Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Anal Biochem ; 543: 108-115, 2018 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-29233680

RESUMEN

Rapid, cost-effective and sensitive detection of nucleic acids has the ability to improve upon current practices employed for pathogen detection in diagnosis of infectious disease and food testing. Furthermore, if assay complexity can be reduced, nucleic acid amplification tests could be deployed in resource-limited and home use scenarios. In this study, we developed a novel Fpg (Formamidopyrimidine DNA glycosylase) probe chemistry, which allows lateral flow detection of amplification in undiluted recombinase polymerase amplification (RPA) reactions. The prototype nucleic acid lateral flow chemistry was applied to a human genomic target (rs1207445), Campylobacter jejuni 16S rDNA and two genetic markers of the important food pathogen E. coli O157:H7. All four assays have an analytical sensitivity between 10 and 100 copies DNA per amplification. Furthermore, the assay is performed with fewer hands-on steps than using the current RPA Nfo lateral flow method as dilution of amplicon is not required for lateral flow analysis. Due to the simplicity of the workflow, we believe that the lateral flow chemistry for direct detection could be readily adapted to a cost-effective single-use consumable, ideal for use in non-laboratory settings.


Asunto(s)
ADN-Formamidopirimidina Glicosilasa/química , Sondas Moleculares/química , Técnicas de Amplificación de Ácido Nucleico , Reacción en Cadena de la Polimerasa , Recombinasas/química , ADN-Formamidopirimidina Glicosilasa/metabolismo , Escherichia coli O157/genética , Humanos , Sondas Moleculares/metabolismo , ARN Ribosómico 16S/genética , Recombinasas/metabolismo
2.
mBio ; 4(2)2013 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-23549916

RESUMEN

Early diagnosis and treatment of human immunodeficiency virus type 1 (HIV-1) infection in infants can greatly reduce mortality rates. However, current infant HIV-1 diagnostics cannot reliably be performed at the point of care, often delaying treatment and compromising its efficacy. Recombinase polymerase amplification (RPA) is a novel technology that is ideal for an HIV-1 diagnostic, as it amplifies target DNA in <20 min at a constant temperature, without the need for complex thermocycling equipment. Here we tested 63 HIV-1-specific primer and probe combinations and identified two RPA assays that target distinct regions of the HIV-1 genome (long terminal repeat [LTR] and pol) and can reliably detect 3 copies of proviral DNA by the use of fluorescence detection and lateral-flow strip detection. These pol and LTR primers amplified 98.6% and 93%, respectively, of the diverse HIV-1 variants tested. This is the first example of an isothermal assay that consistently detects all of the major HIV-1 global subtypes.


Asunto(s)
ADN Viral/análisis , Infecciones por VIH/diagnóstico , VIH-1/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Provirus/aislamiento & purificación , Cartilla de ADN/genética , ADN Viral/genética , ADN Polimerasa Dirigida por ADN/metabolismo , Diagnóstico Precoz , Infecciones por VIH/virología , VIH-1/genética , Humanos , Lactante , Sondas de Oligonucleótidos/genética , Provirus/genética , Recombinasas/metabolismo , Sensibilidad y Especificidad , Temperatura , Virología/métodos
3.
Lab Chip ; 10(7): 887-93, 2010 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-20300675

RESUMEN

For the first time we demonstrate a self-sufficient lab-on-a-foil system for the fully automated analysis of nucleic acids which is based on the recently available isothermal recombinase polymerase amplification (RPA). The system consists of a novel, foil-based centrifugal microfluidic cartridge including prestored liquid and dry reagents, and a commercially available centrifugal analyzer for incubation at 37 degrees C and real-time fluorescence detection. The system was characterized with an assay for the detection of the antibiotic resistance gene mecA of Staphylococcus aureus. The limit of detection was <10 copies and time-to-result was <20 min. Microfluidic unit operations comprise storage and release of liquid reagents, reconstitution of lyophilized reagents, aliquoting the sample into < or = 30 independent reaction cavities, and mixing of reagents with the DNA samples. The foil-based cartridge was produced by blow-molding and sealed with a self-adhesive tape. The demonstrated system excels existing PCR based lab-on-a-chip platforms in terms of energy efficiency and time-to-result. Applications are suggested in the field of mobile point-of-care analysis, B-detection, or in combination with continuous monitoring systems.


Asunto(s)
ADN/análisis , Microfluídica , Técnicas de Amplificación de Ácido Nucleico , Recombinasas , Microfluídica/instrumentación , Microfluídica/métodos , Staphylococcus aureus/genética , Temperatura
4.
PLoS Biol ; 4(7): e204, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16756388

RESUMEN

DNA amplification is essential to most nucleic acid testing strategies, but established techniques require sophisticated equipment or complex experimental procedures, and their uptake outside specialised laboratories has been limited. Our novel approach, recombinase polymerase amplification (RPA), couples isothermal recombinase-driven primer targeting of template material with strand-displacement DNA synthesis. It achieves exponential amplification with no need for pretreatment of sample DNA. Reactions are sensitive, specific, and rapid and operate at constant low temperature. We have also developed a probe-based detection system. Key aspects of the combined RPA amplification/detection process are illustrated by a test for the pathogen methicillin-resistant Staphylococcus aureus. The technology proves to be sensitive to fewer than ten copies of genomic DNA. Furthermore, products can be detected in a simple sandwich assay, thereby establishing an instrument-free DNA testing system. This unique combination of properties is a significant advance in the development of portable and widely accessible nucleic acid-based tests.


Asunto(s)
Técnicas de Amplificación de Ácido Nucleico/métodos , Bacillus subtilis/genética , Sondas de ADN , Genoma Humano , Humanos , Resistencia a la Meticilina/genética , Datos de Secuencia Molecular , Recombinasas/química , Sensibilidad y Especificidad , Staphylococcus aureus/genética , Staphylococcus aureus/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA