Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
IEEE Trans Med Imaging ; 41(11): 2980-2990, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35584078

RESUMEN

Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues. Five fresh mastectomies containing microcalcifications were scanned at different X-ray energies and radiation doses using synchrotron radiation. Both bright-field (i.e. conventional phase-retrieved images) and dark-field images were extracted from the same data sets using different image processing methods. A quantitative analysis was performed in terms of visibility and contrast-to-noise ratio of microcalcifications. The results show that while the signal-to-noise and the contrast-to-noise ratios are lower, the visibility of the microcalcifications is more than two times higher in the dark-field images compared to the bright-field images. Dark-field images have also provided more accurate information about the size and shape of the microcalcifications.


Asunto(s)
Enfermedades de la Mama , Neoplasias de la Mama , Calcinosis , Humanos , Femenino , Mamografía/métodos , Calcinosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen
2.
Hear Res ; 327: 48-57, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25987505

RESUMEN

AIM: To explore morphological or electrophysiological evidence for the presence of endolymphatic hydrops (EH) in guinea pig cochleae in the first 3 months after cochlear implantation. METHODS: Dummy silastic electrodes were implanted atraumatically into the basal turn of scala tympani via a cochleostomy. Round window electrocochleography (ECochG) was undertaken prior to and after implantation. Animals survived for 1, 7, 28 or 72 days prior to a terminal experiment, when ECochG was repeated. The cochleae were imaged using micro-CT after post-fixing with osmium tetroxide to reveal the inner ear soft tissue structure. EH was assessed by visual inspection at a series of frequency specific places along the length of the cochlea, and the extent to which Reissner's membrane departed from its neutral position was quantified. Tissue response volumes were calculated. Using ECochG, the ratio of the summating potential to the action potential (SP/AP ratio) was calculated in response to frequencies between 2 and 32 kHz. RESULTS: There was minimal evidence of electrode trauma from cochlear implantation on micro-CT imaging. Tissue response volumes did not change over time. EH was most prevalent 7 days after surgery in implanted ears, as determined by visual inspection. Scala media areas were increased, as expected in cases of EH, over the first month after cochlear implantation. SP/AP ratios decreased immediately after surgery, but were elevated 1 and 7 days after implantation. CONCLUSIONS: EH is prevalent in the first weeks after implant surgery, even in the absence of significant electrode insertion trauma.


Asunto(s)
Cóclea/cirugía , Implantación Coclear/efectos adversos , Hidropesía Endolinfática/etiología , Estimulación Acústica , Animales , Audiometría de Respuesta Evocada , Umbral Auditivo , Cóclea/diagnóstico por imagen , Cóclea/fisiopatología , Implantación Coclear/instrumentación , Implantes Cocleares , Modelos Animales de Enfermedad , Hidropesía Endolinfática/diagnóstico , Hidropesía Endolinfática/fisiopatología , Potenciales Evocados , Cobayas , Factores de Tiempo , Microtomografía por Rayos X
3.
Rev Sci Instrum ; 84(6): 063703, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23822348

RESUMEN

This study realizes the concept of simultaneous micro-X-ray computed tomography and X-ray powder diffraction using a synchrotron beamline. A thin zinc metal foil was placed in the primary, monochromatic synchrotron beam to generate a divergent wave to propagate through the samples of interest onto a CCD detector for tomographic imaging, thus removing the need for large beam illumination and high spatial resolution detection. Both low density materials (kapton tubing and a piece of plant) and higher density materials (Egyptian faience) were investigated, and elemental contrast was explored for the example of Cu and Ni meshes. The viability of parallel powder diffraction using the direct beam transmitted through the foil was demonstrated. The outcomes of this study enable further development of the technique towards in situ tomography∕diffraction studies combining micrometer and crystallographic length scales, and towards elemental contrast imaging and reconstruction methods using well defined fluorescence outputs from combinations of known fluorescence targets (elements).


Asunto(s)
Colorantes Fluorescentes/química , Metales/química , Difracción de Polvo/instrumentación , Sincrotrones , Tomografía por Rayos X/instrumentación , Difracción de Rayos X/instrumentación
4.
Cell Death Dis ; 3: e362, 2012 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-22874999

RESUMEN

In this paper we describe novel and specific roles for the apoptotic regulators Bcl2 and Bim in hearing and stapes development. Bcl2 is anti-apoptotic while Bim is pro-apoptotic. Characterization of the auditory systems of mice deficient for these molecules revealed that Bcl2⁻/⁻ mice suffered severe hearing loss. This was conductive in nature and did not affect sensory cells of the inner ear, with cochlear hair cells and neurons present and functional. Bcl2⁻/⁻ mice were found to have a malformed, often monocrural, porous stapes (the small stirrup-shaped bone of the middle ear), but a normally shaped malleus and incus. The deformed stapes was discontinuous with the incus and sometimes fused to the temporal bones. The defect was completely rescued in Bcl2⁻/⁻Bim⁻/⁻ mice and partially rescued in Bcl2⁻/⁻Bim⁺/⁻ mice, which displayed high-frequency hearing loss and thickening of the stapes anterior crus. The Bcl2⁻/⁻ defect arose in utero before or during the cartilage stage of stapes development. These results implicate Bcl2 and Bim in regulating survival of second pharyngeal arch or neural crest cells that give rise to the stapes during embryonic development.


Asunto(s)
Pérdida Auditiva Conductiva/metabolismo , Proteínas Proto-Oncogénicas c-bcl-2/metabolismo , Estribo/crecimiento & desarrollo , Animales , Proteínas Reguladoras de la Apoptosis/deficiencia , Proteínas Reguladoras de la Apoptosis/genética , Proteínas Reguladoras de la Apoptosis/metabolismo , Proteína 11 Similar a Bcl2 , Oído Medio/diagnóstico por imagen , Oído Medio/patología , Desarrollo Embrionario , Genotipo , Pérdida Auditiva Conductiva/patología , Pérdida Auditiva de Alta Frecuencia/metabolismo , Pérdida Auditiva de Alta Frecuencia/patología , Proteínas de la Membrana/deficiencia , Proteínas de la Membrana/genética , Proteínas de la Membrana/metabolismo , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Proteínas Proto-Oncogénicas/deficiencia , Proteínas Proto-Oncogénicas/genética , Proteínas Proto-Oncogénicas/metabolismo , Proteínas Proto-Oncogénicas c-bcl-2/deficiencia , Proteínas Proto-Oncogénicas c-bcl-2/genética , Radiografía , Estribo/metabolismo , Estribo/fisiopatología
5.
Phys Med Biol ; 56(16): 5265-74, 2011 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-21791734

RESUMEN

By applying a phase-retrieval step before carrying out standard filtered back-projection reconstructions in tomographic imaging, we were able to resolve structures with small differences in density within a densely absorbing sample. This phase-retrieval tomography is particularly suited for the three-dimensional segmentation of secondary osteons (roughly cylindrical structures) which are superimposed upon an existing cortical bone structure through the process of turnover known as remodelling. The resulting images make possible the analysis of the secondary osteon structure and the relationship between an osteon and the surrounding tissue. Our observations have revealed many different and complex 3D structures of osteons that could not be studied using previous methods. This work was carried out using a laboratory-based x-ray source, which makes obtaining these sorts of images readily accessible.


Asunto(s)
Osteón/citología , Imagenología Tridimensional/métodos , Tomografía/métodos , Fémur/citología , Humanos
6.
Opt Express ; 18(23): 23727-39, 2010 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-21164716

RESUMEN

Certain phase retrieval methods use knowledge about the free space propagation of a wave to phase a paraxial beam passing through one or more measurement planes. This approach has been widely applied and has been shown to quantitatively retrieve the refractive index profile of a sample. The quality of the phase retrieval will depend on a range of factors including sample feature size, propagation distance, measurement plane separation, wavelength and noise. Here we describe an optimisation study for two-plane phase retrieval using a laboratory-based X-ray source that considers all of these factors. We discuss our results in the context of a three-dimensional reconstruction of a sample refractive index profile.

7.
Ultramicroscopy ; 109(3): 280-6, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19162395

RESUMEN

We report an experimental investigation of the optical transfer functions for an X-ray microscope operated in defocus phase-contrast mode. The results are compared with a theoretical model of partially coherent image formation and are found to be in excellent agreement.

8.
Opt Express ; 16(24): 19950-6, 2008 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-19030082

RESUMEN

We describe a quantitative phase imaging process using an x-ray laboratory-based source with an extremely broad bandwidth spectrum. The thickness of a homogeneous object can be retrieved by using separately spectrally weighted values for the attenuation coefficient and the decrement of the real part of the refractive index. This method is valid for a wide range of object types, including objects with an absorption edge in the used energy range. The accessibility of conventional x-ray laboratory sources makes this method very useful for quantitative phase retrieval of homogeneous objects. We demonstrate the application of this method for quantitative phase retrieval imaging in tomographic measurements.

9.
Rev Sci Instrum ; 78(5): 053701, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17552819

RESUMEN

We examine a direct filtered back projection approach that is suitable for the reconstruction of weakly absorbing homogeneous phase objects. Like recent similar approaches this method needs only one intensity image in each projection without the requirement for an intermediate step of phase retrieval. We tested the method using simulation and experimental results. Simulation results show good quantitative reconstruction which includes the correct refractive index value and distribution of the sample. However, experimental result still indicates the presence of artifacts.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Tomografía Óptica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...