Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Knee Surg Sports Traumatol Arthrosc ; 30(7): 2259-2266, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34665300

RESUMEN

PURPOSE: Meniscal surgery is one of the most common orthopaedic surgical interventions. Total meniscus replacements have been proposed as a solution for patients with irreparable meniscal injuries. Reliable fixation is crucial for the success and functionality of such implants. The aim of this study was to characterise an interference screw fixation system developed for a novel fibre-matrix-reinforced synthetic total meniscus replacement in an ovine cadaveric model. METHODS: Textile straps were tested in tension to failure (n = 15) and in cyclic tension (70-220 N) for 1000 cycles (n = 5). The textile strap-interference screw fixation system was tested in 4.5 mm-diameter single anterior and double posterior tunnels in North of England Mule ovine tibias aged > 2 years using titanium alloy (Ti6Al4Va) and polyether-ether-ketone (PEEK) screws (n ≥ 5). Straps were preconditioned, dynamically loaded for 1000 cycles in tension (70-220 N), the fixation slippage under cyclic loading was measured, and then pulled to failure. RESULTS: Strap stiffness was at least 12 times that recorded for human meniscal roots. Strap creep strain at the maximum load (220 N) was 0.005 following 1000 cycles. For all tunnels, pull-out failure resulted from textile strap slippage or bone fracture rather than strap rupture, which demonstrated that the textile strap was comparatively stronger than the interference screw fixation system. Pull-out load (anterior 544 ± 119 N; posterior 889 ± 157 N) was comparable to human meniscal root strength. Fixation slippage was within the acceptable range for anterior cruciate ligament graft reconstruction (anterior 1.9 ± 0.7 mm; posterior 1.9 ± 0.5 mm). CONCLUSION: These findings show that the textile attachment-interference screw fixation system provides reliable fixation for a novel ovine meniscus implant, supporting progression to in vivo testing. This research provides a baseline for future development of novel human meniscus replacements, in relation to attachment design and fixation methods. The data suggest that surgical techniques familiar from ligament reconstruction may be used for the fixation of clinical meniscal prostheses.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Menisco , Animales , Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Fenómenos Biomecánicos , Tornillos Óseos , Humanos , Menisco/cirugía , Ovinos , Tibia/cirugía
2.
Knee Surg Sports Traumatol Arthrosc ; 28(12): 3709-3719, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32737529

RESUMEN

PURPOSE: To define the bony attachments of the medial ligaments relative to anatomical and radiographic bony landmarks, providing information for medial collateral ligament (MCL) surgery. METHOD: The femoral and tibial attachments of the superficial MCL (sMCL), deep MCL (dMCL) and posterior oblique ligament (POL), plus the medial epicondyle (ME) were defined by radiopaque staples in 22 knees. These were measured radiographically and optically; the precision was calculated and data normalised to the sizes of the condyles. Femoral locations were referenced to the ME and to Blumensaat's line and the posterior cortex. RESULTS: The femoral sMCL attachment enveloped the ME, centred 1 mm proximal to it, at 37 ± 2 mm (normalised at 53 ± 2%) posterior to the most-anterior condyle border. The femoral dMCL attachment was 6 mm (8%) distal and 5 mm (7%) posterior to the ME. The femoral POL attachment was 4 mm (5%) proximal and 11 mm (15%) posterior to the ME. The tibial sMCL attachment spread from 42 to 71 mm (81-137% of A-P plateau width) below the tibial plateau. The dMCL fanned out anterodistally to a wide tibial attachment 8 mm below the plateau and between 17 and 39 mm (33-76%) A-P. The POL attached 5 mm below the plateau, posterior to the dMCL. The 95% CI intra-observer was ± 0.6 mm, inter-observer ± 1.3 mm for digitisation. The inter-observer ICC for radiographs was 0.922. CONCLUSION: The bone attachments of the medial knee ligaments are located in relation to knee dimensions and osseous landmarks. These data facilitate repairs and reconstructions that can restore physiological laxity and stability patterns across the arc of knee flexion.


Asunto(s)
Fémur/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Ligamento Colateral Medial de la Rodilla/diagnóstico por imagen , Tibia/diagnóstico por imagen , Adulto , Anciano , Cadáver , Ligamentos Colaterales/anatomía & histología , Ligamentos Colaterales/diagnóstico por imagen , Femenino , Fémur/anatomía & histología , Humanos , Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/diagnóstico por imagen , Ligamentos Articulares/anatomía & histología , Masculino , Ligamento Colateral Medial de la Rodilla/anatomía & histología , Persona de Mediana Edad , Radiografía/métodos , Tibia/anatomía & histología , Adulto Joven
3.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1587-1594, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30094498

RESUMEN

PURPOSE: Surgeons may attempt to strip the posterior capsule from its femoral attachment to overcome flexion contracture in total knee arthroplasty (TKA); however, it is unclear if this impacts anterior-posterior (AP) laxity of the implanted knee. The aim of the study was to investigate the effect of posterior capsular release on AP laxity in TKA, and compare this to the restraint from the posterior cruciate ligament (PCL). METHODS: Eight cadaveric knees were mounted in a six degree of freedom testing rig and tested at 0°, 30°, 60° and 90° flexion with ± 150 N AP force, with and without a 710 N axial compressive load. After the native knee was tested, a deep dished cruciate-retaining TKA was implanted and the tests were repeated. The PCL was then cut, followed by releasing the posterior capsule using a curved osteotome. RESULTS: With 0 N axial load applied, cutting the PCL as well as releasing the posterior capsule significantly increased posterior laxity compared to the native knee at all flexion angles, and CR TKA states at 30°, 60° and 90° (p < 0.05). However, no significant increase in laxity was found between cutting the PCL and subsequent PostCap release (n.s.). In anterior drawer, there was a significant increase of 1.4 mm between cutting the PCL and PostCap release at 0°, but not at any other flexion angles (p = 0.021). When a 710 N axial load was applied, there was no significant difference in anterior or posterior translation across the different knee states (n.s.). CONCLUSIONS: Posterior capsular release only caused a small change in AP laxity compared to cutting the PCL and, therefore, may not be considered detrimental to overall AP stability if performed during TKA surgery. LEVEL OF EVIDENCE: Controlled laboratory study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Liberación de la Cápsula Articular/métodos , Ligamento Cruzado Posterior/cirugía , Anciano , Artroplastia de Reemplazo de Rodilla/instrumentación , Fenómenos Biomecánicos , Cadáver , Femenino , Fémur/cirugía , Humanos , Liberación de la Cápsula Articular/instrumentación , Luxaciones Articulares/cirugía , Inestabilidad de la Articulación , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteotomía , Presión , Rango del Movimiento Articular , Estrés Mecánico
4.
J Biomech ; 73: 153-160, 2018 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-29622481

RESUMEN

Pre-clinical, bench-top assessment of Total Knee Replacements (TKR) can provide information about the inherent constraint provided by a TKR, which does not depend on the condition of the patient undergoing the arthroplasty. However little guidance is given by the ASTM standard on test configurations such as medial-lateral (M:L) loading distribution, flexion angle or restriction of secondary motions. Using a purpose built rig for a materials testing machine, four TKRs currently in widespread clinical use, including medial-pivot and symmetrical condyle types, were tested for anterior-posterior translational constraint. Compressive joint loads from 710 to 2000 N, and a range of medial-lateral (M:L) load distributions, from 70:30% to 30:70% M:L, were applied at different flexion angles with secondary motions unconstrained. It was found that TKA constraint was significantly less at 60 and 90° flexion than at 0°, whilst increasing the compressive joint load increased the force required to translate the tibia to limits of AP constraint at all flexion angles tested. Additionally when M:L load distribution was shifted medially, a coupled internal rotation was observed with anterior translation and external rotation with posterior translation. This paper includes some recommendations for future development of pre-clinical testing methods.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fenómenos Mecánicos , Cadáver , Humanos , Articulación de la Rodilla/cirugía , Ensayo de Materiales , Rotación , Tibia/cirugía
5.
Knee Surg Sports Traumatol Arthrosc ; 23(6): 1763-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25552404

RESUMEN

PURPOSE: The popliteus tendon is crucial to postero-lateral stability and prone to iatrogenic injury intra-operatively. Its role in the stability of the replaced knee remains contentious. The aim of this study was to use computer navigation to quantify the effect of popliteus sectioning on the 'envelope of laxity' (EoL) offered by a posterior-stabilised (PS) total knee arthroplasty (TKA) and compare with that of the native knee. METHODS: Loaded cadaveric legs were mounted on a purpose built rig. EoL was measured in 3 degrees of freedom using computer navigation. Knees were subjectively stressed in varus/valgus, internal/external rotation and anterior draw. This was performed preoperatively, during TKA and after sectioning of the popliteus tendon. Real-time data were recorded at 0°, 30°, 60° and 90° of flexion as the operating surgeon stressed the knee in 3 degrees of freedom to its subjective endpoint. Mixed-effect modelling was used to quantify the effects of intervention on degree of laxity. RESULTS: In all conditions, there was an increase in laxity with knee flexion. Insertion of a PS TKA resulted in increased constraint, particularly in rotation. Sectioning of the popliteus did not result in a significant increase in knee laxity to 90º of knee flexion. However, at deeper flexion angles, tendon sectioning overcame the constraints of the implant resulting in a significant increase in rotatory and varus/valgus laxity towards the native condition. CONCLUSION: These findings support the view that certain current designs of PS knee replacement can constrain the knee in flexion in the absence of postero-lateral deficiency. For this implant, isolated sectioning of the popliteus tendon did not substantially generate abnormal knee laxity.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador , Traumatismos de los Tendones/fisiopatología , Anciano , Fenómenos Biomecánicos/fisiología , Cadáver , Femenino , Humanos , Inestabilidad de la Articulación/fisiopatología , Articulación de la Rodilla/fisiopatología , Masculino , Rango del Movimiento Articular/fisiología , Tendones/fisiología , Tendones/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA