1.
Cardiovasc Intervent Radiol ; 44(2): 318-324, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33179161

RESUMEN

PURPOSE: The first-pass effect during mechanical thrombectomy improves clinical outcomes regardless of first-line treatment approach, but current success rates for complete clot capture with one attempt are still less than 40%. We hypothesize that the ThrombX retriever (ThrombX Medical Inc.) can better engage challenging clot models during retrieval throughout tortuous vasculature in comparison with a standard stent retriever without increasing distal emboli. MATERIALS AND METHODS: Thrombectomy testing with the new retriever as compared to the Solitaire stent retriever was simulated in a vascular replica with hard and soft clot analogs to create a challenging occlusive burden. Parameters included analysis of distal emboli generated per clot type, along with the degree of recanalization (complete, partial or none) by retrieval device verified by angiography. RESULTS: The ThrombX device exhibited significantly higher rates of first-pass efficacy (90%) during hard clot retrieval in comparison with the control device (20%) (p < 0.009), while use of both techniques during soft clot retrieval resulted in equivalent recanalization. The soft clot model generated higher numbers of large emboli (>200 µm) across both device groups (p = 0.0147), and no significant differences in numbers of distal emboli were noted between the ThrombX and Solitaire techniques. CONCLUSIONS: Irrespective of clot composition, use of the ThrombX retriever demonstrated high rates of complete recanalization at first pass in comparison with a state-of-the-art stent retriever and proved to be superior in the hard clot model. Preliminary data suggest that risk of distal embolization associated with the ThrombX system is comparable to that of the control device.


Asunto(s)
Embolia Intracraneal/cirugía , Trombectomía/instrumentación , Trombectomía/métodos , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Embolia Intracraneal/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Resultado del Tratamiento
2.
J Neurointerv Surg ; 11(9): 931-936, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30718384

RESUMEN

BACKGROUND: Evidence is mounting that first-pass complete recanalization during mechanical thrombectomy is associated with better clinical outcomes in patients presenting with an emergent large vessel occlusion. We hypothesize that aspiration achieving complete clot ingestion results in higher first-pass successful recanalization with quantitative reduction in distal emboli. METHODS: A patient-specific cerebrovascular replica was connected to a flow loop. Occlusion of the middle cerebral artery was achieved with clot analogs. Independent variables were the diameter of the aspiration catheter (0.054-0.088in) and aspiration pattern (static versus cyclical). Outcome measures were the first-pass rates of complete clot ingestion, the extent of recanalization, and the particle-size distribution of distal emboli. RESULTS: All aspiration catheters were successfully navigated to the occlusion. Complete clot ingestion during aspiration thrombectomy resulted in first-pass complete recanalization in every experiment, only achieved in 21% of experiments with partial ingestion (P<0.0001). Aspiration through the large bore 0.088in device resulted in the highest rates of complete clot ingestion (90%). Cyclical aspiration (18-29 inHg, 0.5 Hz) significantly increased the rate of complete clot ingestion (OR21 [1.6, 266]; P=0.04). In all experiments, complete clot ingestion resulted in fewer and smaller distal emboli. CONCLUSIONS: Complete clot ingestion results in fewer distal emboli and the highest rates of first-pass complete recanalization. The rate of complete ingestion during aspiration thrombectomy is a function of both the inner diameter of the aspiration catheter and use of cyclical aspiration.


Asunto(s)
Catéteres , Trombectomía/instrumentación , Trombectomía/métodos , Trombosis/cirugía , Animales , Bovinos , Trastornos Cerebrovasculares/cirugía , Embolización Terapéutica/métodos , Humanos , Arteria Cerebral Media/cirugía , Procedimientos de Cirugía Plástica/instrumentación , Procedimientos de Cirugía Plástica/métodos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/cirugía , Resultado del Tratamiento