Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Injury ; 43(7): 980-8, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21741650

RESUMEN

Nonunions of the femoral shaft represent a treatment challenge for the orthopaedic surgeon and a serious socioeconomic problem for the patient. Inadequate fracture stability, insufficient blood supply, bone loss or presence of infection are the main reasons for the development of a nonunion. Careful classification and exclusion of infection are crucial for the choice of the proper treatment alternative. Nail dynamization, primary intramedullary nailing or nail exchange, plate osteosynthesis and external fixation along with bone grafting, usage of bone substitutes and electrical stimulation can stimulate osseous union. A review of the aetiology, classification and treatment should prove helpful managing this serious complication.


Asunto(s)
Fracturas del Fémur/diagnóstico por imagen , Fémur/irrigación sanguínea , Fijación Interna de Fracturas/métodos , Fracturas no Consolidadas/diagnóstico por imagen , Clavos Ortopédicos , Placas Óseas , Sustitutos de Huesos , Femenino , Fracturas del Fémur/fisiopatología , Fracturas del Fémur/cirugía , Fémur/cirugía , Fijación Interna de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Curación de Fractura , Fracturas no Consolidadas/fisiopatología , Fracturas no Consolidadas/cirugía , Humanos , Masculino , Radiografía , Resultado del Tratamiento
2.
Eur Spine J ; 21(2): 247-55, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21901328

RESUMEN

INTRODUCTION: With the advances and improvement of computer-assisted surgery devices, computer-guided pedicle screws insertion has been applied to the lumbar, thoracic and cervical spine. The purpose of the present study was to perform a systematic review of all available prospective evidence regarding pedicle screw insertion techniques in the thoracic and lumbar human spine. MATERIALS AND METHODS: We considered all prospective in vivo clinical studies in the English literature that assessed the results of different pedicle screw placement techniques (free-hand technique, fluoroscopy guided, computed tomography (CT)-based navigation, fluoro-based navigation). MEDLINE, OVID, and Springer databases were used for the literature search covering the period from January 1950 until May 2010. RESULTS: 26 prospective clinical studies were eventually included in the analysis. These studies included in total 1,105 patients in which 6,617 screws were inserted. In the studies using free-hand technique, the percentage of the screws fully contained in the pedicle ranged from 69 to 94%, with the aid of fluoroscopy from 28 to 85%, using CT navigation from 89 to 100% and using fluoroscopy-based navigation from 81 to 92%. The screws positioned with free-hand technique tended to perforate the cortex medially, whereas the screws placed with CT navigation guidance seemed to perforate more often laterally. CONCLUSIONS: In conclusion, navigation does indeed exhibit higher accuracy and increased safety in pedicle screw placement than free-hand technique and use of fluoroscopy.


Asunto(s)
Tornillos Óseos , Vértebras Lumbares/cirugía , Procedimientos Ortopédicos/métodos , Cirugía Asistida por Computador , Vértebras Torácicas/cirugía , Fluoroscopía , Humanos , Estudios Prospectivos
3.
Spine J ; 11(11): 1042-8, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22122837

RESUMEN

BACKGROUND CONTEXT: Spinal procedures have a potential of intraoperative contamination. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) have been used to diagnose postoperative infections after spinal surgery. However, it has not been demonstrated if there is an association between surgical site contamination and clinical manifestation of postoperative infection based on inflammatory markers and patients' clinical course. PURPOSE: The purpose of this prospective study was to evaluate the association between surgical site contamination and the development of a postoperative infection in simple and complex surgical procedures. C-reactive protein and ESR levels were observed. The correlation between their values, surgical time, type of surgical procedures, and contaminated surgical sites was investigated. STUDY DESIGN: Prospective clinical study. PATIENT SAMPLE: The study consisted of 40 patients divided into two groups. Group A included 20 patients (mean age, 46.2 years; 12 women and 8 men) who underwent an open discectomy for a lumbar herniated disc. Group B consisted of 20 patients (mean age, 67.9 years; 11 women and 9 men) who underwent a decompression and instrumented fusion for lumbar spinal stenosis. They were followed up for an average of 26.7 months (range, 11-40 months). OUTCOME MEASURES: Samples were obtained for cultures in standard time intervals during surgery. The types of bacteria cultured were evaluated, and CRP and ESR levels were measured. METHODS: Simple lumbar discectomy (Group A, 20 patients) and instrumented lumbar decompression for degenerative lumbar stenosis (Group B, 20 patients) were performed in a prospective consecutive series of patients. All patients were operated by the same surgeon in the same operating room. Surgical site preparation in each patient was done by a standard manner. Samples were obtained for cultures in standard time intervals during surgery. C-reactive protein and ESR levels were measured preoperatively on the 3rd, 7th, and 21st postoperative days, and the clinical course of each patient was recorded. RESULTS: From 40 patients, three patients in Group A and five patients in Group B, a total of eight patients (20%) had positive cultures for bacteria. There was no statistical significance between contamination and duration of surgery in both groups. None of the patients with positive intraoperative cultures developed any clinical signs of superficial or deep postoperative spinal infection, and no additional antibiotic treatment was administered. Three patients with negative cultures developed a postoperative infection. There were no differences in CRP and ESR values between patients with contamination and noncontamination in both groups. C-reactive protein and ESR levels were significantly elevated in complex procedures (Group B) than in simple procedures (Group A). Statistical analysis of CRP and ESR values in both groups and types of bacteria cultured intraoperatively are presented. CONCLUSIONS: The results of this study demonstrate that intraoperative contamination can occur during simple and complex spinal procedures. In the absence of postoperative signs of infection in patients with intraoperative contamination, there is no need of continuing antibiotic treatment. Postoperative kinetics of CRP and ESR showed to be the same in patients with and without intraoperative contamination. Higher levels of inflammatory markers were noted in complex spinal procedures where instrumentation was applied.


Asunto(s)
Infecciones Bacterianas/epidemiología , Descompresión Quirúrgica/efectos adversos , Discectomía/efectos adversos , Fusión Vertebral/efectos adversos , Infección de la Herida Quirúrgica/epidemiología , Adulto , Anciano , Infecciones Bacterianas/sangre , Infecciones Bacterianas/etiología , Sedimentación Sanguínea , Proteína C-Reactiva/análisis , Femenino , Humanos , Desplazamiento del Disco Intervertebral/cirugía , Vértebras Lumbares , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estenosis Espinal/cirugía , Infección de la Herida Quirúrgica/sangre
4.
Cases J ; 2: 6149, 2009 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-19829768

RESUMEN

INTRODUCTION: The diagnosis of cervical spine injuries remains a significant problem in many blunt trauma patients. Correct and early diagnosis of these injuries is imperative as delayed or missed diagnoses result in increased morbidity and mortality. CASE PRESENTATION: A 57-year-old Caucasian woman presented with a misdiagnosed bilateral C5-C6 dislocation one month after a fall and head injury, without clearance of the cervical spine in her previous visits to two physicians and having already started physiotherapy sessions, despite the presence of pain in the clinical examination. Dislocation was treated with open reduction and spinal fusion with posterior instrumentation 4 weeks post-trauma. CONCLUSIONS: Every physician should be highly suspicious of cervical spine injury in blunt trauma patients with positive clinical examination and include radiologic studies in his screening modality. Physiotherapy sessions should under no circumstances be started in the presence of underlying spine injury.

5.
Microsurgery ; 26(4): 253-61, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16634083

RESUMEN

The purpose of this study was to assess the maximum rapid intraoperative elongation of the rat sciatic nerve with the use of tissue expander, and its possible functional recovery. One hundred and eight rats were divided into five groups, and their right sciatic nerves were expanded with a 10-cc, 12-cc, 14-cc, 16-cc, and 18-cc expander, respectively, for 1 h. The functional recovery of the nerve was assessed at intervals up to 3 months, using the sciatic function index (SFI), neurophysiological indices, and histology. The maximum intraoperative elongation was observed in group IV (16-cc volume of tissue expander), at about 23.83%. SFI decreased between the first and seventh postoperative days, but gradually recovered, reaching preoperative values in all groups according to the formulas of De Medinaceli et al. (Exp. Neurol. 77:634-643, 1982) and Bain et al. (Plast. Reconstr. Surg. 83:129-136, 1989). Latency and motor conduction velocity demonstrated deterioration after expansion, which peaked after surgery. Recovery was gradually completed by the end of the experiment. The histological findings indicated minor aberrations immediately after expansion and maximal demyelination with axonal disruption on day 15. The reparative process started by day 30 and continued until day 90, when almost no histological changes were observed. In conclusion, intraoperative nerve expansion successfully elongates the rat sciatic nerve up to 23.83%. But it causes functional and morphological abnormalities, which are of moderate to severe degree, are of short duration, and are reversible. Intraoperative nerve expansion might be a valuable solution in the treatment of short nerve gaps, but its clinical application still needs to be evaluated.


Asunto(s)
Nervio Ciático/cirugía , Expansión de Tejido/métodos , Animales , Periodo Intraoperatorio , Masculino , Ratas , Ratas Wistar , Nervio Ciático/anatomía & histología , Nervio Ciático/fisiología , Dispositivos de Expansión Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...