Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med ; 119: 103300, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38325222

RESUMEN

PURPOSE: The aim of the present study, conducted by a working group of the Italian Association of Medical Physics (AIFM), was to define typical z-resolution values for different digital breast tomosynthesis (DBT) models to be used as a reference for quality control (QC). Currently, there are no typical values published in internationally agreed QC protocols. METHODS: To characterize the z-resolution of the DBT models, the full width at half maximum (FWHM) of the artifact spread function (ASF), a technical parameter that quantifies the signal intensity of a detail along reconstructed planes, was analyzed. Five different commercial phantoms, CIRS Model 011, CIRS Model 015, Modular DBT phantom, Pixmam 3-D, and Tomophan, were evaluated on reconstructed DBT images and 82 DBT systems (6 vendors, 9 models) in use at 39 centers in Italy were involved. RESULTS: The ASF was found to be dependent on the detail size, the DBT angular acquisition range, the reconstruction algorithm and applied image processing. In particular, a progressively greater signal spread was observed as the detail size increased and the acquisition angle decreased. However, a clear correlation between signal spread and angular range width was not observed due to the different signal reconstruction and image processing strategies implemented in the algorithms developed by the vendors studied. CONCLUSIONS: The analysis led to the identification of typical z-resolution values for different DBT model-phantom configurations that could be used as a reference during a QC program.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Mamografía , Mamografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Artefactos , Algoritmos
2.
Health Phys ; 104(1): 1-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23192082

RESUMEN

The goal of establishing prompt localization of the malignant spread or recurrence of a tumor has found a powerful solution in the definition of follow-up protocols, which include the indication for CT scans on an annual or semiannual basis. In the case of long-surviving patients, however, this approach will lead to a considerable integrated dose level over a period of several years after recovery from the illness. Pathologies treated primarily by surgery and/or chemotherapy have been considered, not taking into account cancers treated with adjuvant or radical radiotherapy. Given that the most likely protocols for these cancers often call for total body scans, an estimation of the consequent effective and organ doses can be performed with acceptable accuracy. The data acquired from five centers have been collected and the related effective and organ doses calculated by means of IMPACT software. Use of the effective dose concept, however, has lately become the subject of criticism, and the recently proposed Effective Risk Model has therefore also been applied. The evaluated absolute additional risk of second tumor induction ranges between 0.1% and 10%, depending primarily on age and pathology. These results depict this additional risk as an issue of significant importance for clinical practice. A revision of follow-up and scan parameter protocols, as well as the introduction of new algorithms for dose reduction, could significantly improve the risk-benefit ratio for all the pathologies studied.


Asunto(s)
Neoplasias Primarias Secundarias/diagnóstico por imagen , Neoplasias Primarias Secundarias/etiología , Neoplasias/mortalidad , Dosis de Radiación , Sobrevivientes , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Factores de Edad , Anciano , Niño , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...