Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Intern Med ; 62(23): 3519-3523, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37779072

RESUMEN

The prognosis of patients with post-coronavirus disease 2019 (COVID-19) interstitial lung disease remains unclear. We herein report an autopsy case in which serial progression after the onset of post-COVID-19 interstitial lung disease resulted in an acute exacerbation, leading to a fatal outcome. Autopsy findings included hyaline membrane formation/interstitial inflammatory cell infiltration, suggestive of acute lesions, and severe regional fibrosis, indicating a preexisting chronic condition. In the present case, we histopathologically confirmed the acute exacerbation of post-COVID-19 interstitial lung disease.


Asunto(s)
COVID-19 , Enfermedades Pulmonares Intersticiales , Humanos , COVID-19/complicaciones , Autopsia , Enfermedades Pulmonares Intersticiales/complicaciones , Enfermedades Pulmonares Intersticiales/patología
2.
Sci Rep ; 13(1): 14724, 2023 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-37679360

RESUMEN

Bronchoscopy with radial-probe endobronchial ultrasound, a guide sheath, and electromagnetic navigation can improve the diagnostic yield of peripheral lung nodules. However, the suitability of specimens for genetic analysis remains unsatisfactory. We hypothesized that a transbronchial biopsy performed after closely approaching the bronchoscope tip to the lesion might provide more suitable specimens for genetic analysis. We enrolled 155 patients with peripheral pulmonary lesions who underwent bronchoscopy with a thin or ultrathin bronchoscope. Bronchoscopy was performed using virtual bronchoscopic navigation and radial-probe endobronchial ultrasound with a guide sheath. The bronchoscope tip was placed closer to the lesion during bronchoscopy to collect larger specimens with higher malignant cell content. The patients who underwent a close-to-lesion biopsy had higher rates of overall diagnostic yield, histopathological diagnostic yield, and specimen quality for genetic testing than those who did not. The significant determinants of the specimen's suitability were the close-to-lesion approach, within-the-lesion image, the use of standard 1.9-mm-forceps, and the number of cancer-cell-positive specimens. The significant predictors of the specimen's suitability for genetic analysis were close-to-lesion biopsy and the number of malignant cell-positive tissue samples. This study demonstrates that the close-to-lesion transbronchial biopsy significantly improves the suitability of bronchoscopic specimens for genetic analysis.


Asunto(s)
Broncoscopía , Pruebas Genéticas , Humanos , Masculino , Biopsia , Endosonografía , Prepucio
3.
Int J Emerg Med ; 16(1): 23, 2023 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-37024788

RESUMEN

BACKGROUND: This study aimed to understand whether the one-time chair stand test (CS-1) is useful for predicting the severity of coronavirus disease (COVID-19) in 101 patients admitted to the hospital with acute respiratory failure. METHODS: This single-centered, prospective observational cohort study enrolled 101 critically ill adult patients hospitalized with COVID-19 who underwent the CS-1 as a dynamic evaluation tool in clinical practice between late April 2020 and October 2021. Data on demographic characteristics, symptoms, laboratory values, computed tomography findings, and clinical course after admission were collected. Furthermore, the data was compared, and the association between the intubation and non-intubation groups was determined. We also calculated the cutoff point, area under the curve (AUC), and 95% confidence interval (CI) of the change in oxygen saturation (ΔSpO2) during the CS-1. RESULTS: Thirty-three out of 101 patients (33%) were intubated during hospitalization. There was no significant difference in the resting SpO2 (93.3% versus 95.2%, P = 0.22), but there was a significant difference in ΔSpO2 during the CS-1 between the intubation and non-intubation groups (10.8% versus 5.5%, P < 0.01). In addition, there was a significant correlation between hospitalization and ΔSpO2 during the CS-1 (ρ = 0.60, P < 0.01). The generated cutoff point was calculated as 9.5% (AUC = 0.94, 95% CI = 0.88-1.00). CONCLUSION: For COVID-19 patients with acute respiratory failure, the CS-1 performed on admission was useful for predicting the severity of COVID-19. Furthermore, the CS-1 can be utilized as a remote and simple evaluation parameter. Thus, it could have potential clinical applications in the future.

4.
Intern Med ; 60(4): 595-599, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-32999226

RESUMEN

A 68-year-old man visited a physician with a chief complaint of difficulty breathing. Right pleural effusion was noted, and he was referred to our department for a close examination and treatment. Thoracoscopy was performed under local anesthesia, and pleural dissemination of lung adenocarcinoma was noted, so a chest drain was placed. Since poor right lung inflation persisted and whole right lung torsion was observed on computed tomography, thoracoscopy-assisted thoracotomic reduction of lung torsion was performed. In this patient, the right middle lobe and anterior chest wall were adhered, suggesting that whole right lung torsion occurred when atelectasis was formed due to pleural effusion.


Asunto(s)
Adenocarcinoma del Pulmón , Neoplasias Pulmonares , Derrame Pleural , Adenocarcinoma del Pulmón/complicaciones , Adenocarcinoma del Pulmón/diagnóstico por imagen , Anciano , Humanos , Pulmón , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Derrame Pleural/diagnóstico por imagen , Derrame Pleural/etiología , Anomalía Torsional/complicaciones , Anomalía Torsional/diagnóstico por imagen , Anomalía Torsional/cirugía
5.
Intern Med ; 60(4): 605-609, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-32999228

RESUMEN

The patient was a 75-year-old man who developed polyopia and exophthalmos. Chest computed tomography (CT) revealed a mass in the left upper lobe. A CT-guided biopsy suggested lung adenocarcinoma. He was treated by neoadjuvant chemotherapy followed by left upper lobectomy. He was diagnosed with stage IIB pleomorphic carcinoma postoperatively. Preoperative head magnetic resonance imaging revealed exophthalmos and bilateral swelling of the extraocular muscles. The thyroid function of the patient was within the normal range, and he tested negative for autoantibodies. As his symptoms and swelling of the extraocular muscles improved postoperatively, he was diagnosed with paraneoplastic syndrome.


Asunto(s)
Carcinoma , Exoftalmia , Neoplasias Pulmonares , Síndromes Paraneoplásicos , Anciano , Diplopía , Exoftalmia/diagnóstico , Exoftalmia/etiología , Humanos , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/diagnóstico , Masculino , Síndromes Paraneoplásicos/diagnóstico , Síndromes Paraneoplásicos/etiología , Tomografía Computarizada por Rayos X
6.
J Bronchology Interv Pulmonol ; 27(4): 253-258, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32282445

RESUMEN

BACKGROUND: The Japan Society for Respiratory Endoscopy performed a nationwide survey to evaluate the current status and complications of bronchoscopy. Data on deaths due to bronchoscopy, complications after bronchoscopy, and particularly, complications of forceps biopsy were surveyed. METHODS: The survey form was mailed to 532 facilities accredited by the society. The numbers of procedures, complications, and deaths were investigated. RESULTS: The response rate was 79.1% (421 facilities). Deaths attributable to diagnostic bronchoscopy occurred in 11 (0.011%) of 98,497 cases.In regards to forceps biopsy, the guide sheath method was applied in 23,916 cases and the conventional method in 31,419 cases was done with conventional method. Complications of forceps biopsy developed in 1019 cases in total, with an incidence rate of 1.84%. The most frequent complication was pneumothorax (0.70%), followed by pneumonia/pleurisy (0.46%) and hemorrhage (0.45%). The incidence of hemorrhagic complication was significantly lower in the guide sheath group than in the non-guide sheath group (0.29% vs. 0.58%; P<0.001). The overall incidence of complications (1.63% vs. 2.00%; P=0.002) and the mortality rate (0% vs. 0.02%; P=0.04) were significantly lower in the guide sheath group. CONCLUSION: The incidence of hemorrhagic complications in forceps biopsy of peripheral pulmonary lesions was lower when the guide sheath method was applied. It is necessary to increase the awareness for safety control in diagnostic bronchoscopy for new procedures.


Asunto(s)
Broncoscopía/efectos adversos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Hemorragia/epidemiología , Biopsia Guiada por Imagen/efectos adversos , Neoplasias Pulmonares/patología , Instrumentos Quirúrgicos/efectos adversos , Broncoscopía/métodos , Broncoscopía/mortalidad , Broncoscopía/estadística & datos numéricos , Endoscopía , Hemorragia/etiología , Hemorragia/mortalidad , Humanos , Incidencia , Japón , Mortalidad/tendencias , Pleuresia/epidemiología , Pleuresia/etiología , Neumonía/epidemiología , Neumonía/etiología , Neumotórax/epidemiología , Neumotórax/etiología , Estudios Retrospectivos , Sociedades Médicas/organización & administración , Encuestas y Cuestionarios/estadística & datos numéricos
7.
Front Med (Lausanne) ; 7: 588048, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33385003

RESUMEN

There are cases of peripheral lung nodules that are difficult to approach despite using ancillary diagnostic devices during multimodal bronchoscopy. The use of ultrathin bronchoscopes has shown superiority over standard thin bronchoscopes. We retrospectively evaluated whether substitution of the thin-bronchoscope by the ultrathin device during multimodal bronchoscopy improves lesion ultrasound visualization and diagnostic yield in patients with difficult-to-approach pulmonary lesions. The study comprised 44 out of 338 patients that underwent multimodal bronchoscopy at Matsusaka Municipal Hospital. The thin-bronchoscope with an external diameter of 4 mm was substituted by the ultrathin-bronchoscope with an external diameter of 3 mm when the radial endobronchial ultrasound showed that the probe position was not within the target lesion. The median diameter of the pulmonary tumors was 17.5 mm (range: 6.0-5.2.0 mm). The endobronchial ultrasound showed the probe's position adjacent to the lesion in 12 cases and no visible lesion in 32 cases using a thin-bronchoscope. However, the endobronchial ultrasound views changed from adjacent to the lesion to within the lesion in nine cases, from no visible lesion to within the lesion in 17 cases, and from no visible lesion to adjacent to the lesion in nine cases after bronchoscope substitution. After substitution, the diagnostic yield was 80.8% in cases with the radial probe within the target lesion, 72.7% in cases with the probe adjacent to the target lesion, and 0% in cases with no visible lesion. The overall diagnostic yield was 65.9% after bronchoscope substitution. The substitution of the thin bronchoscope by the ultrathin device on a need basis improves the position of the radial endobronchial ultrasound probe and diagnostic yield of pulmonary lesions during multimodal diagnostic bronchoscopy.

8.
Respir Res ; 20(1): 207, 2019 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-31511032

RESUMEN

BACKGROUND: The diagnostic yield of peripheral pulmonary lesions has significantly increased with the use of radial endobronchial ultrasound with guide sheath within the lesion. Here, we retrospectively evaluated factors leading to misdiagnosis of pulmonary malignant tumors using endobronchial ultrasound with the guide sheath within the lesion. METHODS: We assessed the final histopathological diagnosis of biopsy samples taken from 130 patients with lung malignant tumors that underwent endobronchial ultrasound with guide sheath within the lesion. RESULTS: Among 130 patients, 8 (6%) showed no definite malignant findings in biopsy samples but the presence of malignant cells (primary lung cancer 7, diffuse large B cell lymphoma 1) was subsequently confirmed by histopathological study of specimens taken by computed tomography-guided needle biopsy or surgery. Of the eight cases with diagnostic failure, the size of the biopsy sample was insufficient in five due to technical difficulties during the diagnostic procedure, and the diagnosis of malignant tumor was difficult in five cases because of extensive scarring tissue or central necrosis. CONCLUSIONS: The results of this study showed that technical difficulties and/or pathological heterogeneity of the tumor might lead to failure to diagnose lung malignant tumor in cases using endobronchial ultrasound with guide sheath within the lesion.


Asunto(s)
Broncoscopía/métodos , Endosonografía/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Diagnóstico Erróneo , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Broncoscopía/normas , Endosonografía/normas , Femenino , Humanos , Neoplasias Pulmonares/terapia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Ultrasonografía Intervencional/normas
9.
Chest ; 156(5): 954-964, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31356810

RESUMEN

BACKGROUND: When evaluating peripheral pulmonary lesions, a 3.0-mm ultrathin bronchoscope (UTB) with a 1.7-mm working channel is advantageous regarding good access to the peripheral airway, whereas a 4.0-mm thin bronchoscope provides a larger 2.0-mm working channel, which allows the use of various instruments including a guide sheath (GS), larger forceps, and an aspiration needle. This study compared multimodal bronchoscopy using a UTB and a thin bronchoscope with multiple sampling methods for the diagnosis of peripheral pulmonary lesions. METHODS: Patients with peripheral pulmonary lesions ≤ 30 mm in diameter were recruited and randomized to undergo endobronchial ultrasonography, virtual bronchoscopy, and fluoroscopy-guided bronchoscopy using a 3.0-mm UTB (UTB group) or a 4.0-mm thin bronchoscope (thin bronchoscope group). In the thin bronchoscope group, the use of small forceps with a GS or standard forceps without the GS was permitted. In addition, needle aspiration was performed for lesions into which an ultrasound probe could not be inserted. RESULTS: A total of 360 patients were enrolled, and 356 were included in the analyses (median largest lesional diameter, 19 mm). The overall diagnostic yield was significantly higher in the UTB group than in the thin bronchoscope group (70.1% vs 58.7%, respectively; P = .027). The procedure duration was significantly shorter in the UTB group (median, 24.8 vs 26.8 min, respectively; P = .008). The complication rates were 2.8% and 4.5%, respectively (P = .574). CONCLUSIONS: Multimodal bronchoscopy using a UTB afforded a higher diagnostic yield than that using a thin bronchoscope in the diagnosis of small peripheral pulmonary lesions. TRIAL REGISTRY: UMIN Clinical Trials Registry; No.: UMIN000010133; URL: https://www.umin.ac.jp/ctr/.


Asunto(s)
Broncoscopios , Broncoscopía/métodos , Neoplasias Pulmonares/diagnóstico , Pulmón/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Endosonografía , Diseño de Equipo , Femenino , Humanos , Biopsia Guiada por Imagen/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
10.
Respir Investig ; 57(3): 238-244, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30738922

RESUMEN

BACKGROUND: The safety management committee of the Japan Society for Respiratory Endoscopy (JSRE) conducted national surveys to clarify the state of diagnostic and therapeutic bronchoscopy in 2016. METHODS: Questionnaire forms were mailed to 532 JSRE-accredited facilities throughout Japan. We surveyed the actual condition of clinical practice and cases of bronchoscopy during 2016. RESULTS: Four hundred and thirty-three facilities responded giving a response rate of 81.4%; 67.6% held more than 400 beds. The average number of board accredited senior Fellows and Fellows per facility was 1.9 and 3.2, respectively. Diagnostic bronchoscopy was performed in a hospitalized setting in 74.6% of all facilities. The radial type ultrasound probe was operated in 51.7% of all facilities. The number of facilities has markedly increased compared with that reported in the 2010 survey (19.6%). The bronchoscopic navigation system had been in operation in 41.7% of all facilities. Antithrombotic drugs were adjusted before biopsy in 96.8% of all facilities. For intravenous sedation, midazolam was the first choice in 76.9% of all facilities. Endobronchial ultrasound guided transbronchial lymph node needle aspiration (EBUS-TBNA) has become popular over the decade (19.6% in 2010 to 68.1% in 2016). The mean number of the board accredited senior Fellows and board accredited Fellows increased in comparison with that in 2010. As a new technique, radial type ultrasound-guided peripheral approach has become popular. CONCLUSIONS: Through this survey, the advanced safety of bronchoscopic examination has been secured in many facilities. A continuous monitoring of bronchoscopic practices with respect to safety management is recommended.


Asunto(s)
Broncoscopía/estadística & datos numéricos , Administración de la Seguridad/estadística & datos numéricos , Acreditación/estadística & datos numéricos , Broncoscopía/métodos , Sedación Consciente , Estudios Transversales , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/estadística & datos numéricos , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Japón/epidemiología , Ganglios Linfáticos/patología , Masculino , Midazolam/administración & dosificación , Seguridad , Encuestas y Cuestionarios , Factores de Tiempo
12.
BMC Pulm Med ; 17(1): 184, 2017 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-29228929

RESUMEN

BACKGROUND: Transbronchial biopsy for peripheral pulmonary lesions is generally performed under X-ray fluoroscopy. Virtual bronchoscopic navigation (VBN) is a method in which virtual images of the bronchial route to the lesion are produced based on CT images obtained before VBN, and the bronchoscope is guided using these virtual images, improving the diagnostic yield of peripheral pulmonary lesions. VBN has the possibility of eliminating the need for X-ray fluoroscopy in the bronchoscopic diagnosis of peripheral lesions. To determine whether VBN can be a substitute for X-ray fluoroscopy, a randomized multicenter trial (non-inferiority trial) was performed in VBN and X-ray fluoroscopy (XRF) -assisted groups. METHODS: The non-inferiority margin in the VBN-assisted group compared with the XRF-assisted group was set at 15%. The subjects consisted of 140 patients with peripheral pulmonary lesions with a mean diameter > 3 cm. In the VBN-assisted group, the bronchoscope was guided to the lesion using a VBN system without X-ray fluoroscopy. In the XRF-assisted group, the same bronchoscope was guided to the lesion under X-ray fluoroscopy. Subsequently, in both groups, the lesion was visualized using endobronchial ultrasonography with a guide sheath (EBUS/GS), and biopsy was performed. In this serial procedure, X-ray fluoroscopy was not used in the VBNA group. RESULTS: The subjects of analysis consisted of 129 patients. The diagnostic yield was 76.9% (50/65) in the VBN-assisted group and 85.9% (55/64) in the XRF-assisted group. The difference in the diagnostic yield between the two groups was -9.0% (95% confidence interval: -22.3% ~ 4.3%). The non-inferiority of the VBN-assisted group could not be confirmed. The rate of visualizing lesions by EBUS was 95.4% (62/65) in the VBN-assisted group and 96.9% (62/64) in the XRF-assisted group, being high in both groups. CONCLUSIONS: On EBUS/GS, a bronchoscope and biopsy instruments may be guided to the lesions using VBN without X-ray fluoroscopy, but X-ray fluoroscopy is necessary to improve the accuracy of sample collection from lesions. During transbronchial biopsy for peripheral pulmonary lesions, VBN cannot be a substitute for X-ray fluoroscopy. TRIAL REGISTRATION: UMIN-CTR (UMIN000001710); registered 16 February 2009.


Asunto(s)
Broncoscopía/métodos , Endosonografía/métodos , Fluoroscopía/métodos , Neoplasias Pulmonares , Pulmón , Tomografía Computarizada por Rayos X/métodos , Anciano , Biopsia/métodos , Investigación sobre la Eficacia Comparativa , Precisión de la Medición Dimensional , Femenino , Humanos , Biopsia Guiada por Imagen/métodos , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad
14.
Respir Investig ; 54(4): 224-9, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27424820

RESUMEN

Bronchoscopy to examine peripheral pulmonary lesions is performed using a bronchoscope with an outer diameter of 5-6mm under fluoroscopy, but the diagnostic yield can be insufficient. Problems with transbronchial biopsy include a limited range of bronchoscope insertion, difficulty in guiding a bronchoscope and biopsy instruments to lesions, and insufficient confirmation of the arrival of biopsy instruments at the target lesion; as such, new techniques have been used to overcome these individual problems. Radial-endobronchial ultrasound is used to identify peripheral pulmonary lesions and sampling sites. In a meta-analysis, the diagnostic yield, that of lesions smaller than 2cm, and complication rate were 73, 56.3, and 1.0%, respectively. Virtual bronchoscopic navigation is a method to guide a bronchoscope to peripheral lesions under direct vision using virtual bronchoscopic images of the bronchial route, and the diagnostic yield, that of 2-cm or smaller lesions, and complication rate were 73.8, 67.4, and 1.0%, respectively. Electromagnetic navigation utilizes electromagnetism; the diagnostic yield was 64.9-71%, and the pneumothorax complication rate was 4% for this modality. Ultrathin bronchoscopes can be advanced to the peripheral bronchus under direct vision in contrast to normal-size bronchoscopes, and the diagnostic yield and pneumothorax complication rates were reported to be 63 and 1.5%, respectively. The overall diagnostic yield of these new techniques on meta-analysis was 70%, a higher yield than that obtained with conventional transbronchial biopsy. Each technique has advantages and disadvantages, and the investigation of appropriate combinations corresponding to individual cases is necessary.


Asunto(s)
Broncoscopía/métodos , Pulmón/patología , Colonografía Tomográfica Computarizada , Humanos , Neoplasias Pulmonares/patología , Metaanálisis como Asunto
15.
J Bronchology Interv Pulmonol ; 22(3): 259-62, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26165898

RESUMEN

The aspiration of foreign bodies may induce various infectious diseases, including actinomycosis, and its association with foreign bodies has been reported. We encountered a patient who developed Actinomyces-induced lung abscess associated with aspiration of cedar leaves. The patient was a 56-year-old Japanese woman who aspirated decorative cedar leaves contained in a lunch box while eating a meal, and coughing and bloody phlegm occurred thereafter. A mass was noted in the right lower lobe of the lung on plain chest computed tomography on the first consultation, and granules of Actinomyces were noted on transbronchial lung biopsy. Long-term antibiotic administration was performed, but no improvement was obtained. Thus, right lower lobectomy was performed. On postoperative pathologic examination, cedar leaves were present in the bronchus, bacterial colonies adhered to these, and there was surrounding inflammatory cell infiltration, mainly involving histiocytes and lymphocytes. This is the first report of Actinomyces associated with aspiration of cedar leaves. When the foreign body cannot be removed, it may be difficult to improve the condition by antibiotic administration alone, and surgery may be necessary.


Asunto(s)
Actinomyces/aislamiento & purificación , Actinomicosis/diagnóstico , Cedrus/microbiología , Cuerpos Extraños/complicaciones , Absceso Pulmonar/diagnóstico , Enfermedades Pulmonares/microbiología , Actinomicosis/tratamiento farmacológico , Actinomicosis/microbiología , Actinomicosis/cirugía , Antibacterianos/administración & dosificación , Biopsia , Broncoscopía/métodos , Claritromicina/administración & dosificación , Femenino , Cuerpos Extraños/diagnóstico por imagen , Humanos , Levofloxacino/administración & dosificación , Absceso Pulmonar/microbiología , Enfermedades Pulmonares/patología , Persona de Mediana Edad , Enfermedades Raras , Tomografía Computarizada por Rayos X
17.
Am J Respir Crit Care Med ; 192(4): 468-76, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26039792

RESUMEN

RATIONALE: The combination of an ultrathin bronchoscope, navigational technology, and endobronchial ultrasound (EBUS) seems to combine the best of mutual abilities for evaluating peripheral pulmonary lesions, but ultrathin bronchoscopes that allow the use of EBUS have not been developed so far. OBJECTIVES: To compare the diagnostic yield of transbronchial biopsy under EBUS, fluoroscopy, and virtual bronchoscopic navigation guidance using a novel ultrathin bronchoscope with that using a thin bronchoscope with a guide sheath for peripheral pulmonary lesions. METHODS: In four centers, patients with suspected peripheral pulmonary lesions less than or equal to 30 mm in the longest diameter were included and randomized to undergo transbronchial biopsy with EBUS, fluoroscopy, and virtual bronchoscopic navigation guidance using a 3.0-mm ultrathin bronchoscope (UTB group) or a 4.0-mm thin bronchoscope with a guide sheath (TB-GS group). MEASUREMENTS AND MAIN RESULTS: A total of 310 patients were enrolled and randomized, among whom 305 patients (150, UTB group; 155, TB-GS group) were analyzed. The ultrathin bronchoscope could reach more distal bronchi than the thin bronchoscope (median fifth- vs. fourth-generation bronchi; P < 0.001). Diagnostic histologic specimens were obtained in 74% (42% for benign and 81% for malignant lesions) of the UTB group and 59% (36% for benign and 70% for malignant lesions) of the TB-GS group (P = 0.044, Mantel-Haenszel test). Complications including pneumothorax, bleeding, chest pain, and pneumonia occurred in 3% and 5% in the respective groups. CONCLUSIONS: The diagnostic yield of the UTB method is higher than that of the TB-GS method. Clinical trial registered with www.umin.ac.jp/ctr/ (UMIN 000003177).


Asunto(s)
Broncoscopios , Broncoscopía/instrumentación , Endosonografía/instrumentación , Biopsia Guiada por Imagen/instrumentación , Neoplasias Pulmonares/patología , Imagen Multimodal/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Fluoroscopía/instrumentación , Humanos , Masculino , Persona de Mediana Edad
18.
Intern Med ; 54(9): 1021-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25948341

RESUMEN

OBJECTIVE: Bronchoscopy using radial-endobronchial ultrasound (R-EBUS) and virtual bronchoscopic navigation (VBN) is a promising method for diagnosing peripheral pulmonary lesions. We previously performed a randomized comparative trial (RCT) (i.e., VBN combined with EBUS RCT) involving patients with 30-mm or smaller peripheral pulmonary lesions and found that the addition of VBN to R-EBUS improved the diagnostic yield. In the present study, we performed a retrospective subanalysis in order to identify patients for whom VBN is useful. METHODS: The per-protocol population (194 cases) of the VBN combined with EBUS RCT was divided into subgroups based on the lesion size, lung lobe containing the lesion, lesion location, presence or absence of involved bronchi (bronchus sign) on thin-section CT and whether the lesion was detected on posterior-anterior (P-A) radiographs. The difference in the diagnostic yield between the VBN-assisted (VBNA) and non-VBN-assisted (NVBNA) groups was investigated. RESULTS: Within the bronchus sign-positive subgroup, the diagnostic yield in the VBNA and NVBNA groups was 94.4% (68/72) and 77.8% (56/72), respectively, showing a significantly higher yield in the VBNA group (p=0.004; odds ratio: 4.9). The yield was particularly high for lesions smaller than 20 mm (94.6% vs. 70.7%; p=0.006), lesions located in the peripheral third of the lung field (95.1% vs. 71.4%; p=0.005) and lesions invisible on P-A radiographs (90.0% vs. 41.7%; p=0.026). CONCLUSION: VBN improves the diagnostic yield when combined with R-EBUS to assess lesions exhibiting involved bronchi on CT images.


Asunto(s)
Bronquios/patología , Broncoscopía/instrumentación , Neoplasias Pulmonares/patología , Interfaz Usuario-Computador , Broncoscopios , Broncoscopía/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Humanos , Pulmón/patología , Neoplasias Pulmonares/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
19.
Intern Med ; 54(5): 497-502, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25758077

RESUMEN

The patient was a 5-year-old boy who was transported to our hospital for a paroxysmal cough, disturbance of consciousness, tonic-clonic convulsions and labored breathing. The patient's respiratory failure persisted after the convulsions remitted, and the presence of an endobronchial foreign body was suspected based on the findings of chest CT performed the following day. A peanut was subsequently removed from the right main bronchus using a bronchoscope with tracheal intubation and bag valve mask ventilation. Immediately after removal, the patient rapidly developed exacerbated hypoxemia, and a reduction in right lung lucency was noted on chest radiography. He was therefore diagnosed with type II postobstructive pulmonary edema, and his condition improved within a short period of time.


Asunto(s)
Bronquios/cirugía , Cuerpos Extraños/complicaciones , Cuerpos Extraños/cirugía , Hipoxia/etiología , Edema Pulmonar/etiología , Preescolar , Epilepsia Tónico-Clónica/etiología , Humanos , Intubación Intratraqueal , Masculino , Respiración Artificial , Tomografía Computarizada por Rayos X
20.
Respiration ; 88(5): 430-40, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25402610

RESUMEN

Virtual bronchoscopic navigation (VBN) is a method in which the bronchoscope is guided on the bronchial route to a peripheral lesion using virtual bronchoscopic images. In reports on VBN for peripheral pulmonary lesions searched in PubMed as of November 2013, the diagnostic yield by ultrathin bronchoscopy in combination with computed tomography and VBN was within the range of 65.4-81.6%. Using endobronchial ultrasonography with a guide sheath (EBUS-GS) and VBN, it was between 63.3 and 84.4%, and using X-ray fluoroscopy and VBN, it was between 62.5 and 78.7%. The overall diagnostic yield was 73.8% [95% confidence interval (CI) 70.9-76.8%] and that for lesions ≤ 2 cm was 67.4% (95% CI 63.3-71.5%). These values indicate high diagnostic rates. In randomized comparative trials, the combination of VBN with EBUS-GS improved the diagnostic yield and shortened the examination time. The diagnostic yields for lesions in the right upper lobe, those invisible on posterior-anterior radiographs and those located in the peripheral third of the lung field were improved by VBN on ultrathin bronchoscopy in combination with X-ray fluoroscopy. The usefulness of VBN was also found on meta-analysis. Taken together, VBN is a promising navigational bronchoscopy method as it requires no specific training, has a low overall complication rate of 1.0% (95% CI 0.2-1.8%) and does not directly induce or cause severe complications. To maximize the full potential of VBN and promote its use, investigation of cases in which it is useful, determination of the optimum combination of procedures, a cost/benefit analysis and advancement of the VBN system are warranted.


Asunto(s)
Broncoscopía , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirugía , Cirugía Asistida por Computador , Humanos , Biopsia Guiada por Imagen , Imagenología Tridimensional , Imagen Multimodal , Tomografía Computarizada Espiral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...