Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Neuroradiol ; 34(2): 411-420, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38289378

RESUMEN

PURPOSE: Various MRI-based techniques were tested for the differentiation of neurodegenerative Parkinson syndromes (NPS); the value of these techniques in direct comparison and combination is uncertain. We thus compared the diagnostic performance of macrostructural, single compartmental, and multicompartmental MRI in the differentiation of NPS. METHODS: We retrospectively included patients with NPS, including 136 Parkinson's disease (PD), 41 multiple system atrophy (MSA) and 32 progressive supranuclear palsy (PSP) and 27 healthy controls (HC). Macrostructural tissue probability values (TPV) were obtained by CAT12. The microstructure was assessed using a mesoscopic approach by diffusion tensor imaging (DTI), neurite orientation dispersion and density imaging (NODDI), and diffusion microstructure imaging (DMI). After an atlas-based read-out, a linear support vector machine (SVM) was trained on a training set (n = 196) and validated in an independent test cohort (n = 40). The diagnostic performance of the SVM was compared for different inputs individually and in combination. RESULTS: Regarding the inputs separately, we observed the best diagnostic performance for DMI. Overall, the combination of DMI and TPV performed best and correctly classified 88% of the patients. The corresponding area under the receiver operating characteristic curve was 0.87 for HC, 0.97 for PD, 1.0 for MSA, and 0.99 for PSP. CONCLUSION: We were able to demonstrate that (1) MRI parameters that approximate the microstructure provided substantial added value over conventional macrostructural imaging, (2) multicompartmental biophysically motivated models performed better than the single compartmental DTI and (3) combining macrostructural and microstructural information classified NPS and HC with satisfactory performance, thus suggesting a complementary value of both approaches.


Asunto(s)
Imagen de Difusión Tensora , Enfermedad de Parkinson , Parálisis Supranuclear Progresiva , Humanos , Masculino , Femenino , Anciano , Estudios Retrospectivos , Imagen de Difusión Tensora/métodos , Persona de Mediana Edad , Diagnóstico Diferencial , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/patología , Parálisis Supranuclear Progresiva/diagnóstico por imagen , Parálisis Supranuclear Progresiva/patología , Máquina de Vectores de Soporte , Atrofia de Múltiples Sistemas/diagnóstico por imagen , Atrofia de Múltiples Sistemas/patología , Sensibilidad y Especificidad , Imagen por Resonancia Magnética/métodos
2.
Clin Neuroradiol ; 32(1): 225-230, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34665277

RESUMEN

BACKGROUND AND PURPOSE: To develop a fully automatic algorithm for the magnetic resonance imaging (MRI) identification of patients with spontaneous intracranial hypotension (SIH). MATERIAL AND METHODS: A support vector machine (SVM) was trained with structured reports of 140 patients with clinically suspected SIH. Venous sinuses and basal cisterns were segmented on contrast-enhanced T1-weighted MPRAGE (Magnetization Prepared-Rapid Gradient Echo) sequences using a convolutional neural network (CNN). For the segmented sinuses and cisterns, 56 radiomic features were extracted, which served as input data for the SVM. The algorithm was validated with an independent cohort of 34 patients with proven cerebrospinal fluid (CSF) leaks and 27 patients who had MPRAGE scans for unrelated reasons. RESULTS: The venous sinuses and the suprasellar cistern had the best discriminative power to separate SIH and non-SIH patients. On a combined score with 2 points, mean SVM score was 1.41 (±0.60) for the SIH and 0.30 (±0.53) for the non-SIH patients (p < 0.001). Area under the curve (AUC) was 0.91. CONCLUSION: A fully automatic algorithm analyzing a single MRI sequence separates SIH and non-SIH patients with a high diagnostic accuracy. It may help to consider the need of invasive diagnostics and transfer to a SIH center.


Asunto(s)
Hipotensión Intracraneal , Máquina de Vectores de Soporte , Encéfalo/diagnóstico por imagen , Pérdida de Líquido Cefalorraquídeo , Humanos , Hipotensión Intracraneal/diagnóstico por imagen , Imagen por Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...