Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Kaohsiung J Med Sci ; 32(1): 38-43, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26853174

RESUMEN

In our study we aimed to evaluate the short-term effects of dorzolamide/timolol on ocular perfusion pressure and retrobulbar blood flow in patients with pseudoexfoliative glaucoma (PXG). This prospective observational cross-sectional study enrolled 22 eyes of 22 newly-diagnosed patients with PXG in a single center. All of the patients received a fixed combination of dorzolamide/timolol. Besides routine ophthalmologic examination, the retrobulbar hemodynamic parameters in the ophthalmic artery, central retinal artery, and short posterior ciliary arteries were measured in all participants at baseline and the 3(rd) month using color Doppler imaging. The mean intraocular pressure (IOP) was 22.3 ± 2.1 mmHg at baseline and reduced to 17.4 ± 2.3 mmHg at the 3(rd) month (p < 0.05). None of the retrobulbar parameters, except peak systolic velocity and resistive index in temporal short posterior ciliary arteries, changed significantly on therapy with dorzolamide/timolol fixed combination when the results were analyzed at Month 3. The drug significantly decreased the peak systolic velocity (p = 0.044) and reduced the resistive index in 0.04 units, 95% confidence interval 0.03-0.05, (p < 0.001) in the temporal short posterior ciliary arteries. This study reports that the retrobulbar hemodynamics might be affected less than expected by dorzolamide/timolol fixed combination in patients with PXG although the reduction of IOP was statistically significant.


Asunto(s)
Inhibidores de Anhidrasa Carbónica/administración & dosificación , Síndrome de Exfoliación/tratamiento farmacológico , Sulfonamidas/administración & dosificación , Tiofenos/administración & dosificación , Timolol/administración & dosificación , Anciano , Estudios Transversales , Combinación de Medicamentos , Ojo/irrigación sanguínea , Femenino , Hemodinámica/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Flujo Sanguíneo Regional , Arteria Retiniana/efectos de los fármacos , Arteria Retiniana/fisiopatología , Resultado del Tratamiento
2.
Eye Contact Lens ; 42(5): 318-21, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26322919

RESUMEN

PURPOSE: To assess changes in anterior-chamber depth (ACD) and angle width after neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy pseudophakia in eyes with pseudoexfoliation (PEX). METHODS: This prospective and interventional case series study included 25 pseudophakic eyes of 25 patients with PEX and 26 pseudophakic eyes of 26 patients without PEX scheduled for Nd:YAG laser capsulotomy in a single institution. Anterior-chamber depth and angle width were measured with anterior segment optical coherence tomography before and three days after Nd:YAG laser capsulotomy. Preoperative and postoperative measurements of ACD and angle width included the angle opening distance (AOD), measured as the perpendicular distance from the trabecular meshwork at 500 and 750 mm anterior to the scleral spur to the anterior iris surface (AOD500 and AOD750, respectively) and anterior-chamber angle (ACA) in the nasal and temporal quadrants. Main outcome measures were the changes in ACD and angle width parameters. RESULTS: The mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.67±0.12 mm, 0.63±0.05 mm and 0.65±0.05 mm, 0.67±0.06 mm and 0.77±0.04 mm, 35.25±1.69° and 35.37±1.68° in eyes with PEX and 3.73±0.11 mm, 0.6±0.05 mm and 0.63±0.05 mm, 0.66±0.06 mm and 0.74±0.06 mm, 34.24±1.6° and 34.6±1.47° in control eyes, respectively (P>0.05 for all). After Nd:YAG laser capsulotomy, mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.76±0.09 mm, 0.73±0.05 mm and 0.76±0.05 mm, 0.75±0.06 mm and 0.87±0.04 mm, 36.82±1.46° and 35.06±1.52° in eyes with PEX and 3.77±0.1 mm, 0.68±0.06 mm and 0.72±0.06 mm, 0.72±0.05 mm and 0.84±0.06 mm, 34.95±1.4° and 35.79±1.36° in control eyes, respectively (P=0.811, P=0.019, P=0.021, P=0.109, P=0.126, P=0.001, and P=0.01, respectively). CONCLUSIONS: The depth and width of the anterior chamber in eyes with PEX and in control eyes increased significantly after Nd:YAG laser capsulotomy. The change in the width of the anterior chamber in eyes PEX was statistically significant comparing control eyes.


Asunto(s)
Cámara Anterior/patología , Síndrome de Exfoliación/patología , Terapia por Láser , Cápsula del Cristalino/cirugía , Capsulotomía Posterior , Seudofaquia/cirugía , Tomografía de Coherencia Óptica/métodos , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Presión Intraocular , Cápsula del Cristalino/patología , Masculino , Persona de Mediana Edad , Capsulotomía Posterior/métodos , Estudios Prospectivos , Seudofaquia/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...