Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 186
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38719632

RESUMEN

BACKGROUND: The ACURATE neo2 transcatheter aortic valve was developed to improve paravalvular leak (PVL) rates while maintaining low rates of conduction disturbances and permanent pacemaker implantation (PPMI) seen with its predecessor. We aimed to compare conduction disturbances rates of transcatheter aortic valve replacement (TAVR) using ACURATE Neo2 with other commonly used valves. METHODS: A retrospective analysis of the Israeli TAVR registry between the years 2014-2023 was performed to compare conduction disturbances and PVL rates, and procedural outcomes, among patients treated with ACURATE neo2, Edwards Sapien 3 (S3), and Evolut PRO valves. Propensity score matching was performed to compare groups with similar characteristics. RESULTS: Following exclusion of patients with non-femoral access, unknown valve type, older-generation valves, and less commonly used valves or (n = 4387), our analysis included 3208 patients undergoing TAVR using ACURATE neo2, Edwards S3, and Evolut PRO valves. Propensity matched groups comprised 169 patients each. Rates of any conduction disturbances [left bundle branch block (LBBB), atrioventricular block, or PPMI] were lower in the ACURATE neo2 group compared to both other valves [15.8 %, S3-37.5 % (p < 0.001), Evolut PRO-27.5 % (p = 0.02)] as were LBBB rates [9.0 %, S3-31.3 % (p < 0.001); Evolut PRO-20.1 % (p = 0.01). Atrioventricular block and PPMI rates were lower without statistical significance, as were rates of above-moderate PVL. CONCLUSIONS: In this analysis, TAVR using ACURATE neo2 was associated with a lower composite rate of conduction disturbances in comparison to the Evolut PRO and Edwards S3 valves, mainly due to lower left bundle branch block rates, with non-significantly lower rates of PPMI and PVL.

2.
Cardiology ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38679011

RESUMEN

Introduction Coronary microvascular disease (CMD) is common in patients with and without obstructive epicardial coronary artery disease (CAD). Risk factors for the development of CMD have not been fully elucidated, and data regarding sex associated differences in traditional cardiovascular risk factors for obstructive CAD in patients with CMD are lacking. Methods In this single center, prospective registry, we enrolled patients with non-obstructive CAD undergoing clinically indicated invasive assessment of coronary microvascular function between November 2019 and March 2023. Associations between coronary microvascular dysfunction, traditional cardiovascular risk factors, and sex were assessed using univariate and multivariate regression models. Results Overall, 245 patients with non-obstructive CAD were included in the analysis (62.9% female; median age 68 (interquartile range [IQR]: 59,75). Microvascular dysfunction was diagnosed in 141 patients (57.5%). The prevalence of microvascular dysfunction was similar in women and men (59.0% vs. 57.0%; p=0.77). No association was found between traditional risk factors for coronary atherosclerosis and CMD regardless of whether CMD was structural or functional. In women, but not in men, older age and the presence of previous ischemic heart disease were associated with lower coronary flow reserve (CFR) (ß=-0.29; p<0.01 and ß=-0.15; p=0.05, respectively) and lower resistive reserve ratio (RRR) (ß=-0.28; p<0.01 and ß=-0.17; p=0.04, respectively). Conclusion For the entire population, no association was found between coronary microvascular dysfunction and traditional risk factors for coronary atherosclerosis. In women only, older age and previous ischemic heart disease were associated with coronary microvascular dysfunction. Larger studies are needed to elucidate risk factors for CMD.

3.
Am J Med ; 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38485108

RESUMEN

BACKGROUND: Coronary microvascular disease (CMD) is common in patients with and without obstructive coronary artery disease, and is associated with adverse clinical outcomes. Respiratory-related variables are associated with pulmonary and systemic microvascular dysfunction, while evidence about their relationship with CMD is limited. We aim to evaluate respiratory-related variables as risk factors of CMD. METHODS: This is an observational, single-center study enrolling consecutive patients undergoing invasive evaluation of coronary microvascular function in the catheterization laboratory. Patients with evidence of obstructive coronary artery disease or with missing data were excluded. Associations between respiratory-related variables and indices of CMD were assessed using univariate and multivariate regression models. RESULTS: Overall, 266 patients (mean age 67 ± 11 years, 59% females) were included in the current analysis. Of those, 155 (58%) had evidence of CMD. Among the respiratory variables, independent predictors of CMD were current smoking (adjusted odds ratio [AOR] 2.5; 95% confidence interval [CI], 1.2-5; P = .01) and obstructive sleep apnea (AOR 5.7; 95% CI, 1.2-26; P = .03), while chronic obstructive pulmonary disease was not. Among ever-smokers, higher smoking pack-years was an independent risk factor for CMD (median 35 vs 25 pack-years, AOR 1.09; 95% CI, 1.04-1.13; P < .01), and was associated with higher rates of pathologic index of microcirculatory resistance and resistive reserve ratio. CONCLUSION: In patients undergoing invasive coronary microvascular evaluation, current smoking and obstructive sleep apnea are independently associated with CMD. Among smokers, higher pack-years is a strong predictor for CMD. Our findings should raise awareness for prevention and possible treatment options.

4.
Am J Cardiol ; 202: 17-23, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37413702

RESUMEN

Early recognition of deteriorating left ventricular function plays a key prognostic role in patients with aortic stenosis (AS). First-phase ejection fraction (EF1), the ejection fraction (EF) up to time of maximal contraction, has been suggested for detection of early left ventricular dysfunction in patients with AS with preserved EF. This work aims to evaluate the predictive value of EF1 for assessment of long-term survival in patients with symptomatic severe AS and preserved EF who undergo transcatheter aortic valve implantation (TAVI). We included 102 consecutive patients (median age 84 years [interquartile range 80 to 86 years]) who underwent TAVI between 2009 and 2011. Patients were retrospectively stratified into tertiles by EF1. Device success and procedural complications were defined according to the Valve Academic Research Consortium-3 criteria. Mortality data were retrieved from a computerized interface of the Israeli Ministry of Health. Baseline characteristics, co-morbidities, clinical presentation, and echocardiographic findings were similar among groups. The groups did not differ significantly regarding device success and in-hospital complications. During a potential follow-up period of >10 years, 88 patients died. Kaplan-Meier analysis (log-rank p = 0.017) followed by multivariable Cox regression analysis showed that EF1 predicted long-term mortality independently, either as continuous variable (hazard ratio 1.04, 95% confidence interval 1.01 to 1.07, p = 0.012) or for each decrease in tertile group (hazard ratio 1.40, 95% confidence interval 1.05 to 1.86, p = 0.023). In conclusion, low EF1 is associated with a significant decrease in adjusted hazard for long-term survival in patients with preserved EF who undergo TAVI. Low EF1 might delineate a population at great risk who would benefit from prompt intervention.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Volumen Sistólico , Estudios Retrospectivos , Pronóstico , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento
5.
Can J Cardiol ; 39(11): 1528-1534, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37419247

RESUMEN

BACKGROUND: There are conflicting data regarding the efficacy and safety of suture vs plug-based vascular closure devices (VCDs) for large-bore catheter management in patients undergoing transcatheter aortic valve replacement (TAVR). We compared the rates of vascular complications (VCs) associated with 2 commonly used VCDs in a large cohort of patients undergoing TAVR. METHODS: We conducted a single-centre, all-comer, prospective registry study, enrolling patients undergoing TAVR for symptomatic severe aortic stenosis (AS) between the years 2009 and 2022. Clinical outcomes were compared between patients undergoing closure of the femoral access point using the MANTA VCD (M-VCD) (Teleflex, Wayne, PA) vs the ProGlide VCD (P-VCD) (Abbott Vascular, Abbott Park, IL). The main outcome measures were researcher adjudicated events of VARC-2 defined major and minor VCs. RESULTS: Overall, 2368 patients were enrolled in the registry; 1315 (51.0% male, 81.0 ± 7.0 years) patients were included in the current analysis. P-VCD was used in 813 patients, whereas M-VCD was used in 502 patients. In-hospital VCs were more frequent in the M-VCD vs the P-VCD group (17.3% vs 9.8%; P < 0.001). This outcome was mainly driven by elevated rates of minor VCs in the M-VCD group, whereas no significant difference was observed for major VCs (15.1% vs 8.4%; P < 0.001 and 2.2% vs 1.5%; P = 0.33, respectively). CONCLUSIONS: In patients undergoing TAVR for severe AS, M-VCD was associated with higher rates of VCs. This outcome was mainly driven by minor VCs. The rate of major VCs was low in both groups.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades Cardiovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Arteria Femoral/cirugía , Dispositivos de Cierre Vascular/efectos adversos , Enfermedades Cardiovasculares/etiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/cirugía , Técnicas Hemostáticas/efectos adversos
6.
Clin Cardiol ; 46(3): 328-335, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36660883

RESUMEN

BACKGROUND: Cardiotoxicity, defined mainly as left ventricle (LV) dysfunction, is a significant side effect of anthracyclines (ANT) therapy. The need for an early simple marker to identify patients at risk is crucial. A high neutrophil-to-lymphocyte ratio (NLR) has been associated with poor prognosis in cancer patients; however, its role as a predictor for cardiotoxicity development is unknown. OBJECTIVE: Evaluating whether elevated NLR, during ANT exposure, plays a predictive role in the development of cardiotoxicity as defined by LV global longitudinal strain (LV GLS) relative reduction (≥10%). METHODS AND RESULTS: Data were prospectively collected as part of the Israel Cardio-Oncology Registry. A total of 74 female patients with breast cancer, scheduled for ANT therapy were included. NLR levels were assessed at baseline (T1) and during ANT therapy (T2). All patients underwent serial echocardiography at baseline (T1) and after the completion of ANT therapy (T3). NLR ≥ 2.58 at T2 was found to be the optimal predictive cutoff for LV GLS deterioration. A relative LV GLS reduction ≥10% was significantly more common among patients with high NLR (50% vs. 20%, p = .009). NLR ≥ 2.58 at T2 increases the risk for LV GLS reduction by fourfold (odds ratio [OR]: 4.63, 95% confidence interval [CI]: 1.29-16.5, p = .02), with each increase of 1-point NLR adding an additional 15% risk (OR: 1.15, 95% CI: 1.01-1.32, p = .046). CONCLUSIONS: Our study provides novel data that high NLR levels, during ANT exposure, have an independent association with the development of LV dysfunction. Routine surveillance of NLR may be an effective means of risk-stratifying.


Asunto(s)
Neoplasias de la Mama , Disfunción Ventricular Izquierda , Humanos , Femenino , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/complicaciones , Cardiotoxicidad/complicaciones , Cardiotoxicidad/tratamiento farmacológico , Disfunción Ventricular Izquierda/inducido químicamente , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/complicaciones , Antraciclinas/efectos adversos , Neutrófilos , Función Ventricular Izquierda
7.
Biosensors (Basel) ; 12(10)2022 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-36290968

RESUMEN

BACKGROUND: The cost of heart failure hospitalizations in the US alone is over USD 10 billion per year. Over 4 million Americans are hospitalized every year due to heart failure (HF), with a median length of stay of 4 days and an in-hospital mortality rate that exceeds 5%. Hospitalizations of patients with HF can be prevented by early detection of lung congestion. Our study assessed a new contact-free optical medical device used for the early detection of lung congestion. METHODS: The Gili system is an FDA-cleared device used for measuring chest motion vibration data. Lung congestion in the study was assessed clinically and verified via two cardiologists. An algorithm was developed using machine learning techniques, and cross-validation of the findings was performed to estimate the accuracy of the algorithm. RESULTS: A total of 227 patients were recruited (101 cases vs. 126 controls). The sensitivity and specificity for the device in our study were 0.91 (95% CI: 0.86-0.93) and 0.91 (95% CI: 0.87-0.94), respectively. In all instances, the observed estimates of PPVs and NPVs were at least 0.82 and 0.90, respectively. The accuracy of the algorithm was not affected by different covariates (including respiratory or valvular conditions). CONCLUSIONS: This study demonstrates the efficacy of a contact-free optical device for detecting lung congestion. Further validation of the study results across a larger and precise scale is warranted.


Asunto(s)
Insuficiencia Cardíaca , Dispositivos Ópticos , Edema Pulmonar , Humanos , Estados Unidos , Proyectos Piloto , Edema Pulmonar/diagnóstico , Pulmón , Insuficiencia Cardíaca/diagnóstico
8.
J Int Med Res ; 50(10): 3000605221127099, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36268757

RESUMEN

OBJECTIVE: Inflammation is associated with atherogenesis. Although a higher neutrophil count is associated with the plaque burden, the role of neutrophil activation is unclear. Human neutrophil peptides 1-3 (HNP1-3) are a risk factor for atherogenesis in bench models and are elevated in human atheromas. This study aimed to examine the association between skin HNP1-3 deposition and the severity of coronary artery disease (CAD), including long-term outcomes. METHODS: HNP1-3 levels were immunohistochemically quantified in skin biopsies, which were prospectively taken from 599 consecutive patients before clinically indicated coronary angiography. Established cardiovascular risk factors and blood markers for atheroinflammation were obtained. CAD severity and the incidence of repeat revascularization and mortality at 48 months of follow-up were assessed in relation to HNP1-3 levels. RESULTS: The risk of CAD was independently associated with age and HNP1-3 in the entire cohort (F = 0.71 and F = 7.4, respectively). Additionally, HNP1-3 levels were significantly associated with myocardial necrosis (R = 0.26). At the follow-up, high HNP1-3 levels negatively affected mortality (19.54%) and recurrent revascularization (8.05%). CONCLUSION: HNP1-3 tissue deposition is positively associated with the severity of CAD, myonecrosis, and long-term sequelae. HNP1-3 levels may be suppressed using colchicine.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , alfa-Defensinas , Humanos , Estudios Prospectivos , Estudios Longitudinales , Estudios de Cohortes , Factores de Riesgo , Fenotipo , Colchicina
9.
Life (Basel) ; 12(9)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36143403

RESUMEN

Immune checkpoint inhibitor (ICI) and coronavirus disease 2019 (COVID-19) vaccine-induced myocarditis possibly share common mechanisms secondary to overactivation of the immune system. We aimed to compare the presenting characteristics of ICIs and COVID-19 vaccine-induced myocarditis. We performed a retrospective analysis of characteristics of patients diagnosed with either ICIs or COVID-19 vaccine-induced myocarditis and compared the results to a control group of patients diagnosed with acute viral myocarditis. Eighteen patients diagnosed with ICIs (ICI group) or COVID-19 vaccine (COVID-19 vaccine group)-induced myocarditis, and 20 patients with acute viral myocarditis (Viral group) were included. The ICI group presented mainly with dyspnea vs. chest pain and fever among the COVID-19 vaccine and Viral groups. Peak median high sensitivity Troponin I was markedly lower in the ICI group (median 619 vs. 15,527 and 7388 ng/L, p = 0.004). While the median left ventricular (LV) ejection fraction was 60% among all groups, the ICI group had a lower absolute mean LV global longitudinal strain (13%) and left atrial conduit strain (17%), compared to the COVID-19 vaccine (17% and 30%) and Viral groups (18% and 37%), p = 0.016 and p = 0.001, respectively. Despite a probable similar mechanism, ICI-induced myocarditis's presenting characteristics differed from COVID-19 vaccine-induced myocarditis.

10.
Life (Basel) ; 12(8)2022 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-36013454

RESUMEN

The association between anthracycline (ANT) and left ventricle (LV) dysfunction is well known; however, data regarding its direct effect on cardiac valve function is limited. We aimed to evaluate how ANT therapy affected valvular function in patients diagnosed with breast cancer. Data were prospectively collected as part of the Israel Cardio-Oncology Registry (ICOR). Patients underwent echocardiography exams at baseline (T1), during ANT therapy (T2), and after completion within 3 months (T3) and 6 months (T4). A total of 141 female patients were included, with a mean age of 51 ± 12 years. From T1 to T4, we observed a significant deterioration in LV ejection fraction (60.2 ± 1.5 to 59.2 ± 2.7%, p = 0.0004) and LV global longitudinal strain (−21.6 (−20.0−−23.0) to −20.0 (−19.1−−21.1)%, p < 0.0001)), and an increase in LV end-systolic diameter (25 (22−27) to 27 (24−30) mm, p < 0.0001). We observed a significant increase in the incidence of new mitral regurgitation (MR) development (4 to 19%, p < 0.0001), worsening with concomitant trastuzumab therapy (6% to 31%, p = 0.003), and a trend for tricuspid regurgitation development (4% to 8%, p = 0.19). ANT therapy is associated with the development of a new valvular disease, mainly MR, which may imply the need for a valvular focus in the monitoring of cancer patients.

11.
Coron Artery Dis ; 33(5): 354-361, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35880559

RESUMEN

BACKGROUND: Implantation of drug eluting stents (DES) is the mainstay treatment for patients requiring percutaneous coronary intervention (PCI). The polymer coating of DES has been associated with inflammatory response, increased arterial injury and long-term in-stent restenosis and thrombosis. Polymer-free stents (PFS) were designed to overcome limitations of polymer-coated stents (PCS). Our aim was to compare clinical outcomes of patients undergoing PCI with PFS versus contemporary PCS. METHODS: This is a prospective, open-label registry study enrolling consecutive all-comers patients admitted to a single center and undergoing PCI using contemporary DES. Clinical outcomes were compared between patients treated with PFS and PCS. The primary endpoint was target lesion revascularization (TLR) at 12 months. Subgroup analyses were conducted for diabetic and nondiabetic patients. RESULTS: Overall, 1664 patients were included: 928 (55.8%) of which were treated with PFS and 736 (44.2%) with PCS for 2046 and 1462 lesions, respectively. At 12 months, TLR rates were not significantly different between the groups (1.7% vs. 2.3% for PFS and PCS, respectively, P = 0.48). The use of PFS did not improve clinical outcomes among diabetic patients in comparison with PCS. Target vessel revascularization and major adverse cardiac events rates were also similar between groups, regardless of diabetes status. CONCLUSION: Newer generation DES offer excellent results in diabetic and nondiabetic patients without significant differences in outcomes between PCS and PFS.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/efectos adversos , Resultado del Tratamiento
12.
Isr Med Assoc J ; 24(4): 229-234, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35415981

RESUMEN

BACKGROUND: Neutrophil-to-lymphocyte ratio (NLR) is a simple and cost-effective marker of inflammation. This marker has been shown to predict cardiac arrhythmias, progression of valvular heart disease, congestive heart failure decompensation, acute kidney injury, and mortality in cardiovascular patients. The pathologic process of aortic stenosis includes chronic inflammation of the valve and therefore biomarkers of inflammation might offer additive prognostic value. OBJECTIVES: To evaluate NLR and its association with long term mortality in transcatheter aortic valve implantation (TAVI) patients. METHODS: We evaluated data of 1152 consecutive patient from the Tel Aviv Medical Center TAVI registry who underwent TAVI. Data included baseline clinical, demographic, and echocardiographic findings; procedural complications; and post-procedure mortality. Patients were compared by using the median NLR value (4.1) and evaluated for long-term mortality. RESULTS: Patients with NLR above the median had higher mortality rates (26.4% vs. 16.3%, P < 0.001) at 3 years post-procedure. A multivariable analysis found NLR to be an independent risk factor for mortality (hazard ratio = 1.47, 95% confidence interval 1.09-1.99, P = 0.013). In addition, high NLR was linked to complicationsduring and after the procedure. CONCLUSIONS: NLR is an independent prognostic marker among TAVI patients. This marker may represent an increased inflammatory response and should be added to previous known prognostic factors.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Humanos , Inflamación/complicaciones , Linfocitos , Neutrófilos , Pronóstico , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
13.
Cardiology ; 147(4): 367-374, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35358973

RESUMEN

INTRODUCTION: Ostial coronary lesions are a subset of proximal coronary lesions, which are relatively more difficult to treat and were associated with worse clinical outcomes in the early percutaneous coronary intervention (PCI) era. Data regarding the outcomes of ostial lesions' PCI in the contemporary era are lacking. METHODS: We conducted a single-center, all-comer, prospective registry study, enrolling patients undergoing PCI with the use of contemporary drug-eluting stents (DES) between July 2016 and February 2018. Included in the present analysis were only patients treated for proximal lesions. Clinical outcomes were compared between patients undergoing PCI of ostial versus proximal nonostial lesions. The primary endpoint was target vessel revascularization (TVR). Secondary endpoints included target lesion revascularization (TLR) and major cardiovascular adverse events (MACE) at 12 months. RESULTS: A total of 334 (84.7% male, 67.3 ± 10.7 years) patients were included, of which 91 patients were treated for ostial lesions and 243 were treated for proximal nonostial lesions. Baseline and procedural characteristics were similar between the two groups. At 12 months, TVR and TLR were numerically higher among patients undergoing PCI of ostial versus nonostial lesions without reaching statistical significance (5.5% vs. 3.3%; p = 0.35 and 4.4% vs. 2.5%; p = 0.47, respectively). The rate of MACE was similar between the two groups. CONCLUSION: In patients undergoing PCI with the use of contemporary DES, clinical outcomes were similar among patients treated for ostial compared to proximal nonostial lesions. Larger studies are required to further evaluate the performance of contemporary DES in this subset of lesions.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
Life (Basel) ; 12(2)2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-35207578

RESUMEN

BACKGROUND: Anthracycline (ANT) is the most recognized therapy known to cause cardiotoxicity, mainly left ventricle (LV) dysfunction. Global Longitudinal Strain (GLS) is the optimal tool for assessment of subclinical LV dysfunction. Right ventricle (RV) function has been recognized as an independent factor for cardiac outcomes; however, data evaluating RV GLS is limited. We aimed to evaluate the change in RV GLS following ANT therapy. METHODS: The study cohort is part of the Israel Cardio-Oncology Registry (ICOR). All patients performed echocardiography before (T1) and at the end (T3) of ANT therapy. A significant reduction was defined as a relative reduction of ≥10% in RV GLS values. RESULTS: The study included 40 female patients with breast cancer treated with ANT. During follow-up, both RV GLS and free wall longitudinal strain systolic peak (RV FWLS PK) decreased significantly (p < 0.001 and p = 0.002). Altogether, 30 (75%) and 23 (58%) patients showed RV GLS and RV FWLS PK ≥ 10% relative reduction. At T3, LV ejection fraction and LV GLS were within normal range. CONCLUSIONS: RV GLS and RV FWLS PK reduction following ANT exposure is extremely frequent, comparing to LV GLS reduction.

15.
J Clin Med ; 11(3)2022 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-35160335

RESUMEN

The accumulation of contrast media in the kidneys might lead to contrast-induced acute kidney injury. In this prospective, controlled observational study, we aimed to evaluate whether forced diuresis with matched isotonic intravenous hydration prevents the accumulation of contrast media in the kidneys of patients undergoing cardiac interventional procedures. We compared the intensity of contrast media accumulation as observed in nephrograms following these procedures, with and without peri-procedural controlled renal flushing. The study group consisted of 25 patients with impaired renal function treated with the RenalGuard system. The two control groups included 25 patients with normal kidney function and 8 patients with impaired renal function undergoing similar procedures with routine pre-procedural hydration, but without controlled renal flushing. Renal contrast media accumulation at the end of each procedure was scored by blinded cardiologists. The renal contrast accumulation score (CAS) in the study group was significantly lower, with a median score of 0 (IQR (0-0)) compared with 1.5 (IQR (1-2)) in the normal renal function control group and 1 (IQR (0.38-1.62)) in the impaired renal function control group (p < 0.001 and 0.003, respectively). In a multivariate analysis of CAS, RenalGuard treatment was independently associated with lower CAS compared to both control groups. In conclusion, RenalGuard use prevents renal contrast accumulation in patients with impaired renal function undergoing cardiac procedures with intra-arterial contrast media injection.

16.
Eur Heart J Cardiovasc Imaging ; 23(8): 1055-1065, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-34542601

RESUMEN

AIMS: We aim to assess changes in routine echocardiographic and longitudinal strain parameters in patients recovering from Coronavirus disease 2019 during hospitalization and at 3-month follow-up. METHODS AND RESULTS: Routine comprehensive echocardiography and STE of both ventricles were performed during hospitalization for acute coronavirus disease 2019 (COVID-19) infection as part of a prospective pre-designed protocol and compared with echocardiography performed ∼3 months after recovery in 80 patients, using a similar protocol. Significantly improved right ventricle (RV) fractional area change, longer pulmonary acceleration time, lower right atrial pressure, and smaller RV end-diastolic and end-systolic area were observed at the recovery assessment (P < 0.05 for all). RV global longitudinal strain improved at the follow-up evaluation (23.2 ± 5 vs. 21.7 ± 4, P = 0.03), mostly due to improvement in septal segments. Only eight (10%) patients recovering from COVID-19 infection had abnormal ejection fraction (EF) at follow-up. However, LV related routine (E, E/e', stroke volume, LV size), or STE parameters did not change significantly from the assessment during hospitalization. A significant proportion [36 (45%)] of patients had some deterioration of longitudinal strain at follow-up, and 20 patients (25%) still had abnormal LV STE ∼3 months after COVID-19 acute infection. CONCLUSION: In patients previously discharged from hospitalization due to COVID-19 infection, RV routine echocardiographic and RV STE parameters improve significantly concurrently with improved RV haemodynamics. In contrast, a quarter of patients still have LV systolic dysfunction based on STE cut-offs. Moreover, LV STE does not improve significantly, implying subclinical LV dysfunction may be part and parcel of recovering from COVID-19 infection.


Asunto(s)
COVID-19 , Disfunción Ventricular Derecha , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Estudios Longitudinales , Estudios Prospectivos , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
17.
Int J Cardiovasc Imaging ; 38(2): 289-296, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34498200

RESUMEN

Myocardial perfusion defect, assessed with single photon emission computed tomography (SPECT), is useful for patient management and risk stratification. Left ventricle Global Longitudinal Strain (LV GLS) has gained interest for observing subclinical LV dysfunction. We aimed to investigate the utility of LV GLS in evaluating myocardial perfusion defect. A retrospective study of all patients who underwent SPECT and LV GLS at Tel Aviv Sourasky medical center. Overall, 86 patients were included. LV GLS and SPECT correlated in the base and apex sections for infraction, and in the apex only for ischemia. Adjusted analysis showed a significant correlation between LV GLS of both the mid and apical section and infarction by SPECT, but no association with ischemia. No associations were found by arterial supply territory. A sub-analysis of patients without left bundle branch block (LBBB) strengthened the correlations, with a 58-70% higher chance of both fixed and reversible defects for every 1-unit decrease LV GLS in the mid and apical sections. LV GLS effectively evaluated the presence of infarction by SPECT in the mid and apical sections, particularly in patients without LBBB. Due to its high availability, LV GLS may have a role in evaluating myocardial perfusion defect.


Asunto(s)
Ventrículos Cardíacos , Disfunción Ventricular Izquierda , Bloqueo de Rama , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Perfusión , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda
18.
Eur Heart J Digit Health ; 3(1): 105-113, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36713997

RESUMEN

Aims: Atrial fibrillation (AF) is a major cause of morbidity and mortality. Current guidelines support performing electrocardiogram (ECG) screenings to spot AF in high-risk patients. The purpose of this study was to validate a new algorithm aimed to identify AF in patients measured with a recent FDA-cleared contact-free optical device. Methods and results: Study participants were measured simultaneously using two devices: a contact-free optical system that measures chest motion vibrations (investigational device, 'Gili') and a standard reference bed-side ECG monitor (Mindray®). Each reference ECG was evaluated by two board certified cardiologists that defined each trace as: regular rhythm, AF, other irregular rhythm or indecipherable/missing. A total of 3582, 30-s intervals, pertaining to 444 patients (41.9% with a history of AF) were made available for analysis. Distribution of patients with active AF, other irregular rhythm, and regular rhythm was 16.9%, 29.5%, and 53.6% respectively. Following application of cross-validated machine learning approach, the observed sensitivity and specificity were 0.92 [95% confidence interval (CI): 0.91-0.93] and 0.96 (95% CI: 0.95-0.96), respectively. Conclusion: This study demonstrates for the first time the efficacy of a contact-free optical device for detecting AF.

19.
Can J Kidney Health Dis ; 8: 20543581211018029, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34158963

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR), although associated with an increased risk for acute kidney injury (AKI), may also result in improvement in renal function. OBJECTIVE: The aim of this study is to evaluate the magnitude of kidney function improvement (KFI) after TAVR and to assess its significance on long-term mortality. DESIGN: This is a prospective single center study. SETTING: The study was conducted in cardiology department, interventional unit, in a tertiary hospital. PATIENTS: The cohort included 1321 patients who underwent TAVR. MEASUREMENTS: Serum creatinine level was measured at baseline, before the procedure, and over the next 7 days or until discharge. METHODS: Kidney function improvement was defined as the mirror image of AKI, a reduction in pre-procedural to post-procedural minimal creatinine of more than 0.3 mg/dL, or a ratio of post-procedural minimal creatinine to pre-procedural creatinine of less than 0.66, up to 7 days after the procedure. Patients were categorized and compared for clinical endpoints according to post-procedural renal function change into 3 groups: KFI, AKI, or preserved kidney function (PKF). The primary endpoint was long-term all-cause mortality. RESULTS: The incidence of KFI was 5%. In 55 out of 66 patients patients, the improvement in kidney function was minor and of unclear clinical significance. Acute kidney injury occurred in 19.1%. Estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2 was a predictor of KFI after multivariable analysis (odds ratio = 0.93 to develop KFI; confidence interval [95% CI]: 0.91-0.95, P < .001). Patients in the KFI group had a higher Society of Thoracic Surgery (STS) score than other groups. Mortality rate did not differ between KFI group and PKF group (43.9% in KFI group and 33.8% in PKF group) but was significantly higher in the AKI group (60.7%, P < .001). LIMITATIONS: The following are the limitations: heterozygous definitions of KFI within different studies and a single center study. Although data were collected prospectively, analysis plan was defined after data collection. CONCLUSIONS: Improvement in kidney function following TAVR was not a common phenomenon in our cohort and did not reduce overall mortality rate.


CONTEXTE: L'implantation transcathéter de valvule aortique (ITVA), bien qu'elle soit associée à un risque accru d'insuffisance rénale aiguë (IRA), est susceptible d'améliorer la fonction rénale. OBJECTIFS: Évaluer l'ampleur de l'amélioration de la fonction rénale (AFR) après une ITVA et évaluer son incidence sur le taux de mortalité à long terme. TYPE D'ÉTUDE: Étude prospective menée dans un seul centre hospitalier. CADRE: Le service de cardiologie, unité interventionnelle, d'un centre de soins tertiaires. SUJETS: La cohorte était constituée de 1 321 patients ayant subi une ITVA. MESURES: Le taux de créatinine sérique a été mesuré à l'inclusion, avant l'intervention et pour les 7 jours suivants, ou jusqu'au congé du patient. MÉTHODOLOGIE: L'AFR a été définie comme l'image miroir de l'IRA, soit une réduction de plus de 0,3 mg/dl du taux de créatinine après l'intervention par rapport au taux minimum de créatinine mesuré pré-ITVA, ou un rapport entre la créatinine minimale post-ITVA et la créatinine pré-ITVA inférieur à 0,66 jusqu'à 7 jours après l'intervention. Les patients ont été classés en trois groupes et comparés selon des critères cliniques en fonction de la modification de la fonction rénale après l'intervention : un groupe AFR, un groupe IRA et un groupe « fonction rénale préservée ¼ (FRP). Le critère principal était la mortalité toutes causes confondues. RÉSULTATS: L'incidence d'une AFR était de 5 % et elle s'est avérée mineure et d'importance clinique incertaine pour 55 des 66 patients concernés. La proportion de patients atteints d'IRA était de 19,1 %. Après l'analyse multivariée, un débit de filtration glomérulaire estimé (DFGe) inférieur à 60 ml/min/1,73 m2 s'est avéré un facteur prédictif de l'AFR [rapport de cotes pour une AFR : 0,93 (IC : 0,91-0,95; p < 0,001)]. Les patients du groupe AFR présentaient un score de la Society of Thoracic Surgery (STS) plus élevé que ceux des autres groupes. Le taux de mortalité était similaire pour les groupes AFR et FRP (respectivement 43,9 % et 33,8 %), mais s'est avéré significativement plus élevé dans le groupe IRA (60,7 %; p < 0,001). LIMITES: Manque de consensus autour de la définition d'une amélioration de la fonction rénale dans les différentes études.Étude menée dans un seul centre.Bien que les données aient été recueillies de façon prospective, le plan d'analyse n'a été défini qu'après la collecte des données. CONCLUSION: L'amélioration de la fonction rénale après l'ITVA n'était pas un phénomène courant dans notre cohorte et n'a pas permis de réduire le taux de mortalité global.

20.
J Immunother ; 44(5): 179-184, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33950028

RESUMEN

The widespread use of immune checkpoint inhibitors (ICI) has become a mainstay of care for a variety of malignancies. However, these therapies portend a range of adverse effects, including a potentially fatal form of cardiotoxicity which to date has not been elucidated. We aimed to evaluate the baseline characteristics of ICI-mediated cardiotoxicity. We performed a retrospective study evaluating patients treated with ICI who performed at least 2 echocardiography examinations, before and after the initiation of ICI. Cardiotoxicity was defined as Cancer Therapeutics-related Cardiac Dysfunction (CTRCD) development, with an absolute left ventricular ejection fraction reduction of >10%, to a value <53%. Fifty-two patients were included with a male preponderance (65%) and a mean age of 66 (±12) years. Twelve (23%) patients developed CTRCD, of which 2 patients were diagnosed with myocarditis. Among the CTRCD group, patients tended to be older and more likely to have baseline diastolic dysfunction: lower e' septal (P=0.026), higher E/e' septal (P=0.035), and a trend of E/e' average (P=0.076). All-cause and cardiovascular hospitalizations were significantly more common among the CTRCD group (P=0.028 and 0.001, respectively). Higher prevalence of cardiovascular mortality was observed among the CTRCD group (25% vs. 2%, P=0.034). We evaluated the development of CTRCD among patients treated with ICI therapies. Our findings suggest that baseline diastolic parameters may be associated with CTRCD development assisting in the early diagnosis of ICI-induced cardiac injury.


Asunto(s)
Cardiotoxicidad/diagnóstico , Cardiotoxicidad/etiología , Cardiopatías/diagnóstico , Cardiopatías/etiología , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Neoplasias/complicaciones , Anciano , Cardiotoxicidad/epidemiología , Comorbilidad , Susceptibilidad a Enfermedades , Ecocardiografía , Electrocardiografía , Femenino , Cardiopatías/epidemiología , Pruebas de Función Cardíaca , Humanos , Inhibidores de Puntos de Control Inmunológico/uso terapéutico , Masculino , Persona de Mediana Edad , Terapia Molecular Dirigida/efectos adversos , Terapia Molecular Dirigida/métodos , Neoplasias/tratamiento farmacológico , Evaluación de Resultado en la Atención de Salud , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...