous ILR monitoring, primarily atrial fibrillation, and asystolic pauses. The median time from insertion to the occurrence of these events was 8.7 months (3.6-46.4). No adverse events related to ILR were reported. Conclusion: Continuous monitoring with ILR may facilitate the timely detection of non-malignant rhythm disorders in BrS patients with risk factors but without an indication for primary prevention ICD implantation.

2.
Ann Cardiothorac Surg ; 13(1): 44-53, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38380141

RESUMEN

Atrial fibrillation (AF) has been reported as a major cause of cardiac morbidity and mortality, and significantly reduces the quality of life in symptomatic patients. Current guidelines recommend antiarrhythmic drugs and catheter ablation (CA) as first-line therapy. Despite CA showed to be associated with lower incidence of peri-procedural complications, rhythm outcomes are far from optimal. Indeed, patients undergoing CA frequently require multiple AF ablation procedures, especially in those with persistent and long-standing persistent AF. While surgical ablation can provide transmural lesions, surgical invasiveness has limited the widespread use of this approach due to the increased perioperative complications. The development of minimally invasive thoracoscopic approaches has renewed the interest towards surgical ablation, thus favoring more simplified ablation sets. Therefore, the concept of "hybrid" ablation has emerged in order to theoretically enhance advantages of both minimally invasive and CA procedures while seeking to improve rhythm outcomes and reduce invasiveness and incidence of perioperative complications. On one hand, it provides the effectiveness of a surgical ablation, on the other, electrical mapping during CA can identify and treat any ablation gap or provide additional ablation lines, thus improving the chance of a stable sinus rhythm restoration at long-term follow-up. Three main thoracoscopic strategies are currently available. All of them can be performed in conjunction with the "catheter ablation procedure": the "Fusion" technique, the bipolar clamp technique, and the most recent "convergent" technique. CA can be performed either simultaneously or with a staged approach after a blanking period in order to allow the ablation lesion to stabilize. Excellent results of the hybrid procedures have been reported in terms of rhythm outcomes and incidence of perioperative complications. This narrative review aims to discuss the rationale behind the concept of hybrid ablation for the treatment of AF regarding different available strategies, results and expert opinions.

3.
Pacing Clin Electrophysiol ; 47(3): 417-428, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38375940

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is a common heart rhythm disorder that is associated with an increased risk of stroke and heart failure (HF). Initially, an association between AF and ion channel dysfunction was identified, classifying the pathology as a predominantly electrical disease. More recently it has been recognized that fibrosis and structural atrial remodeling play a driving role in the development of this arrhythmia also in these cases. PURPOSE: Understanding the role of fibrosis in genetic determined AF could be important to better comprise the pathophysiology of this arrhythmia and to refine its management also in nongenetic forms. In this review we analyze genetic and epigenetic mechanisms responsible for AF and their link with atrial fibrosis, then we will consider analogies with the pathophysiological mechanism in nongenetic AF, and discuss consequent therapeutic options.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/complicaciones , Atrios Cardíacos , Fibrosis , Canales Iónicos/genética , Canales Iónicos/uso terapéutico
5.
J Interv Card Electrophysiol ; 67(3): 439-441, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38099975

RESUMEN

ESC Guidelines don't recommend ICD implantation within 40 days after MI, on the basis of old evidence with several limitations. However, a significant number of patients remain at high risk of arrhythmic death also in the early period after ACS, in these patients early ICD implantation or LifeVest may be use with benefit on survival.


Asunto(s)
Desfibriladores Implantables , Infarto del Miocardio , Humanos , Infarto del Miocardio/terapia , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control
6.
J Cardiovasc Med (Hagerstown) ; 25(2): 95-103, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38149699

RESUMEN

In the latest ESC/EACTS Guidelines for the Management of Valvular Heart Disease, right ventricular dilatation and dysfunction, severe pulmonary hypertension and tricuspid annulus dilatation were reported to be the most important parameters to consider in patient selection for tricuspid valve interventions. Indeed, comprehensive right ventricular assessment is crucial in patients with severe tricuspid regurgitation who may benefit from transcatheter or surgical procedures. However, the only guideline parameter considered for intervention has been tricuspid annular dilatation in the presence of at least mild to moderate tricuspid regurgitation, with no other right ventricular markers used in the decision-making process for invasive treatment. Notably, challenges in the assessment of right ventricular function may limit establishing thresholds for defining right ventricular dysfunction. The aim of this review is to summarize current evidence on the prognostic significance of right ventricular function in patients with tricuspid regurgitation undergoing percutaneous or surgical interventions.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Ventrículos Cardíacos , Pronóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía
7.
Artículo en Inglés | MEDLINE | ID: mdl-37930655

RESUMEN

We report the case of a 62-year-old man who was admitted to the Cardiac Department for TakoTsubo and ACC by torsades de point, secondary to acute kidney disease. We decide to discharge with a portable defibrillator. One month after cardiac magnetic resonance showed a complete recovery of left ventricular function.

8.
Artículo en Inglés | MEDLINE | ID: mdl-37930657

RESUMEN

Myocarditis is a potentially fatal complication of coronavirus disease 2019 (COVID-19), which is caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. COVID-19 myocarditis appears to have distinct inflammatory characteristics that distinguish it from other viral etiologies. COVID-19 myocarditis can present with symptoms ranging from dyspnea and chest pain to acute heart failure and death. It is critical to detect any cases of myocarditis, especially fulminant myocarditis, which can be characterized by signs of heart failure and arrhythmias. Serial troponins, echocardiography, and electrocardiograms should be performed as part of the initial workup for suspected myocarditis. The second step in detecting myocarditis is cardiac magnetic resonance imaging and endomyocardial biopsy. Treatment for COVID-19 myocarditis is still debatable; however, combining intravenous immunoglobulins and corticosteroids may be effective, especially in cases of fulminant myocarditis. Overall, more research is needed to determine the incidence of COVID-19 myocarditis , and the use of intravenous immunoglobulins and corticosteroids in combination requires large randomized controlled trials to determine efficacy. The purpose of this review is to summarize current evidence on the subject. This review aims to summarise current evidence on this topic.

9.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37481220

RESUMEN

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

10.
Pacing Clin Electrophysiol ; 46(7): 674-683, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37279193

RESUMEN

INTRODUCTION: Permanent His bundle pacing (HBP) is the most physiological pacing modality, and new implantation systems are now available. The aim of the present study was to describe and compare four different techniques to perform HBP. METHODS AND RESULTS: We included all consecutive patients who underwent a HBP attempt in our initial experience between June 2020 and May 2022. The success and characteristics of the procedure were compared among four implantation techniques: the Biotronik Selectra 3D sheath with Solia S60 lead (Selectra 3D), the Boston Scientific Site Selective Pacing Catheter with Ingevity lead (SSPC), the Abbott steerable stylet locator with Tendril lead (Locator), and the use of a standard stylet manually pre-shaped with a conventional pacing lead (Curved stylet). Ninety-eight patients (median age 79 years [interquartile range, 73-83], 83% men) were identified. The Selectra 3D technique was used in 43 procedures, SSPC in 26, Locator in 18 and Curved stylet in 11. The groups had similar clinical characteristics. Overall, procedural success was achieved in 91 patients (93%) with similar proportions among groups (p = .986). Fluoroscopy and procedural times were 6.0 (4.4-8.5) and 60 (45-75) min, respectively, without significant differences (p = .333 and p = .790). The rate of selective capture, the pacing threshold, and the paced QRS duration were also comparable. There was one pre-discharge HBP lead dislodgment (1%) that required implant revision. CONCLUSION: In our experience, four techniques for HBP achieved comparable results in terms of safety and effectiveness. The availability of different systems may lead to widespread use of physiological pacing.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Masculino , Humanos , Anciano , Femenino , Estimulación Cardíaca Artificial/métodos , Resultado del Tratamiento , Cateterismo Cardíaco , Estudios Retrospectivos , Electrocardiografía/métodos
11.
Acta Cardiol ; 78(9): 992-999, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37318077

RESUMEN

BACKGROUND: A complex transvenous lead extraction (TLE) procedure could be associated with lower success and higher complication rates in inexperienced hands. In this study, we aim to assess the factors that determine procedural difficulty in TLE. METHODS: We retrospectively studied 200 consecutive patients undergoing TLE in a single referral centre from June 2020 to December 2021. Lead extraction difficulty was assessed by the success of simple manual traction with or without a locking stylet, the need for advanced extraction tools and the number of tools required to extract the lead. Logistic and linear regression analyses were used to determine the factors independently affecting these 3 parameters. RESULTS: 363 leads were extracted from 200 patients (79% males, mean age 66.85 years). The indication for TLE was device-related infection in 51.5%. Multivariate analysis revealed the lead indwelling time to be the only factor affecting the 3 parameters of difficulty. Passive fixation leads and dual coil leads increased procedural difficulty by affecting 2 parameters each. Factors that affected one parameter included infected leads, coronary sinus leads, older age of the patient and a history of valvular heart disease, all associated with a simpler procedure. Right ventricular leads were associated with a more complex one. CONCLUSION: The most important factor that increased TLE procedural difficulty was a longer lead indwelling time, followed by passive fixation and dual-coil leads. Other contributing factors were the presence of infection, coronary sinus leads, older patients, a history of valvular heart disease and right ventricular leads.

12.
Front Cardiovasc Med ; 10: 1108696, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36998972

RESUMEN

Severe aortic stenosis (AS) is the most common valvular heart disease with a prevalence rate of more than 4% in 75-year-old people or older. Similarly, cardiac amyloidosis (CA), especially "wild-type transthyretin" (wTTR), has shown a prevalence rate ranging from 22% to 25% in people older than 80 years. The detection of the concomitant presence of CA and AS is challenging primarily because of the similar type of changes in the left ventricle caused by AS and CA, which share some morphological characteristics. The aim of this review is to identify the imaging triggers in order to recognize occult wtATTR-CA in patients with AS, clarifying the crucial step of the diagnostic process. Multimodality imaging methods such as echocardiography, cardiac magnetic resonance, cardiac computed tomography, and DPD scintigraphy will be analyzed as part of the available diagnostic workup to identify wtATTR-CA early in patients with AS.

14.
Int J Cardiol ; 378: 32-38, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36841289

RESUMEN

BACKGROUND: Transvenous lead extraction (TLE) has shown a safe and efficacy profile in the intraoperative and short-term setting; however, data on long-term outcomes are limited. OBJECTIVE: The purpose of this study was to assess long-term outcomes and prognostic factors in patients who underwent TLE. METHODS: Consecutive patients with cardiac implantable electronic device (CIED) who underwent TLE between 2014 and 2016 were retrospectively studied. The primary outcome was the composite endpoint of death and repeated TLE stratified by infective/non-infective indication. Individual components of the primary outcome were also evaluated. RESULTS: One hundred ninety-one patients were included in the analysis, 50% extracted for CIED-related infection. Complete procedural success was achieved in 189 patients (99%) with no major acute complications. After a median of 6.5 years, infection indication was associated with significantly lower event-free survival (67% vs. 83% non-infection group, adjusted hazard ratio [aHR] 1.97, 95% confidence interval [CI] 1.02-3.81, p = 0.04). All-cause mortality rate was higher in the TLE infection group (30% vs. 10%, p < 0.01). The rate of repeated TLE did not differ between groups (4% vs. 7%, p = 0.62). Among patients who had TLE for infection, the presence of vegetation (aHR 2.56; 95%CI 1.17-5.63, p = 0.02) and positive blood cultures (aHR 2.64; 95%CI 1.04-6.70, p = 0.04) were independently associated with the primary outcome. CONCLUSION: Patients who underwent TLE for CIED-related infection exhibit a high mortality risk during long-term follow-up. Vegetation and positive blood cultures in patients with CIED-related infection are associated with a worse prognosis regardless of successful and uncomplicated TLE.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Centros de Atención Terciaria , Remoción de Dispositivos , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento
15.
Heart Rhythm ; 20(3): 395-404, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36496135

RESUMEN

BACKGROUND: Limited data on the real-world safety and efficacy of leadless pacemakers (LPMs) post-transvenous lead extraction (TLE) are available. OBJECTIVE: The purpose of this study was to assess the long-term safety and effectiveness of LPMs following TLE in comparison with LPMs de novo implantation. METHODS: Consecutive patients who underwent LPM implantation in 12 European centers joining the International LEAdless PacemakEr Registry were enrolled. The primary end point was the comparison of LPM-related complication rate at implantation and during follow-up (FU) between groups. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1179 patients enrolled, 15.6% underwent a previous TLE. During a median FU of 33 (interquartile range 24-47) months, LPM-related major complications and all-cause mortality did not differ between groups (TLE group: 1.6% and 5.4% vs de novo group: 2.2% and 7.8%; P = .785 and P = .288, respectively). Pacing threshold (PT) was higher in the TLE group at implantation and during FU, with very high PT (>2 V@0.24 ms) patients being more represented than in the de novo implantation group (5.4% vs 1.6 %; P = .004). When the LPM was deployed at a different right ventricular (RV) location than the one where the previous transvenous RV lead was extracted, a lower proportion of high PT (>1-2 V@0.24 ms) patients at implantation, 1-month FU, and 12-month FU (5.9% vs 18.2%, P = .012; 3.4% vs 12.9%, P = .026; and 4.3% vs 14.5%, P = .037, respectively) was found. CONCLUSION: LPMs showed a satisfactory safety and efficacy profile after TLE. Better electrical parameters were obtained when LPMs were implanted at a different RV location than the one where the previous transvenous RV lead was extracted.


Asunto(s)
Marcapaso Artificial , Humanos , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Sistema de Registros , Diseño de Equipo
16.
Pacing Clin Electrophysiol ; 46(1): 39-43, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35941725

RESUMEN

Leadless pacemaker implantation (LPI) has fewer device complications and reduced chance of infection compared to conventional pacemakers. Dextrocardia with situs viscerum inversus (DC+SVI) is a rare condition, which seldom leads to cardiac complications. However, its presence poses a challenge to operators in cardiac procedures. LPI reports in DC patients are scarce. We report a case of LPI in a DC+SVI patient, followed by a brief but comprehensive literature review.


Asunto(s)
Dextrocardia , Marcapaso Artificial , Situs Inversus , Humanos , Dextrocardia/complicaciones , Situs Inversus/complicaciones , Situs Inversus/terapia
17.
Int J Cardiol ; 371: 197-203, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36115442

RESUMEN

BACKGROUND: Age-related differences on leadless pacemaker (LP) are poorly described. Aim of this study was to compare clinical indications, periprocedural and mid-term device-associated outcomes in a large real-world cohort of LP patients, stratified by age at implantation. METHODS: Two cohorts of younger and older patients (≤50 and > 50 years old) were retrieved from the iLEAPER registry. The primary outcome was to compare the underlying indication why a LP was preferred over a transvenous PM across the two cohorts. Rates of peri-procedural and mid-term follow-up major complications as well as LP electrical performance were deemed secondary outcomes. RESULTS: 1154 patients were enrolled, with younger patients representing 6.2% of the entire cohort. Infective and vascular concerns were the most frequent characteristics that led to a LP implantation in the older cohort (45.8% vs 67.7%, p < 0.001; 4.2% vs 16.4%, p = 0.006), while patient preference was the leading cause to choose a LP in the younger (47.2% vs 5.6%, p < 0.001). Median overall procedural (52 [40-70] vs 50 [40-65] mins) and fluoroscopy time were similar in both groups. 4.3% of patients experienced periprocedural complications, without differences among groups. Threshold values were higher in the younger, both at discharge and at last follow-up (0.63 [0.5-0.9] vs 0.5 [0.38-0-7] V, p = 0.004). CONCLUSION: When considering LP indications, patient preference was more common in younger, while infective and vascular concerns were more frequent in the older cohort. Rates of device-related complications did not differ significantly. Younger patients tended to have a slightly higher pacing threshold at mid-term follow-up.


Asunto(s)
Marcapaso Artificial , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Factores de Tiempo , Estimulación Cardíaca Artificial/efectos adversos
18.
Monaldi Arch Chest Dis ; 93(2)2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36128930

RESUMEN

Varicella zoster virus (VZV) is a Herpesviridae family double-stranded DNA virus that only affects humans. The first clinical manifestation appears to be varicella, typical of childhood. VZV, on the other hand, becomes latent in ganglion neurons throughout the neuroaxis after primary infection. The VZV reactivates and travels along peripheral nerve fibers in the elderly and immunocompromised individuals, resulting in Zoster. It can, however, spread centrally and infect cerebral and extracranial arteries, resulting in vasculopathy, which can lead to transient ischemic attacks, strokes, aneurysms, cavernous sinus thrombosis, giant cell arteritis, and granulomatous aortitis. Although the mechanisms of virus-induced pathological vascular remodeling are not fully understood, recent research indicates that inflammation and dysregulation of ligand-1 programmed death play a significant role. Few studies, on the other hand, have looked into the role of VZV in cardiovascular disease. As a result, the purpose of this review is to examine the relationship between VZV and cardiovascular disease, the efficacy of the vaccine as a protective mechanism, and the target population of heart disease patients who could benefit from vaccination.


Asunto(s)
Enfermedades Cardiovasculares , Varicela , Herpes Zóster , Accidente Cerebrovascular , Humanos , Anciano , Herpesvirus Humano 3 , Enfermedades Cardiovasculares/epidemiología , Herpes Zóster/epidemiología , Herpes Zóster/prevención & control , Accidente Cerebrovascular/epidemiología
19.
Monaldi Arch Chest Dis ; 93(2)2022 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-35872629

RESUMEN

We report the case of a 47-year-old woman who was admitted to the cardiac department for worsening dyspnea. The last chest computed tomography (CT) showed a rapid increase in pulmonary artery dimension (65 mm in 2019, 76 mm in 2021). The symptoms reported by the patient were due to important extrinsic compression of the left main coronary artery (LMCA). In this case, it is very difficult to choose the best therapeutic strategy. In the end, we decided to treat the left main coronary for prevention. After 3 months no new clinical symptoms have developed.


Asunto(s)
Estenosis Coronaria , Cardiopatías Congénitas , Hipertensión Pulmonar , Femenino , Humanos , Persona de Mediana Edad , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/etiología , Arteria Pulmonar/diagnóstico por imagen , Dilatación , Angiografía Coronaria
20.
J Cardiovasc Electrophysiol ; 33(10): 2195-2201, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35842805

RESUMEN

INTRODUCTION: The prevalence and impact of pulmonary embolism (PE) in patients with lead-related infective endocarditis undergoing transvenous lead extraction (TLE) are unknown. METHODS: Twenty-five consecutive patients with vegetations ≥10 mm at transoesophageal echocardiography were prospectively studied. Contrast-enhanced chest computed tomography (CT) was performed before (pre-TLE) and after (post-TLE) the lead extraction procedure. RESULTS: Pre-TLE CT identified 18 patients (72%) with subclinical PE. The size of vegetations in patients with PE did not differ significantly from those without (median 20.0 mm [interquartile range: 13.0-30.0] vs. 14.0 mm [6.0-18.0], p = 0.116). Complete TLE success was achieved in all patients with 3 (2-3) leads extracted per procedure. There were no postprocedure complications related to the presence of PE and no differences in terms of fluoroscopy time and need for advanced tools. In the group of positive pre-TLE CT, post-TLE scan confirmed the presence of silent PE in 14 patients (78%). There were no patients with new PE formation. Large vegetations (≥20 mm) tended to increase the risk of post-TLE subclinical PE (odds ratio 5.99 [95% confidence interval (CI): 0.93-38.6], p = 0.059). During a median 19.4 months follow-up, no re-infection of the implanted system was reported. Survival rates in patients with and without post-TLE PE were similar (hazard ratio: 1.11 [95% CI: 0.18-6.67], p = 0.909). CONCLUSION: Subclinical PE detected by CT was common in patients undergoing TLE with lead-related infective endocarditis and vegetations but was not associated with the complexity of the procedure or adverse outcomes. TLE procedure seems safe and feasible even in patients with large vegetations.


Asunto(s)
Desfibriladores Implantables , Endocarditis Bacteriana , Endocarditis , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Embolia Pulmonar , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Humanos , Marcapaso Artificial/efectos adversos , Prevalencia , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/epidemiología , Embolia Pulmonar/terapia , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...