Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Environ Sci Technol ; 55(21): 14968-14978, 2021 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-34644501

RESUMEN

We report a new, autonomous Lab-on-Chip (LOC) microfluidic pH sensor with a 6000 m depth capability, ten times the depth capability of the state of the art autonomous spectrophotometric sensor. The pH is determined spectrophotometrically using purified meta-Cresol Purple indicator dye offering high precision (<0.001 pH unit measurement reproducibility), high frequency (every 8 min) measurements on the total proton scale from the surface to the deep ocean (to 600 bar). The sensor requires low power (3 W during continuous operation or ∼1300 J per measurement) and low reagent volume (∼3 µL per measurement) and generates small waste volume (∼2 mL per measurement) which can be retained during deployments. The performance of the LOC pH sensor was demonstrated on fixed and moving platforms over varying environmental salinity, temperature, and pressure conditions. Measurement accuracy was +0.003 ± 0.022 pH units (n = 47) by comparison with validation seawater sample measurements in coastal waters. The combined standard uncertainty of the sensor in situ pHT measurements was estimated to be ≤0.009 pH units at pH 8.5, ≤ 0.010 pH units at pH 8.0, and ≤0.014 pH units at pH 7.5. Integrated on autonomous platforms, this novel sensor opens new frontiers for pH observations, especially within the largest and most understudied ecosystem on the planet, the deep ocean.


Asunto(s)
Ecosistema , Agua de Mar , Concentración de Iones de Hidrógeno , Reproducibilidad de los Resultados , Espectrofotometría
2.
Eur J Neurosci ; 53(5): 1394-1411, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33131114

RESUMEN

Ageing is associated in many organisms with a reduction in motor movements. We have previously shown that the rate of feeding movements of the pond snail, Lymnaea, decreased with age but the underlying cause is not fully understood. Here, we show that dopamine in the cerebro-buccal complex is an important signalling molecule regulating feeding frequency in Lymnaea and that ageing is associated with a decrease in CNS dopamine. A proteomic screen of young and old CNSs highlighted a group of proteins that regulate stress responses. One of the proteins identified was 14-3-3, which can enhance the synthesis of dopamine. We show that the Lymnaea 14-3-3 family exists as three distinct isoforms. The expression of the 29 kDa isoform (14-3-3Lym3) in the cerebro-buccal complex decreased with age and correlated with feeding rate. Using a 14-3-3 antagonist (R18) we were able to reduce the synthesis of L-DOPA and dopamine in ex vivo cerebro-buccal complexes. Together these data suggest that an age-related reduction in 14-3-3 can decrease CNS dopamine leading to a consequential reduction in feeding rate.


Asunto(s)
Dopamina , Lymnaea , Animales , Sistema Nervioso Central , Conducta Alimentaria , Proteómica
3.
J Microbiol Methods ; 141: 63-66, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28803789

RESUMEN

An electrochemical anti-fouling method, based upon the generation of chlorine from seawater, was applied to a proprietary design of Lab on a Chip conductivity, temperature and dissolved oxygen sensor. The method was evaluated using PCR after a six-week field trial in which it significantly reduced the burden of bacterial biofouling.


Asunto(s)
Incrustaciones Biológicas/prevención & control , Técnicas Electroquímicas/métodos , Dispositivos Laboratorio en un Chip , Agua de Mar/química , Bacterias/efectos de los fármacos , Bacterias/crecimiento & desarrollo , Fenómenos Fisiológicos Bacterianos/efectos de los fármacos , Cloro/metabolismo , Ácido Hipocloroso/farmacología , Océanos y Mares , Oxígeno , Reacción en Cadena de la Polimerasa , Agua de Mar/análisis , Temperatura
4.
Electrophoresis ; 32(18): 2402-9, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21922490

RESUMEN

The electrokinetic transport behavior of λ-DNA (48 kbp) in 20 nm-high fused-silica nanoslits in the presence of short-chain PVP is investigated. Mobility and video data show a number of phenomena that are typical of DNA transport through gels or polymer solutions, thus indicative of rigid migration obstacles in the DNA pathway. Calculations show that a several nanometer thin layer of wall-adsorbed PVP ('nano-gel') can provide such a rigid obstacle matrix to the DNA. Such ultrathin wall-adsorbed polymer layers represent a new type of matrix for electrokinetic DNA separation.


Asunto(s)
ADN Viral/química , Electroforesis/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Adsorción , Bacteriófago lambda/química , Bacteriófago lambda/genética , ADN Viral/análisis , Electroforesis/métodos , Técnicas Analíticas Microfluídicas/métodos , Polímeros , Dióxido de Silicio/química , Estadísticas no Paramétricas
5.
Lab Chip ; 11(17): 3001-5, 2011 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-21776485

RESUMEN

The rapid prototyping of a reversible and one step moulded compartmentalised neuron glass/PDMS device with a thin wall barrier directly adjacent to the reservoirs is presented. A simple moulding technique to produce these devices results in a barrier of 560 µm where the 3 µm deep by 8 µm wide channels can be reversibly fabricated in either the glass base or PDMS compartmentalised mould depending on the type of application required. Using glass substrates with commercially laser engraved microchannels, both the PDMS planar and PDMS channelled device can be easily fabricated in a standard laboratory. The compartmentalised device has several advantages including good experimental accessibility and versatility with a variety of end user applications.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Neuronas/citología , Animales , Técnicas de Cultivo de Célula/métodos , Células Cultivadas , Dimetilpolisiloxanos/química , Vidrio/química , Ratones
6.
Phys Chem Chem Phys ; 12(34): 10065-72, 2010 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-20625576

RESUMEN

Microelectrode amperometry is uniquely suited for characterising the dynamics of neurotransmitter release, as it offers unparalleled spatial and temporal resolution. We have used carbon fibre microelectrodes to study release of the monoamine neurotransmitter serotonin (5-HT) and the gaseous transmitter nitric oxide (NO) in intact central nervous system of the water snail, Lymnaea stagnalis. Analysis of spontaneous vesicular release of 5-HT and depolarisation-induced release of NO reveals significant differences with ageing that may be associated with changes in protein structure and function.


Asunto(s)
Senescencia Celular , Electroquímica/métodos , Neuronas/citología , Animales , Encéfalo/citología , Microelectrodos , Neuroglía/metabolismo , Neuronas/metabolismo , Óxido Nítrico/metabolismo , Serotonina/metabolismo
7.
Lab Chip ; 10(2): 211-9, 2010 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-20066249

RESUMEN

A hybrid microfluidic device that uses hydrodynamic forces to separate human plasma from blood cells has been designed and fabricated and the advantageous effects of temperature and flow rates are investigated in this paper. The blood separating device includes an inlet which is reduced by approximately 20 times to a small constrictor channel, which then opens out to a larger output channel with a small lateral channel for the collection of plasma. When tested the device separated plasma from whole blood using a wide range of flow rates, between 50 microl min(-1) and 200 microl min(-1), at the higher flow rates injected by hand and at temperatures ranging from 23 degrees C to 50 degrees C, the latter resulting in an increase in the cell-free layer of up to 250%. It was also tested continuously using between 5% and 40% erythrocytes in plasma and whole blood without blocking the channels or hemolysis of the cells. The mean percentage of plasma collected after separation was 3.47% from a sample of 1 ml. The percentage of cells removed from the plasma varied depending on the flow rate used, but at 37 degrees C ranged between 95.4 +/- 1% and 97.05 +/- 05% at 100 microl min(-1) and 200 microl min(-1), respectively. The change in temperature also had an effect on the number of cells removed from the plasma which was between 93.5 +/- 0.65% and 97.01 +/- 0.3% at 26.9 degrees C and 37 degrees C, respectively, using a flow rate of 100 microl min(-1). Due to its ability to operate in a wide range of conditions, it is envisaged that this device can be used in in vitro 'lab on a chip' applications, as well as a hand-held point of care (POC) device.


Asunto(s)
Eliminación de Componentes Sanguíneos/instrumentación , Recolección de Muestras de Sangre/instrumentación , Calefacción/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Plasma/química , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Temperatura
8.
J Neurochem ; 106(4): 1699-709, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18565208

RESUMEN

This study utilised the pond snail, Lymnaea to examine the contribution that alterations in serotonergic signalling make to age-related changes in feeding. Age-related decreases in 5-HIAA levels in feeding ganglia were positively correlated with a decrease in the number of sucrose-evoked bites and negatively correlated with an increase in inter-bite interval, implicating alterations in serotonergic signalling in the aged phenotype. Analysis of the serotonergic cerebral giant cell (CGC) input to the protraction motor neurone (B1) demonstrated that fluoxetine (10-100 nM) increased the amplitude/duration of the evoked EPSP in both young and middle aged but not in old neurones, suggesting an age-related attenuation of the serotonin transporter. 5-HT evoked a concentration-dependent increase in the amplitude/duration of B1 EPSP, which was greater in old neurones compared to both young and middle aged. Conversely, the 5-HT-evoked depolarisation and conditional bursting of the swallow motor neurone (B4) were attenuated in old neurones, functions critical for a full feeding rhythm. The CGCs' ability to excite B1 was blocked by cinanserin but not by methysergide. Conversely, the CGC to B4 connection was completely blocked by methysergide and only partially by cinanserin suggesting that age-related changes may be receptor-specific. In summary, synapse-specific attenuation of the CGC-B4 connection and enhancement of the CGC-B1 connection would slow the swallow phase and maintain protraction, consistent with behavioural observations.


Asunto(s)
Envejecimiento/fisiología , Conducta Alimentaria/fisiología , Lymnaea/fisiología , Serotonina/fisiología , Transducción de Señal/fisiología , Sinapsis/fisiología , Animales , Potenciales Postsinápticos Excitadores/fisiología , Lymnaea/crecimiento & desarrollo
9.
Biosens Bioelectron ; 24(2): 290-6, 2008 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-18511254

RESUMEN

This article presents the fabrication and characterisation of a high-speed detection micro-Coulter counter with two-dimensional (2D) adjustable aperture and differential impedance detection. The developed device has been fabricated from biocompatible and transparent materials (polymer and glass) and uses the principle of hydrodynamic focusing in two dimensions. The use of a conductive solution for the sample flux and non-conductive solutions for the focalising fluxes provides an adjustable sample flow where particles are aligned and the resistive response concentrated, consequently enhancing the sensitivity and versatility of the device. High-speed counting of 20 microm polystyrene particles and 5 microm yeast cells with a rate of up to 1,000 particles/s has been demonstrated. Two-dimensional focusing conditions have been used in devices with physical cross-sectional areas of 180 microm x 65 microm and 100 microm x 43 microm, respectively, in which particles resulted undetectable in the absence of focusing. The 2D-focusing conditions have provided, in addition, increased detection sensitivity by a factor of 1.6 as compared to 1D-focusing conditions.


Asunto(s)
Recuento de Células/instrumentación , Electrónica/instrumentación , Citometría de Flujo/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Anal Bioanal Chem ; 390(5): 1379-87, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18185922

RESUMEN

We have fabricated a six individual addressable gold working electrode microarray. The device is wirebonded to an eight-pin DIL package that can be easily interconnected to an external multi-channel potentiostat. A polyion complex film coating on the electrode surface provides a suitable coating for the growth of cells. The responses of oxygen and nitric oxide were assessed on uncoated and coated devices using electroanalytical methods. The film coating reduced the diffusion current by approximately 20% in both cases. No changes in the electrochemical mechanism were observed. Simultaneous recordings were obtained for 2 h in the presence of the cells, thus the device is stable for the duration of the bioanalytical measurements. Measurements were conducted to study the simultaneous changes in oxygen and nitric oxide levels in cultured fibroblast cells in the presence of growth hormones that cause cell proliferation. Increases in oxygen consumption of the cells were coupled with increases in nitric oxide levels when in the presence of the growth hormones. Use of a biological detergent to cause an oxidative burst resulted in a large increase in the current for potentials set to detect nitric oxide and oxygen.


Asunto(s)
Óxido Nítrico/análisis , Oxígeno/análisis , Materiales Biocompatibles/química , Células Cultivadas , Fibroblastos , Humanos , Microelectrodos , Compuestos de Rutenio/química
11.
Anal Chem ; 78(22): 7643-8, 2006 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-17105154

RESUMEN

Multiple film-coated nitric oxide sensors have been fabricated using Nafion and electropolymerized polyeugenol or o-phenylenediamine on 30-microm carbon fiber disk electrodes. This is a rare study that utilizes disk electrodes rather than the widely used protruding tip microelectrodes in order to measure from a biological environment. These electrodes have been used to evaluate the differences in nitric oxide release between two different identified neurons in the pond snail, Lymnaea stagnalis. These results show the first direct measurements of nitric oxide release from individual neurons. The electrodes are very sensitive to nitric oxide with a detection limit of 2.8 nM and a sensitivity of 9.46 nA microM-1. The sensor was very selective against a variety of neurochemical interferences such as ascorbic acid, uric acid, and catecholamines and secondary oxidation products such as nitrite. Nitric oxide release was measured from the cell bodies of two neurons, the cerebral giant cell (CGC) and the B2 buccal motor neuron, in the intact but isolated CNS. A high-Ca2+/high-K+ stimulus was capable of evoking reproducible release. For a given stimulus, the B2 neuron released more nitric oxide than the CGC neuron; however, both cells were equally suppressed by the NOS inhibitor l-NAME.


Asunto(s)
Técnicas Biosensibles , Lymnaea/fisiología , Neuronas/metabolismo , Óxido Nítrico/análisis , Animales , Ácido Ascórbico/farmacología , Química Encefálica/efectos de los fármacos , Química Encefálica/fisiología , Calcio/farmacología , Catecolaminas/farmacología , Electrodos , Inhibidores Enzimáticos/farmacología , Células Gigantes/citología , Células Gigantes/fisiología , Neuronas/efectos de los fármacos , Óxido Nítrico/metabolismo , Óxido Nítrico Sintasa/antagonistas & inhibidores , Nitritos/análisis , Nitritos/metabolismo , Potasio/farmacología , Sensibilidad y Especificidad , Ácido Úrico/farmacología
12.
Anal Chem ; 78(19): 6990-8, 2006 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-17007525

RESUMEN

Although voltammetry has proved an important tool for unraveling the dynamics of specific neurotransmitter molecules during the past decade, it has been very difficult to monitor more than one neurotransmitter simultaneously. In this work, we present a voltammetric methodology that allows discrimination between dopamine and serotonin, two important neurotransmitter molecules with very similar electrochemical properties, in the presence of high concentrations of ascorbate. We combined the application of a novel large-amplitude/high-frequency voltage excitation with signal processing techniques valid for the analysis of nonstationary and nonlinear phenomena. This allows us to minimize the contribution from capacitance and preserve the faradaic features of the voltammetric response providing us with excellent voltammetric detail. Using appropriate voltage excitation parameters and defining specific regions in the voltage space, so-called voltage windows, we can measure the concentrations of dopamine and serotonin separately or independently in mixed solutions even in the presence of high concentrations of ascorbate. Because of the enhanced voltammetric detail of this new technique, it is also possible to explore effects attributed to interfacial phenomena such as adsorption/desorption and electrode fouling.


Asunto(s)
Ácido Ascórbico/química , Dopamina/aislamiento & purificación , Serotonina/aislamiento & purificación , Electroquímica
13.
Artículo en Inglés | MEDLINE | ID: mdl-15734169

RESUMEN

Using the CNS of Lymnaea stagnalis a method is described for the rapid analysis of neurotransmitters and their metabolites using high performance liquid chromatography coupled with electrochemical detection. Tissue samples were homogenised in ice-cold 0.1 M perchloric acid and centrifuged. Using a C(18) microbore column the mobile phase was maintained at a flow rate of 100 microl/min and consisted of sodium citrate buffer (pH 3.2)-acetonitrile (82.5:17.5, v/v) with 2 mM decane-sulfonic acid sodium salt. The potential was set at +750 mV versus Ag|AgCl reference electrode at a sensitivity of 50 nA full scale deflection. The detection limit for serotonin was 11.86 ng ml(-1) for a 5 microl injection. Preparation of tissue samples in mobile phase reduced the response to dopamine and serotonin compared with perchloric acid. In addition it was found that the storage of tissue samples at -20 degrees C caused losses of dopamine and serotonin. As a result of optimising the sample preparation and mobile phase the total time of analysis was substantially reduced resulting in a sample preparation and assay time of 15-20 min.


Asunto(s)
Monoaminas Biogénicas/análisis , Catecolaminas/análisis , Cromatografía Líquida de Alta Presión/métodos , Lymnaea/química , Serotonina/análisis , Animales , Sistema Nervioso Central/química , Estabilidad de Medicamentos , Electroquímica/instrumentación , Neuronas/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Anal Chem ; 74(7): 1503-8, 2002 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-12033237

RESUMEN

Surface-enhanced resonance Raman scattering (SERRS) of a model derivative of TNT was detected using a microflow cell designed within the framework of the lab-on-a-chip concept, using only the analyte and readily available reagents. The SERRS substrate, silver colloid, was prepared in situ, on-chip, by borohydride reduction of silver nitrate. The silver colloid was imaged within the chip using a white light microscope in either transmission or, due to the high reflectivity of the colloid, reflection mode. A fine stream of colloid approximately 30 microm in width was formed in a 250-microm-wide channel at the point where the colloid preparation reagents met. The chip was designed to produce a concentrated stream of colloid within a laminar regime, such that particles did not readily disperse into the fluid. One result of this was to reduce the effective volume of analysis. Attempts to deliberately disrupt this stream with microstructured pillars, fabricated in the fluidic channels, were unsuccessful. The chip was also designed to have the appropriate dimensions for detection using a modern Raman microscope system, which collects scattering from a very small volume. A dye derived from TNT was used as a model analyte. Quantitative behavior was obtained over 4 orders of magnitude with a detection limit of 10 fmol. This performance is between 1 and 2 orders of magnitude better than that achieved using a macroflow SERRS cell. The technique has the added advantage that both reagent consumption and effluent production are greatly reduced, leading to reduced operating costs and a decreased environmental impact

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...