Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 258
Filtrar
1.
Sci Rep ; 14(1): 18536, 2024 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-39122752

RESUMEN

In this systematic review and meta-analysis, we aim to evaluate the efficacy and safety of catheter ablation as the first-line treatment of ventricular tachycardia (VT) in patients with structural heart disease (SHD) and preserved left ventricular ejection fraction (LVEF). Patients with SHD are particularly susceptible to VT, a condition that increases the risk of sudden cardiac death (SCD). Implantable cardioverter-defibrillators (ICDs) can terminate VT and prevent SCD but do not prevent VT recurrence. The efficacy and safety of CA as a first-line treatment in SHD patients with preserved LVEF remain unclear. We searched PubMed/Medline, EMBASE, Web of Science, and Cochrane CENTRAL for studies reporting the outcomes of CA therapy in patients with VT and preserved LVEF, published up to January 19, 2023. The primary outcome was the incidence of SCD following catheter ablation as the first-line treatment of VT in patients with SHD and preserved LVEF. Secondary outcomes included all-cause mortality, VT recurrence, procedural complications, CA success rate, and ICD implantation after catheter ablation. We included seven studies in the meta-analysis, encompassing a total of 920 patients. The pooled success rate of catheter ablation was 84.6% (95% CI 67.2-93.6). Complications occurred in 6.4% (95% CI 4.0-9.9) of patients, and 13.9% (95% CI 10.1-18.8) required ICD implantation after ablation. VT recurrence was observed in 23.2% (95% CI 14.8-34.6) of patients, while the rate of sudden cardiac death (SCD) was 3.1% (95% CI 1.7-5.6). The overall prevalence of all-cause mortality in this population was 5% (95% CI 1.8-13). CA appears promising as a first-line VT treatment in patients with SHD and preserved LVEF, especially for monomorphic hemodynamically tolerated VT. However, due to the lack of direct comparisons with ICDs and anti-arrhythmic drugs, further research is needed to confirm these findings.


Asunto(s)
Ablación por Catéter , Volumen Sistólico , Taquicardia Ventricular , Humanos , Ablación por Catéter/métodos , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
2.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38646922

RESUMEN

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Esófago , Traumatismos del Nervio Vago , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Masculino , Femenino , Esófago/lesiones , Esófago/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios Prospectivos , Persona de Mediana Edad , Traumatismos del Nervio Vago/etiología , Traumatismos del Nervio Vago/epidemiología , Incidencia , Anciano , Aprendizaje Automático , Factores de Riesgo , Alemania/epidemiología , Quemaduras/epidemiología , Quemaduras/etiología , Factores de Tiempo , Resultado del Tratamiento , Venas Pulmonares/cirugía , Nervio Vago
3.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38582974

RESUMEN

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Criocirugía , Taquicardia Ventricular , Anciano , Humanos , Persona de Mediana Edad , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Cicatriz/complicaciones , Criocirugía/efectos adversos , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Temperatura , Resultado del Tratamiento
4.
Clin Cardiol ; 47(3): e24250, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38450791

RESUMEN

BACKGROUND: Catheter ablation has become one of the main treatment strategies in patients with premature ventricular complexes (PVC). The successful mapping and ablation can be performed with an ablation catheter without additional diagnostic catheters. HYPOTHESIS: We hypothesize that using a single catheter for PVC ablation may decrease complications, procedure time, and fluoroscopy exposure while maintaining comparable success rates. METHODS: Sixty-nine consecutive patients with PVC were treated with a single catheter approach compared to a historical cohort, in which a conventional setup was used. Propensity score matching was conducted with a 1:1 ratio. Outcome parameters included acute procedural success with elimination of all premature ventricular contractions after catheter ablation, procedural data as well as complication rates. RESULTS: Patients treated with a single catheter approach had shorter total procedure (60 minutes [IQR: 47,5-69,0 minutes] vs. 90 minutes [IQR 60-120 minutes]; p = 0.001) and fluoroscopy times (218 seconds [IQR: 110,5-446 seconds] vs. 310 seconds [IQR 190-640 seconds]; p = 0.012), which consecutively leads to a reduction of radiation exposure signified by a lower dose area product (155 cGycm² [IQR 74.4-334.5 cGycm²] vs. 368.4 cGycm² [IQR: 126-905.4 cGycm²]; p value 0.009). Acute procedural success rates were comparable in both groups (54 [84.3%] in the single catheter approach group and 58 [90.6%] in the conventional group; p: 0.287). CONCLUSION: A single catheter approach for the treatment of PVC is associated with a reduction of procedure- and fluoroscopy time, as well as a lesser radiation exposure, while maintaining equivalent acute success and complication rates compared with a conventionally used catheter setup.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Humanos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía , Ablación por Catéter/efectos adversos , Catéteres , Fluoroscopía , Puntaje de Propensión
5.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38127308

RESUMEN

AIMS: Recurrences of ventricular tachycardia (VT) after initial catheter ablation is a significant clinical problem. In this study, we report the efficacy and risks of repeat VT ablation in patients with structural heart disease (SHD) in a tertiary single centre over a 7-year period. METHODS AND RESULTS: Two hundred ten consecutive patients referred for repeat VT ablation after previous ablation in our institution were included in the analysis (53% ischaemic cardiomyopathy, 91% males, median age 65 years, mean left ventricular ejection fraction 35%). After performing repeat ablation, the clinical VTs were acutely eliminated in 82% of the patients, but 46% of the cohort presented with VT recurrence during the 25-month follow-up. Repeat ablation led to a 73% reduction of shock burden in the first year and 61% reduction until the end of follow-up. Similarly, VT burden was reduced 55% in the first year and 36% until the end of the study. Fifty-two patients (25%) reached the combined endpoint of ventricular assist device implantation, heart transplantation, or death. Advanced New York Heart Association functional class, anteroseptal substrate, and periprocedural complication after repeat ablation were associated with worse prognosis independently of the type of cardiomyopathy. CONCLUSION: While complete freedom from VT after repeat ablation in SHD was difficult to achieve, ablation led to a significant reduction in VT and shock burden. Besides advanced heart failure characteristics, anteroseptal substrate and periprocedural complications predicted a worse outcome.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Cardiopatías , Taquicardia Ventricular , Masculino , Humanos , Anciano , Femenino , Volumen Sistólico , Función Ventricular Izquierda , Cardiopatías/etiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Cardiomiopatías/complicaciones , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
6.
J Cardiovasc Electrophysiol ; 34(11): 2342-2359, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37767743

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) with biventricular pacing (BiV-CRT) is ineffective in approximately one-third of patients. CRT with Conduction system pacing (CSP-CRT) may achieve greater synchronization. We aimed to assess the effectiveness of CRT with His pacing (His-CRT) or left bundle branch pacing (LBB-CRT) in lieu of biventricular CRT. METHODS AND RESULTS: The PubMed, Embase, Web of Science, Scopus, and the Cochrane Library were systematically searched until August 19, 2023, for original studies including patients with reduced left ventricular ejection fraction (LVEF) who received His- or LBB-CRT, that reported either CSP-CRT success, LVEF, QRS duration (QRSd), or New York Heart Association (NYHA) classification. Effect measures were compared with frequentist network meta-analysis. Thirty-seven publications, including 20 comparative studies, were included. Success rates were 73.5% (95% CI: 61.2-83.0) for His-CRT and 91.5% (95% CI: 88.0-94.1) for LBB-CRT. Compared to BiV-CRT, greater improvements were observed for LVEF (mean difference [MD] for His-CRT +3.4%; 95% CI [1.0; 5.7], and LBB-CRT: +4.4%; [2.5; 6.2]), LV end-systolic volume (His-CRT:17.2mL [29.7; 4.8]; LBB-CRT:15.3mL [28.3; 2.2]), QRSd (His-CRT: -17.1ms [-25.0; -9.2]; LBB-CRT: -17.4ms [-23.2; -11.6]), and NYHA (Standardized MD [SMD]: His-CRT:0.4 [0.8; 0.1]; LBB-CRT:0.4 [-0.7; -0.2]). Pacing thresholds at baseline and follow-up were significantly lower with LBB-CRT versus both His-CRT and BiV-CRT. CSP-CRT was associated with reduced mortality (R = 0.75 [0.61-0.91]) and hospitalizations risk (RR = 0.63 [0.42-0.96]). CONCLUSION: This study found that CSP-CRT is associated with greater improvements in QRSd, echocardiographic, and clinical response. LBB-CRT was associated with lower pacing thresholds. Future randomized trials are needed to determine CSP-CRT efficacy.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Metaanálisis en Red , Resultado del Tratamiento , Trastorno del Sistema de Conducción Cardíaco , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Fascículo Atrioventricular , Electrocardiografía/métodos
7.
J Cardiovasc Electrophysiol ; 34(2): 403-411, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36434796

RESUMEN

BACKGROUND AND OBJECTIVE: Cardiac tamponade during ablation procedures is a life-threatening complication. While the incidence and management of tamponade in atrial fibrillation ablation have been extensively described, the data on tamponade during ventricular ablations are very limited. The purpose of this study is to shed light on the incidence, typical perforation sites, and optimal management as observed through real-life data in a tertiary referral center for ventricular ablation. METHODS AND RESULTS: Consecutive patients with structural heart disease undergoing ventricular tachycardia ablation from 2008-2020 were analyzed. Of the 1078 patients undergoing 1287 ventricular ablation procedures, 20 procedures (1.5%) were complicated by cardiac tamponade. In all but one patient, the tamponade was treated with emergent pericardial drainage, while nine patients eventually underwent surgical repair. The perforation occurred during transseptal or subxiphoid puncture in six patients, during ventricle mapping in two patients, and during ablation in five patients (predominantly basal left ventricle). Steam pop as definite perforation cause could only be established in two patients. Regardless of the management of the complication, all patients survived to discharge. CONCLUSION: Cardiac tamponade during ventricular ablation occurred in 1.5% of the procedures. In nine patients cardiac repair was necessary. Perforation was mostly associated with subxiphoid puncture or ablation of the basal left ventricle.


Asunto(s)
Fibrilación Atrial , Taponamiento Cardíaco , Ablación por Catéter , Humanos , Taponamiento Cardíaco/epidemiología , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/terapia , Incidencia , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ventrículos Cardíacos , Punciones/efectos adversos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
8.
Europace ; 25(2): 450-459, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36413611

RESUMEN

AIMS: Atrial fibrillation (AF) is a global health problem with high morbidity and mortality. Catheter ablation (CA) can reduce AF burden and symptoms, but AF recurrence (AFr) remains an issue. Simple AFr predictors like P-wave duration (PWD) could help improve AF therapy. This updated meta-analysis reviews the increasing evidence for the association of AFr with PWD and offers practical implications. METHODS AND RESULTS: Publication databases were systematically searched and cohort studies reporting PWD and/or morphology at baseline and AFr after CA were included. Advanced interatrial block (aIAB) was defined as PWD ≥ 120 ms and biphasic morphology in inferior leads. Random-effects analysis was performed using the Review Manager 5.3 and R programs after study selection, quality assessment, and data extraction, to report odds ratio (OR) and confidence intervals. : Among 4175 patients in 22 studies, 1138 (27%) experienced AFr. Patients with AFr had longer PWD with a mean pooled difference of 7.8 ms (19 studies, P < 0.001). Pooled OR was 2.04 (1.16-3.58) for PWD > 120 ms (13 studies, P = 0.01), 2.42 (1.12-5.21) for PWD > 140 ms (2 studies, P = 0.02), 3.97 (1.79-8.85) for aIAB (5 studies, P < 0.001), and 10.89 (4.53-26.15) for PWD > 150 ms (4 studies, P < 0.001). There was significant heterogeneity but no publication bias detected. CONCLUSION: P-wave duration is an independent predictor for AF recurrence after left atrium ablation. The AFr risk is increasing exponentially with PWD prolongation. This could facilitate risk stratification by identifying high-risk patients (aIAB, PWD > 150 ms) and adjusting follow up or interventions.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrocardiografía/métodos , Atrios Cardíacos , Estudios de Cohortes , Bloqueo Interauricular , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
9.
Pharmacol Rep ; 75(1): 189-198, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36334247

RESUMEN

BACKGROUND: It has been suggested that the anti-hyperglycemic effect of metformin could be associated with its impact on long non-coding RNA (lncRNA) expression levels. Accordingly, in the current study, we evaluated the effect of metformin on the expression of H19, MEG3, MALAT1, and GAS5 in in vitro and in vivo situations. METHODS: The effect of hyperglycemia and metformin treatment on the lncRNAs expression level was evaluated in HepG2 cells. A total of 179 age- and sex-matched subjects, including 88 newly diagnosed patients with type 2 diabetes (T2D) and 91 healthy volunteers, were included in the case-control phase of the study. Moreover, 40 newly diagnosed patients participated in the study's open-labeled non-controlled clinical trial phase. The expression levels of lncRNA in HepG2 cells and whole blood samples were determined using QRT-PCR. RESULTS: In vitro results showed that hyperglycemia induced H19 and MALAT1 and decreased GAS5 expression levels. Moreover, metformin decreased H19 and increased GAS5 expression in high glucose-treated cells. Case-control study findings revealed that the circulating levels of H19, MALAT1, and MEG3 were significantly elevated in T2D patients compared to the control subjects. Finally, results showed that the level of circulating H19 levels decreased while GAS5 increased in T2D patients after taking metformin for 2 months. CONCLUSION: The results of the current study provided evidence that metformin could exert its effect in the treatment of T2D by altering the expression levels of H19 and GAS5.


Asunto(s)
Diabetes Mellitus Tipo 2 , Metformina , ARN Largo no Codificante , Humanos , Metformina/farmacología , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/genética , ARN Largo no Codificante/genética , ARN Largo no Codificante/metabolismo , Estudios de Casos y Controles
10.
J Am Coll Cardiol ; 80(11): 1045-1056, 2022 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-36075673

RESUMEN

BACKGROUND: Recurrent ventricular tachycardia (VT) due to dilated cardiomyopathy (DCM) is difficult to treat, and long-term outcome data are limited. OBJECTIVES: The aim of this study was to identify predictors of mortality or heart transplantation (HTx) and VT recurrence. METHODS: Consecutive patients with DCM accepted for radiofrequency catheter ablation (RFCA) of VT at 9 centers were prospectively enrolled and followed. RESULTS: Of 281 consecutive patients (mean age 60 ± 13 years, 85% men, mean left ventricular ejection fraction [LVEF] 36% ± 12%), 35% had VT storm, 20% had incessant VT, and amiodarone was unsuccessful in 68%. During follow-up of 21 months (IQR: 6-30 months), 67 patients (24%) died or underwent HTx, and 138 (49%) had VT recurrence (45 within 30 days, defined as early); the 4-year rate of VT recurrence or mortality or HTx was 70%. Independent predictors of mortality or HTx were early VT recurrence (HR: 2.92; 95% CI: 1.37-6.21; P < 0.01), amiodarone at discharge (HR: 3.23; 95% CI: 1.43-7.33; P < 0.01), renal dysfunction (HR: 1.92; 95% CI: 1.01-3.64; P = 0.046), and LVEF (HR: 1.36; 95% CI: 1.0-1.84; P = 0.052). LVEF ≤32% identified patients at risk for mortality or HTx (area under the curve: 0.75). Mortality or HTx per 100 person-years was 40.4 events after early, compared with 14.2 events after later VT recurrence and 8.5 events with no VT recurrence after RFCA (P < 0.01 for both). Patients with early recurrence and LVEFs ≤32% had a 1-year rate of mortality or HTx of 55%. VT recurrence was predicted by prior implantable cardioverter-defibrillator shocks, basal anteroseptal VT origin, and procedural failure but not LVEF. CONCLUSIONS: Patients with DCM needing RFCA for VT are a high-risk group. Following RFCA, approximately one-half remain free of VT recurrence. Early VT recurrence with LVEF ≤32% identifies those at very high risk for mortality or HTx, and screening for mechanical support or HTx should be considered. Late VT recurrence after RFCA does not predict worse outcome.


Asunto(s)
Amiodarona , Cardiomiopatía Dilatada , Ablación por Catéter , Taquicardia Ventricular , Anciano , Amiodarona/uso terapéutico , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Función Ventricular Izquierda
11.
J Interv Cardiol ; 2022: 6829725, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35935125

RESUMEN

Background: Catheter ablation of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) is an effective tool to prevent VT recurrences. Chronic total occlusion (CTO) represents a clinically relevant entity in ICM patients and is an independent predictor of ventricular arrhythmia and mortality. The effects of CTO on the outcome of VT ablation are not well-studied. Objective: This analysis aimed to identify the impact of CTO, revascularized, or not revascularized, on the outcome of VT ablation. Methods and Results: Of 385 consecutive subjects with ICM-VT who underwent catheter VT ablation for monomorphic VT at Heart Center Leipzig between 2008 and 2017, 108 patients without CTO and 191 patients with CTO were included in the analysis. Within a median follow-up time of 557 days (IQR 149, 1095), VT recurred in 77 (40%) patients in the CTO and 40 (37.0%) in the non-CTO cohort (p = 0.62). In a multivariable model, a 10% stepwise change in LVEF as well as ICD on admission was associated with VT recurrence (HRadj 1.82, 95% CI 1.04-3.18 and HRadj 1.35, 95% CI 1.23-1.61, respectively). Of the CTO cohort before ablation, 45% had received revascularization, which was independently associated with a higher risk for VT recurrence (HR 2.12, 95% CI 1.35-3.34) as compared to nonrevascularized CTO. Conclusion: In ICM patients with and without CTO, VT ablation was associated with equal effectiveness with regard to VT recurrence. However, in revascularized CTO patients, the risk of recurrence of VT after ablation was significantly increased.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Cardiomiopatías/complicaciones , Cardiomiopatías/cirugía , Ablación por Catéter/métodos , Humanos , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Recurrencia , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
12.
Europace ; 24(11): 1800-1808, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-35851396

RESUMEN

AIM: Cardiac sympathetic denervation (CSD) has been introduced as a bailout therapy in patients with structural heart disease and refractory ventricular arrhythmias (VAs), but available data are scarce. Purpose of this study was to estimate immediate results, complications, and mid-term outcomes of CSD following recurrent VA after catheter ablation. METHODS AND RESULTS: Adult patients who underwent CSD in the Heart Center Leipzig from March 2017 to February 2021 were retrospectively analysed. Follow-up (FU) was executed via implantable cardioverter defibrillator (ICD) interrogation, telephone interviews, and reviewing medical records. Twenty-one patients (age 63.7 ± 14.4 years, all men, 71.4% non-ischaemic cardiomyopathy, left ventricular ejection fraction 31.6 ± 12.6%) received CSD via video-assisted thoracoscopic surgery (90.5% bilateral, 9.5% left-sided only). Indication for CSD was monomorphic ventricular tachycardia in 76.2% and ventricular fibrillation in 23.8 with 71.4% of patients presenting with electrical storm before index hospitalization. Procedure-related major complications occurred in 9.5% of patients. In-hospital adverse events not related to surgery were common (28.6%) and two patients died during the index hospital stay. During FU (mean duration 9.1 ± 6.5 months), five more patients died. Of the remaining patients, 38.5 and 76.9% were free from any VA or ICD shocks, respectively. CONCLUSIONS: The CSD showed additional moderate efficacy to suppress VAs, when performed as a bailout therapy after previously unsuccessful catheter ablation. At 9 months, it was associated with freedom of ICD shocks in two-thirds of patients. In a population with many comorbidities, the rate of CSD-related complications was acceptable, although there was an overall high risk of procedure unrelated adverse events and death.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Adulto , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Simpatectomía/efectos adversos , Simpatectomía/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/cirugía
13.
Europace ; 24(10): 1617-1626, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35726877

RESUMEN

AIMS: Data on safety and efficacy of a non-fasting strategy in minimal invasive cardiac procedures are lacking. We assessed a non-fasting strategy compared with a fasting strategy regarding patient's well-being and safety in elective cardiac implantable electronic device (CIED) procedures. METHODS AND RESULTS: In this randomized, single-blinded clinical trial, 201 patients (non-fasting = 100, fasting = 101) with a mean age of 72.0 ± 11.6 years (66.7% male) were assigned to a non-fasting strategy (solids/fluids allowed up to 1 h) or a fasting strategy (at least 6 h no solids and 2 h no fluids) before the procedure and analysed on an intention-to-treat basis. The co-primary outcomes were patients' well-being scores (based on numeric rating scale, 0-10) and incidence of intra-procedural food-related adverse events, including vomiting, perioperative pulmonary aspiration, and emergency intubation. Renal, haematological, and metabolic blood parameters and 30-day follow-up data were gathered. The summed pre-procedural patients' well-being score was significantly lower in the non-fasting group [non-fasting: 13.1 ± 9.6 vs. fasting: 16.5 ± 11.4, 95% confidence interval (CI) of mean difference (MD) -6.35 to -0.46, P = 0.029], which was mainly driven by significantly lower scores for hunger and tiredness in the non-fasting group (non-fasting vs. fasting; hunger: 0.9 ± 1.9 vs. 3.1 ± 3.2, 95% CI of MD -2.86 to -1.42, P < 0.001; tiredness: 1.6 ± 2.3 vs. 2.6 ± 2.7, 95% CI of MD -1.68 to -0.29, P = 0.023). No intra-procedural food-related adverse events were observed. Relevant blood parameters and 30-day follow-up did not show significant differences. CONCLUSION: These results showed that a non-fasting strategy is beneficial to a fasting one regarding patient's well-being and comparable in terms of safety for CIED procedures (NCT04389697).


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Electrónica , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad
14.
Herzschrittmacherther Elektrophysiol ; 33(2): 217-223, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35277790

RESUMEN

OBJECTIVES: This study analyzes the incidence, characteristics, and ECG morphology of ventricular tachycardia (VT) in post-infarction patients undergoing epicardial VT ablation. BACKGROUND: Ablation of recurrent VTs in patients with ischemic cardiomyopathy is typically performed endocardially. In rare cases, epicardial access is required to achieve non-inducibility. METHODS AND RESULTS: The study evaluated the baseline characteristics, procedural data, and ECG morphology of clinical VT in patients undergoing epicardial VT ablation. From the initial 491 patients with coronary heart disease (CHD) and recurrent VTs undergoing ablation at the Heart Center of Leipzig, Germany, between 2012 and 2020, only 39 patients required an additional epicardial access. In 17 patients, the VTs were associated with infarction scar, while the remaining patients had concomitant CHD without infarction-associated scar and were excluded from the analysis. A propensity match study was performed at a 1:2 ratio for these 17 patients, with 34 patients of the initial cohort as a control group to evaluate the differences in baseline characteristics, procedural data, and ECG morphology of the VTs. The specific VT morphology of negative concordance and superior axis in patients with inferior scar as well as the history of VT ablation were independent predictors of the need for epicardial access. CONCLUSIONS: In addition to previous endocardial ablation, VT ECG morphology with negative concordance and superior axis in post-infarction patients with inferior scar predicted the need for epicardial VT ablation.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Ablación por Catéter/métodos , Cicatriz/complicaciones , Cicatriz/diagnóstico , Cicatriz/cirugía , Electrocardiografía/métodos , Humanos , Infarto/complicaciones , Infarto/cirugía , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
15.
Sensors (Basel) ; 22(3)2022 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-35161960

RESUMEN

The Apple Watch is capable of recording single-lead electrocardiograms (ECGs). To incorporate such devices in routine medical care, the reliability of such devices to obtain precordial leads needs to be validated. The purpose of this study was to assess the feasibility and reliability of a smartwatch (SW) to obtain precordial leads compared to standard ECGs. We included 100 participants (62 male, aged 62.8 ± 13.1 years) with sinus rhythm and recorded a standard 12-lead ECG and the precordial leads with the Apple Watch. The ECGs were quantitively compared. A total of 98 patients were able to record precordial leads without assistance. A strong correlation was observed between the amplitude of the standard and SW-ECGs' waves, in terms of P waves, QRS-complexes, and T waves (all p-values < 0.01). A significant correlation was observed between the two methods regarding the duration of the ECG waves (all p-values < 0.01). Assessment of polarity showed a significant and a strong concordance between the ECGs' waves in all six leads (91-100%, all p-values < 0.001). In conclusion, 98% of patients were able to record precordial leads using a SW without assistance. The SW is feasible and reliable for obtaining valid precordial-lead ECG recordings as a validated alternative to a standard ECG.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía , Anciano , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
16.
JACC Case Rep ; 3(16): 1756-1759, 2021 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-34825204

RESUMEN

A 25-year-old male patient with highly symptomatic, monomorphic, premature ventricular contractions presented for repeat ablation after failed endocardial ablation. Three weeks after excessive endocardial and epicardial ablation on the left ventricular summit, the patient was admitted again with tamponade following a pseudoaneurysm on the ablation site. (Level of Difficulty: Advanced.).

17.
Europace ; 23(12): 1980-1988, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34405874

RESUMEN

AIMS: Epicardial ablation has risen to an essential part of the treatment of ventricular tachycardias (VTs). In this study, we report the efficacy, risks, and current trends of epicardial ablation in structural heart disease as reported in a tertiary single centre over a 12-year period. METHODS AND RESULTS: Two hundred and thirty-six patients referred for VT ablation underwent a successful epicardial access and were included in the analysis (89% non-ischaemic cardiomyopathy, 90% males, mean age 60 years, mean left ventricular ejection fraction 38.4%). After performing epicardial ablation the clinical VTs were eliminated in 87% of the patients and 71% of the cohort achieved freedom from VT during 22-month follow-up. Twelve patients (5%) suffered major procedure-related complications. Until the end of follow-up 47 (20%) patients died, 9 (4%) underwent a left ventricular assist device implantation and 10 (4%) patients received a heart transplantation. Antiarrhythmic drugs at baseline and during follow-up were independent predictors of VT recurrence. Atrial fibrillation, renal dysfunction, worse New York Heart Association class, and antiarrhythmic drugs at follow-up were associated with worse survival in our cohort. CONCLUSION: In this large tertiary single-centre experience, percutaneous epicardial access was feasible in the large majority of the cohort with acceptably low complications rates. A combined endo-/epicardial approach resulted in 87% acute and 71% long-term success. Further studies are needed to clarify the role of routine combined endo-/epicardial ablation in these complex cardiomyopathies.


Asunto(s)
Ablación por Catéter , Cardiopatías , Taquicardia Ventricular , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Cardiopatías/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda
18.
J Cardiovasc Electrophysiol ; 32(10): 2675-2683, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34411387

RESUMEN

INTRODUCTION: This study sought to examine gender differences in patients with structural heart disease (SHD) referred for ablation of ventricular tachycardia (VT). BACKGROUND: Female patients are often underrepresented in large studies. Significant differences in the clinical presentation, treatment, and prognosis of female patients have been described in previous studies. METHODS AND RESULTS: We investigated 88 female patients with SHD undergoing VT ablation (mean age 59 years, 56% nonischemic cardiomyopathy, mean left ventricular ejection fraction 35%, 82% in electrical storm). A case-control study with 88 male patients was performed and the results regarding clinical and procedural characteristics, acute and long-term results of the two groups were compared. The female patients had more arrhythmogenic substrate, as they more commonly presented with electrical storm (p = .016) and had a higher number of inducible VT morphologies during the procedure (p = .018). Moreover, the female patients were less likely to have an optimized heart failure medical treatment at baseline (p = .030) and required more time from the first manifestation of the VT to ablation referral (p = .034). Although fewer epicardial ablations were performed in female patients (p = .019), the two groups showed similar results regarding VT noninducibility as ablation endpoint (p = .844), major procedure-related complications (p = .719) and freedom from VT during follow-up (p = .268). Moreover, the overall mortality in the two groups was similar (p = .176). Advanced NYHA class was associated with worse transplant and assist-device-free survival in the female group. CONCLUSION: Female patients presenting for VT ablation had more arrhythmogenic substrate and were less likely to have an optimized heart failure medical treatment. Nevertheless, the procedural acute and long-term outcomes between the two genders were similar.


Asunto(s)
Ablación por Catéter , Cardiopatías , Taquicardia Ventricular , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Factores Sexuales , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda
20.
Herzschrittmacherther Elektrophysiol ; 32(3): 353-358, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34269843

RESUMEN

INTRODUCTION: Ablation of ventricular tachycardias (VTs) in patients with structural heart disease (SHD) has been associated with advanced heart failure and poor survival. METHODS AND RESULTS: This matched case-control study sought to assess the difference in survival after left ventricular assist device (LVAD) implantation and/or heart transplantation (HTX) in SHD patients undergoing VT ablation. From the initial cohort of 309 SHD patients undergoing VT ablation (187 ischemic cardiomyopathy, mean age 64 ± 12 years, ejection fraction of 34 ± 13%), 15 patients received an LVAD and nine patients HTX after VT ablation during a follow-up period of 44 ± 33 months. Long-term survival after LVAD did not differ from the matched control group (p = 0.761), although the cause of lethal events was different. All post-HTX patients survived during follow-up. CONCLUSION: In this matched case-control study on patients with SHD undergoing VT ablation, patients that received LVAD implantation had similar survival compared to the control group after 4­year follow-up, while the patients with HTX had a significantly better outcome.


Asunto(s)
Ablación por Catéter , Cardiopatías , Trasplante de Corazón , Taquicardia Ventricular , Anciano , Estudios de Casos y Controles , Humanos , Persona de Mediana Edad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA