Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Vet Sci ; 9: 946911, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35937293

RESUMEN

Electrical impedance tomography (EIT) is a non-invasive real-time non-ionising imaging modality that has many applications. Since the first recorded use in 1978, the technology has become more widely used especially in human adult and neonatal critical care monitoring. Recently, there has been an increase in research on thoracic EIT in veterinary medicine. Real-time imaging of the thorax allows evaluation of ventilation distribution in anesthetised and conscious animals. As the technology becomes recognised in the veterinary community there is a need to standardize approaches to data collection, analysis, interpretation and nomenclature, ensuring comparison and repeatability between researchers and studies. A group of nineteen veterinarians and two biomedical engineers experienced in veterinary EIT were consulted and contributed to the preparation of this statement. The aim of this consensus is to provide an introduction to this imaging modality, to highlight clinical relevance and to include recommendations on how to effectively use thoracic EIT in veterinary species. Based on this, the consensus statement aims to address the need for a streamlined approach to veterinary thoracic EIT and includes: an introduction to the use of EIT in veterinary species, the technical background to creation of the functional images, a consensus from all contributing authors on the practical application and use of the technology, descriptions and interpretation of current available variables including appropriate statistical analysis, nomenclature recommended for consistency and future developments in thoracic EIT. The information provided in this consensus statement may benefit researchers and clinicians working within the field of veterinary thoracic EIT. We endeavor to inform future users of the benefits of this imaging modality and provide opportunities to further explore applications of this technology with regards to perfusion imaging and pathology diagnosis.

2.
Res Vet Sci ; 135: 162-166, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33524826

RESUMEN

We evaluated the agreement between oscillometric and direct blood pressure monitors in anesthetized dogs and evaluated the ability of the oscillometric method to detect MAP <60 mmHg. Forty client-owned dogs, three months to 14 years old, 4.6-50.2 kg, under general anesthesia were studied. Systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures were measured directly via an arterial catheter and with an oscillometric cuff (Cardell Touch monitor). Paired values were compared with mixed effect models. Bias and limits of agreement (LOA) were calculated. The sensitivity and false negative rate to detect hypotension (invasive MAP <60 mmHg) using an oscillometric MAP <60 and < 70 mmHg were calculated. A receiver operating characteristics (ROC) curve was constructed and the area under the curve calculated. SAP and DAP differed between methods (both P < 0.001), but MAP did not (P = 0.5). Bland-Altman plots showed small biases but wide LOA for all variables. The sensitivity to detect hypotension was 40% with a false negative rate of 60% when using an oscillometric MAP <60 mmHg, and 68% and 32%, respectively, with a MAP <70 mmHg. The area under the ROC curve for MAP was 0.82. While the oscillometric MAP did not differ from invasive values, the device failed to recognize hypotensive events when 60 mmHg was used as the threshold to detect hypotension. Higher MAP values increased the ability to correctly recognize hypotension, but at the expense of a higher incidence of false positives.


Asunto(s)
Determinación de la Presión Sanguínea/veterinaria , Monitores de Presión Sanguínea/veterinaria , Enfermedades de los Perros/diagnóstico , Hipotensión/veterinaria , Oscilometría/veterinaria , Animales , Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea/estadística & datos numéricos , Perros , Femenino , Hipotensión/diagnóstico , Masculino , Oscilometría/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...